| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.8 L+₹67,565 (3.53%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹20.9 L+₹1.8 L (9.37%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹22.7 L+₹3.6 L (18.6%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹25.9 L+₹6.7 L (35.2%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-16/2020-21 REPAIRS / MAINTENANCE OF LT DISTRIBUTION SYSTEM CABLES PANELS FEEDER PILLARS AND CONNECTED ITEMS IN DOMESTIC AREA AT AF STATION AMBALA UNDER GE AF AMBALA
2020_MES_364306_1
GE AF/AMB-16/2020-21
Open Tender
Civil Works
Item Rate
240 days
GE AF AMBALA
ALL AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE AF AMBALA
₹60,000
Yes
13 Oct 2020
27 Jul 2020
26 Aug 2020
27 Jul 2020
24 Aug 2020
11 Aug 2020
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for plain cement concrete in 1:3:6 (type C-2) using 40mm graded stone aggregates as bed blocks, foundation, bed to air termination rods complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed for the following bores:
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V (earthed) grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. from any location and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 185sqmm
3.5 core 150sqmm
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 35sqmm
4 core 16sqmm
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for carrying out tests for locating faults in LT cable of any size with the help of fault locator machines, etc. at any location complete all as specified and as directed
M&L for cutting into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
80mm bore
50mm bore
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 6sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections suspended by and including insulated hangers not more than 1.0m c/c and 4mm suspension wire complete all as specified and as directed
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 10sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections suspended by and including insulated hangers not more than 1.0m c/c and 4mm suspension wire complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 4 core, 16 to 50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 70 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 185 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 50 to 150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 16 to 35mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for disconnecting from mains and taking down old / unserviceable feeder pillar boxes / bus bar chambers / DBs of any size at any location including breaking down old PCC platform, etc. and disposing off complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 400A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 200A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
S&F sheet metal enclosures for MCCB distribution board fabricated out of 3.15mm MS sheet, 415V TPN 2 way single door, surface on walls, etc. with 200Amps rated busbar suitable for mounting 4P MCCB 100 to 200A with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
M&L for carrying out repairs / maintenance of existing LT panels at any position / location and of any size, by disconnecting connections, etc. cleaning the entire compartments, arranging cables in proper manner, changing burnt lugs by providing new lugs, thimbles, etc., taping with insulated tapes of all naked cable joints/ends, preparation of old treated surfaces and applying one coat of grey synthetic enamel paint including all necessary welding works to reinstate broken / damaged doors, hinges, supports, legs, etc. and cleaning the surrounding upto 2m all around complete all as specified and as directed
M&L for disconnecting from mains and taking down old / unserviceable LT panels of any size at any location including breaking down old PCC platform, etc. and disposing off complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT feeder pillar box / panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 600A rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned and connecting up complete all as specified and as directed (i) MCCB three phase adjustable type with thermal magnetic release 400A 35kA FP - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 160A 35kA FP - 5Nos. (iii) MCB SPN 32A 10kA - 1No. (iv) Digital ampere meter and voltmeter
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT feeder pillar box / panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 400A rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned capacities and connecting up complete all as specified and as directed
Panel with the following switchgears: (i) MCCB three phase adjustable type with thermal magnetic release 250A 35kA FP - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 100A 35kA FP - 3Nos. (iii) Digital ampere meter and voltmeter
Panel with the following switchgears: (i) Onload changeover switch 4P, 415V, 250A - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 160A 35kA FP - 1No. (iii) MCCB three phase adjustable type with thermal magnetic release 125A 25kA FP - 5Nos. (iv) MCB SPN 32A 10kA - 1No. (v) Digital ampere meter and voltmeter
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT feeder pillar box / panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 300A rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned capacities and connecting up complete all as specified and as directed
Panel with the following switchgears: (i) MCCB three phase adjustable type with thermal magnetic release 160A 35kA FP - 1No. (ii) MCCB three phase 63A 16kA FP - 3Nos. (iii) Digital ampere meter and voltmeter
Panel with the following switchgears: (i) Onload changeover switch 4P, 415V, 160A - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 100A 25kA FP - 3Nos. (iii) MCB SPN 32A 10kA - 1No. (iv) Digital ampere meter and voltmeter
Notes for serial item Nos. 36 to 42: (i) The location of installation shall be as directed by the Engineer-in-charge (ii) Panels shall be of make as detailed hereinafter (iii) Contractor shall submit shop drawings from CPRI approved manufactures / fabricators for approval before procurement (iv) Drawings of panels showing location of switchgears shall be got approved from the GE before incorporation at site
S&F in repairs MCCB 4P 63A 415V 50Hz 16kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 100A 415V 50Hz 16kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 200A 415V 50Hz 25kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 250A 415V 50Hz 25kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 315A 415V 50Hz 35kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 400A 415V 50Hz 35kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 630A 415V 50Hz 50kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs offload change over switch 4P 250Amp 415V with and including suitable sheet metal enclosure and side operating handle complete all as specified and as directed
S&F in repairs offload change over switch 4P 400Amp 415V with and including suitable sheet metal enclosure and side operating handle complete all as specified and as directed
S&F in repairs offload change over switch 4P 630Amp 415V with and including suitable sheet metal enclosure and side operating handle complete all as specified and as directed
S&F in repairs aluminium thimbles 16 to 50sqmm complete all as specified and as directed
S&F in repairs aluminium thimbles 70 to 120sqmm complete all as specified and as directed
S&F in repairs aluminium thimbles 150 to 240sqmm complete all as specified and as directed
S&F in repairs aluminium thimbles 300 to 400sqmm complete all as specified and as directed
S&F in repairs energy efficient LED street light fitting (beamer), 90W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, minimum 50000 burning hours, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 90W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to PCC/steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to concrete surfaces of electric poles with one coat of synthetic enamel paint in black & white alternate stripes, upto a height of 1m from ground, including writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular black synthetic enamel paint base complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting entirely (including covers from both sides) to external exposed concrete / brick surfaces of earthing pits of any size with two coats of synthetic enamel paint (of approved tint) complete all as specified all as directed
S&F 10mm thick CI cover with handle, duly hinged in mild steel angle iron frame of size 300x300x300mm made out of MS angle iron of size 40x40x6mm thick duly fixed to existing earthing pits and entirely painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including dismantling and taking down old pit cover and disposing off complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws, taking down and siposing off old unserviceable block complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for brazing / welding works on joints of any type of earth strip complete all as specified and as directed
S&F in repairs identifier legend plate of GI of size 300x200x1.6mm mounted on 25mm dia GI pipe of 0.9m length including cutting to required shape/size, welding, marking, necessary painting and writing the date, type of earth pit and resistance value, etc. having approved font type and size complete all as specified and as directed
M&L for preventive maintenance to functional earthing GI any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
S&F in repairs GI strip of size 32x6mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs aluminium strip of size 25x3.15mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F PVC / porcelain insulators fixed on walls, etc. complete all as specified and as directed
M&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 25x4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item Nos. 71: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge (iv) The earth resistance shall be less than 01Ohm / as desired by the installation. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect
M&L for disconnecting and taking out capacitor bank panel from foundation, in any location, removing to store / workshop for repair works including testing and calibration of APFC relay, repairs to on delay timer, repair/replacement to indicating lamps, repair to all necessary internal wiring of panel with required size copper lead along with lugs, repairs to power capacitor, repair/replacement of 3 position spring return switch with NO & NC elements, repair to ON Delay suitable for mounting on contactors timer and reinstalling panel in its original position including making good the disturbed foundation / platform complete all as specified and as directed Note: Rate quoted shall be inclusive of all necessary T&P, loading / unloading, carting to and fro to workshop, etc.
S&F in repairs power capacitor, cylindrical, power quality heavy duty 25kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power capacitor, cylindrical, power quality heavy duty 20kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power capacitor, cylindrical, power quality heavy duty 5kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power factor controler PFC, 8 stage relay, three phase, 415V, 50Hz of existing type complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil, coil voltage 240V for 50kVAR power capacitor including all connections and testing complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil, coil voltage 240V for 25kVAR power capacitor including all connections and testing complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil, coil voltage 240V for 5kVAR power capacitor including all connections and testing complete all as specified and as directed
S&F in repairs MCB TP, C curve, 415V, 6 to 32Amps, 10kA complete all as specified and as directed
S&F in repairs MCB TP, C curve, 415V, 40 to 63Amps, 10kA complete all as specified and as directed
S&F in repairs illuminated type push button for control & signalling units, flush integral LED type 230V AC complete all as specified and as directed
S&F in repairs phase indicator lamp with lamp suitable for low/high input, on/off indication, increase/decrease voltage indication, set of 2 pieces each 230V, single phase complete all as specified and as directed
CHAUHAN ENTERPRISES
Bairagi Builders
R N Enterprises
Raman Electric Trading Co
R D Bansal
Esha Engineers
M/S Sonu Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .