Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.9 CrAccepted-AOC KANNUR | KERALA | 670001 | ₹24.9 Cr | 1 | Accepted-AOC L1 Bidder |
| 2 | 2₹23.0 CrRejected-AOC | ₹23.0 Cr | 2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
21 Oct 2024, 6:00 pmClosed
Managing Director
IMPACT Kerala Ltd, Thiruvananthapuram
Civil, Electrical, Plumbing, Fire, STP, Biogas etc
2024_IKL_692428_1
IKL/MKT/2024/1
Open Tender
Civil Works - Buildings
545 days
Nedumangad Municipality
Pls see tender details
6 documents required · 6 mandatory
₹17,700
Yes
₹5 L
Yes
online
17 Feb 2025
26 Sept 2024
23 Oct 2024
26 Sept 2024
21 Oct 2024
26 Sept 2024
1 Oct 2024
Amount
CIVIL WORKS
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
od2642/2020_2021 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.<br>All kinds of soil<br>Modified DAR 2.6.1 and 2.26.1<br>-1.50 to -3.00 m level
od2643/2020_2021 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.<br>All kinds of soil<br>Modified DAR 2.6.1 and 2.26.1<br>-3.00 to -4.50 m level
od2644/2020_2021 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.<br>All kinds of soil<br>Modified DAR 2.6.1 and 2.26.1<br>-4.50lvl to -6.00lvl
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od145155/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. <br>All work upto plinth level
od145261/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. <br>All work above plinth level upto floor V level
od145275/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M- 20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.<br> All work up to plinth level
od145282/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.<br> All work above plinth level upto floor V level
5.4 : Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
od146403/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.<br>All work upto plinth level
od146404/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. <br>All work above plinth level upto floor V level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.16.2 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.6.1.7 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.1.8 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
50.6.1.9 : Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
od117324/2022_2023 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor V level for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete<br>Modified Approved Observed data 50.6.3.2
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
22.3 : Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
10.20 : Providing and fixing bolts including nuts and washers complete.
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
od166556/2023_2024 : Providing and fixing Skylight glazing in the existing frame with gum /silicone sealant of VOC content must not exceed 100g/L etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (frame paid separately).With Skylight glazing of maximum U-factor of 4.25W/m2K and a maximum SHGC of 0.35 glass panes of (6 mm+1.52mm lamination+6mm clear)
12.20 : Providing and laying pressed clay tiles ( as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat completeProviding and laying pressed clay tiles ( as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 ( 1 cement : 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) and finished neat complete
od5139/2020_2021 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern.<br>Modified DAR 12.49
12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)
od149528/2023_2024 : Providing Vacuum Dewatered Flooring for the flooring concrete of thickness 7 cm (1:2:4)consisting of providing side shuttering with MS channels as per specifications, vibrating the concrete by using approved make equipment and dewatering by vacuum using approved suction apparatus including using necessary screed vibrators etc. complete<br>Rate including laying floor hardener , non-metallic surface floor hardener at the rate of 2.5kg/sqm all<br>as per manufactures specifications.
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick
11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
16.90 : Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
od192662/2020_2021 : Providing and fixing I st quality glazed vitrified wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.<br>Modified DAR 11.46.2
od126786/2024_2025 : Providing and laying rectified Anti-skid vitrified floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.<br>Modified DAR 11.41.2.
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
12.59.1 : Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
od227946/2023_2024 : Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant of VOC content must not exceed 50g/L , over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600<br>Upto 5 mm depth and 5 mm width<br>DAR 21.19.1 (2018)
9.136 : Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ).
10.14.1.1 : Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
9.137 : Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge ( panneling to be paid for separately).
9.138.1 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.With clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire resisitance
10.11.2 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
10.30.2 : Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :5.5 mm thick glass panes
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
9.118.2 : Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
od227429/2023_2024 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:<br>a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design<br>of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:<br>b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.<br>c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment ,<br>including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. The VOC content of sealant used must not exceed 100g/L.<br>d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to<br>make it watertight.<br>e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.<br>Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant<br>items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.<br>Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is<br>payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system. Tests to be conducted in the NBL Certified laboratories<br>1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr"<br>2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml."<br>3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml"<br>4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm"<br>5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test" Tests to be conducted on site<br>6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml"<br>Item 25.2 , DAR 2018
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
od5144/2020_2021 : Providing and fixing climber trellis PVC coated wire mesh of required width in mesh size 25x25mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.<br>Modified DAR 16.71
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od189095/2023_2024 : Applying two coat of water thinnable cement primer of approved brand and manufacture on wall surface:<br>Water thinnable cement primer.<br>Modified DAR 13.43.1 with 2 coat of 0808.
od7157/2020_2021 : Applying two coat of water thinnable cement primer of approved brand and manufacture on wall surface:<br>Water thinnable cement Exterior primer<br>Modified DAR 13.43.1 with 2 coat of 0809 (exterior primer).
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
od175454/2023_2024 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile) content less than 50gm/litre including applying additional coats wherever required to achieve even shade and colour.<br>Two coats<br>DAR 13.83.2
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.
16.47.1 : Painting runway/ taxi track /apron making with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-Charge, i/c cleaning the surface of all dirt, scales, oil grease and other foreign material etc. and lining out complete.New work ( Two or more coats)
od140682/2023_2024 : Supplying and installing partitions for urinals of Ladies with following specifications. Thickness of Compact Laminate : 12mm<br>Color of HPL Boards: Single Standard Compact Color<br>Special Remarks For Customization :For IWC and female urinal shoe box in front and in divider<br>Size of Cubicle : As per Drawing (W) x (D) x 2100-2003mm (H)<br>Door Size : 1950-1750mm (H) x 600mm (W)<br>Divider Size : 1962-1775mm (H)<br>Overall Height Of Cubicle : 2100-2003mm (Including bottom Gap of 10-150mm)<br>Accessories: Standard - Make Aluminum, Nylon Polyamide 6 accessories)<br>a) Aluminum "U" Channel<br>b) Aluminum "F" Channel (Only Corner Unit)<br>c) Aluminum Door Stopper Channel<br>d) Aluminum Top Rail<br>e) Nylon Coat Hook<br>f) Nylon Privacy Thumb turn c/w Occupancy Indicator<br>g) Nylon Door Knob<br>h) Nylon Gravity Hinges Left/Right -Gravity to Close<br>i) SS Shoe Box in 316 Grage for Botttom<br>j) Rubber Door Stopper Lining<br>k) S.S.Screws 304 G & P.V.C Wall Plugs<br>SPECIAL NOTE - Warpage Criteria is 3.0 mm/1000mm for MRS panels as per EN standard- 438
od140683/2023_2024 : Supplying and installing partitions in between the urinals of Gents with following specifications. Thickness of Compact Laminate : 12mm<br>Color of HPL Boards: Single Standard and Plain Compact Color<br>Special Remarks For Customization : N/A<br>Size of UMP : 500mm (W) X 1200mm (H)<br>Overall Height Of UMP : 1850mm (Including bottom Gap of 650mm)<br>Accessories: Standard - Make Stainless Steel - 304 Grade accessories) - SS<br>a) SS Right Angle Brackets<br>b) S.S.Screws 304 G & P.V.C Wall Plugs<br>SPECIAL NOTE - Warpage Criteria is 3.0 mm/1000mm for MRS panels as per EN standard- 438.
od168201/2023_2024 : Supplying and placing of High Density Polyethylene Waste bins of 120L capacity with wheels and cap in the various locations of the building with color specifications.
od175331/2023_2024 : Supplying and placing of High Density Polyethylene Waste bins of 60L capacity with wheels and cap in the various locations of the building with color specifications.
PLUMBING WORKS
od133563/2023_2024 : Supply, installation, testing & commissioning of the Colour/White vitrious china Floor mounted European Water Closet (EWC) with C.P bolts, screws, washers, angle cock, flexible pipe, solid seat cover& lid, waste pipe connection, dual flush flush valve, etc. as applicable and complete including breaking and making good the wall and floor as per Architectural drawings and relevant Standards. <br>Use green pro. Certified fixtures and low flow rate fixtures of flow rate 4LPF/2LPF at 3 bar pressure.<br>Modified DAR 17.1
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
od34202/2024_2025 : Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:<br>Single half stall urinal with 5 litre PVC. automatic flushing cistern with low flow rate of 2LPF at 3 bar pressure. <br>Modified DAR<br>17.5.1
od34203/2024_2025 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:<br>White Vitreous China Wash basin size 630x450 mm with of 15 mm C.P. brass pillar taps of flow rate 5LPF at 3 bar pressure Green pro certified . Modified DAR 17.7.1
od356485/2023_2024 : Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white PVC. automatic flushing cistern, with fittings, standard size, G.I./PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I. clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required:<br>Single squatting plate with 5 litre PVC automatic flushing cistern<br>flow rate 2LPF at 3 bar pressure<br>Modified DAR 17.6.1
od133651/2023_2024 : Supply, installation, testing & commissioning of the C.P Health faucet with holder, one meter long flexible pipe, angle valve with wall flange and complete including breaking and making good the wall and floor as per Architectural drawings and relevant standards.<br>Use Green pro. certified low flow rate Health faucet 4LPM at 3 bar pressure<br>Modified DAR 18.53.
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
od139074/2023_2024 : Supply, installation and commissioning charges for SS sink (size:610x510x200) for janitors cleaning purpose in janiters closet without drain board and wall tap with other accessories etc. as applicable, complete including breaking and making good the wall as per Architectural drawings and as relevant standards. Use low flow rate pillar tap of flow rate 5LPF at 3 bar pressure, Modified DAR 17.10.2.1
od139075/2023_2024 : Supply, installation and commissioning charges for Long Body Type Bip Tap including, accessories, wall flange, washers, etc. as applicable, complete including breaking and making good the wall as per Architectural drawings and as relevant standards.<br>Use low flow rate bib tap of flow rate 5LPF at 3 bar pressure
od139076/2023_2024 : Supply, installation and commissioning charges for SS 304 grade Toilet Paper Holder with flap including, accessories, bolts/screws, washers, etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>Modified DAR 17.34.1
od139077/2023_2024 : Supply, installation and commissioning charges for SS 304 grade Towel Ring including, accessories, bolts/screws, washers,etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>Modified DAR 17.34.1
od139078/2023_2024 : Supply, installation and commissioning charges for Tumbler Holder including, accessories, bolts/screws, washers, etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>Modified DAR 17.34.1
od139079/2023_2024 : Supply, installation and commissioning charges for SS 304 grade Soap Dispenser including, accessories, bolts/screws, washers, etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>Modified DAR 17.34.1
od139080/2023_2024 : Supply, installation and commissioning charges for SS 304 grade Robe Hook including, accessories, bolts/screws, washers, etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>Modified DAR 17.34.1
od139081/2023_2024 : Supply, installation and commissioning charges for 690mm Grab Bar including, accessories, bolts/screws, washers ,etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>Modified DAR 17.34.1
od139082/2023_2024 : Supply, installation and commissioning charges for Floor Drain Outlets including, accessories, bolts/screws, washers, etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.<br>150x150 1.2mm thick SS 304 grade lockable type floor drain
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes
od4416/2020_2021 : Supply, installation, testing & commissioning of water supply system pipe work including solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI "U" bolts, GI slotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc. with pipes (Schedule-40) and fittings as per uPVC schedule-80 suitable for working pressure of 20bars all in accordance with drawings and relevant standards.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs.<br>For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab. <br> 65mm dia<br>Modified DAR 18.7.1
od4417/2020_2021 : Supply, installation, testing & commissioning of water supply system pipe work including solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI "U" bolts, GI slotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc. with pipes (Schedule-40) and fittings as per uPVC schedule-80 suitable for working pressure of 20bars all in accordance with drawings and relevant standards.<br><br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs.<br>For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab. <br>80 mm cPVC (SH-40)<br>Modified DAR 18.7.1
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal
od4437/2020_2021 : Supply, installation, testing and commissioning of fullway lever operated forged brass ball valves with brass body with necessary MTA fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards.<br>20 mm automatic air release valve.<br>Modified DAR 18.17.1
od4438/2020_2021 : Supply, installation, testing and commissioning of fullway lever operated forged brass ball valves with brass body with necessary MTA fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards.<br>50 mm Float Valve.<br>Modified DAR 18.17.3
od4439/2020_2021 : Supply, installation, testing and commissioning of fullway lever operated forged brass ball valves with brass body with necessary MTA fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards.<br>65 mm Float Valve.<br>Modified DAR 18.17.3
od4440/2020_2021 : Supply, installation, testing and commissioning of brass Y-type strainer with screwed drain plug, SS 304 screen with supports, flanges, fixings and fittings all as specified and as shown on drawings and complying to relevant standards.<br>40 mm Y Strainer.<br>Modified DAR 18.17.3
od4441/2020_2021 : Supply, installation, testing and commissioning of brass Y-type strainer with screwed drain plug, SS 304 screen with supports, flanges, fixings and fittings all as specified and as shown on drawings and complying to relevant standards.<br>32 mm Y Strainer.<br>Modified DAR 18.17.3
od4442/2020_2021 : Supply, installation, testing and commissioning of brass Y-type strainer with screwed drain plug, SS 304 screen with supports, flanges, fixings and fittings all as specified and as shown on drawings and complying to relevant standards.<br>25 mm Y Strainer.<br>Modified DAR 18.17.3
od4443/2020_2021 : Supply, installation, testing & commissioning of uPVC puddle flanges in the water tanks with necessary fittings in accordance with the drawings and relevant standards. <br>25mm Puddle Flange.<br>Modified DAR 18.17.3
od4444/2020_2021 : Supply, installation, testing & commissioning of uPVC puddle flanges in the water tanks with necessary fittings in accordance with the drawings and relevant standards. <br>32mm Puddle Flange.<br>Modified DAR 18.17.3
od4445/2020_2021 : Supply, installation, testing & commissioning of uPVC puddle flanges in the water tanks with necessary fittings in accordance with the drawings and relevant standards. <br>40mm Puddle Flange.<br>Modified DAR 18.17.3
od4446/2020_2021 : Supply, installation, testing & commissioning of uPVC puddle flanges in the water tanks with necessary fittings in accordance with the drawings and relevant standards. <br>50mm Puddle Flange.<br>Modified DAR 18.17.3
od4447/2020_2021 : Supply, installation, testing & commissioning of uPVC puddle flanges in the water tanks with necessary fittings in accordance with the drawings and relevant standards. <br>65mm Puddle Flange.<br>Modified DAR 18.17.3
od4448/2020_2021 : Supply, installation, testing & commissioning of uPVC puddle flanges in the water tanks with necessary fittings in accordance with the drawings and relevant standards. <br>80mm Puddle Flange.<br>Modified DAR 18.17.3
od4449/2020_2021 : Supply, installation, testing & commissioning of Multijet water meter with necessary fittings in accordance with the drawingsand relevant standards. <br>20mm dia.<br>Modified DAR 18.60.1 (with reference to 18.17.3)
od4450/2020_2021 : Supply, installation, testing & commissioning of Multijet water meter with necessary fittings in accordance with the drawingsand relevant standards. <br>25mm dia.<br>Modified DAR 18.60.1 (with reference to 18.17.3)
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore
od4451/2020_2021 : Supply, installation, testing & commissioning of domestic water filtration system as per water quality check result, including following items pressure sand filter, activated carbon filter, dosing system, multi port valve assembly and related plumbing and electrical works with necessary fittings in accordance with the drawings and relevant standards.<br>5000 LPH Filtration unit.
od172405/2023_2024 : Supply, installation, testing & commissioning of RO plant of 500LPH with SS Tank of 2000LPH capacity as per water quality check result, including materials and all related plumbing and electrical works with necessary fittings in accordance with the drawings and relevant standards.
od4452/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets, etc. for above the ground installation(shafts/suspended) all in accordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>50 mm dia for rain water/vent pipe.<br>Modified DAR 18.7.1
od4468/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>75 mm dia.<br>Modified DAR 18.7.1
od4469/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>110 mm dia.<br>Modified DAR 18.7.1
od4470/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation (shafts/suspended) all inaccordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>160 mm dia.<br>Modified DAR 18.7.1
od4471/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>75 mm dia for rain water/vent pipe.<br>Modified DAR 18.7.1
od4472/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>110 mm dia for rain water/vent pipe.<br>Modified DAR 18.7.1
od4453/2020_2021 : Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.<br>Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI "U" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.<br>160 mm dia for rain water/vent pipe.<br>Modified DAR 18.7.1
od4454/2020_2021 : Supply, installation, testing and commissioning of concealed drainage system (soil & waste water pipes) PVC pipes confirming to IS 13592 Class B including necessary fittings, accessories, supports, brackets, etc including cutting the wall /slabs/surface and making good the wall after installation all in accordance with the drawings and relevant standards.<br>50mm DIA.<br>Modified DAR 18.7.1
od4455/2020_2021 : Supply, installation, testing and commissioning of concealed drainage system (soil & waste water pipes) PVC pipes confirming to IS 13592 Class B including necessary fittings, accessories, supports, brackets, etc including cutting the wall /slabs/surface and making good the wall after installation all in accordance with the drawings and relevant standards.<br>75mm DIA.<br>Modified DAR 18.7.1
od4456/2020_2021 : Supply, installation, testing and commissioning of concealed drainage system (soil & waste water pipes) PVC pipes confirming to IS 13592 Class B including necessary fittings, accessories, supports, brackets, etc including cutting the wall /slabs/surface and making good the wall after installation all in accordance with the drawings and relevant standards.<br>110MM DIA.<br>Modified DAR 18.7.1
od4457/2020_2021 : Supply, installation, testing and commissioning of UPVC under ground drainage pipes conforming to IS 15328 including necessary fittings, excavation, connection to manholes, bedding the pipe in constant in travels, back filling, removing the surplus etc. as per IS:1742-1983 and testing the lines to required hydraustatis pressure for below ground(seware) installation all inaccordance with the drawings and relevant standards. <br>160 mm dia.<br>Modified DAR 18.9.1
od4458/2020_2021 : Supply, installation, testing and commissioning of UPVC under ground drainage pipes conforming to IS 15328 including necessary fittings, excavation, connection to manholes, bedding the pipe in constant intravels, back filling, removing the surplus etc. as per IS:1742-1983 and testing the lines to required hydraustatis pressure for below ground(seware) installation all inaccordance with the drawings and relevant standards. <br>110 mm dia for vent/rain water pipe.<br>Modified DAR 18.9.1
od4459/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. uPVC deep seal multiple floor Trap.<br>Modified DAR 17.60.1.1
od4460/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards.uPvc Concealed floor trap (7"Deep Seal UPvc fabricated Multi floor trap with Stainless Steel Square frames (150x150mm) SS (304), Rubber Seal and flat round cover with screw and suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc. complete in all respects.<br> 50/75 mm dia outlet (For Urinals In Ceiling).<br>Modified DAR 17.60.1.1
od4461/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards.<br>uPvc P trap with Lip ring (110x110) Stainless Steel grating (300x300mm) SS (304), Rubber Seal and flat round cover with screw and suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc. complete in all respects.<br> 110mm dia outlet (For fish /meat floor trap).<br>Modified DAR 17.60.1.1
od4462/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. 110mm dia outlet rain water outlet costructed with CI body, aluminium ring and grade and SS304 grade screws.<br>Modified DAR 17.60.1.1
od4463/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. 160mm dia outlet rain water outlet costructed with CI body, aluminium ring and grade and SS304 grade screws.<br>Modified DAR 17.60.1
od4464/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. S.S. frame square or round floor clean out with rubber seal and flat cover & screw for following pipe sizes 75MM DIA.<br>Modified DAR 17.60.1.1
od4465/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. S.S. frame square or round floor clean out with rubber seal and flat cover & screw for following pipe sizes 110MM DIA.<br>Modified DAR 17.60.1.1
od4466/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. PVC clean out with accessories for following pipe sizes 110MM DIA.<br>Modified DAR 17.60.1.1
od4467/2020_2021 : Supply, Installation, testing and commissioning of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. PVC clean out with accessories for following pipe sizes 160MM DIA.<br>Modified DAR 17.60.1.1
od4495/2020_2021 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:<br>Inside size 90x80 cm and 45 cm deep including 560 mm dia C.I. cover with frame (Heavy duty):<br>With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.<br>Modified the DAR 19.7.1.1 with 19.8.1.1<br>for 90 cm depth
19.4.1.2 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith Sewer bricks conforming to IS: 4885
18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
od4496/2020_2021 : Supply and fixing of CI manhole frame and cover of lockable type ( Double Sealed ) over openings of under ground sump, overhead tank,rain water Sump, soak pits.<br>600X600 mm size - Heavy Duty cover ( 20 Ton lod bearing )<br>Modified DAR 19.18<br>
od4497/2020_2021 : Supply and fixing of CI manhole frame and cover of lockable type ( Double Sealed ) over openings of under ground sump, overhead tank,rain water Sump, soak pits.<br>600X600 mm size - Medium Duty cover( 2.5 ~10 Ton lod bearing )<br>Modified DAR 19.18
19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
YARD DEVELOPMENT AND LANDSCAPING
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
od145275/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M- 20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.<br> All work up to plinth level
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.2 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
51.2.3 : Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
od175311/2023_2024 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in<br>required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and<br>cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.<br>80 mm thick C.C. paver block of M-30 grade with SRI value in between 29 and 64 light grey or white cement shade and approved design and pattern.<br>Modified DAR 16.91.2
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
SEWAGE TREATMENT PLANT - CIVIL WORK
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
od196695/2020_2021 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.<br>All kinds of soil<br>Modified DAR 2.6.1 and 2.26.1<br>-1.50 to -3.00 m level
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
od145155/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. <br>All work upto plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.2 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
SIGNAGES
od140590/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building. <br>Ramp ahead<br>White Matt with vinyl cut letters<br>Fixing: Direct Wall Mount<br>size 10" * 12 "
od140591/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building. <br>Drinking water in wheel chair accessible<br>height<br>White Matt with vinyl cut letters<br>Fixing: Direct Wall Mount<br>size 16" * 9 "
od140592/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building. Near waste bins (dry and wet)<br>Acrylic with UV Print for content / Vinyl UV <br>print pasting.<br>Fixing: Direct Wall Mount<br>size 15" * 24"
od140593/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building. <br>Posters depicting the green and sustainable measures implemented within the building<br>Acrylic with UV Print for content / Vinyl UV print pasting<br>Fixing: Direct Wall Mount<br>size 18" * 26"
od140594/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building.<br>Gender Neutral toilet signage<br>SS Laser cut with black acrylic as back or <br>front Projected<br>Fixing: Direct Wall Mount<br>size 9" * 14"
od140595/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building.<br> Turn off lights when not in use signage<br>White Matt with vinyl cut letters<br>Fixing: Direct Wall Mount<br>size 22"* 10"
od140596/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building.<br>Save water signages<br>White Matt with vinyl cut letters<br>Fixing: Direct Wall Mount<br>size 9" * 18"
od140597/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building.<br>Preferred EV /low emitting vehicle parking<br>signages<br>Gray ACP with vinyl cut letters<br>Fixing: Direct Wall Mount<br>size:12 "* 24"
od140598/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building.<br>No smoking signages<br>White Matt with vinyl cut letters<br>Size 6" * 12" <br>Fixing: Direct Wall Mount
od140853/2023_2024 : Supplying and installing the signages/posters/placards as per specifications and drawings instructed by concerned engineer, in various locations of building.<br>Differently abled toilet<br>SS Laser cut with black acrylic as back or <br>front projected<br>Fixing: Direct Wall Mount<br>Size 7" * 11"
PLANTS
od152201/2023_2024 : :Planting Buffalo grass(Pearl Grass) by excavating planting bed 30 cm deep at specified area shown in the planting plans and preparing the same with thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying and planting Grass Buffalo grass sod, machine cut at a uniform soil thickness of 15 mm, plus or minus 6 mm, at the time of cutting,<br>measurement for thickness shall exclude top growth and thatch. Individual pieces of Buffalo grass sod shall be cut to the supplier’s standard width and length. Maximum allowable deviation from standard widths and lengths shall be plus or minus 15 mm on width and plus or minus five percent on length. Broken pads and torn or uneven ends will not be acceptable. Standard size sections of Buffalo grass sod shall be strong enough that it can be picked up and handled without damage. Buffalo grass sod shall not be harvested or<br>transplanted when its moisture content (excessively dry or wet) may adversely affect its survival. Before harvesting, the turfgrass shall be mowed uniformly at a height of 25 to 60 mm on winter season grasses and 20 to 40 mm on summer season. Grass turfgrass sod should be transported unloaded at site with care and protection and without any damage. The planted Grass turfgrass have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials,<br>safe keep of Grass , cost of conveyance, removal of rubbish and surplus earth etc. Complete.
od69647/2024_2025 : Planting Mussaenda erythrophylla (Rosea) plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pot of size 25 cm
od69648/2024_2025 : Planting Hibiscus rosasinensis plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in polybag of size 25 cm
od69649/2024_2025 : Planting Bougainvillea plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pot/Plastic pot.
od69650/2024_2025 : Planting Calliandra hybrida plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm
od69651/2024_2025 : Planting Nerium oleander plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in polybag of size 25 cm<br>
od69652/2024_2025 : Planting Tecoma argentea plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Tecoma argentea height 120-135 cm. in big poly bag size 25 cm
od69653/2024_2025 : Planting Bauhinia acuminata plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. <br>Bauhinia acuminata height 60-75 cm. in earthen pot of size 20 cm
od69654/2024_2025 : Planting Gardenia jasminoides plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pot of size 20 cm
od69655/2024_2025 : Planting Saraca indica plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. Saraca indica (Sita Ashok) height 105-120 cm. in big poly bag size 25 cm
od69656/2024_2025 : Planting Hamelia patens plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance,<br>transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Hamelia patens of height 60-75 cm. with 6-8 branches in poly bag of size 25 cm<br>
od70685/2024_2025 : Planting Money Plant Broad Leaves plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot
od70686/2024_2025 : Planting Ipomea purpurea (Morning glory) plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.<br>Ipomea purpurea (Morning glory) of height 30 cm to 45 cm. in 20 cm size of Earthen pot/Plastic pot
od70687/2024_2025 : Planting Azadirachta indicia ( Neem ) plants by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. <br>Azadirachta indicia ( Neem ) height 120-130cm in big polybag size 25 cm
od71035/2024_2025 : Planting Rhapis Palm plants in the cement concrete pot placing at specified area shown in the drawing, planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance etc. Complete.Raphis palm plant, having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed, full of fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot.
Centralized Waste Segregation area
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
od145275/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M- 20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.<br> All work up to plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
60.7.2 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
od175454/2023_2024 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile) content less than 50gm/litre including applying additional coats wherever required to achieve even shade and colour.<br>Two coats<br>DAR 13.83.2
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.20 : Providing and fixing bolts including nuts and washers complete.
od186270/2023_2024 : Providing and fixing PVC coated wire mesh of required width in mesh size 25x25mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
50.12.3.1 : Providing asbestos corrugated sheets roofing up to any pitch and fixing with polymer coated J,or L hooks, bolts and nuts 8 mm dia. G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.
12.4.1 : Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Furniture
od140684/2023_2024 : Supplying and installing Three seater four arm Public / Waiting Seating chair in lobbies with following specifications.<br>Seat & Back :Cold rolled steel with powder coating<br>Beam :Cold rolled steel with powder coating<br>Arm & Leg : High quality mild steel tube/sheet is welded to form the shape .The surface is then cleaned with acid to remove rust and powder coated. Thickness-1.2 mm<br>
Electrical Work
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
od186956/2023_2024 : Supply, installation, testing and commissioning of following wiring devices including switches, sockets with backboxes and front plates. The installation includes all terminations.<br>24X7 Digital Timer Switch (Schneider)
od186957/2023_2024 : Supply, installation, testing and commissioning of following wiring devices including switches, sockets with backboxes and front plates. The installation includes all terminations.<br>Flush/Surface Mount Single Load 360 Degree PIR(Schneider)
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
od125291/2022_2023 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>4 way (4+12), Double door
od126435/2022_2023 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required • (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>8 way (4 + 24), Double door<br>Modified DSR 2.5.2
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od127548/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>2 x 4mm2 XLPE AL Cable
od127549/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>2 x 6mm2 XLPE AL Cable
od127550/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>2 x 10mm2 XLPE AL Cable
od127551/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>2 x 16mm2 XLPE AL Cable
od107718/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>4x 4mm2 XLPE AL Cable
od107719/2022_2023 : Supply,laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>4 x 10mm2 XLPE AL Cable
od107720/2022_2023 : Supply,laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>4x 16mm2 XLPE AL Cable
od107722/2022_2023 : Supply,laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>4 x 25mm2 XLPE AL Cable
od125229/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>4x 6mm2 XLPE AL Cable
od107725/2022_2023 : Supply,laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x 35mm2 XLPE AL Cable
od107727/2022_2023 : Supply,laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards. <br>3.5 x50mm2 XLPE AL Cable
od107728/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x70mm2 XLPE AL Cable
od107730/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x120mm2 XLPE AL Cable
od358242/2023_2024 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with<br>FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and<br>complying to specifications and standards.<br>3.5 x150mm2 XLPE AL Cable
od107731/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x185mm2 XLPE AL Cable
od107732/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x240mm2 XLPE AL Cable
od107733/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x300mm2 XLPE AL Cable
od107734/2022_2023 : Supply, laying , testing and commissioning of 1.1kV, XLPE power cable with FRLS sheath in duct / trench / ground / tray etc. as detailed on drawings and complying to specifications and standards.<br>3.5 x400mm2 XLPE AL Cable<br>
od107735/2022_2023 : Supply,aying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of 3Core 300 Sqmm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required<br>
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.3 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)
9.1.4 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 25 sq. mm (22mm)
od107744/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for <br>following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV <br>grade as required.<br>4 X 4 sq. mm/4x6 sq.mm (25mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
10.1.4 : Supplying and making indoor cable end jointing with cast resin compound, including, lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.2.4 : Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
od107761/2022_2023 : Supply and installation of following sizes of cable tray using 25x6mm Angle Iron Frames and 25mmx6mm iron flats including good quality painting anti corrosive primer.
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.6.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
od100498/2024_2025 : Earthing with G.I. earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. <br>Modified DSR 2018, item 5.4<br>Details of cost for one Set.<br>
6.2 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
6.7 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
6.8 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
6.12 : Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
od107777/2022_2023 : Supply, installation, testing and commissioning of Tube light fitting with Extruded thermoplastic body with PC diffuser , IP23, lamp holder, APF electronic ballast suitable for continuous operation with , RoHS compliant, duly wired up for use on 230 V AC with 2X20W LED with all supports to complete the work.<br>[REGALBATTENT8UPTO2X22WSSBSWH And<br>PHOTONULTRAE2.01213T8SSTL20WLED865SPC}<br>Makes: PHILIPS/OSRAM/BAJAJ/CORVI/SISKA
od107780/2022_2023 : Tube light fitting with Extruded thermoplastic body with PC diffuser , IP23, lamp holder, APF electronic ballast suitable for continuous operation with , RoHS compliant, duly wired up for use on 230 V AC with 20W LED . REGAL BATTEN T8UPTO1X22WSSBSWH And<br>PHOTONULTRAE2.01213T8SSTL20WLED865SPC
od107784/2022_2023 : Supply, installation, testing and commisioning of 10W,230V,50Hz, zero mercury LED bulwith all supports to complete the work.
od107785/2022_2023 : Supply, installation, testing and commisioning of following light fittings with all supports to complete the work. Surface mounted Bulk head fitting for with ABS body and polycarbanate diffuser with 10W,230V AC,50Hz, LED
od107786/2022_2023 : Supply,installation, testing and commissioning of LED Recess mounted round down light with powder coated PDC aluminium body and high quality LGP & PMMA diffuser suitable for indoor applications with control gear with 18W LED.INTEGRANEODLR15WLED857S 15W
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
od163746/2023_2024 : Supply, installation, testing and commissioning of 200mm sweep Heavy Duty<br>Exhaust fan in metal frame working on 230 V A/C. The work shall include making the holes suitable for the size of fan, fixing necessary bolt and nuts making good the damages etc. as required including giving connection with required length of 16/20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant IS.
od107793/2022_2023 : Supply,installation,testing and commissioning of 305mm sweep Heavy Duty Exhaust fan in metal frame working on 230 V A/C.The work shall include making the holes suitable for the size of fan, fixing necessary bolt and nuts making good the damages etc. as required including giving connection with required length of 16/20mm PVC insululated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant IS.
od107794/2022_2023 : Supply of Shock treatment chart with glass and teakwood frame on wall as approved by the directorate of electricity in Local/Hindi & English languages.Make RS PRO or Equivalent.
od107796/2022_2023 : Supply of Laminated drawings of electrical lay out, schematic drawing-A2 Sheet
od107797/2022_2023 : Supplying of wall First aid box 14"x9"x7"; with all the necessary materials and medicines for first-aid as per St. John's SJF M4 or Equivalent
od107798/2022_2023 : Supply of a Pair of 11kV grade rubber gloves made from specially compounded latex.Totally shock proof and tested confirms to IS 4770
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
od107801/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.MAIN PANEL(MSB)<br>Bus Bar: Phase & Neutral: AL,25kA,2Rx65mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:<br>800A,4P,ACB+3O/C+1E/F,uP,Ics/Icw=50kA-1 No<br>Out goings:<br>250A,TPN,MCCB,Ics/Icw=50kA, TM -4 Nos<br>320A,TPN,MCCB,Ics/Icw=50kA, TM -2Nos<br>Surge Protection device type (1&2)-1 Set<br>Provision for Fixing 3Phase CT Type Energy Meter &Accessories-2Set<br>Provision for Fixing 3Phase CT Type Solar Meter &Accessories-1Set<br>
od107802/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalized with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphate and powder coating painted with approved color and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.SSB-1Bus Bar: Phase & Neutral: AL,25kA,1Rx32mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:<br>320A,4P, Automatic Transfer Switch(ATS)-1 No<br>320A,4P,ISOLATOR, AC22B-1 No<br>250/5A, 15VA, CL-1 CT-3Nos <br>Multifuntion meter (V, A, F) with CT-1 Set, Phase Indicators-3 Nos<br>Out goings:<br>100A,TPN,MCCB,Ics/Icw=36kA, TM -3 Nos<br>100A,4P,FN,ISOLATOR -1 Nos<br>80A,TPN,MCCB,Ics/Icw=36kA, TM -1 Nos<br>63A,TPN,MCCB,Ics/Icw=36kA, TM -2 Nos<br>
od107803/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.SSB-1.1(Lift main panel) <br>Bus Bar: Phase & Neutral: AL,25kA,1Rx40mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:<br>100A,4P,ISOLATOR, AC22B-1 No<br>Multifuntion meter (V, A, F, PF, KWH, KW, KVA) with CT-1 , Phase Indicators-3 Nos<br>Out goings:<br>40A,TPN,MCCB,Ics/Icw=16kA, TM -6 Nos<br>
od107804/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.Typical Lift Panel<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx25mmx6mm(Heat Shrinkable Sleeves)<br>Incomer:<br>63A,4P,ISOLATOR, AC22B-1 No<br>Out goings:<br>63A,TPN,SFU with HRC fuse -10 Nos<br>40A,4P,300mA,RCBO-1No<br>25A,2P,30mA,RCCB-1No<br>6A,MCB,1P-2 No<br>
od107805/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.SSB-1.2<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx40mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:<br>100A,4P,ISOLATOR, AC22B-1 No<br>Phase Indicators-3 Nos<br>Out goings:<br>25A,DP,MCCB,25kA, TM -2 Nos<br>32A,DP,MCCB,25kA, TM -1 Nos<br>25A,TPN,MCCB,Ics/Icw=16kA, TM -3 Nos<br>32A,TPN,MCCB,Ics/Icw=16kA, TM -2 Nos<br>50A,TPN,MCCB,Ics/Icw=16kA, TM -1 Nos<br>3Ph 4 W kWh Dir base mtg 240V 10- 60 A Acc 1,Multifuntion meter (V, A, F, PF, KWH, KW, KVA) with CT-1
od107806/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.SSB-1.3<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx40mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:100A,4P,ISOLATOR, AC22B-1 No<br>Phase Indicators-3 Nos<br>Out goings:32A,TPN,MCCB,Ics/Icw=16kA, TM -12 Nos.
od107807/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalized with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, boards with following accessories.SSB-1.5(EXHAUST PANEL)<br>Inbuilt PLC Controller and 4-20 mA CO sensors Integration and fire mode operation shall be provided in panel <br>Bus Bar: Phase & Neutral: AL,25kA,1Rx25mmx6mm(Heat Shrinkable Sleeves)<br>Incomer:<br>100A,4P,ISOLATOR, AC22B-1 No<br>Multifuntion meter (V, A, F, PF, KWH, KW, KVA) with CT-1 Phase Indicators-3 Nos<br>Out goings: DOL Starters -2 no., <br>S/D Starters -1 no., 20A,TPN,MCCB,Ics/Icw=16kA, TM -2 Nos <br>40A,TPN,MCCB,Ics/Icw=16kA, TM -3 Nos, <br>6A,TPN,MCB,C-2No.<br>10A, TPN,MCB,C-2 No.
od107808/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.SSB-2 & 3<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx40mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:<br>320A,4P,ISOLATOR, AC22B-1 No<br>Out goings:<br>63A,TPN,MCCB,Ics/Icw=36kA, TM -6 Nos<br>
od107809/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalized with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, boards with following accessories.SSB-4<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx32mmx10mm(Heat Shrinkable Sleeves)<br>Incomer:<br>250A,4P,ISOLATOR, AC22B-1 No<br>Out goings:<br>100A,TPN,MCCB,Ics/Icw=36kA, TM -1 Nos<br>63A,TPN,MCCB,Ics/Icw=36kA, TM - 3 Nos<br>
od107810/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.TYPICAL METERING PANEL TYPE#1<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx25mmx6mm(Heat Shrinkable Sleeves)<br>Incomer:<br>100A,4P,ISOLATOR, AC22B-1 No<br>Out goings:<br>25A,DP,MCB,C CLASS -12 Nos<br>Provision for fixing single Phase energy meter with cut off fuse-12set<br>
od107811/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.TYPICAL METERING PANEL TYPE#2<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx25mmx6mm(Heat Shrinkable Sleeves)<br>Incomer:<br>100A,4P,ISOLATOR, AC22B-1 No<br>Out goings:<br>25A,DP,MCB,C CLASS -8 Nos<br>Provision for fixing 3 Phase energy meter with cut off fuse-8set<br>
od107812/2022_2023 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel,boards with following accessories.<br>APFC PANEL (40kVAR ):<br>Bus Bar: Phase & Neutral: AL,25kA,2Rx32mmx10mm(Heat Shrinkable Sleeves)<br>Incomer<br>100A,4P,MCCB,Ics/Icw=36kA,TM-1 Nos<br>3CT TYPE 8 STAGES APFC Relay -1No<br>Indicating lamps (LED)- 1Set /// Multifunction meter- 1Set<br>Out goings<br>ON/OFF LED Indication for all Capacitor units-8 Sets<br>10A,3P,MCB,D with Capacitor duty contactor-2 Nos<br>20A,3P,MCB,D with Capacitor duty contactor-3 Nos<br>32A,3P,MCB,D with Capacitor duty contactor-3 Nos<br>10 kVAR 480V Capacitor with 7% DETUNED REACTOR -2 Set<br>5 kVAR 480V Capacitor with 7% DETUNED REACTOR -3 Set<br>2.5 kVAR 480V Capacitor -2 Set<br>
od162961/2023_2024 : Supply, installation, testing and commissioning of following MV Panels made of 14 SWG thick CRCA sheet fully compartmentalised with 16 SWG CRCA sheets, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, boards with following accessories. <br>SSB-5<br>Bus Bar: Phase & Neutral: AL,25kA,1Rx32mmx6mm(Heat Shrinkable Sleeves)<br>Incomer:<br>200A,4P,ISOLATOR, AC22B-1 No<br>Out goings:<br>32A,TPN,MCB,C -9Nos<br>
od107813/2022_2023 : Supply ,installation, testing and commissioning of following set of isolators for equipments such as motors airconditioning units as per the requirement of the other service contractors.<br>63A , FP,SFU with Enclosure
od107814/2022_2023 : Supply ,installation, testing and commissioning of following set of isolators for equipments such as motors airconditioning units as per the requirement of the other service contractors.<br>40A , FP,MCB with Enclosure
od107815/2022_2023 : Supply ,installation, testing and commissioning of following set of isolators for equipments such as motors airconditioning units as per the requirement of the other service contractors.<br>40A , FP,MCB with Outdoor Enclosure
od107816/2022_2023 : Supply ,installation, testing and commissioning of following set of isolators for equipments such as motors airconditioning units as per the requirement of the other service contractors.<br>40A , 2P,MCB with outdoor Enclosure
od107817/2022_2023 : Supply ,installation, testing and commissioning of following set of isolators for equipments such as motors airconditioning units as per the requirement of the other service contractors.<br>3 Phase DOL with Enclosure
od107819/2022_2023 : PACKAGED SUBSTATION --HT INCOMER+500kVA TRANSFORMER <br>Installation, testing and commissioning of 11KV/433V, 3 phase, 500kVA vector DYN-11 transformer with off circuit tapping from +5% to -10% in steps of 2.5%, changeable on off circuit by tap links provided, with WTI & LV terminals includes LT TOD & suitable for 2 runs of PVCA cable and HV terminals connected to 11 KV, 26.3 KA, 630 A Load Break Switch having Emergency Trip facility with incoming suitable for XLPE cable, with HT HRC fuses and output connected to11KV seal off bushings to the transformer.<br>The transformer shall be complied with ECBC 2017 with a total loss of 2.8 kW at 50% loading and 7.25kW loss at 100% loading. (Refer Table-7.1 for permissible loss for dry type transformer).
od107821/2022_2023 : Installation, testing and commissioning of 3phase 4 wire 230V (L-N), 5A CT of class: 0.5S LT TOD meter of approved make, with Test certificate obtained from KSEI, MTSL, KSEB TMR division for TOD meter.<br>
od107822/2022_2023 : Supply,Unloading, Leading,Installation, testing and commissioning of 125kVA, 3phase 433V, 0.8pf 50Hz. Liguid cooled DG set of prime duty comprising of diesel engine alternator, fuel tank, starting system, battery, electronic governor etc with all accessories. The Generator set shall have a integral type acoustic enclosure as per latest CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with CPCB-II specifications. Generator set inclusive of fly wheel, flexible coupling, air cleaner, corrossion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 24V battery with regulator,external battery Charger, Neutral CT and instrument panel, rpm indicator, residential silencer with 30mm 150mm MS B Class Exhuaust with all supports . etc including first filling of oil and diesel for commissioning of the DG set ((Refer Drawing and Specifications)<br>125kVA DIESEL GENERATOR<br>The Generator shall be complied with ECBC 2017 with the specific fuel consumption of the generators in g/kWh must be >245 and <=272.
od107823/2022_2023 : Supply, Installtion of DP Structure with AB switch,LA,Insulator, stay wire earthing and all required accessories as per KSEB norms
od163001/2023_2024 : Supply, Installation, Testing and Commissioning of electric vehicle supply equipment (EVSE) AC wall box charger with earth leakage protection, weather proof enclosure and all standard accessories.
od199539/2023_2024 : Supply, Installation ,testing and commissioning of 5kVA Online UPS for for ELV Systems-30 Min Backup-UPS RC 5000VA 230V | 5kVA Online+8 Nos 42AH SMF Batteries.
od44559/2024_2025 : Supply, installation, testing & commissioning of Water lifting pump, with pumps (2 nos on a 1duty + 1 standby basis) with control panel, automatic change over switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards. BASEMENT DRAIN PIT PUMP AND CONTROL PANELS
od44564/2024_2025 : Supply, installation, testing & commissioning of Water lifting pump, with pumps (2 nos on a 1duty + 1 standby basis) with control panel, automatic change over switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards. DOMESTIC WATER LIFTING PUMP Duty conditions: 260LPM @ 40M Head (One Duty + One standby) UG sump to OH tank -flushing (Pump+ control panel cost)
od138551/2022_2023 : Supply, installation, testing & commissioning of Water lifting pump, with pumps (2 nos on a 1duty + 1 standby basis) with control panel, automatic change over switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards. DOMESTIC WATER LIFTING PUMP Duty conditions: 260LPM @ 40M Head (One Duty + One standby) UG sump to OH tank -drinking (Pump+ control panel cost)
od138552/2022_2023 : Supply, installation, testing & commissioning of Water lifting pump, with pumps (2 nos on a 1duty + 1 standby basis) with control panel, automatic change over switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards. Filter Feed Pump Duty conditions:- 70 LPM @ 25M Head (One Duty + One standby)
od138553/2022_2023 : Supply, installation, testing & commissioning of Water lifting pump, with pumps (1 Sets - 1 on duty+1 on standby) with control panel, automatic change over switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards . Well to UG Sump (pump + control panel cost) Duty conditions:-260 LPM @ 40 M Head
Fire Alarm System
od107622/2022_2023 : Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.<br>Reference DSR 2018 17.2.4
od107629/2022_2023 : Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required.<br>Reference DSR 2018 17.2.9
od107640/2022_2023 : Supplying, installation, testing & commissioning of fault isolator complete with base as required.<br>Reference DSR 2018 17.2.7
od107644/2022_2023 : Supplying, installation, testing & commissioning of addressable fire control module complete as required.<br>Reference DSR 17.2.10
od107650/2022_2023 : Supplying, installation, testing & commissioning of addressable manual call point complete as required.<br>Reference DSR 2018 17.2.14
od107658/2022_2023 : Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.<br>Reference DSR 2018 17.2.15
od107663/2022_2023 : Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.<br>Reference DSR 2018 17.2.17
od107669/2022_2023 : Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.<br>Reference DSR 2018 17.2.19
od107670/2022_2023 : Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.<br>Reference DSR 2018 17.5.1
od107673/2022_2023 : Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.<br>Reference DSR 2018, 17.3.1
od163589/2023_2024 : Supplying, installation, testing & commissioning talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.<br>Reference DSR 2018, 17.1.8
Public Adddressing System
od107621/2022_2023 : Supply and fixing of 1 Way, 6", 6W,100V, 60-15000Hz,90dB, Ceiling Speaker as per drawings
od107626/2022_2023 : Supply and fixing of Outdoor Wall Speaker 30 Watts 2-Way Speaker with all accessories and mounting brackets as per drawings
od107633/2022_2023 Supply and fixing of 2500W PA System amplifier with facility for USB, Memory Card and Minimum 4 Input channel controls as per drawings
od107636/2022_2023 Supply and fixing of PA Series MIC with holder/Stand with cable and connector as per drawings
od107654/2022_2023 Supply and fixing of 2x2.5sqmm PVC insulated Cu cable armoured suitable for PA System as per drawing
Mechanical Ventilation
od132290/2023_2024 : 7000 cfm @ 350Pa external static ductable Cabinet type roof mounted exhaust fans complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
od132291/2023_2024 : 15200 cfm @ 450Pa external static round axial type food court makeup air fan complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
od132292/2023_2024 : 5250 cfm @ 250Pa external static round axial type stall makeup air fan complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
od132293/2023_2024 : 1100 cfm @ 200Pa external static ductable Cabinet type exhaust air ceiling mounted INLINE fans complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
od132294/2023_2024 : 300 cfm @ 200Pa external static ductable Cabinet type exhaust air ceiling mounted INLINE fans complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
od185168/2023_2024 : 7900 cfm @ 250Pa external static round axial type stall makeup air fan complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
od132186/2023_2024 : Direct driven axial fans for exhaust / fresh air as shown in the drawing of following air volume, 300 degree Celsius for 2 hours temperature rating, Class H insulation motor and Inlet guard. The fan shall be suitable for vertical mounting operation. Vertical mounting accessories should be along with the fan. The casing shall be continuously welded galvanized steel with inlet and outlet flanges to prevent air leakage. The fan shall be licensed to bear AMCA certification seal for Sound and Air performance.<br>14000 CFM @ 450Pa External static pressure exhaust fan for basement (Two speed fan - Normal mode & Fire mode)
od132187/2023_2024 : Direct driven axial fans for exhaust / fresh air as shown in the drawing of following air volume, 300 degree Celsius for 2 hours temperature rating, Class H insulation motor and Inlet guard. The fan shall be suitable for vertical mounting operation. Vertical mounting accessories should be along with the fan. The casing shall be continuously welded galvanized steel with inlet and outlet flanges to prevent air leakage. The fan shall be licensed to bear AMCA certification seal for Sound and Air performance.<br>23000 CFM @ 400Pa External static pressure fresh air fan for basement makeup air (Single speed fan - Normal mode)
od132188/2023_2024 : Direct driven axial fans for exhaust / fresh air as shown in the drawing of following air volume, 300 degree Celsius for 2 hours temperature rating, Class H insulation motor and Inlet guard. The fan shall be suitable for vertical mounting operation. Vertical mounting accessories should be along with the fan. The casing shall be continuously welded galvanized steel with inlet and outlet flanges to prevent air leakage. The fan shall be licensed to bear AMCA certification seal for Sound and Air performance.<br>15500 CFM @ 250Pa External static pressure Stair Pressurization (single speed fan - Normal mode)
od132189/2023_2024 : 2400CFM @ 450Pa external static pressure kitchen exhaust fan for food stall 01 to08. Roof mounted kitchen exhaust air fan complete with all accessories including supports / hangers, gravity louvers, canvas connections, etc. as per specifications & drawings
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006
od107681/2022_2023 : Powder coated extruded aluminium Extract air disc valves with MS volume control damper as per drawing and relevant standards.
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.20.1 : Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
16.20.2 : Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
od107694/2022_2023 : Supply and fixing Powder coated extruded aluminium Extract air louvers with aluminium bird screen and MS volume control damper as per drawing and relevant standards.
od107696/2022_2023 : Supply and fixing Powder coated extruded aluminium fresh air louvers with aluminium bird screen and MS volume control damper as per drawing and relevant standards
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 6 sq mm with factory made clamp
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 4 sq mm with factory made clamp
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 6 sq mm with factory made clamp
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp
Fire Fighting System
od133890/2023_2024 : Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) <br>(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with tainless steel shaft, mechanical confirming to IS : 1520 <br>b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, ACsupply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. <br> (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.<br>(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. All equipment's are Green pro certified<br>Duty Conditions : 1350 LPM at 35m head
od133891/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>100mm dia
od133892/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>80mm dia
od133893/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>65mm dia
od133894/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>32mm dia
od133895/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>50mm dia
od133896/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>40mm dia
od133897/2023_2024 : Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br>All material should be Green pro certified.<br>25mm dia
od134385/2023_2024 : Providing laying, testing & commissioning of 'C' class heavy duty GI Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation &providing cement concrete blocks as supports, anticorrosive treatment with coal tar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (wrapping should have overlap of 15 to 20 mm) etc.<br>100MM DIA
od135635/2023_2024 : Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stock bar of following sizes complete as required.<br>1000mm length
od135636/2023_2024 : Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stock bar of following sizes complete as required.<br>1200mm length
od134811/2022_2023 : Allow for GI pipe work and fittings in the water tank including puddle flanges all in accordance with the drawings and specifications.( underground and overhead tanks )
od135697/2023_2024 : Supply, erection, testing & commissioning of 4-Way Breaching inlet assembly 63mm inlet connections with instantaneous coupling and built in NRV complete as specified and as shown on drawings and complying to authority regulations and relevant standards
od135698/2023_2024 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>100MM Dia
od135699/2023_2024 : Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.<br>100MM Dia<br>
od135700/2023_2024 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :<br>100MM Dia
od137355/2023_2024 : Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required.
od137356/2023_2024 : Supply, erection, testing & commissioning of sprinkler heads with all supports, rosset palter, fixings and fittings all as specified and as shown on drawings and complying to authority regulations and relevant standards.<br>Pendant type
od137357/2023_2024 : Supply, erection, testing & commissioning of sprinkler heads with all supports, rosset palter, fixings and fittings all as specified and as shown on drawings and complying to authority regulations and relevant standards.<br>Upright type.
od137358/2023_2024 : Supply, erection, testing & commissioning of sprinkler heads with all supports, rosset palter, fixings and fittings all as specified and as shown on drawings and complying to authority regulations and relevant standards.<br>Horizontal side wall type.
od137359/2023_2024 : Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal cap and chain as required :(Gun Metal)
od137360/2023_2024 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female gun metal couplings duly bound with GI wire, rivets, conforming to IS 636 (type-A) as required :(Gun Metal)
od137361/2023_2024 : Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
od137362/2023_2024 : Supplying and fixing fist aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 & 30m long, 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket with all as specified and as shown on drawings and complying to authority regulations and relevant standards
od134818/2022_2023 : AUTO AIR VENTS - SITC of automatic purge valves at the highest pointsand strategic locations of chilled water piping complete with fittings and accessories as required and specified -25mm Dia.
od134827/2022_2023 : Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in<br>accordance with the drawings and specifications.<br>4.5kg CO2
od134828/2022_2023 : Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in<br>accordance with the drawings and specifications.<br>6Kg Dry Chemical Powder extinguisher
od134829/2022_2023 : Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in<br>accordance with the drawings and specifications.<br>1.8mx1.8m fire blanket
Solar System
od163027/2023_2024 : Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminum/GI structure of suitable strength with following components complete as required:-<br>a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.<br>b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.<br>c) Data Monitoring System complete with accessories.<br>d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.<br>e) Lightning and surge voltage protection.<br>f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.<br>(01 Point = 01kWp)
Elevators
od163747/2023_2024 : Supplying and fixing the 15 passenger , 1020 kg lift (included audio braille system) of speed 1.25 m/s with 5 stops and 5 openings at Lower ground floor , Upper Ground floor, first floor, second floor and terrace floor as per technical specification including all works complete.
od163748/2023_2024 : Supplying and fixing the 15 passenger , 1020 kg lift (included audio braille system) of speed 1.25 m/s with four stops and 4 openings at Lower ground floor , Upper Ground floor, first floor and second floor as per technical specification including all works complete.
od163749/2023_2024 : Supplying and fixing the goods lift (included audio braille system for disabled persons) , 1500 kg lift of speed 0.50 m/s with 5 stops and 5 openings at Lower ground floor, Upper ground floor, first floor , second floor and terrace floor as per technical specification including all works complete.
STP Mechanical Equipments
Supply, installation and commissioning of STP Mechanical Equipments including ultra-filtration plant, electrical & internal piping of the plant as per the details & drawings provided in the tender documents
Biogas Plant
Supply, installation and commissioning of a Biogas Plant of 500kg per day capacity as per the details provided in the tender documents. provided in the tender documents
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY (BID ID -1949792)
Bidder Name
SWATHY CONSTRUCTIONS
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid