Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.4 L+₹4,953 (0.37%)Rejected-Finance 13 11 MOTILAL GUPTA ROAD KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.5 L+₹12,315.90 (0.92%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L3 | Rejected-Finance L3 |
Tender Value
₹13.5 L
EMD Value
₹27,060
Closing Date
4 Dec 2019, 2:00 pmClosed
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Renovation and refurbishing of office premises of Department of Mass Education Extension and Library Services including Directorate of Mass Education Extension at 9th floor Bikash Bhavan EI and allied works SITC of Fire Detection
2019_WBPWD_252013_1
WBPWD/EE/BED/26/e-IT of 2019_20_3rd Call
Open Tender
ELECTRICAL WORKS M/R
Item Rate
30 days
Bikash Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹27,060
Yes
19 Feb 2020
8 Nov 2019
6 Dec 2019
13 Nov 2019
4 Dec 2019
13 Nov 2019
Amount
Supply, Installation,Testing & Commisioning of EN standard, VDS / LPCB Approved Microprocessor based 4 Loops expandable up to minimum 6 Loops, fire alarm control panel fully networkable with each loop capable of taking atleast 125 devices and each loop should be connected to a dedicated loop card (even if a loop card supports multiple loop the panel should be provided with 4 nos loop cards and should have provision for accomodating total 6 nos loop card), 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having minimum 1000 event memory, integral SMF lead acid batteries with sealed cells of 24 V / 12 V with integral battery charger complete as required and as per specification. (Approved Make: Honeywell / Bosch / Securiton / Siemens).
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved Addressable Multi-Sensor Detector (optical smoke as well as heat) with inbuilt / additional Isolator and integral LED status indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40. (Approved Make: Honeywell / Bosch / Securiton / Siemens).
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved Intelligent Analog Addressable Heat Detector (Static + ROR) with inbuilt / additional Isolator and integral LED status indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40. (Approved Make: Honeywell / Bosch / Securiton / Siemens)
Supply, Installation, Testing & Commissioning of Response Indicator, with all other accessories. (Approved Make: Honeywell / Bosch / Securiton / Siemens)
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved Inteliigent addressable manual call point with inbuilt / additional Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra acceesories as required. (Approved Make: Honeywell / Bosch / Securiton / Siemens)
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved Addressable One input & One output module with inbuilt / additional isolator and shall have the LED indication for Normal, Fault, test, and activation.The module shall have the option for configuration as fail safe operation. (Approved Make: Honeywell / Bosch / Securiton / Siemens).
Supply & Drawing of 2 Core 1.5 sq.mm FRLS shielded copper Cable. (Make. Finolex / Technoflex/MEM/KEI/Approved by EIC)
Supply & Laying of 20 mm NB PVC rigid conduit pipe on the surface of the wall Incl. all fittings as required. (Make: Precisson/Presto Plast/Polycab-Medium). N.B. Copy of VDS, EN, LPCB approval / certification document for major items serial no. 1,2,3,4,5,6 & 7 etc in BOQ of this tender must be uploded within the Technical cover. Otherwise the bid may be rejected.
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
S. K. CHATTERJEE ELECTRICALS PVT LTD
GLYPTIC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .