Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹3.6 Cr
EMD Value
₹3.3 L
Closing Date
31 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Implementation of UTS Modernization for Tier-2/3/4 locations as per directions of C&IS Directorate of Rly. Bd. Over Ambala Division.
OT-28-2025-26~NR
OT-28-2025-26
Open
Works - General
270 Days
Ambala, Haryana
₹0
₹3.3 L
31 Dec 2025
8 Dec 2025
17 Dec 2025
Supply of fiber optic patching cord (05 mtrs length) FC-FC/FC-PC/FC-SC/LC-SC/LC-LC as per site requirement/Site Engineer.Inspection by Consignee
Supply UTP Cat -6 Patch Cord 3 Ft. long Schneider, Systemax, Panduit, D-Link, Molex with suitable connector at both ends Inspection by Consignee
Supply UTP Cat -6 Patch Cord 7 Ft.long Schneider, Systemax, Panduit, D-Link, Molex with suitable connector at both ends Inspection by Consignee
Supply of STP (Shielded Twisted Pair) CAT-6 cable compliant with latest EIA/TIA-568- B. 2-1 standard of make D-Link/ DAX/Lucent/ Crone/Amp. Inspection by Consignee
Supply of HDPE duct 40/33 mm as per RDSO/SPN/TC/45/2013 Rev.2.0 with latest 5 amendments as available. For each KM of HDPE DUCT following items are to be supplied a) End plugs-2no b) Cable sealing plugs-2 no. © Plastic couples slip fit/push fit b type-2 no d) End plugs to be provided along with drum-2 nos. Inspection By-RITES.
Supply of 6 Fiber Core armored single mode optic Fiber cable 17.2.2 of RDSO/SPN/ TC/65/2021 Rev.6.0 or latest Schneider, Systemax, Panduit, D-Link, Finolex Inspection by RITES
Supply of Cat-6 I O BOX Make Schneider, Systemax, Panduit, D-Link, Molex, Inspection by Consignee
Supply and installation of PVC channel with cover of size 50mmx 34mm of 1 mm thickness. Inspection By-Consignee.
Supply of Ethernet Tester of Stanlay make NETCATPRO2 or equivalent.Inspection By- Consignee.
Supply of Crimping Tool for Cat-6 cable make (D-Link, AMP or similar) Inspection By- Consignee.
Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance 11 measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 - 49 : 1.5% Also measure current leakage up to 20A. No spikes required for measurement Model - DECT-2 or equivalent / higher version make Motwane/Stanlay/ Fluke/ Megger. Inspection: Consignee Above/
Supply & configuration of 8 Nos. ports of 10/100/1000 Base-T PoE switch with 2 1 Nos.SFP port 120W PoE Budget with supply of 2 nos. Of 1G SFP Single mode optical transceiever modules as per clause no.14 (III) of RDSO Specs. No.RDSO/SPN/TC/65/ 2021 Ver.6.0 with Latest amendments and versions Make CISCO, JUNIPER,Zyxel, D-Link. Payment shall be done as per Tender docuement Inspection by RITES
Supply,Installation,Testing & Commissioning of Equipment rack of size 19''/24U as per technical specification given in Annexure-E.Inspection by RITES.
Supply, Installation, Testing and Commissioning of RJ-45 Jack panel suitable for STP Cat-6 cable Make D-Link, AMP,DAX,Legrand, Molex or Digilink Inspection by Consignee
Supply, Installation, testing & commissioning of UPS (online) 3 KVA as per CEE/NR's Specification no. 89-Elect/P/2000.& as per instructions of Railway Engineer's Representative at site Inspection Material:Consignee, Installation: Site Engineer
Supply, installation, testing, wiring & commissioning of router having ports WAN ports 04 Nos. of 10/100/1000 MB Base T Ethernet Ports, 04 Nos of 1000 MB SFP Slot and 4 nos. of E1 port 5 along with dual power supply along with all associated acessories, power cable, Console cable mannuals Mounting hardware etc. Router also must be equiped with 4 X compatible SFP 1.25 GBPS Single Mode Dual fiber 20 Km. Preferred Make/ Model Techroutes TSR-2900-40 or equivalent model with same specification in Juniper, HP make.Inspection by RITES.
Supply installation & fixing of 25 mm dia PVC conduit medium class pipe with all 6 accessories on any type of surface inluding wal with proper clamping etc. PVC conduit pipe shall confirm IS9537 (PtIII) as per Technical specifications given in Annexure 'E' & instructions of Railway Engineer'srepresentative at site Make Pipe D Plast, Polypack, Polycab Inspection: Site Engineer
Supply installation/recessing of 25 mm dia PVC conduit medium class pipe with all 7 accessories junction box etc making chaise replastered PVC conduit pipe shall confirm IS9537 (PtIII) as per Technical specifications given in Annexure 'E' & instructions of Railway Engineer'srepresentative at site Make Pipe D Plast, Polypack, Polycab Inspection: Site Engineer
Supply and fixing of G.I. pipe with 76.6 mm maximum and 75.3 mm minimum outside dia. And 3.6 mm thickness as per spec no IS- 1239 or latest if any, medium grade, 8 perforated at a distance of 20 CM or less of required length at culverts/ bridges/ along the cuttings, suitably concreted at both ends as per approved drg. No.Drg. No.NR/S&T/CON/1-4/97. G.I. clamps of M.S. flats bolts and nuts to be supplied by the contractor. G.I. pipe and other associated material to be inspected by Consignee. Work at site will be inspected by Site Engineer.
Supply, installation & commissioning of basic earthing kit as per RDSO specification no. RDSO/SPN/197/2008 or latest Earthing kit consisting of 1) Earth electrode of 17 mm dia and 3 M long -01 no. 2). MEEB (300X25X6) cu.mm-01 no. 3). SEEB (150X25X6) cu.mm -01 no. 4). Earth 9 enhancing compound - 30 kg. This includes provision of earth connection from MEEB to S&T equipment i.e. cable sheath etc. with PVC multistrand wire of size 16/25 sq.mm through copper lugs of suitable size. PVC wire shall be supplied be by Railway & as per instructions given by Railway Engineer's Representative at site. Note:- At certain locations, it may not be possible to achieve earth resistance of less than or equal to 1 ohm with one earth electrode/pit due to higher soil resistivity. in such cases, provision of loop earth consisting of more than one earth pit shall be done. for inter connection of two earth pits copper tape of size 25 X2 sq.mm shall be provided by the Contractor. The number of pits required shall be decided based on the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection:RITES
Supply, installation, testing and commissioning of failure analysis system as per Technical Specifications given in Annexure- 'E'. Inspection by Consignee.
Supply and installation (Splicing of fiber) of rack mount LIU 12 core loaded with SC 11 adaptors. Including all accessories as per instructions of Railway Engineer's Representative at site. (pigtails and other miscellaneous material required for the work shall be supplied by the contractor. Make: D-Link, PANDUIT, systemax, Digilink,3M, Molex, Legrand, Commscope, Molex, 3C3, Amphenol FCI or similar of reputed make.Inspection by Consignee
Boring & Trenchless cabling along with supply and insertion of HDPE pipe of PE 80 PN 12 8 grade of 90mm dia with min. 6.7mm and max. 7.6mm wall thickness as per IS 4984:2016 in the bore for the laying of signalling/ Telecom/Power cables under the track/ road.( cable lying is covered separately). HDPE pipe is to be supplied by the contractor. Inspection of Pipe by RITES, Work by Site Engineer Above/
Laying of HDPE duct as per approved cable route plan in the exavated trenches/other protected work/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. 1 The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The layingof OFC cable indepedently or along with Quad cable/PIJF cable in same trench shall be governed by the RDSO drawings no.RDSO/TCDO/COP-6 (a) and RDSO/TCDO/COP-8 (a) respectively issued vide Chapter XIII of The Telecom Manual. Inspection By-Site Engineer.
Blowing of OFC Cable in HDPE duct by mechanical system as per instruction of Railway engineer's representative at site. Inspection by-Site Engineer
Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON/1.1/97-A) so as not to form a drain 0.3 Mtrs. Wide & 1Mtr. Deep on 3 both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil, It also includes clearance of routes of trees & bushes. Lesser depth due to site condition shall be paid proportionately only after taking permission from atleast JAG officer Inspection by-Site Engineer
Cutting of all type of platforms,trenching & excavation of depth of 300 mm x 300 mm wide approx.and refilling after laying of RCC/DWC/GI pipe in the trench and refilling and concreting it 4 afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of 0.05 Mtrs. thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO Dr.No.SDO/Cable laying/008, issued vide RDSO Document No.RDSO/SI/G/2010 Ver 1.1 Dt.4.2.2014 or latest. Inspection By-Site Engineer
Laying of Data cable/Communication cable/ Power cable etc. in PVC conduit pipe/ PVC casing caping with all fittings and accessories as per instructions of consignee.Inspection by-Site Engineer"
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .