| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹37.9 L+₹69,027 (1.85%)Rejected-Finance | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹43.7 L+₹6.5 L (17.5%)Rejected-Finance | L3 | Rejected-Finance Not L1. |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Nov 2022, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF SOLAR WATER HEATER, GEYSER AND VARIOUS WATER SUPPLY E/M INSTALLATION AT AF-I UNDER GE (AF) JAMNAGAR NO.2
2022_MES_556397_1
8382/E8
Open Tender
Miscellaneous Works
Item Rate
300 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹70,000
Yes
24 Nov 2022
7 Oct 2022
5 Nov 2022
7 Oct 2022
4 Nov 2022
21 Oct 2022
Amount
Comprehensive maintenance of storage type electric water heater (geyser) comprising of the following checks/test including repair to unsv parts/components at different locations under GE (AF) Jamnagar No.2. (i) Taking down geysers from existing position after disconnecting all electrical & water supply connection. (ii) Opening / dismantling & cleaning of all parts & checking for its serviceability. (iii) Cleaning / descaling of inner tank with descaling solution & water leakage testing of tank & rectification of leakage.Testing of thermostat for serviceability. (iv) Checking of pressure release valves & non return valve etc. to ensures free movement / smooth operation of these components. (v) Checking of overflow / vent pipes and removing blockages / obstructions if any. (vi) Reassembling the geyser, replacement of minor spare part such as nut, bolt, screw, rubber packing etc & refixing in same position, reconnecting with electric & water supply connection complete all as specified and directed.
Note: All major defective unserviceable components such as thermostat, storage tank, heating elements, safety valves etc required for replacement shall be measured and paid separately as supply only under respective items of this BOQ, however quoted rates shall be deemed to includes for minor spare parts such as nut- bolts, screw, glands, packing etc.The following capacity of storage water heater are catered for as under:-
(a) 25 Ltr Capacity
(b) 50 Ltr Capacity
Supply only thermostats ISI marked suitable for 25 / 50 litres capacity geyser complete all as specified and directed. Make : ABC / Speer Hot / Crown / Power Pack
Supply only of safety valve / high pressure release valve ISI marked suitable for geyser of any capacity complete all as specified and directed.
Supply only heating element of 1 or 1.5 KW capacity including rubber washers ISI marked as per sample for existing complete all as specified and directed. Make : ABC / Speer Hot / Crown / Power Pack
Supply only heating element of 2 KW capacity including rubber washers ISI marked as per sample for existing complete all as specified and directed. Make : ABC / Speer Hot / Crown / Power Pack
Supply only storage tank made out of copper sheet and confirming to IS- 2082 (1973), suitable for 25 litres capacity geysers complete all as specified and directed.
Supply only storage tank made out of copper sheet and confirming to IS- 2082 (1973), suitable for 50 litres capacity geysers complete all as specified and directed.
Supply only apparatus plate suitable for 25 litres capacity geysers as per sample for existing item complete all as specified and directed.
Supply only apparatus plate suitable for 50 litres capacity geysers as per sample for existing item complete all as specified and directed.
Supply only 15 mm dia PVC flexible connection pieces with PTMT hexagonal adopters and washer at both sides, 450 mm long complete all as specified and directed.
Supply only brass chromium plated connection pieces with brass hexagonal adopters and washer at both side, suitable for 15 mm dia pipe and 450 mm long complete all as specified and directed.
Supply only brass non return valve 15 mm dia, ISI marked suitable for geysers complete all as specified and directed.
M&L for insulation material (Glass wool) for geysers of any capacity including removing old insulating material all as per manufacture instruction complete all as specified and directed.
Material and labour painting of Geyser outer body cover blades by scrapping of old paint, filling of cavities formed,preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES /SM No with appropriate size letters using black paint complete all as specified and directed. The painting shall be carried out to following cap of geysers:-
(a) 25 Ltr cap
(b) 50 Ltr cap
S&F in repair round cable PVC insulated, PVC sheathed, with 3 core copper conductor of size 2.5 Sqmm, ISI marked & connecting complete all as specified and directed.
Supply and fix on wall/ ceiling/roof or laying in trenches 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc complete and connecting to water supply pipe line including taking down old tubing, complete all as specified and directed. Note : Earthwork where required shall be measured and paid separately.
Supply and fix in repair 15 mm size Angular cock, cast copper alloy chromium plated, screwed down high pressure with capstan head, screwed both ends for iron pipe or unions, complete all as specified and directed. Make : Jaquar Cat No.CON-053K or equivalent Plumber, Hindware
Supply and fix in repair 15 mm size bib cock, cast copper alloy chromium plated , screwed down high pressure with capstan head, screwed both ends for iron pipe or unions, complete all as specified and directed. Make : Jaquar Cat No.CON-037KN or equivalent in plumber, Hindware
Periodical maintenance / servicing of solar water heater, flat plate collector type/ glass tube collector type, storage type with electrical backup of capacity 100 - 300 litres, as per manufacturer instruction comprising of the following works at different locations at GE (AF) Jamnagar. (a) Complete cleaning of solar system, removing of dirt dust etc. (b) Cleaning of heating surface glass with glass cleaning solution. (c) Opening of cold & hot water connection draining out deposited water removing of mud turbidity etc & cleaning with fresh water. (d) Checking of Non return valve, Electrical backup system & sacrificial anode & tighten the connection. (e) Checking of glass holding tube joint & rectification of leakage. (f) Replacement of unserviceable spare part.Note: (i) Preventive maintenance shall be carried as per direction of Engr-in-charge. (ii) Unserviceable spares parts will be measured & paid separately as supply only. (iii) Work shall be executed through Authorised service technician of Tata Solar BP / Delta / Red ren(iv) Contractor shall submit the documentary evidence of Authorised service technician for the approval of GE before commencement of work.
Supply only solar glass tube suitable for glass tube collector of following size and cap
(a) 58 mm dia and 1800 mm long
(b) 58 mm dia and 2100 mm long
(c) 48 mm dia and 1800 mm long
Supply only Electrical back of capacity 2 KW, 230 V supply, with thermostat suitable for glass tube collector type solar water heater complete all as specified and directed.
Supply only Electrical back of capacity 3 KW, 230 V supply, with thermostat suitable for glass tube collector type solar water heater complete all as specified and directed.
Supply only outer side solar washer (black) "O" ring glass tube type suitable for glass tube collector type solar water heater complete all as specified and directed.
Supply only outer side solar tube cap for collector ( Plastic ) suitable for tube type solar water heater complete all as specified and directed.
Supply only Inner side solar tube cap for collector ( Plastic ) suitable for tube type solar water heater complete all as specified and directed.
Supply only Hot water tank for glass tube collector type water heating system of following capacity :-
(a) for 100 Ltr cap solar water geyser
(b) for 200 Ltr cap solar water geyser
(c) for 300 Ltr cap solar water geyser
Supply only Back support for following sizes:-
(a) 100 Ltr cap solar water geyser
(b) 200 Ltr cap solar water geyser
(c) 300 Ltr cap solar water geyser
Supply only stand for following size:-
(a) 100 Ltr cap solar water geyser
(b) 200 Ltr cap solar water geyser
(c) 300 Ltr cap solar water geyser
M&L for Chemical cleaning of tube by providing chemical & removing all scale / dirt / dust etc as per manufacturer's instruction complete all as specified and directed.
M&L for Chemical cleaning of tank by providing chemical & removing all scale / dirt / dust etc as per manufacturer's instruction complete all as specified and directed.
M&L for fabrication of staging for fixing of tank on roof for solar water heater up to 2.5 metre height from roof top, fabricated with mild steel angle, flat, tee etc (using steel section of grade Fe-290 Grade 165) confirming to including nuts, bolts, washers, welding, drilling holes for bolts, painting over all two coat synthetic enamel paint over one coat of primer, and taking down / dismantling of old staging complete all as specified and directed.
S&F in repair 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed to water tank. (Minimum weight 455 grams) complete all as specified and directed.
Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 5 of SSR of part-I (1991) complete all as specified and directed.
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 10 Amp MCB SP, complete all as specified and directed. Make : Legrand cat part No : 607841 or equivelent of L & T, Schneider etc
M&L Sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed of the following sizes of cables:-
Using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including PVC casing and capping shall be measured as one unit
Using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire Note :2runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable in and including PVC casing and capping shall be measured as one unit
Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 1.5 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including PVC casing and capping shall be measured as one unit
Supply and fix 500 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position etc complete all as specified and directed.
Supply and fix 250 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position etc complete all as specified and directed.
S&F in repair 15 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed to HDPE water tank complete all as specified and directed.
S&F in repair 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed to HDPE water tank complete all as specified and directed.
Supplying and laying in replace of CPVC pipes SDR 11 & plain CPVC SDR 11 of 20 mm dia fittings with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, including clamps and all fittings and fixtures complete all as specified and directed. Make Supreme/Prince.
S&F in repair 20 Amp three pin top metal clad suitable for industrial socket, complete all as specified and directed. Make-Havells (Crabtree)/Anchor/Legrand.
S&F in repair 20 Amp three pin metal Plug suitable for industrial socket, complete all as specified and directed. Make : Havells (Crabtree)/Anchor/Legrand.
S&F in repair PVC plug top 15 Amps, single phase, 240 Volts complete all as specified and directed. Make : Havells (Crabtree)/Anchor/Legrand.
M&L for MCB single pole, 5 to 32 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
Repair / Maintenance / updating including operation and regular maintenance of the Automatic water suppply system excluding spares. Carrying out complete maintenance/ servicing/ Repairs with establishing Ladder Logic Programming as required of all the sub system viz. PLC based control panels (with all the Morris), breakdown maintenanace all as specified and directed by Engineer-in-Charge on following location:- Establishing Ladder Logic programming Automation Control Panel at location: Main Pump House, Pump House No.2, NEU Pump House, Bedi Well Pump House No.1 & 2, Bedi OHT, OHT No.3, OHT No.4, OHT No.5, OHT No. 7&8 and MIMIC Panel at Main Pump House.
Note : (i) Unit rate quoted by tenderer is of checking of system fortnightly and necessary servicing, repair and daily printing log sheets data on hourly basis and to be submitted to EIC the register will be maintained to that effect. (ii) In addition to above specific emergency complaints from time to time shall be attended after receiving the same.(ii)The work has to be carried by OEM M/S Recktronic Devices & Systems or through their authorized agent / MOU documents of authorization shall be provided before execution of work by quoted by tenderer. (iv) The job is excuted as per direction of EIC.
Disconnecting following spares for repair work, cleaning, greasing for wear and tear and complete servicing, lathing and Refixing complete repair works. (a) Pressure Switch / flow switch (b) Solenoids Valve / Priming Valves (c) Water Megnetic level sensor (d) Ultrasonic level sensor (e) 80 mm to 300 mm bore Motorised valve
Sevicing of the Automatic water supply system excluding spares but including maintenance and carrying out complete repairing, servicing and maintenance with establishing Ladder Logic Programming as required of all the sub systems viz. PLC based control panels with all the Morris, breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts / new parts if any including the following Establishing Ladder Logic programming Automation Control Panel at existing locations.
S&F in repair single phase preventer, AC, 415 V including commissioning & testing including taking down existing single phase preventer complete all as specified and directed. Make: Minilec Model 1:VSP D2 / L&T / C&S
S&F in repair relay with base 4 C/O / 24 V DC / 240 V DC complete all as specified and directed. Make: LEONE / IDEC
S&F in repair GPRS communication modem alongwith suitable patch chord and mounting Mrories compatible with existing system complete all as specified and directed. Make: Motorola / Visiontek / LEO / Meastro Heritage
S&F in repair LED type Red /Yellow /Green indicating lamp complete all as specified and directed. Make: ESBEE / TEKNIC / TELEMEACHNIQUE
S&F in repair PLC (Programmable Logic Controller) comprising of Main Controller, MMI with display, input / output complete all as specified and directed. Make: Unitronics / Mitsubishi / Electric India / Siemens
S&F in repair water lever controller PCB-5/10 level complete all as specified and directed. Make: SPLASH / RDS / ICS
S&F in repair push botton with LED indicator, 240 V AC colour Red/Yellow/Green complete all as specified and directed. Make: ESBEE / TEKNIC / TELEMEACHNIQUE
S&F in repair Flow switch including taking down existing complete all as specified and directed. Make: Danfoss / Rapid Control
S&F in repair solenoid valve 10mm/15mm/20mm bore 230 V AC complete all as specified and directed. Make: Rotex Cat Part No. 9210B61/BR/54/BN/BSP or equivalent in Avcon / Johnson Controls / Danfoss
S&F in repair coil for solenoid valve 10mm/15mm/20mm bore 230 V AC complete all as specified and directed. Make: Rotex Cat Part No. 9210B61/BR/54/BN/BSP or equivalent in Avcon / Johnson Controls / Danfoss
S&F in repair Magnetic level switch complete all as specified and directed. Make: RDS Cat Part No. MG 03 or equivalent in Mahalaxmi / Crysta
S&F in repair Pressure switch 0-10 kg/sqcm including taking down existing complete all as specified and directed. Make: Indfoss Cat Part No. P220 7MF1567-3CA00-1GA1 or equivalent in Danfoss
S&F in repair Ultrasonic Level Transmitter at Pure Water Sump (for measurement of level in pure water sump / OHT) having 0-5 meters range, 0.5% minimum Accuracy, 24 V DC supply Voltage and 4-20 mA output including taking down existing complete all as specified and directed. Make: Banner Cat Part No. QT50 ULB or equivalent in ABB / E& H / Krohne Marshall
S&F in repair 80 mm dia Electric motor suitable for actuator including taking down existing motor complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair 100 mm dia Electric motor suitable for actuator including taking down existing motor complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair 150 mm dia Electric motor suitable for actuator including taking down existing motor complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair 200 to 250 mm dia Electric motor suitable for actuator including taking down existing motor complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS spiral gear for gear box or actuator suitable for 80 mm dia butterfly valve including taking down existing spiral gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS spiral gear for gear box or actuator suitable for 100 mm dia butterfly valve including taking down existing spiral gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS spiral gear for gear box or actuator suitable for 150 mm dia butterfly valve including taking down existing spiral gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS spiral gear for gear box or actuator suitable for 200 to 250 mm dia butterfly valve including taking down existing spiral gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS sector gear for gear box or actuator suitable for 80 mm dia butterfly valve including taking down existing sector gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS sector gear for gear box or actuator suitable for 100 mm dia butterfly valve including taking down existing sector gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS sector gear for gear box or actuator suitable for 150 mm dia butterfly valve including taking down existing sector gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair MS sector gear for gear box or actuator suitable for 200 to 250 mm dia butterfly valve including taking down existing sector gear complete all as specified and directed. Make: Marsh / Ritetork / Rotork
S&F in repair 50mm dia butterfly valve cast iron body confirming to IS 13095, class PN 1.6, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc including taking down old butterfly valve compete all as specified and directed. Make: AUDCO / VIRGO / L&T / INTERVALVE
S&F in repair 80mm dia butterfly valve cast iron body confirming to IS 13095, class PN 1.6, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc including taking down old butterfly valve compete all as specified and directed. Make: AUDCO / VIRGO / L&T / INTERVALVE
S&F in repair 100mm dia butterfly valve cast iron body confirming to IS 13095, class PN 1.6, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc including taking down old butterfly valve compete all as specified and directed. Make: AUDCO / VIRGO / L&T / INTERVALVE
S&F in repair 150mm dia butterfly valve cast iron body confirming to IS 13095, class PN 1.6, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc including taking down old butterfly valve compete all as specified and directed. Make: AUDCO / VIRGO / L&T / INTERVALVE
S&F in repair 200 / 250mm dia butterfly valve cast iron body confirming to IS 13095, class PN 1.6, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc including taking down old butterfly valve compete all as specified and directed. Make: AUDCO / VIRGO / L&T / INTERVALVE
S&F in repair Motorised actuator suitable for 50 / 80 mm dia butterfly valve including taking down existing motorised actuator compete all as specified and directed. Make: Marsh / Hassel Hoffner / Ritetork
S&F in repair Motorised actuator suitable for 100 mm dia butterfly valve including taking down existing motorised actuator compete all as specified and directed. Make: Marsh / Hassel Hoffner / Ritetork
S&F in repair Motorised actuator suitable for 150 mm dia butterfly valve including taking down existing motorised actuator compete all as specified and directed. Make: Marsh / Hassel Hoffner / Ritetork
S&F in repair Motorised actuator suitable for 200 mm dia butterfly valve including taking down existing motorised actuator compete all as specified and directed. Make: Marsh / Hassel Hoffner / Ritetork
S&F in repair Motorised actuator suitable for 250 mm dia butterfly valve including taking down existing motorised actuator compete all as specified and directed. Make: Marsh / Hassel Hoffner / Ritetork
S&F in repair Capacitor & Resistor (RC Circuit) for Actuator suitable for 50 / 80 / 100 / 150 / 200 / 250 / 300 mm dia butterfly valve including taking down existing Capacitor & Resistor compete all as specified and directed.
S&F in repair Hand wheel for actuator suitable for 50 / 80 / 100 mm dia butterfly valve including taking down existing Hand wheel compete all as specified and directed.
S&F in repair Hand wheel for actuator suitable for 150 / 200 / 250 / 300 mm dia butterfly valve including taking down existing Hand wheel compete all as specified and directed.
S&F in repair limit switch for Actuator suitable for 50 / 80 / 100 / 150 / 200 / 250 / 300 mm dia butterfly valve including taking down existing limit switch compete all as specified and directed.
S&F in repair top cover for actuator suitable for 50 / 80 / 100 / 150 mm dia butterfly valve including taking down existing top cover compete all as specified and directed.
S&F in repair top cover for actuator suitable for 200 / 250 / 300 mm dia butterfly valve including taking down existing top cover compete all as specified and directed.
S&F in repair SMPS having input 230 V AC and output 24 V DC including taking down existing SMPS compete all as specified and directed. Make: NHP / Telemehanique
S&F in repair external antenna for PLC to Modem Gain 9db compete all as specified and directed. Make: Pentagon / Cherry
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .