| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹6.6 LAccepted-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | ₹6.6 L Quoted ₹6.8 L | 1st | Accepted-AOC L1 |
| 2 | 2nd₹7.4 L+₹56,805 (8.32%)Rejected-AOC | ₹7.4 L+₹56,805 (8.32%) | 2nd | Rejected-AOC L2 |
| 3 | 3rd₹7.8 L+₹97,955 (14.4%)Rejected-AOC SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹7.8 L+₹97,955 (14.4%) | 3rd | Rejected-AOC L3 |
| 4 | 4th₹8.2 L+₹1.3 L (19.6%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.2 L+₹1.3 L (19.6%) | 4th | Rejected-AOC L4 |
| 5 | 5th₹8.4 L+₹1.6 L (23.7%)Rejected-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹8.4 L+₹1.6 L (23.7%) | 5th | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | M/S Garhwal Enterprises L1 | Bedi Refrigeration Works L4 | A ONE BUILDERS AND ENGINEERS L5 | MUNI RAM L2 | anant enterprises L3 | AJAY KUMAR CONTRACTOR L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. | 60 | Per Point | 10 ₹600 | 10 ₹600 | 10 ₹600 | 5 ₹300 Lowest | 20 ₹1,200 | 10 ₹600 |
| 2.00 | Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 2.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 25 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
Make - Havells / Polycab / Gloster / SCI or any other equivalent makes as approved by AGE I Lansdowne. | 60 | Per Point | 300 ₹18,000 Lowest | 500 ₹30,000 | 500 ₹30,000 | 450 ₹27,000 | 500 ₹30,000 | 500 ₹30,000 |
| 3.00 | S&F Modular Socket Outlet 6A/16A - 2/3 pin combined 2 module ISI marked complete all as specified and directed. | 60 | Each | 130 ₹7,800 | 140 ₹8,400 | 100 ₹6,000 | 150 ₹9,000 | 95 ₹5,700 Lowest | 150 ₹9,000 |
| 4.00 | M & L Modular Switch, 16 A, 1 Way, 1 Module ISI Marked complete all as specified and directed. | 60 | Each | 110 ₹6,600 | 65 ₹3,900 | 100 ₹6,000 | 110 ₹6,600 | 50 ₹3,000 Lowest | 110 ₹6,600 |
| 5.00 | Taking down the unserviceable water storage heater of 25/50ltrs capacity, any type and make, refixing the same after cleaning the scaling deposited in the inner container and water pipe complete all as specified and directed. | 125 | Each Job | 110 ₹13,750 | 100 ₹12,500 Lowest | 100 ₹12,500 Lowest | 220 ₹27,500 | 160 ₹20,000 | 200 ₹25,000 |
| 6.00 | Supply and fix in repair of Non return valve 15mm dia made of bronze suitable for existing size of geysers ISI marked heavy duty complete all as specified and directed. | 25 | Each | 210 ₹5,250 | 200 ₹5,000 Lowest | 200 ₹5,000 Lowest | 310 ₹7,750 | 200 ₹5,000 Lowest | 400 ₹10,000 |
| 7.00 | Supply and fix in replacement of Water heating element of 1.5 KW capacity for geysers in Triangular/ Cup type / Round type / As per existing shape and size complete all as specified and directed. | 100 | Each | 500 ₹50,000 | 370 ₹37,000 | 400 ₹40,000 | 330 ₹33,000 | 300 ₹30,000 Lowest | 320 ₹32,000 |
| 8.00 | Supply and fix in repair Water heating element of 2 KW capacity for geysers in Triangular/ Cup type / Round type /As per existing shape and size complete all as specified and directed. | 100 | Each | 500 ₹50,000 | 370 ₹37,000 | 400 ₹40,000 | 330 ₹33,000 Lowest | 350 ₹35,000 | 400 ₹40,000 |
| 9.00 | Supply and fix in repair thermostat for geysers in Triangular/ Cup type / Round type /As per existing shape and size complete all as specified and directed. | 100 | Each | 80 ₹8,000 Lowest | 90 ₹9,000 | 100 ₹10,000 | 180 ₹18,000 | 125 ₹12,500 | 300 ₹30,000 |
| 10.00 | Supply and fix in repair indicator bulb (Red & Green) for geysers of approved make complete all as specified and directed. | 30 | Set of Two | 15 ₹450 Lowest | 30 ₹900 | 20 ₹600 | 40 ₹1,200 | 20 ₹600 | 60 ₹1,800 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 Aug 2025, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR AND MAINT OF GEYSERS, EXHAUST FANS AND ALLIED WORKS AT LANSDOWNE AND KOTDWARA UNDER AGE (I) LANSDOWNE.
2025_MES_721864_1
9046/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
29 Sept 2025
22 Jul 2025
21 Aug 2025
23 Jul 2025
19 Aug 2025
6 Aug 2025
Amount
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 2.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 25 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Make - Havells / Polycab / Gloster / SCI or any other equivalent makes as approved by AGE I Lansdowne.
S&F Modular Socket Outlet 6A/16A - 2/3 pin combined 2 module ISI marked complete all as specified and directed.
M & L Modular Switch, 16 A, 1 Way, 1 Module ISI Marked complete all as specified and directed.
Taking down the unserviceable water storage heater of 25/50ltrs capacity, any type and make, refixing the same after cleaning the scaling deposited in the inner container and water pipe complete all as specified and directed.
Supply and fix in repair of Non return valve 15mm dia made of bronze suitable for existing size of geysers ISI marked heavy duty complete all as specified and directed.
Supply and fix in replacement of Water heating element of 1.5 KW capacity for geysers in Triangular/ Cup type / Round type / As per existing shape and size complete all as specified and directed.
Supply and fix in repair Water heating element of 2 KW capacity for geysers in Triangular/ Cup type / Round type /As per existing shape and size complete all as specified and directed.
Supply and fix in repair thermostat for geysers in Triangular/ Cup type / Round type /As per existing shape and size complete all as specified and directed.
Supply and fix in repair indicator bulb (Red & Green) for geysers of approved make complete all as specified and directed.
Supply and fix in replacement of spring loaded Air-release safety valve 15mm dia made of brass for geysers as per existing shape and size of approved make complete all as specified and directed.
Supply and fix in replacement of inner container made of stainless Steel/ Mild Steel for 25 ltrs capacity of approved make as per existing size / guage complete all as specified and directed.
Supply and fix in replacement of inner container made of stainless Steel/ Mild Steel for 50 ltrs capacity of approved make as per existing size / guage complete all as specified and directed.
Supply and fix in replacement of bottom cover in two pieces made of GI sheet for geysers duly painted in required/existing size and shape suitable for 25/50 ltrs capacity water storage heater complete all as specified and directed.
Supply and fix in replacement of fancy type Chromium plated/Brass stop cock CP with capston head, heavy duty of 15mm bore, fixed to iron pipe or brass ferrule complete all as specified and directed.
Supply and fix in replacement of brass assembly heavy duty suitable for 25 ltrs geysers of any make and as per sample size complete all as specified and directed.
Supply and fix in replacement of brass assembly heavy duty suitable for 50 ltrs Geyser of any make and as per sample size complete all as specified and directed.
Supply and fix in replacement of PVC connection heavy duty 450mm long suitable for 15mm bore pipe with 2 Nos of brass nut and washer for geysers complete all as specified and directed.
S&F in replacement of medium grade GI water tubing size of 15 mm dia conforming to IS-1239 Part-I-1979 including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc ,fixed to walls and ceilings or laid in floors complete all as specified and directed.
Dismantling of exhaust fan 450/380 mm sweep of any make/ model, opening for cutting, taking out existing unserviceable winding wire, rewinding with super enamel copper wire of existing gauge, including varnishing and insulating material with washer, split pin, checknut, hanging clutch, condenser clamp, assembling,with required flexible wire .5 mtr and testing complete all as specified and directed.
All as per Srl item 20 above but for exhaust fan 350/300 mm sweep. complete all as specified and directed..
All as per Srl item No 20 above but for exhaust fan 250/200 mm sweep. complete all as specified and directed.
Taking down exhaust fans of any size, removing and cleaning of dust properly, oiling and greasing of bearing with and including replacement of washer, new split pin & any other minor spare parts such as new screw, checknut, pin etc and refixing in position, connecting, testing complete all as directed.
S&F in replacement of condenser 3.15 MFD exhaust fan complete all as specified and directed.
M&L Spray painting of Exhaust fans of any size including fan blades, after scrapping and cleaning old painted surfaces, with enamel paint complete all as specified and directed.
S&F in replacement of plug top 3 pin, 15 Amp, 230 volts complete all as specified and directed.
S&F in replacement of Metal Clad Plug Top 20 Amp, 230 volts suitable for MCB DB plug & socket SPN 20 Amps ISI Marked complete all as specified and directed.
S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter,AC single phase 230/240 Volt ,50HZ,RPM 1200,Copper winding of 250 mm sweep complete including making hole and making good the disturbed sufaces of wall all complete all as specified and directed. Note:- Old Exhaust fan deposit at MES Store Yard.
S&F Exhaust fan, Steel body complete with louvers shutter,AC single phase 230/240 Volt ,50HZ,RPM 1200,Copper winding of 300 mm sweep complete including making hole and making good the disturbed sufaces of wall all complete all as specified and directed. Note:- Old Exhaust fan deposit at MES Store Yard.
S&F in repair Wall Bracket light fitting (Bldg Security light) 20W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts, lumen efficiency >120 lumen Per watt, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape, not less than 1.0 m long including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Supply and installation of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass coating inside the tank alongwith heating element with anticorrosive magnesium anode, NRV, thermostat, indicator and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with G.I. hexagonal adapters/ nuts on both side for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed. Note:- Old Geyser deposit at MES Store Yard.
MUNI RAM (BID ID -3398812)
anant enterprises (BID ID -3388912)
Bedi Refrigeration Works (BID ID -3390572)
A ONE BUILDERS AND ENGINEERS (BID ID -3391413)
AJAY KUMAR CONTRACTOR (BID ID -3396595)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .