| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L1 | Accepted-AOC Admitted Found Reasonable for Acceptance | |
| 2 | L2₹14.3 L+₹1.1 L (8.18%)Rejected-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-AOC Rejected L1 being accepted | |
| 3 | L3₹16.2 L+₹2.9 L (22.2%)Rejected-AOC JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | L3 | Rejected-AOC Rejected L1 being accepted |
Tender Value
₹15.5 L
EMD Value
₹30,980
Closing Date
8 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2021_MES_467126_1
GE (ARMY) TVM 9399/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹30,980
Yes
16 Nov 2021
11 Aug 2021
10 Sept 2021
12 Aug 2021
8 Sept 2021
25 Aug 2021
12 Aug 2021 - 24 Aug 2021
60 days
Amount
M&L for Excavation in trenches n.exc 1.5mtr wide and n.exc 1.5mtr in depth and getting out in hard/ dense soil for cable/pipe/poles, trimming the sides forming bottom surface to required levels complete all as specified.
Returning filling in & including spreading leveling watering and well ramming 20 cm thick using reddled earth as protection to cable and balanced depth using excavated earth in layers not exc 25C M all as specified.
Removing excavated materials (surplus soil) to a distance not exceeding 50m in distance and depositing where directed at level n exc 1.5m above the starting point all as specified and directed.
M & L brick common burnt clay sub class `B; lying flat on cable in trenches size of brick 230 x 115 x 75mm all as specified.
Supply and fix in repair of Danger notice plate 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with FI MS clamps 25x3mm with, bolts and nuts of approved size, for HT, 20 X 15 cm size all as specified and directed.
S & F in repair lightening arrestor nonlinear type complete with all fittings transmission class discharge capacity 19 Kilo Amps suitable for 11000 volts complete all as specified and as direcetd.
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregates as in foundationof poles complete all as specified and as directed.
M & L PCC (1:2:4) type B1 using 20mm graded stone aggregate for copping of poles all as specified
Laying only in replacement under ground PVC insulated XLPE cable 1100 volts 150/95/70/50/35/25/16 sqmm 3.5/4 core . Note : The cable mentioned in Ser No 09 will be issued under Sch `B' free for laying.
Supply & Fix replacement of switch air break gang operated device with drop out fuse tripple pole, mechanically operated mounted on insulator and steel frames vertical/Horizontal with operating mechanism, from ground level of current rating upto 400 Amps complete all as specified. Make:Jaipuria brothers or equivalent
M&L for checking out servicibillity and function of air brake switch applying petrolium jelly in all moving contacts and binding of conductor of suitable size at all structures including tightening all connections to lightining arrestor /drop out fuse /insulators complete all as specified and as directed.
Dismantling of old unserviceable PCC poles 9 mtr long complete.
S & F in replacement prestressed concrete pole 9 Mtr long 102 x 172 mm at top and 102 x 279mm at bottom class-10 all as specified.
Dismantling stay assembly complete including insulator,stay strand all as specified and directed.
M &L Stay assembly complete with accessories 16mm Dia Stay rod as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately)
S & F loop type insulator vitorious porcelain white or brown or green large size with overall dimension 90 x 140mm clearance hole 25mm.
S & F galvanised stay strand of size 7/3.15mm complete.
Dismantling of ACSR conductor of any size from LT OH line complete
S & F ACSR conductor sqirrel/weasel/ferret all as specified & directed.
Dismantling earth wire and removed from site all as specified.
S & F galvanised steel earth wire/ craddle guard of size 4.00mm dia complete all as specified .
Restringing ACSR conductor/squirrel/weasel/ferret of conductors 2/5 wires per span of upto 50 RM complete including tightening of conductors all as directed.
Dismantling insulator any type/size complete.
S & F pin type porcelian & Vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron nut 150mm height 150mm dia for 11000 volts complete.
S & F disc type insulator porcelain vitreous 145mm high and 255mm dia ball & socket type white, green, or brown single disc assembly for tension with tension clamp for conductor working pressure 11000 volts grade complete.
S & F shackle type porcelain vitreous white or brown green insulator 100 mm height and max dia 115 mm including galvanised mild steel staps, washers, insulators bolts nuts for working pressure 1100 volts complete.
S & F pin type procelain, vitreous white or brown, green insulator, including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100mm height 65mm dia for 1100 volts complete.
Dismantling GI pipe light grade size 50mm dia from trenches poles complete.
Dismantling GI pipe light grade size 80mm dia from trenches poles complete.
S & F laying GI pipe light grade with all fittings complete fixed to walls/poles laid in trenches for cable protection 50mm dia.
All as per item No 30 above but 80mm dia complete.
M & L in replacement for cross arms , supports clamps and back plate, fabricated from structural steel section including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shapes or sizes as indicated, including one coat of primer above two coat of synthetic enamel paint.
M&L in replacement for earthing galvanised steel earth plate electrode 600X600X6.30mm thick burried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate less than 1.5 mtr below normal ground level) connected to GI strip 25x4mm by means of bolts, nuts, check nuts, and washers, of galvanised iron or steel including GI pipe light grade 40 mm bore for protection of earth lead,GI funnel and wire mesh etc complete all as shown in Electrical plate no 3 of SSR 2009(part- I)including necessary excavation earth work, form work.earth pit of size 450X450X300 mm of PCC M-15 (Nominal mix)using stone aggregate earth pit cover of PCC and 20 mm bore light grade GI pipe for watering and charcoal dust,common salt, and connected to test point 7.5 mtr from earth pit including testing complete all as specified and as directed.
34.M&L cutting/Trimming of tree branches 3 mtr all arround apart from LT O/H line,two pole/ 4 pole structures,substations,cleaning of LT/OH conductor line and removing trimmed tree branches from site all as specified and directed.
M & L for replacement of cable jointing kit straight through for earthed grade cable heat shrinkable suitable for 3 core 11 KV XLPE cable size 120-185 Sq mm complete. Make - Rechyem/Denson
M & L for replacement of cable jointing kit straight through for earthed grade cable heat shrinkable suitable for 3 core 11 KV XLPE cable size 95 Sq mm complete. Make - Rechyem/Denson
M & L for replacement of cable end termination kit with all accessories for earthed system grade cable heat shrinkable outdoor type suitable for 3 core 11 KV XLPE cable size 120-185 Sq mm complete. Make - Rechyem/Mseal/Danson
M & L for replacement of cable end termination kit with all accessories for earthed system grade cable heat shrinkable outdoor type suitable for 3 core 11 KV XLPE cable size 95 Sq mm complete. Make - Rechyem/Mseal/Danson
M & L for replacement of cable jointing kit straight through heat shrinkable type(tubular sleeve version) suitable for LT 1100 volts 3.5/4 core 10-16 sqmm.Make: Reychem RPG
All as per item No.39 above but 3.5 core 25-50 sqmm.
All as per item No.39 above but 70-150 Sq mm.
All as per item No 39 above but 185-300 Sq mm.
Taking out unserviceable MCCB from existing panel board & Supply and fix new MCCB, 3 pole, 100 Amp, 16 KA ,ICS=ICU=100% suitable for existing panel board by cutting welding as per site condition complete.
All as per item No 43 above but 125 Amp 25 KA
All as per item No 43 above but 200 Amp 25 KA
All as per item No 43 above but 250 Amp 25 KA
All as per item No 43 above but 400 Amp 36 KA
Taking out unserviceable MCB TPN from existing panel board & Supply and fix new MCB TPN 63 Amp 10 KA suitable for existing panel board by cutting welding as per site condition complete.
S & F seperator/ O/H line spacer for LT O/H line conductor 2 wire/4 wire (separate 2 way and 4 way) complete all as specified.
Removing grass and bushes growing at sub stn and keep the sub stn yard neat and clean complete all as specified and as directed . Note:-Unit rate quotated deemed to include to keep the installation neat and clean through out the period of contract Location S/S No1,2, 3,4,5,6, 7 ,8,9,10, Army school S/S and KV school S/S .and NFS sub station (Approximate area 800 sqm) Note:Contractor shall keep all the sub station neat and clean throughout the contract period and each job will be completed once in three month.
S&F Automatic Power Factor Correction (APFC) Panel(out door ) in repair 5 step for 3 Phase, 415 V & 50 Hz and system of capacity 50 KVAR with APFC meter, incoming MCCB of capacity 100 A suitable relay system internal wiring,powder coated panel CPRI approved ,IP 66 protection dust and vermin proof complete including necessary foundation work all as directed by engineer in charge.Make :Havells or equivalent .
Supply and fix in replacement , installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), for BDE Officer mess, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps rating installed on porcelain insulators . The panel shall be dust and vermin proof, IP 65 class protection and made of 3 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm.The panel shall be mounted on suitable PCC foundation. The scope of work includes the following:-
53.Supply and fix in replacement , installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), for MH MT yard, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps rating installed on porcelain insulators . The panel shall be dust and vermin proof, IP 65 class protection and made of 3 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm.The panel shall be mounted on suitable PCC foundation. The scope of work includes the following:-
SUPER COOL
S L ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .