Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹31.8 L
EMD Value
₹63,500
Closing Date
9 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2026_MES_799520_1
8140
Open Tender
Civil Works
Item Rate
150 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
GE ARMY BARODA
₹63,500
Yes
19 Nov 2026
19 Nov 2026
10 Dec 2026
19 Nov 2026
9 Dec 2026
4 Dec 2026
19 Nov 2026 - 26 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 630 Amps, prewired with suitable size of copper cable/insulated copper strip for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
MCCB adjustable thermal and magnetic of 350 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 200 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(ii) MCCB adjustable thermal and magnetic of 160 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(iii) MCCB adjustable thermal and magnetic of 100 Amps, 4pole, 415 Volts, 16 KA, with rotary macanism - 01 Nos
(iv) MCCB adjustable thermal and magnetic of 63 Amps, 4pole, 415 Volts, 16 KA, with rotary macanism - 01 Nos
(v) MCB , TPN 'C' Series ,240V/415 V , 50HZ , 63 Amps 10 KA - 01 Nos
(vi) MCB , SPN 'C' Series ,240V/415 V , 50HZ , 63 Amps 10 KA - 02 Nos
(vii) MCB , SPN 'C' Series ,240V/415 V , 50HZ , 32 Amps 10 KA - 03 Nos
(viii) Blank space for MCCBs of same capacity - 01 Nos
(ix) Digital Multifuction meter with selector switch and three CT/PT site program of suitable ratio and capacity -01 Set
(x) LED Type Phase indicator lamps for three phases set of three -01 Nos
(xi) Selector switch - 03 Nos
(xii) Busbar chamber having insulated aluminium busbar, each suitable for 630 Amps for three phases and neutral -01 Set | 1 | Each | - | - |
| 2 | Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 720 Amps, prewired with suitable size of copper cable/insulated copper strip for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
MCCB adjustable thermal and magnetic of 400 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 350 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(ii) MCCB adjustable thermal and magnetic of 250 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(iii) MCCB adjustable thermal and magnetic of 160 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos
(iv) MCCB adjustable thermal and magnetic of 100 Amps, 4pole, 415 Volts, 16 KA, with rotary macanism - 01 Nos
(v) MCB , TPN 'C' Series ,240V/415 V , 50HZ , 63 Amps 10 KA - 03 Nos
(vi) MCB , SPN 'C' Series ,240V/415 V , 50HZ , 63 Amps 10 KA - 04 Nos
(vii) Blank space for MCCBs of same capacity - 01 Nos
(viii) Digital Multifuction meter with selector switch and three CT/PT site program of suitable ratio and capacity -01 Set
(ix) LED Type Phase indicator lamps for three phases set of three -01 Nos
(x) Selector switch - 03 Nos
(xi) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set | 1 | Each | - | - |
| 3 | M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system withMCCB adjustable thermal and magnetic of 200A ,36 KA ,4 pole, outdoor type, with digital volt amp meter ,double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .
Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed. | 2 | Each | - | - |
| 4 | Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanized earth lead wire 32 x 6 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).
Notes
(a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.
(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.
(c) If the testing result of earthing is not found below 3 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.
(d) Earthing work will be carried out in presence of MES representative. | 8 | Each | - | - |
| 5 | Supply and Fix in replacement of 40/45 watt LED post top lamp New generation IP 65, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source.T40WLED757PSYMTOPCvells , LPTO-40-CDL-Mor of Crompton ,LP02-501-X7-XX of Wipro
Note :- The warranty on light should be minnimum of 2 Years . | 12 | Each | - | - |
| 6 | Supply & Fix of 15 Watt LED based bollard light fitting with MS pipe housing with glare free PMMA diffuser, IP 65,H=100mm New generation energy saving and environmental friendly long life LED bolard light complete all as specified and directed.
Note :- (i) The warranty on light should be minnimum of 3 Years provided by contractor .
(ii) Necessary PCC work,including execavation deemed included in quoted rates. | 60 | Each | - | - |
| 7 | Supply and fix of 7 mtr Designer MS pole designed for Ornamental street light ,mounting with four numbers anchor bolts on foundation including double arm bracket for double mounting of drop down luminaries with inbuilt junction box(oval shape window) at the base of pole provision available for loop in& loop out complete all as specified and directed.
Note:- (i) Design should be approved by GE before procurement.
(ii) Foundation as per manufacturer drg. | 20 | Each | - | - |
| 8 | Supply and fix of energy efficient LED light 45 Watt IP 65 pendent mounting Ornamental road light aluminium die cast suitable for high efficency assymetric secondary lense ,operating voltage range 140V to 270V ,Operating temperature -10degree C to 50degree C,open and short circuit protection,reverse polarity protection,High voltage cut off at 310±20V and surge protection of 5KV Internal complete all as specified and directed.
Note :- The warranty on light should be minnimum of 3 Years provided by contractor | 40 | Each | - | - |
| 9 | M & L for replacement ,erecting & fixing in true vertical position steel tubular swaged pole type 410S P-31 ( 9.0 metre long ) confirming to IS 2713 with cast iron base plate finial taper plug, bolts, nuts and screws welded & reduced section & longitudinal weld through out entire length of pole including 2 coat of black bituminous paint upto GL level of pole & remaining exterior portion of the pole & two coat of aluminium paint over a coat of red oxide primer including excavation & earth work & PCC work complete all as specified &directed by Engr in charge. | 10 | Each Job | - | - |
| 10 | S&F of GI Pipe light grade 40 mm dia ISI marked on pole/ wall / laid in trenches/ bracket for street light fittings not less than 1.20m long and bent to shape as required incl necessary clamps , nut , bolts and washers all fittings complete all as specified and directed by Engr-in-charge. | 50 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tenderpages8140.pdf
Tender Documents • 0.47 MB
BOQ_897036.xls
BOQ • 1.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .