EE-II KNHED PWDte.
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata700073
Supply, Installation, Testing and Commissioning of HVAC system in CB Building Orthopaedic OPD Room No 8 at KMCH Kolkata.
2026_WBPWD_5079209_1
WBPWD/EE-II/KNHED/NIQ-47/ 2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹25,730
OFFICE OF THE EE KNHED PWDte.
12 Oct 2026
12 Oct 2026
29 Oct 2026
12 Oct 2026
27 Oct 2026
14 Oct 2026
14 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Part A:- EI Work
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (make-- KEI/Glostar/Havells)
2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire (for Loop Box to IDU ) | 84 | mtr | - | - |
| 2 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S
4.0 sqmm | 12 | Set | - | - |
| 3 | S & F PVC water proof looping cable box (make -Sintex, size--250X200X105 mm) having hinged type PVC top cover having 4 mm thick rubber gasket lining & earthing terminal etc .The box should comprising of 1 no. din rail for fixing of 415V, 63A, 4P MCB (make-- LK) and 63A 4 way Terminal bar etc. complete with all accessories as per direction of EIC. | 2 | Nos | - | - |
| 4 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (make-- KEI/Glostar/Havells)
a. 4 core 35 sqmm (from VTPN to Loop Box) | 122 | mtr | - | - |
| 5 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle) (from VTPN to Loop Box) | 122 | mtr | - | - |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 2 | Set | - | - |
| 7 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 252 | mtr | - | - |
| 8 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness | 96 | mtr | - | - |
| 9Part B:- SITC of AC machine Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. | |||||
| 9.1 | The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both
Capacity : 14HP
(make-- Voltas/Hitachi/Daikin/Mitshubishi Electric/ Carrier) | 2 | nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_5181727.xls
BOQ • 0.58 MB
2911.pdf
Tender Documents • 1.46 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .