Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.1 L+₹27,005.66 (0.91%)Rejected-AOC | L2 | Rejected-AOC Second Lowest | |
| 3 | L3₹34.2 L+₹4.4 L (14.7%)Rejected-AOC CHANGANACHERRY GENERAL ELECTRICAL WORK | ERNAKULAM | KERALA | 682001 | L3 | Rejected-AOC Third Lowest |
| Sl No | Description | Qty | Unit | Technocraft L2 | ELCON ELECTRICALS L3 | D SURESH L1 |
|---|---|---|---|---|---|---|
| 1.00Conversion to HT connection at Govt.ITI,Ettumanoor | ||||||
| 1.00 | OD203944/2024-2025:Supply, conveyance, installation, testing and commissioning of 315 KVA, 11KV/433V Indoor
type unitized sub station of IP class 54, with cast resin Transformer with 11KV VCB mechanically ON/OFF
on H.T.side, and TOD Meter,Metering CT and PT ,with Top/bottom entry cable box .The LT
Portion Shall include 1No 630A 4 pole 50KA isolation duty type MCCB with microprocessor based release with overload setting of 50-100% with inbuilt earth fault relay suitable size Neutral CT
with MC12 Relay on L.T. side. The HT portion consists of 1No 11KV, 630A, 350MVA VCB with 2 o/c relay with high set element one E/F relay with DC trip with interlock with main switch and mechanical ON/OFF, shunt trip coil for the remote operation. TOD metering facilities consists of 3Nos....../5A (or suggested by KSEB) 15VA, 0.2class accuracy cast resin CTs, 1No 3 phase 3 Limb 11KV/110V, 10VA, 0.2 class accuracy cast resin PTs. with protective fuses. 1No TOD meter 1No TOD meter test terminal block,(TOD meter and CTs, PTs unit compartment shall be so fabricated. So as to enable the KSEB authorities to seal it) and including arranging testing and installation of the same with KSEB testing Division. Transformer Portion consists of 315 K.V.A , 11 K.V/433V,
50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core
shall be made of high grade grain oriented silicon M4 steel lamination insulated and
oxide layer and outside of the core shall be protected against corrosion by epoxy resin
finish. Class 'F' insulation level shall be maintained. OFF load tap
changing facility shall be incorporated so as to achieve tap positions of +5% to -10% in step of 2.5%. four channel Temperature Scanner with 4 nos Sensors, annunciator
and trip mechanism shall be provided. The Transformer shall confirm to latest IS and ECBC standards. The maximum allowable loss limited to
values designated by ECBC Norms . All inter connection from HT Side to
transformer and to LT Side shall be given using electrolytic copper bus bar insulated
with heat shrink sleeves and tinned at the point of contacts. All internal earth
connections are to be given as per standards. Necessary protection shall be made for
giving cable connections on the HT side as well as LT side. Phase barriers and
shrouding as per rules has to be given.
The enclosure shall be fabricated from 2.00mm CRCA sheet, complying with of IP 54
standards and shall be powder coated over a coat of Zinc chromate primer after seven
tank processing and phosphatizing. The USS shall be installed as per the directions at
site. | 1 | each | 12,40,000 ₹12,40,000 | 14,30,000 ₹14,30,000 | 12,04,800 ₹12,04,800 Lowest |
| 1.00 | OD205713/2024-2025:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. | 5 | metre | 2,000 ₹10,000 Lowest | 2,400 ₹12,000 | 2,105 ₹10,525 |
| 1.00 | OD209549/2024-2025:Supply & laying of one number PVC insulated and PVC sheathed armoured
aluminium power cable of 11 KV grade of the following sizes in ground including
excavation of trench of size 35 x 100 cm, refilling the trench etc. as required 3 core
300 sqm stranded compact circular aluminum conductor, conductors screened with
extruded semi conducting compound XLPE insulated, insulation screened with
extruded semi conducting compound in combination with copper tape (0.3KA for I
sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and
overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest
amendments. -- | 10 | 1 metre | 2,100 ₹21,000 | 2,650 ₹26,500 | 2,096 ₹20,960 Lowest |
| 1.00 | OD205743/2024-2025:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminum power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. -- | 10 | metre | 2,000 ₹20,000 Lowest | 2,650 ₹26,500 | 2,207 ₹22,070 |
| 1.00 | 10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm | 1 | each | 11,000 ₹11,000 | 10,000 ₹10,000 Lowest | 18,000 ₹18,000 |
| 1.01 | 10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete
with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor
cable of 11 KV grade as required :300 sq. mm | 1 | each | 13,500 ₹13,500 Lowest | 18,000 ₹18,000 | 25,200 ₹25,200 |
| 1.01 | OD207208/2024-2025:Supply and providing cable trays or frame work of all sizes with angle iron/flat iron suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cable/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required | 300 | kg | 165 ₹49,500 | 160 ₹48,000 Lowest | 160 ₹48,000 Lowest |
| 1.01 | OD203748/2024-2025:Supply and fixing of 630 A, Enclosure type ATS unit with 4P motorized changeover with ATC controller unit and wire way kit or equivalent including auto start operation for existing DG set, all accessories including connections. | 1 | each | 1,45,000 ₹1,45,000 Lowest | 1,60,000 ₹1,60,000 | 1,50,200 ₹1,50,200 |
| 1.01 | 90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm | 36 | metre | 1,800 ₹64,800 Lowest | 2,100 ₹75,600 | 1,800 ₹64,800 Lowest |
Tender Value
₹31.1 L
EMD Value
₹50,000
Closing Date
16 Mar 2026, 4:00 pmClosed
Executive Engineer
Office of the Executive Engineer (electrical), PWD Electrical Division, Civil station, Alappuzha-688001
DEPOSIT-Ettumanoor ITI-Conversion to HT connection at Govt. ITI, Ettumanoor, Kottayam-HT-Electrical-Work
2026_PWD_844653_1
PWD/BLDG/TR/22054/2024_26_1_1
Open Tender
Electrical Works
Item Rate
180 days
Ettumanoor
Please refer tender documents
13 documents required · 13 mandatory
₹2,760
₹50,000
3 Jun 2026
6 Mar 2026
18 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Conversion to HT connection at Govt.ITI,Ettumanoor | |||||
| 1.001 | OD203944/2024-2025:Supply, conveyance, installation, testing and commissioning of 315 KVA, 11KV/433V Indoor
type unitized sub station of IP class 54, with cast resin Transformer with 11KV VCB mechanically ON/OFF
on H.T.side, and TOD Meter,Metering CT and PT ,with Top/bottom entry cable box .The LT
Portion Shall include 1No 630A 4 pole 50KA isolation duty type MCCB with microprocessor based release with overload setting of 50-100% with inbuilt earth fault relay suitable size Neutral CT
with MC12 Relay on L.T. side. The HT portion consists of 1No 11KV, 630A, 350MVA VCB with 2 o/c relay with high set element one E/F relay with DC trip with interlock with main switch and mechanical ON/OFF, shunt trip coil for the remote operation. TOD metering facilities consists of 3Nos....../5A (or suggested by KSEB) 15VA, 0.2class accuracy cast resin CTs, 1No 3 phase 3 Limb 11KV/110V, 10VA, 0.2 class accuracy cast resin PTs. with protective fuses. 1No TOD meter 1No TOD meter test terminal block,(TOD meter and CTs, PTs unit compartment shall be so fabricated. So as to enable the KSEB authorities to seal it) and including arranging testing and installation of the same with KSEB testing Division. Transformer Portion consists of 315 K.V.A , 11 K.V/433V,
50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core
shall be made of high grade grain oriented silicon M4 steel lamination insulated and
oxide layer and outside of the core shall be protected against corrosion by epoxy resin
finish. Class 'F' insulation level shall be maintained. OFF load tap
changing facility shall be incorporated so as to achieve tap positions of +5% to -10% in step of 2.5%. four channel Temperature Scanner with 4 nos Sensors, annunciator
and trip mechanism shall be provided. The Transformer shall confirm to latest IS and ECBC standards. The maximum allowable loss limited to
values designated by ECBC Norms . All inter connection from HT Side to
transformer and to LT Side shall be given using electrolytic copper bus bar insulated
with heat shrink sleeves and tinned at the point of contacts. All internal earth
connections are to be given as per standards. Necessary protection shall be made for
giving cable connections on the HT side as well as LT side. Phase barriers and
shrouding as per rules has to be given.
The enclosure shall be fabricated from 2.00mm CRCA sheet, complying with of IP 54
standards and shall be powder coated over a coat of Zinc chromate primer after seven
tank processing and phosphatizing. The USS shall be installed as per the directions at
site. | - | each | - | - |
| 1.002 | OD205713/2024-2025:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. | - | metre | - | - |
| 1.003 | OD209549/2024-2025:Supply & laying of one number PVC insulated and PVC sheathed armoured
aluminium power cable of 11 KV grade of the following sizes in ground including
excavation of trench of size 35 x 100 cm, refilling the trench etc. as required 3 core
300 sqm stranded compact circular aluminum conductor, conductors screened with
extruded semi conducting compound XLPE insulated, insulation screened with
extruded semi conducting compound in combination with copper tape (0.3KA for I
sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and
overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest
amendments. -- | - | 1 metre | - | - |
| 1.004 | OD205743/2024-2025:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminum power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. -- | - | metre | - | - |
| 1.005 | 10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm | - | each | - | - |
| 1.006 | 10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete
with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor
cable of 11 KV grade as required :300 sq. mm | - | each | - | - |
| 1.007 | OD207208/2024-2025:Supply and providing cable trays or frame work of all sizes with angle iron/flat iron suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cable/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required | - | kg | - | - |
| 1.008 | OD203748/2024-2025:Supply and fixing of 630 A, Enclosure type ATS unit with 4P motorized changeover with ATC controller unit and wire way kit or equivalent including auto start operation for existing DG set, all accessories including connections. | - | each | - | - |
| 1.009 | 90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm | - | metre | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1426197.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1426197.xls
BOQ • 0.35 MB
MOMEttumanoorITI.pdf
Other Document • 0.22 MB
SpecificconditionsElectrification.pdf
Additional Documents • 0.52 MB
viewsbd.pdf
Tender Documents • 2.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .