Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹31.6 L+₹1.6 L (5.36%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹33.5 L+₹3.5 L (11.8%)Rejected-Finance C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹33.8 L+₹3.8 L (12.5%)Rejected-Finance 113 SURESH SHARMA NAGAR NEAR S S V ENTER COLLEGE BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹34.6 L+₹4.6 L (15.2%)Rejected-Finance | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹48.9 L
EMD Value
₹97,800
Closing Date
28 Nov 2023, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
SPECIAL REPAIR TO ROOF TREATMENT OF BLDG NO. 10/1 TO 9 IN 621 JADC, PROVN OF SANITARY BLOCK NEAR BLDG NO. T-93(B WING) OF 346 FD REGT, TOILET BLOCK AT MDC, SECURITY GRILL CHANNEL GATE AT MH AND 03 NOS 1.5 TON ACs FOR OF JLA UNDER GE (WEST) BAREILLY
2023_MES_625980_1
8161/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹97,800
Yes
8 Dec 2023
31 Oct 2023
30 Nov 2023
31 Oct 2023
28 Nov 2023
16 Nov 2023
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Dismantling of water tank exc. 500 Litre but not exc. 1000 Litre capacity complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 with and including demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair without using extra cement with and including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and fair without using extra cement with and including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
Supply only liquid water proofing compound complete all as specified.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair without using extra cement with and including taking down cement or cement lime plaster from ceiling including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of old decorated plastered surfaces of walls and applying two coats of distemper oil emulsion by washing, rubbing down and stoping of old distempered surface complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparing old decorated wall surfaces and applying one coat of cement base paint complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M & L for 25 mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in floor or plinth protection, finished surface even and smooth without using extra cement with and including all necessary form work and forming joints 12 mm wide to the full depth of concrete at every 3 metres and every change of direction duly filled with bitumen filler 1:3 by weight complete all as specified and directed.
S & F of 500 Litre capacity tripple layered white coloured rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed concealed in walls and ceilings or laid under floors with and including taking up or down old steel water tubing and connection complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed concealed in walls and ceilings or laid under floors with and including taking up or down old steel water tubing and connection complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls or laid in floors with and including demolition and breaking up existing drain pipes (salt glazed stoneware, AC or reinforced concrete) complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
M & L for 25 mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) laid over roof slab, finished even and smooth without using extra cement over and including brushing neat cement slurry at the rate of 3 Kg per Sqm complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 over roof slab or parapet walls including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate with using Dr fixit pidilite LW(+) , of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 85/25 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.30 Kg/Sqm (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of brick / stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with two coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
S & F in repairs 20 mm dia and 1.0 mm wall thickness fancy type stainless steel drapery rod with decorative design matching brackets of approved quality, knobs (lattu) or end bracket as required including all necessary fittings, fixed with 80 mm long SS screws with 75 mm long rawl plug / wooden gitty of appropriate size for each end and intermediate support complete all as specified and directed.
Taking down existing solar water heater assembly of 500 Litres capacity 02 Nos., hot and cold water supply GI pipe line System (in/out) and dismentling of monkey cage of any size installed at bldg No. 10/3, dismantling of existing electric connection from LT pole & panel, re-instalation of solar water heating system of capacity 500 Litres 02 Nos. in existing connection including making the same serviceable after checking and replacement of unserviceable parts as required at site for making the same functional with and including necessary spare parts, instalation of hot water supply pipe, re-conecting of electric connection from LT pole / panel and refixing of monkey cage with and including necessary welding, nut-bolt, washers etc. complete all as specified and directed.
S & F of 20 mm bore ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
M & L for providing 40 mm thick pre-cast cement concrete louvers or RCC Jali made out of cement concrete 1:2:4 type B-0, using 12.5 mm graded stone aggregate and set in cement mortar 1:4 including all mouldings etc. complete all as specified and directed.
Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, cable trench etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for Use and waste of formwork to sides of flat surfaces of concrete in columns work in fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge
M & L for Use and waste of formwork to sides and soffits of floor or roof beams, Plinth beam, haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by the Engineer-in-Charge.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as in road / path, hard standing etc. laid in alernate bays with and including all necessary form work to divide the area in panels not exc. 9 Sqm each and providing 10 mm thick joints through out the thickness of road / path duly filled with mastic filling of one part of 85 / 25 hot bitumen and three part of coarse sand (By weight) complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for glazed ceramic coloured tiles 350 mm X 250 mm X 7 mm thick or 450 mm X 350 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions over and including applying evenly a coat of blown type bitumen @ 1.50 Kg per Sqm including cleaning of surface and binding with clean dry sand @ 0.05 cum per Sqm complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND WILL BE MEASURED AND PAID SEPARATELY.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
BLANK
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of exterior emulsion paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection, finished surface even and smooth without using extra cement with and including all necessary form work and providing 75 mm wide and 3 mm thick glass dividing strip inserted in position at every one meter and change of direction with and including demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
S & F of factory made steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F of galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S & F of FRP door frame of size 100 mm X 50 mm made of 3 mm thick coloured pre-laminated FRP sheet with UV grade polyester Resin complete all as specified and directed. MAKE- Surya Fibre glass industry, Everest composite Pvt Ltd, Pyramid FRP door, Pune.
S & F of 30 mm thick FRP door shutter with UV Grade polyester Resin made of minimum 3 mm thick coloured pre-laminated FRP sheet fixed on both sided complete all as specified and directed. MAKE- Surya Fibre glass industry, Everest composite Pvt Ltd, Pyramid FRP door, Pune.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair without using extra cement complete all as specified and directed.
S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. confirming to Fe-410-W (Grade E-250) Quality 'B', drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening complete all as specified and directed.
S&F 100 mm size stainless steel butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and directed.
S&F 150 mm long,aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size aluminium handles,cast type,anodised complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F of 15 mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘HOT’ or ‘COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F of PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc and 32 mm dia PVC flush pipe of suitable length and making all connection and making good disturbed surface complete all as specified and directed.
S & F of 15 mm bore fancy type, chromium plated stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F of 20 mm dia brass chromium plated tubular towel rail ‘D’ type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S & F of vitreous china wash down water closet pan (Pedestal pattern) white including fixing bolts and making connection to flushing cistern, flush pipe etc. with and including plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices complete all as specified and directed.
S & F of stainless steel chromium plated peg set of 6 Nos. of hooks complete all as specified and directed.
S & F of soap dish of standard size, brass chromium plated fixed to wall complete all as specified and directed.
S & F of 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F of 125 mm dia grating doom of stainless steel chromium plated fixed with white cement complete all as specified and directed.
M&L for providing a layer of APP based polymeric membrane, 3mm thick (minimum), weighing 3.5 Kg/Sqm reinforced with polyester non woven fabric shall be applied over one coat of cold bituminous primer @ 0.25 ltr per Sqm and applying one coat of aluminum paint over the APP medified membrane @ 0.11 Kg/Sqm complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal provided with oval access door, fixed with solvent cement complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
BLANK
S&F of chromium plated brass shower rose of superior quality long body with or without swivel joints of 125 mm size suitable for fixing with 15 mm bore pipe complete all as specified and directed.
S&F of 15 mm dia chromium plated angle valve of superior quality complete all as specified and directed.
S&F of brass chromium plated wall mixer (three-in-one) suitable for telephonic and overhead shower both with long bend pipe complete all as specified and directed.
S & F of vitreous china wash basin white, flat back, size 550 X 400 mm excluding taps, waste, chain and plug but including brackets, cutting for and pinning in as required complete all as specified and directed.
S & F in repair vitreous china urinals, bowl type (flat back or corner wall type) 465 X 355 X 265 mm white (minimum) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, grating and union for discharge pipe but excluding flushing cistern, flush pipe etc. complete all as specified and directed.
M & L for coloured chequered cement concrete tiles 300 mm X 300 mm X 25 mm thick, set, jointed and pointed in neat cement slurry as in floors with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dence soil for laying of LT UG cables/base for Pole etc complete all as specified and directed.
M&L for sand cushioning laid in trenches for laying of LT UG cables complete all as specified and directed.
M&L bricks common burnt clay building bricks, sub-class ‘B’ for LT UG cable protection complete all as specified and directed.
S&F GI tubes light grade of dia 40 mm with all fitting and fixed complete for protection of LT UG cables laid to walls or in floors or along with poles etc complete all asspd and directed.
Excavation over areas not exc. 1.50 m deep and getting out in soft / loose soil complete all as specified and directed.
M & L for vitrified ceramic light shade tiles 10 mm thick (Square or Rectangular) polished, area of each tile exc. 0.42 but not exc. 1.00 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying tiles finished even and rough complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
BLANK
M & L for cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M & L for 150 mm bore salt glazed stoneware drain pipes grade ‘A’ laid in trenches and jointed in cement sand mortar 1:1 with spun yarn complete all as specified and directed.
S&F vitreous china, coloured, wash hand basin, flat back size 550x400mm 'including MS brackets including cutting for and pinning in, including waste pipe and CP waist coupling etc. complete all as specified & directed.
S & F of collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes and covered with 3 mm thick plastic laminated sheet cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and directed for the following:-
(a) One light / fan/ exhaust fan point controlled by one switch.
(b) One 5 Pin 5 Amp Socket Outlet point on an independent board
(c) One 5 Pin 5 Amp Socket Outlet point on same board
All as per Srl item No. 107.00 here in before but for one 15 Amp 6 Pin switch socket out let independent with 4 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 4.0 sq mm FRLS PVC copper conductor single core used as earth continuity conductor complete all as specified and directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F socket out let 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
S&Fswitch piano type 15 Amp flush type 240 Volt complete all as specified and directed.
S&Fsocket out let 6 Pin 2 in 1, 5/15 Amp flush type 240 Volt complete all as specified and directed.
S&F switch piano flush type 15 Amp single pole two way complete all as specified and directed.
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed.
M & L of lamp holder, PVC / Poly carbonate, insulated body modular type with back plate batten/angle type for batten fittings complete all as specified and & directed
S&F LED light fitting of 1 x 10 watt T-5 lamp type with electronic ballast of suitable capacity, clear acrylic cover including mounting on wall complete all as specified and directed.
Supply and fixing surface mounting LED light fitting aluminium extruded T-5 batten , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed.
Supply and Fix LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete with all fixing arrangement incl making holes etc all as spd and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed.
S&F MCB SPN 40 Amp 240 volt complete all as specified and directed by the Engr-in-Charge.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed by the Engr-in-Charge.
Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete including taking down old unsv all as specified and directed.
Supply and fixing LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion esistant including thermal management in multiple optics complete with IP 65/66 protection complete incl complete with M&L GI pipe mounting bracket of size 32 mm dia,medium grade and 1.20 m long fixed to wall with and including nut, bolts and GI clamps made out of MS FI of size 50 x 6 mm as required including painting with two coats of synthetic enamel paint over a coat of red oxide primer and making connection with three core 23/0.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced all as specified
M&L for sub main wiring with two single core 4.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 4.0 sqmm (FRLS), one run of 4.0 sqmm (FRLS) copper conductor and one run of PVC conduit shall be measured as one unit length)
M&L for sub main wiring with two single core 6.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 6.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 6.0 sqmm (FRLS), one run of 6.0 sqmm (FRLS) copper conductor and one run of PVC conduit shall be measured as one unit length)
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 4 core. complete all as specified and directed.
Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with cooling and heating function and digital inverter twin rotary of capacity 1.5 TR single phase complete all as specified and directed.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 4 core. complete all as specified and directed.
S & F voltage stabaliser for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130 volt to 250 volt with output voltage stabalizer at 230 Volt accuracy of +/- 2.5 % and capacity 5 KVA complete all as specified and directed.
S & F AC Modular Box with Plug Top and MCB 32 Amps including modular box for mounting etc, of capacity 20 Amps universal complete all as specified and directed.
NOTE- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
M/S YASHCON CONSTRUCTIONS
hardeep singh enterprises
M/S Harshri Nath Enterprises
REHAN CONSTRUCTIONS
R K CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .