Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC MATTATHIL KAROTE H VADACODE P O KANGARAPADY | ₹6.5 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹6.8 LRejected-AOC | ₹6.8 L | L2 | Rejected-AOC Second Lowest bidder |
| 3 | L3₹8.2 LRejected-AOC NEDUMPURAM HOUSE KANNIMANGALAM NEAR GURUDEVAN L P SCHOOL AYYAMPUZHA NADUVATTOM P O | AYYAMPUZHA | KERALA | ₹8.2 L | L3 | Rejected-AOC Highest bidder |
Updated dates
Tender Value
₹6.8 L
EMD Value
₹17,100
Closing Date
28 Mar 2026, 5:00 pmClosed
Executive Engineer, Project Management Unit, KSEBL
Office of the Executive Engineer, Project Management Unit, KSEBLtd Perumbavoor.
REROUTING CONSTR. OF OH LINE FROM NAYIRUPEEDIKA JN. TO CHEMBARATHUKUNNU MOSQU UNDER ELECTRICAL SECTION VAZHAKULAM
2026_KSEB_847827_1
37/ EE / PMU-PBVR / 2025-26/PBVR/ 12.03.2026
Open Tender
Electrical Works
60 days
vazhakulam
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,652
₹17,100
7 May 2026
17 Mar 2026
31 Mar 2026
17 Mar 2026
28 Mar 2026
17 Mar 2026
Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges.
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling (without damage) one Channel cross arm from existing DP structure and bringing back to section store.
Dismantling (without damage) one V cross arm/Channel cross arm from existing Pole and bringing back to section store.
Dismantling (without damage) one km 11kV line (three conductors) including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials.
Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Fitting and erecting one HT Double Pole Structure using A type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil.
Dismantling (without damage) one LT PSC/RCC Strut pole including removal of clamps and stacking.
Dismantling one damaged HT TW/RSJ/Rail Strut pole including removal of clamps and stacking.
Transferring LT three phase 4/5 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete.
Transferring LT single phase 2/3 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete.
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
Stringing of one km 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalant (3 conductors) after fitting insulators, binding conductors to pin insulators using suitable tie and anchoring with wedge type anchoring clamps including cutting and removing tree branches wherever necessary excluding cut point works.
Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point.
Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole.
Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
Disconnecting and lowering down the three phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials.
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance of materials.
Fitting and providing one Strut using HT PSC pole including digging and back filling pit in ordinary soil.
Providing Strut using LT PSC pole including digging and back filling pit in ordinary soil.
Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides.
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling.
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at standard distance (1.5m) away from the pole/structure in ordinary soil & backfilling the pit with 15cm alternate layer of charcoal, salt and sand up to 90cm from the bottom. including the cost of 20kg salt, 25kg charcoal, excluding supply of earth pipe.
Custom Labour for transporting single pole by hired vehicle to a distance up to 5 km excluding loading & unloading charges.
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Dismantling one damaged AB switch from existing structure and bringing back to section store.
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
Erection of Anchor clamp / dead end clamp for 11kV ABC of any size
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm and connecting to existing MVT or other terminals,using the cable end termination kit supplied departmentally including charges for cable jointer etc. complete as per the direction of the departmental officers.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1432925.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tendernayirpeedika.pdf
Tender Documents • 1.02 MB
BOQ_1432925.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid