CHIEF OFFICER NAGAR PALIKA BODELI
PROVIDING AND SUPPLYING OF VARIOUS ELECTRIFICATION RELATED ITEMS YEAR 2026 27 BODELI MUNICIPALITY DIST - CHHOTAUDEPUR UNDER THE GRANT OF NAGAR PALIKA SELF FUND
270432
509/2026
Open
Electrical Works
Chhota Udaipur
13 documents required · 13 mandatory
₹1,062
Yes
The Chief Officer, Bodeli nagar palika, Bodeli.
₹25,000
Yes
29 Jan 2026
29 Jan 2026
29 Jan 2026
6 Feb 2026
29 Jan 2026
Repairing of existing indoor LED light fixture(tube light/panel light/spot light/strip light/decorative wall lights etc as per sample )by suitable driver 2 kv according to LED PCB as per requirement of following rating wattage capacity . (g)50-80 watt capacity
Repairing of existing indoor LED light fixture(tube light/panel light/spot light/strip light/decorative wall lights etc as per sample )by suitable driver 2 kv according to LED PCB as per requirement of following rating wattage capacity . (h)90-100 watt capacity
Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS. (a) 32 A - Cat.II
Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS (a) 32 A - Cat.II
Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS (b) 63 A. Cat.II
Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS (b) 63 A. Cat.III
Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS (c) 100 A/125 A Cat.II
Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS (c) 100 A/125 A Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity -(A) 6 to 32 Amp. - Cat.I
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. Cat.II
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity - (B) 40 Amp. - Cat.I
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (B) 40 Amp. Cat.II
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (B) 40 Amp. Cat.III
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (a) 2 core 2.5 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (b) 2 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. ( c ) 2 core 6 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (d) 2 core 10 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (a) 3 core 2.5 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (b) 3 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (c)3 core 6 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (d)3 core 10 Sq. Mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (a)4 core 2.5 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (b)4 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (c)4 core 6 Sq. mm
Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (d)4 core 10 Sq. Mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (A) 3 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (B) 3 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (C) 3 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (D) 3 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (E) 3 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (F) 3 core 25 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (G) 3 core 35 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (H) 3 core 50 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (a) 4 core 4 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(b) 4 core 6 Sq. Mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (c) 4 core 10 Sq. mm
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (A)50 mm outer dia
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (B) 63mm outer dia
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (C))90 mm outer dia
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (D)120 mm outer dia.
Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with Brush Less Direct Current BLDC permanent ferrite magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision 22 gauge copper winding, Power factor not 0.9, Service Value CMM W minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v (tolerance as per IS : 374-2019, THD 10 remote or electronic regulator unit for Speed Control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C Max, suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required.Make shall be approved by Engineer in Charge] A 900 mm sweep A90 0mmsweep 36
Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with Brush Less Direct Current BLDC permanent ferrite magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, 22 gauge copper winding, Power factor not 0.9 Service Value CMM W minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v tolerance as per IS : 374-2019 THD 10, remote or electronic regulator unit for Speed Control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C Max. suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required. Make shall be approved by Engineer in Charge] A900 mm sweep A 1200 mm Sweep 48
Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with Brush Less Direct Current BLDC permanent ferrite magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, 22 gauge copper winding, Power factor not 0.9, Service Value CMMW minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v tolerance as per IS : 374 2019 THD 10, remote or electronic regulator unit for Speed Control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C Max. suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required. Make shall be approved by Engineer in Charge] A900 mm sweep B 1400 mm Sweep 56
Item Description
Supplying Table fan approved make A.C. 23OV, 50 c/s. 40 cm. sweep oscillating complete with 3 mtrs. of 3core round flexible wire and 3 pin plug top. [ Make shall be approved by Engineer in Charge]
Supplying and erecting approved make Pedestal Circulatory fan A.C. 230 V. 50 Cy/s. 600 mm sweep and adjustable height complete with guard, & standard lead flexible wires and plug top. Cat.I
Supplying and erecting approved make Pedestal Circulatory fan A.C. 230 V. 50 Cy/s. 600 mm sweep and adjustable height complete with guard, & standard lead flexible wires and plug top. Cat.II
Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II) 1980. Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube should be ISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat of Aluminium /approved paint to be erected on / in existing Foundation. The length of poles are as below. (A) 7.5 mtr. Long Swaged Steel tubular pole ((i) pole as per IS code 410-SP-4 with 300 X 300 X 4 mm base plate. (Approximate Pole weight 67 Kg) For burial erection
Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II) 1980. Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube should be ISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat of Aluminium /approved paint to be erected on / in existing Foundation. The length of poles are as below. (A) 7.5 mtr. Long Swaged Steel tubular pole ( (ii) Add Extra for M.S. Base plate 300 X 300 X 16 mm for pole, Suitable for mounting on surface of foundation with foundation bolts, with required stiffeners welded with pole.)
Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II) 1980. Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube should be ISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat of Aluminium /approved paint to be erected on / in existing Foundation. The length of poles are as below. (A) 7.5 mtr. Long Swaged Steel tubular pole ( (iii) Add Extra for PU base primer and PU Paint on pole.)
Providing Aluminium arm bracket of having 2 sets of suitable SS304 hardware for fixing the brackets & spread of 2 Mtr (Suitable for 89 to 114 mm pole top dia) (a) Single arm bracket
Providing Aluminium arm bracket of having 2 sets of suitable SS304 hardware for fixing the brackets & spread of 2 Mtr (Suitable for 89 to 114 mm pole top dia) (b) Double arm bracket
Providing Aluminium arm bracket of having 2 sets of suitable SS304 hardware for fixing the brackets & spread of 2 Mtr (Suitable for 89 to 114 mm pole top dia) ( c) Triple arm bracket
Providing 1 2 4 cement concrete foundation 70 PCC from bottom including excavation for the pole of size 60 60 150 cm Deep in below ground level with plinth of 45 cm 45 cm or 45 cm dia 45 cm high upper ground level with necessary curing and finishing in approved manner. for 9 10 mtr pole
Supplying and erecting Fabricating terminal box for street light pole made from 16 SWG M.S. sheet having following size complete with fixing arrangement for terminal board, with necessary hole for wire entry and exit from the box. The box shall be provided with cover and hinges on one side and bolting at other end The box shall be fixed by clamps fabricated from 25mm 6mm flat.The box shall be painted with one coat of red oxide and two coats of paint having following box size. 330 mm 260 mm 140 mm depth
Supplying erecting dual channel amplifier ,power handling capacity of 180 watt ,four micro phone inputs with independent level control ,built in FM tuner,with preset memories,USB drive SD card for MP3 playback 100v telephone input with priority and VOX frequency response-80 Hz to 18k Hz Philips distortion less than 1 rated power up to 50 units
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD SECTION-5 TECHNICAL SPECIFICATION.pdf
SBD SECTION-6 FORM OF BID.pdf
SBD SECTION-7 BILL OF QUANTITIES.pdf
SBD SECTION-9 DRAWING.pdf
SBD SECTION-10 DOCUMENTS FURNISHED BY BIDDER.pdf
BOQ.pdf
Notes.pdf
Required Attachment Form as Per Bid Evaluation Criteria.pdf
Document
OTHER IMPORTANT-1.pdf
OTHER IMPORTANT-2.pdf
OTHER IMPORTANT-3.pdf
SBD SECTION-1 TO 4.pdf
Download all tender documents and submit your bid