Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.2 LAccepted-AOC | ₹95.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹95.2 L+₹572.21 (<0.01%)Rejected-AOC | ₹95.2 L+₹572.21 (<0.01%) | L2 | Rejected-AOC L2 |
| 3 | L3₹95.2 L+₹1,196 (0.01%)Rejected-AOC | ₹95.2 L+₹1,196 (0.01%) | L3 | Rejected-AOC L3 |
Tender Value
₹95.2 L
EMD Value
₹1.9 L
Closing Date
28 Mar 2022, 3:00 pmClosed
The S.E, PWD, Kokrajhar, Bldg, Circle
O/o the S.E, PWD, Kokrajhar, Bldg, Circle, Kokrajhar
Construction of security barrack, kitchen, sanitary latrine, RCC staging, construction of brick drain and construction of CC block approach road at Gossaigaon SDO (C) office and residential complex, Gossaigaon, Kokrajhar. Package No.505_1
2022_BoTC_24646_1
No. TECH- 05/SE(B)/E-Tender/2021-22/24
Open Tender
Civil Works - Building
Item Rate
180 days
Gossaigaon
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,900
The Principal Secretary, BTC, Kokrajhar
₹1.9 L
Yes
7 Apr 2022
10 Mar 2022
28 Mar 2022
10 Mar 2022
28 Mar 2022
10 Mar 2022
10 Mar 2022 - 28 Mar 2022
Amount
(A) Construction of Security barrack, 2 Nos: Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steeel/Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steeel/Jindal steel/Shyam steel/RINL (c) ISI approved Mild Steel reinforcement bar (M.S.Bar)
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face. (i) Using 12mm thick ply.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing and laying controlled cement concrete of grade M20 with 20mm down graded stone aggregate including dewatering if necessary and curing complete etc. but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser. b) M20 grade concrete or prop.1:1.5:3
Providing and laying controlled cement concrete of grade M20 with 20mm down graded stone aggregate including dewatering if necessary and curing complete etc. but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture, plasticiser. b) M20 grade concrete or prop.1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary. (b) In proportion 1:5
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:4
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary,carriage,watering,raming etc.complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With river sand or Silt (predominently non plastic) by truck carriage including loading and unloading.
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrough, framed and fixed in position in contact with C.C or brick masonary wall including supplying fitting and fixing with M.S hold fast (40mm x 3mm x 250mm) as per design embedded in cement concrete block in proporation 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonary as directed and specified. a) With sal wood.
Providing barge board of size 200mm x 20mm with 1st class local Hollock/Bonsum timber including fitting and fixing with necessary wood screws etc complete.
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately) (b) 50mm thick
Providing galvd iron riding of TATA shaktee/SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. B. 0.50mm thick. (ii) 230mm lapping
Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar.............directions of engineer-in-charge. (B) Designer Ceilings of Everest make of equivalent as directed by the department. (ii) Using 6 mm thick FC Board
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Providing fitting and fixing 1st class local wood (Gamari) battend, ledged and braced door and window shutter including oxidized iron butt hinges (100mm x 58mm x 90mm) 6 nos with necessary screws. (a) Using Bonsum/Hollock wood (ii) 20mm thick
Providing fitting and fixing fully galzed clerestory window and fan light including fitting and fixing 2 M.S pivot hings. (75mm x 20mm x 3mm) eye hook and nylon chord complete (glass panesd shall be measured ad paid separately) (B) With Gamari wood. (ii) 30mm thick.
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm diwn) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : 1 coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of bond @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
Providing 13mm mesh hexagonal wire made of one I.S. designation (1mm dia) wire above post plate in eaves with 1st class Hollock/Bonsum/Sundi timber frame to fit exactly with the corrugation of roofing sheet including kiricide oiling two coats to timber works including as directed.
Providing and fixing clear sheet glass beded in putty and fixed with/without wooden leading including necessary cutting and glass to be required sizes (payment for wooden beads shall be made separately) (i) Area of glass panes exceeding 0.15 m2 but not ecessing 0.52 m2. © 3.00mm thick
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using M.S.circular hollow section conforming to relevent I.S. code, as per approved design and dressing including providing M.S. cleats, plates bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paintscomplete including fitting necessary clear etc. for fixing joists as per design and drawings as directed. (b) Using other ISI marked approved circular hollow section.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter sand papering and knottine. (b) With ready mixed paint, wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter papering stopping. (i) Surface over 100mm in width or girth. b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
f) Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose or softened paint.
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with concrete sunk holes for crews including necessary aluminium screws etc.complete. (Anodized to bright natural matt & stain finished) a) Sliding door bolts (i) 300mm x 16mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with concrete sunk holes for crews including necessary aluminium screws etc.complete. (Anodized to bright natural matt & stain finished) b) Tower door bolts (ii) 250mm x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with concrete sunk holes for crews including necessary aluminium screws etc.complete. (Anodized to bright natural matt & stain finished) (iii) 200mm x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with concrete sunk holes for crews including necessary aluminium screws etc.complete. (Anodized to bright natural matt & stain finished) (c) Door Handle (iii) 150mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with concrete sunk holes for crews including necessary aluminium screws etc.complete. (Anodized to bright natural matt & stain finished) (D) Gate and shutter hooks and eyes. (ii) 150mm
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Plain cement concrete aprone in prop 1:4:8 with 20mm down graded coarse agg. Over soiling including neat cement finish uising cement slurry 2.75kg of cement per sq.m of floor (soling to be measured separately) (b) 50mm thick.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earthwork in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
(B) Construction of Kitchen, 2 Nos: Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary,carriage,watering,raming etc.complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With river sand or Silt (predominently non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :4 sand : 8 coarse aggregate by volume.
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing & laying plain/reinforcement cement concrete work in prop.1:2:4 including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixture machine (a) In Sub-Structure up to plinth level (A) Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N. Without using admixture plasticizer. a. M-15 grade concrete or prop 1:2:4
Providing & laying plain/reinforcement cement concrete work in prop.1:2:4 including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixture machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N. Without using admixture plasticizer. b. M-15 grade concrete or prop 1:2:4
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face. (i) Using 12mm thick ply.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick flat soiling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary. (b) In proportion 1:5
112mm thick brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar..........paid separately) b) In proporation 1:5
65mm thick cement concrete floor consisting of 53mm under layer of cement concrete 1:3:6 (1 cement 3 coarse sand 6 coarse agg. of 25mm and down) and 12mm thick wearing coarse of cement sand plastering in prop.1:2 laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (c) In cement mortar 1:5
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side. (c) In cement mortar 1:6
Providing fitting and fixing hard board sheet ceiling with approved quality with necessary nails wood screws including 1st class local wood 50mm x 12mm (hollock/bonsum/sundi) beading including painting two coats to timber beads complete as directed (ceilling) joist to be measured and paid separately). (a) 4 mm thick.
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately) (b) 50mm thick
Providing corrugated galvd. Iron sheet TATA Shaktee/Sail including supplying fixing necessary galvd.screws/washer etc. complete as directed. (a) 0.45mm thick (ii) 150 mm lapping.
Providing wood work in frame of false sceilling partition etc. sawn wrought frame hoisted and fixed in position with spikes, nails M.S flat amgles/cleats with bolts and nuts complete including kiricide oiling two coats to unexposed surface of timber. / (1st class local wood)
Providing barge board of size 200mm x 20mm with 1st class local Hollock/Bonsum timber including fitting and fixing with necessary wood screws etc complete.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose or softened paint.
c) Applying one coat of distemper primer of approved brand and manufacture on wall surface after throughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth
(m) Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface top an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from morter droppimgs and other foreign matter and including preparing surface even and sand papered somooth. (ii) Top coat
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter sand papering and knottine. (b) With ready mixed paint, wood primer (pink)
Painting two coats (excluding priming coat) on new wood and new wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surface over 100mm width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel surface.............with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead" primer.
Painting two coats (excluding priming coat) on new..............including cleaning the surfaces of all dirt, dust and other foreign matterials. (i) Surface over 100mm width or girth. b) With Asian paints/Berger/ICI/J&N brand glossy enamel paint.
Supplying, fitting and fixing electroceleured iron fittings if approved make, reasonable smooth, free fro sharp edges and corners flaws and other defects and with counter sunk belows for wood screws including necessary screws etc. complete. (a) Sliding door bolts (i) 300mm x 16mm
Supplying, fitting and fixing electroceleured iron fittings if approved make, reasonable smooth, free fro sharp edges and corners flaws and other defects and with counter sunk belows for wood screws including necessary screws etc. complete. (b) Tower bolts (ii) 200mm x 10mm
Supplying, fitting and fixing electroceleured iron fittings if approved make, reasonable smooth, free fro sharp edges and corners flaws and other defects and with counter sunk belows for wood screws including necessary screws etc. complete. (c) Cast iron stove door Handles (iii) 150mm
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (upto 1st floor level) (b) Other ISI approved TMT reinforcement bar.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (upto 1st floor level) (c) ISI approved Mild Steel reinforcement bar (M.S. Bar)
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using M.S.circular hollow section conforming to relevent I.S. code, as per approved design and dressing including providing M.S. cleats, plates bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paintscomplete including fitting necessary clear etc. for fixing joists as per design and drawings as directed. (b) Using other ISI marked approved circular hollow section.
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
Providing, fitting and fixing steel windows/ door shutters with provision to be fitted MS angle including painting with red lead paint along with khili kabzaa made out of MS flat of 30mm x 4mm thick, minimum 3 nos for each door leaf and 2 nos for each window leaf.
(C) Construction of Sanitary latrine, 2 Nos. Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (c) ISI approved Mild Steel reinforcement bar (M.S.Bar)
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face. (i) Using 12mm thick ply.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (i) Using MIxture Machine. (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser.
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (i) Using MIxture Machine. (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (N) Without using admixture, plasticiser.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (b) In proporation 1:4
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary,carriage,watering,raming etc.complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With river sand or Silt (predominently non plastic) by truck carriage including loading and unloading.
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc.
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall. (b) In cement mortar in proporation 1:5
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using M.S.circular etc. (b) Using other ISI marked approved circular hollow section.
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as.............etc.
Providing fitting and fixing 24mm x 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkhath..........etc. b) 29mm thick
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering etc. A) On rough side b) In cement mortar 1:5
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop 1:3:6 etc.
Cement plaster skirting with cement in mortar in prop 1:3 (1 cement : 3 coarse sand) finished with a floating coat…etc. a. 15mm thick
(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface etc.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an……….etc.
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing.........etc. (c) 0.50mm thick
For Sanitary fittings L/s
(D) RCC Stagging with boring: Water supply with DTW Boring Labour for boring hole for inserting tube well through the difference soil/Rock media. Iv) 150mm dia.
Supplying fitting and fixing pipes/level ended for cosing conforming to relevent I.S. Code of practece including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole. Ii) PVC PIPE SUPREME/PRINCE/FUSION/SFMCBrand.
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice........ A) TATA/SAIL (Medium) soocket should be welded to the pipes. iv) 50mm dia
Supplying fitting and fixing GI filter 2.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iv) 50mm diameter
Flushing, clearing, washing and watering of the tube well
Supplying including installation of open well submersible type water supply motor pump set ..... 2) 1.5 HP Single phase
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank tank of Sintex/Polycon/Patton make over the stagging with manhole cover with. (iii) 1000 litre capacity
Supplying fitting and fixing approved UPVC pipes of different size with all necessary R brand or Similar approved PVC….. A. Exposed or in trenches (Supreme/Prince/SFMC brand. A) 50mm dia.
Supplying fitting and fixing approved UPVC pipes of different size with all necessary R brand or Similar approved PVC….. A. Exposed or in trenches (Supreme/Prince/SFMC brand. B) 40mm dia.
Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps including refiling (return filling) the quantity.............. (A) With out a depth upto 2.00 m below the existing G.L (a) In Ordinary Soil.
Providing soiling in foundation and under floor at all levels with stone/best quality picked jhama bricks......... (a) Brick flat soiling.
Plain cement concrete works with coarse agg. Of size 13 mm to 32 mm in foundation bed........... B) In prop.1:4:8
Supplying fitting and fixing in position reinforcement bars........ B) Other ISI approved TMT bars.
Providing form work of 12mm thick plywood board........... 3.2.1.1. Colums, pillars, posts & strut Square, Rectangular...........
Providing form work of 12mm thick plywood board........... 3.2.1.2. Sides and soffits of beams, beam haunching, cantilever......... A) Depth not exceeding 1.00m.......
Providing form work of 12mm thick plywood board........... 3.2.1.3 Flat surface.........
Providing & laying plain/reinforcement cement concrete work with coarse agg. 20 mm down.................. (i) Using Mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam... N. Without using admixture plasticizer. a. M-15 prop 1:2:4
Providing & laying plain/reinforcement cement concrete work with coarse agg. 20 mm down.................. (i) Using Mixture machine (a) In Super-Structure up to 1st floor level. ii) Column, pillar, post, structs........ N. Without using admixture plasticizer. a. M-15 prop 1:2:4
Providing barge board of size 200mm x 20mm with 1st class local Hollock/Bonsum timber including fitting and fixing with necessary wood screws etc complete.
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately) (a) 0.50mm thick
Providing galved Iron riding of TATA SHAKTEE/SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (A) 0.50mm thick (ii) 230mm lapping
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering........... A. On rough side (b) In Cement mortar 1:4
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Stel truss with M.S circular hollow section............
Add extra for extra height of roofing and RCC works...
(E) Construction of Campus brick drain: Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary. (b) In proportion 1:5
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Providing precast RCC slab over drain septic tank etc. in prop 1:2:4 reinforced with 10mm MS bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering curing etc. complete including fixig in position as directed. a) 100mm thick slab.
(F) Construction of CC Block and Approach Road: Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (b) stone soling.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering,shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Sides of the beams grade beams etc. at or below ground level.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Supplying and filling sand gravel in foundation trenches of column footings over slussy soil........... the bearing capacity of the soil as directed and specfiied including payment of forest royalty and sales tax and other duties and taxes as may be necessary.
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength..........such a plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between the blocks including construction of restrain wherever required complete as per drawing and technical specification clause 1504 of MORD.
Narayan Ch. Brahma
M/S. S.L. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .