Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | ₹1.4 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹1.6 Cr+₹21.0 L (15.2%)Rejected-Finance | ₹1.6 Cr+₹21.0 L (15.2%) | 2 | Rejected-Finance L2 |
| 3 | 3₹1.7 Cr+₹29.1 L (21.1%)Rejected-Finance | ₹1.7 Cr+₹29.1 L (21.1%) | 3 | Rejected-Finance L3 |
| 4 | 4₹1.7 Cr+₹30.4 L (22.0%)Rejected-Finance | ₹1.7 Cr+₹30.4 L (22.0%) | 4 | Rejected-Finance L4 |
| 5 | 5₹1.7 Cr+₹31.4 L (22.8%)Rejected-Finance | ₹1.7 Cr+₹31.4 L (22.8%) | 5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | sadeep kumar L8 | MNBN Enterprises L7 | ANIL KUMAR VASHISHT(GOVT, CONTRACTOR) L4 | HYDRAULIC ENGINEERING COMPANY L5 | Sushant Puri L1 | Samjeev Malhotra L6 | Rajat Attri L2 | puneet angra L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Installation of Submersible Pumping Machinery with allied accessories and with Automation Supply of submersible pumping set of Kirloskar/Crompton/KSB make conforming to BIS; 8034-1976 latest suitable for lifting clean water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- (2 Set of 20 HP each = 2x20 = 40 BHP) SITE CONDITIONS Location of Site About 17 Km from Ghumarwin The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt. =592.5 Humidity Weather generally remains humid during monsoon Season Nature of atmosphere As normally encountered in Shivalik Range Detail of quality of water Raw water Water free from sand or not Yes. Water corosive or not Yes. Turbidity (if any) Upto 5000 PPM NPSH available Positive suction. Any other information or requirement. | 40 | Per HP | 24,999 ₹9,99,960 | 30,000 ₹12,00,000 | 27,100 ₹10,84,000 | 22,800 ₹9,12,000 | 23,000 ₹9,20,000 | 24,988 ₹9,99,520 | 21,999 ₹8,79,960 Lowest | 22,250 ₹8,90,000 |
| 1.01OPERATION CONDITIONS Type of current AC three/single phase Operating frequency 50 HZ Rated voltage 400 (+/-) 10% volts System of earthing if any to be adopted Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. No. of working hours per day 20 hours. Speed of revolution in RPM To be quoted by tendere. Direction of rotation To be quoted by tenderer.The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service 35 Degree Centigrade | |||||||||||
| 1.02MOTOR Ref to BIS code BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments.Type of enclosure of motor SPDP (as per BIS 4691-1985 (Latest) Type of duty Continuous Mechanical out put in KW. Suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation Class- B. Max. permissible temprise of motor reqd, if different from given in B (viii) above. Particulars of test reqd. & wheire they are to be conducted As per terms & conditions. Particulars as to whether voltage limiting device will be employed ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor. Shunt capacitor is also proposed to be installed for improving the power factor at site.NOTE :- Star delta starter upto 37.5 KW. ATS between 37.5 KW to 50 KW & Stator rotor starter with slipring motor beyond 50 KW. Motor whether squirrel cage or slipring. Squirrel cage/slipring. Note :- Squirrel cage upto 65HP and slipring above 65 HP Details of shaft extension reqd Just sufficient to provide direct drive by flexible coupling to pump.Type of slip ring gear whether continously rated or for starting puposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required Continously rated for Squirrel cage/ slipring motor.Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current. Nature of laod & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No. of starts during a specified period To work the pump offered.Where possible fault capacity of the system to which the motor is connected. The motor should be able to withstand initial current of 2.5times the rated current for two minutes without suffering damages or permanent defomations | |||||||||||
| 1.03PUMP (IS 8034 -1974) read with BIS 9137-1978 both latest with Upto date ammendemnts Nos of pumps reqd. 2 Nos working pumps Spare parts required For two years normal maintenance as recommended by manufacturer Optional fittings reqd Air cock for exahausting air from each stage | |||||||||||
| 1.04PUMP OPERATING CONDITIONS Capacity 25.26 LPS Each Total head in Mtrs.29.60 Mtrs If total head is not known then follwing details be provided :-Static head 25.30 Mtrs Mininimum depth of water ---- mtrs. Variation in water level ---- mtrs. Ground level to max. water level ---- mtrs. Ground level to delivery point ---- mtrs. Presure in the suction tank -----Kg/cmΛ² Pressure in the delivery tank -----Kg/cmΛ² Length of Rising main 75 mts. Dia of R/main 250 mm. Drive arrangement- Direct through flexible coupling on a common base plate. Drive type Electric driven. NPSH reqd To be quoted by the tenderer.Limits of total head in which the pump is reqd. to operate (-) 25% to (+) 10% of total head. Suction/delivery size of pump. To be specified by the tenderer.Efficiency of pump at not less than 60% To be specified by the tenderer duty head (+) 10% head (-) 25% head. Material of construction To be specified by the tenderer. (Manufacturers certificate to be appended) | |||||||||||
| 1.05Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for Submersible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 1 No. pump of rating10 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Reputed make. 1 No | |||||||||||
| 1.06Energy saving Variable frequency drive starter of 40 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature 50 Degree celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make:- L&T/ABB/Schneider/siemens No.3 (ii) Main incomer MCCB of suitable capacity of L&T/ Schneider/ABB/Siemens make on the coming feeder for pumping set confirming to BIS-2516-1985 ( Latest edition) 1 No. 3(iii) LED Three phase inicating lamps complete with logged switches for individual motore confirming to BIS 3452 ( Part I &II) latest with upto date amendments ( 1 No. ) 3(iv) LED On/Off Lincommer MCCB with proper short circuit capability for both the starters make L&T / Schneider / ABB ( 1 No. ) 3(v) On / Off & Trip indicator and push button, control and power wiring Power capacitor ,Cooling fan 230 VAC Control terminal , Buss Bar i.e. Bolt , insulator etc ( 1 No. ) 3( v) Selector switch for Auto and Manual Oparation 1 No. 3 (vi) Input Choke of required HP for Energy saving variable frequencty Starter which shoud be installed at the input of Energy saving variable frenqencty starter, so that there whould be proper protection in case of any voltage surge and distortons 2 No. 3 (vii) Control Transformer Make Surge supressor device with isolating MCCB to circunate the power surges due to lightening and system surges 1 No. 3 (viii) Power and Control Wiring and Busbar 1 No. 3(ix) Installation, commissioning and Software Development 1 NO. 3 (x) Surge supressor debvice with Isolating MCCB toeleminate the power surge due to lightening and system surges 1 o. 3 1 No | |||||||||||
| 1.07(xi) Power quality monitoring & controlling relay with Control Contactor to safeguard Electronic and Electric elements 1 No. 3 (xii) Independent Cont4rol Panel with stiwth Fuse Unit and Fuses fo Suitable Amperage to eliminate the Kit Kat fuses of HPSEB Make Siemens/ Schneider/ L&T 1 No.Automation System for Unmannede Oparatins with SCADA features, PLC, HMI and Level Sensor :- (i) PLC (Programmable logic controller) with appropriate digital and analog and inpute and output to give automatic command to Star Deltar Starer Panel energy saving Variable Freqency Starter Panel Make Aarmation Electric Bechoff Automation/ Rockwell Automatin 1 No. (ii) Electronicrelay card & channel 1 No. (iii) SMPS 4.5 amps to energise PLC system 1 No. (iv) HIMI (Human Machine Interface) 7" display for Monotring and Controllling of Submersibnle pumps Make : Aarmation Electric/ Bechoff Automation / Roackwell 1 No. (v) Conrol MCB for Automation System 1 No. (vi) Level Sensor to indicate the water level of tank remotely 1 No. (vii) Shielded Data Cable for Communation of Level Snsor with PLC 1 No. (viii) Supply of Mobile App (Android IOS) with User ID and Password to monitor and control the pumping oparation from Mobile for 3 users Make Aarmation Electric/ Bechoff Automation Rock well Automation (ix) Could Gate way for Data Clouding to Server 1 No. (x) SCADA soft ware to be installed in Laptop/PC on remotely monitor and control the operation of pumps and also to anysis the pump start and stop history logging fuilt starter, fault history, Power quality Parameters like PE Current Voltage KWH THD etc Make Aarmation electric/ Rockwell Automation Rockwell 1 No. (xi) Cloud space for data storae at cloud/ server 1 No. (xii) Inatallation Commissioning and Software Development. | |||||||||||
| 1.08Supply of Kirloskar/ KSB/Leader make Cast iron double flanged swing check type reflux valve 200mm dia class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for with standing nominal seat presure of 16.22 Kg/Cm2 confirming to BIS 5312-1984 Part-I 1 No | |||||||||||
| 1.09Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.(a) On supply side of 3½ core coper cable 6 mm^2 ( From HPSEB Meter to Switch & Starter). 10.00 mtrs(b) On motor side 3 core flat joint less copper cable of size 4 mm^2 ( From Switch & Starter to Motor) pump installed in the open well 20 mtrs | |||||||||||
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
11 Sept 2025, 5:00 pmClosed
EXECUTIVE ENGINEER JAL SHAKTI DIVISION GHUMARWIN
EXECUTIVE ENGINEER JAL SHAKTI DIVISION GHUMARWIN
Improvement and Augmentation of Lift Irrigation Scheme Chatt Himmer in tehsil Ghumarwin Distt. Bilaspur
2025_HPIPH_113055_1
GMR-BLP02-737(5646-90)Himmer
Open Tender
Civil Works
Item Rate
365 days
Bharari
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
₹3.0 L
19 Nov 2025
27 Aug 2025
12 Sept 2025
27 Aug 2025
11 Sept 2025
27 Aug 2025
27 Aug 2025 - 11 Sept 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .