Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹59.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹65 L+₹5.4 L (9.04%)Rejected-AOC | 2 | Rejected-AOC L2 |
Tender Value
₹65.7 L
EMD Value
₹50,000
Closing Date
15 Oct 2024, 6:55 pmClosed
Chief Electrical Engineer
Office of the Chief Electrical Engineer, PWD Electrical Wing, Public office, TVM
DEPOSIT Providing HT Supply To Institute Of Chest Diseases amp Enhancement of Electrical Installation PWD General Electrical Work
2024_PWD_694232_1
PWD/BLDG/TR/6149/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
240 days
KOZHIKODE MCH
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
Yes
17 Dec 2024
4 Oct 2024
18 Oct 2024
4 Oct 2024
15 Oct 2024
4 Oct 2024
4 Oct 2024 - 15 Oct 2024
Amount
Modernization of Institute of Chest Diseases attached to Government Medical College , Kozhikode. Priding HT Supply
OD275792/2022-2023:SITC of 500KVA USS , 11kv/433v,50hz,3phase,AN cooled, delta/star,with copper windings with tappings +5 to -5 in steps of 2.5%, class f insulation, Indoor type ,laser scribed core ,confirming to ECBC norms , copper interconnections , with 11KV,630A, VCB ,26.3KA for 3 sec, horizontal drawout fitted with manual spring charged etc complete with necessary multifunction meter ,11KV CT & PT ,master trip relay, push button ,provision for TOD meter, annunciation panel with alarm,strip heater, thermostat etc complete enclosed in CRCA powder coated sheet conforming to IP 23 of minimum thickness 2mm.
OD138105/2024-2025:SITC of Indoor, Metal Clad, Horizontal Isolation Horizontal Draw out type 630A VCB addon panel confirming to IEC62271-200, IEC-62271 1 1.2/50 micro sec. Impulse Withstand Voltage 75kVp NO OF PHASES 3 FREQUENCY 50 HZ +/- 3% SHORT CIRCUIT RATING Peak Withstand Current 62.5kAp Short Time Current for 3 sec.. 25kArms DEGREE OF PROTECTION IP4X NO OF HV COMPARTMENTS Three (3) - Breaker, Busbar and Cable TYPE OF SHEET STEEL Aluzinc, Doors & Covers with Painted CRCA SHEET STEEL THICKNESS Load Bearing Members 2 mm Others 1.5 mm SURFACE TREATMENT PROCESS 9 Tank Process 1 SWITCHGEAR ASSEMBLY REFERENCE STANDARD IEC62271-200, IEC-62271-1 TYPE OF SWITCHGEAR Indoor, Metal Clad, Horizontal Isolation Horizontal Drawout VOLTAGE Nominal System Voltage 11kV Rated Voltage 12kV 1 min. Power Frequency Withstand Voltage 28kV 1.2/50 micro sec. Impulse Withstand Voltage 75kVp NO OF PHASES 3 FREQUENCY 50 HZ +/- 3% SHORT CIRCUIT RATING Peak Withstand Current 62.5kAp Short Time Current for 3 sec.. 25kArms DEGREE OF PROTECTION IP4X NO OF HV COMPARTMENTS Three (3) - Breaker, Busbar and Cable TYPE OF SHEET STEEL Aluzinc, Doors & Covers with Painted CRCA . SHEET STEEL THICKNESS Load Bearing Members 2 mm Others 1.5 mm SURFACE TREATMENT PROCESS 9 Tank Process PAINTING Paint Thickness 60-80microns Standard Paint Shade RAL 9003, Powder coating with texture finish SERVICE, TEST & DISCONNECTED POSITION Yes INSIDE THE CUBICLE MINIMUM CLEARANCE IN AIR Not applicable as all live parts insulated/shrouded, clearance below for fully insulated/interposing barrier between Interrupters. MINIMUM CLEAR SPACE REQUIRED Front for Breaker Withdrawal 1500mm Rear 1000mm GROUNDING Material of Earth Bar Half Hard, Hard drawn, High Conductivity Copper as per IS-613. Size of Earth Bar 30mmX6mm Bus Side Earthing Through earthing truck Line Side Earthing Through earthing truck OVERALL DIMENSIONS Standard Panel Shipping Dimensions (W X D X H) 600/800 mm X 1870mm X 1394mm (W/o LV Comp.) OVERALL WEIGHT WITH VCB (in kg.) 350Kg APPROXIMATE MAXIMUM DYNAMIC WEIGHT FOR Negligible shock load as compared to dead weight of the FOUNDATION DESIGN cubicle DESIGN AMBIENT TEMPERATURE 40 °C BREAKER/ CUBICLE ACCESSORIES Mechanical Safety Interlocks As per Clause 5.106, IEC 62271-200 / IS 3427 Automatic Safety Shutters Positively driven Shutters, provision for Emergency Manual Trip , Mechanical On-Off Indicator , Operation Counter,Spring Charge-Discharge Indication, Manual Spring Charging Facility Padlocking of Breaker in Test & Service position , with standard size bus bar and chamber , 800A VCB, cable entry boxes, necessary contactors, relays, protective devices, meters, indications lamps, all accessories etc as required.
OD1431/2022-2023:Supply and laying 3 core 300 sqm 11 kV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in existing DWC Pipe and giving connection as required.
OD1430/2022-2023:Supply and laying 3 core 300 sqm 11 kV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
3.13.4:Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.800 amps 50 KA SC for 1 sec
14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD281470/2022-2023:Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled elliptical shaped bulk head fittings directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.
OD1409/2022-2023:Supply and providing the 9W LED lamp in the existing fittings as required (Division observed data)
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
OD141260/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
OD217273/2023-2024:Supply, conveyance, installation , testing and commissioning of 450 mm sweep 1400rpm Heavy Duty Exhaust fan in metal frame in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.12.5.35:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm
90.12.6.35:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm
90.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
90.12.6.34:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
90.12.5.32:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mm
90.12.6.32:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.27:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
90.12.10.5:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation90/75 mm or nearest size
90.12.10.11:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation175/147 mm or nearest size
90.12.12.11:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation175/147 mm or nearest size
OD3233/2022-2023:Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD1413/2022-2023:Supply and providing 25x3mm brass bolt
OD1414/2022-2023:Supply and providing 12x3mm brass nut and bolt etc. as required.
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22:Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD1417/2022-2023:Supply and fixing 400/5A 10 VA accuracy class 1,Resin cast metering CT and giving connection as required.
OD269058/2022-2023:Supply and fixing 200/5A 10 VA accuracy class 1,Resin cast metering CT and giving connection as required.
OD43909/2024-2025:250/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT
OD1418/2022-2023:Supply and fixing 800/5A 10 VA accuracy class 1,Resin cast metering CT and giving connection as required.
OD1419/2022-2023:Supply and providing Multi function meter to read: V, A, F, 3 phase accuracy class 1
OD1420/2022-2023:Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators, AC/DC 22.5mm cut out dia
OD1421/2022-2023:Supply and providing 2A SP MCB suitable mounded on panel boards as required including all charges
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.13:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.17:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.8.16:800 A, 4 pole, electrical draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA
OD39324/2024-2025:Supply , installation , testing and commissioning of Digital Restricted Earth fault relay , size 100mm or above , 275V ,
OD39326/2024-2025: Supply and installation of Closing coil of ACB (220-250A AC/DC)
OD39327/2024-2025: Supply and installation of Shunt trip coil of ACB (220-250V)
OD39328/2024-2025:Supply and installation of Under voltage release coil of ACB (220-250A AC/DC)
90.14.10.2:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
OD1423/2022-2023:Supply and fixing Spreader terminals suitable for 320/400A 4Pole MCCB (Set of 8)
OD1424/2022-2023:Supply and fixing Spreader/ terminal adapter kit Extended terminal for 4 pole MCCB of rating up to 125 A (8 Pcs)
OD1425/2022-2023:Supply and fixing Spreader terminals suitable for 200A to 250A 4Pole MCCB (Set of 8)
OD44022/2024-2025:Supply and fixing of Spreader Terminals adaptors kit 8 piece for MCCB up to 160A
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.6:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD1432/2022-2023:Steel reinforcement for RCC work including straightening , cutting , bending and placing in position and binding all complete.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
OD141237/2024-2025:Supplying and laying 25x3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.10:Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
5.20:Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
OD1433/2022-2023:Supply and providng 14 stage 440 / 110V, 5/1A intelligent power factor controller in the existing panel board and giving connection
90.14.24.68:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.71:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.73:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.75:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.25 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
OD1434/2022-2023:Supply and fixing of Power Capacitor Duty Contactor for switching capacitor banks 4 to 7 KVAR rating with AC coil and 1 NO Contact.
OD1435/2022-2023:Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 7.5 - 10 kVAR with AC Coil, in the existing panel board and giving connection.
OD1436/2022-2023:Supply and fixing of Power Capacitor Duty Contactor for switching capacitor banks 15 kVAR rating with AC coil and 1 NO Contact.
OD1437/2022-2023:Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 25 kVAR with AC Coil, in the existing panel board and giving connection.
OD141222/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.2.50sq mm wire single run
OD141223/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.1.50sq mm wire single run
OD141224/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.4.00sq mm wire single run
OD141225/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.10.00sq mm wire single run
OD141226/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.6.00sq mm wire single run
OD1445/2022-2023:Supply and fixing Digital Three phase volt meter accuracy 0.5 to read Phase Voltage & Line Voltage
OD1446/2022-2023:Supply and providing Single Phase Ammeter accuracy class 1 in the existing panel board and giving connection.
OD1449/2022-2023:Illuminated flush head Push Button with LED
OD1454/2022-2023:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
OD1455/2022-2023:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
OD1456/2022-2023:Painting letters or figures of the 2.5 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, Panel board as required.
OD1457/2022-2023:Supply and providing Cable alley, 100 x 40 mm aluminium anodised legend plates in the existing panel board as required.
OD275789/2022-2023:Supply,installation,testing and commissioning of 2KVA UPS a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : ≤ 10% f) Overall Efficiency : 87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. k) 3 year warranty. l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) battery approved make exide / quanta/panasonic
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.2:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD281206/2022-2023:Supply and providing First aid chart duly framed and placed in a conspicuous location for clear vision.
OD281207/2022-2023:Supply and providing 4.5 CO2 type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD281210/2022-2023:Supply and providing Fire Escape Route size not less than 16'x16' as required
OD281212/2022-2023:Supply and providing 9 litre capacity GI Fire bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand painting the bracket/ floor stand including making good the damages, colour washing etc as required.
OD281213/2022-2023:Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.
OD281682/2022-2023:Supplying,installing,testing and commissioning of Electronic dual tone Hooter(sounder) as per standard specification.
OD281939/2022-2023:Supply, Conveyance, Installation, Testing and Commissioning 12 window programable annunciator 85to 270V AC/DC ,
OD141051/2024-2025:Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe,GI funnel with weld mesh,25x5 mm GI clamps,CI/MS cover plate with locking arrangements,charcoal/coke and salt etc including providing brick work masonry enclosure at the top (450x450x450mm inside)etc as required.
OD141060/2024-2025:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm tinned copper strip
90.16.4.6:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).40 x 6 mm GI strip
90.16.4.11:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm copper strip
OD46662/2024-2025: Supply and clamping of 1.5 sqmm 12 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE
90.16.3.7:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)50 x 6 mm GI strip
OD46782/2024-2025:Supply and installation of 160 A, 415V, AC 4P Motorized On load Changeover Switch( along with Automatic Transfer Controllers (ATC) for Motorized Changeover with wire harness Dis connector in the existing panel board with illuminated push button assembly with wire harness drilling holes in cubicle panel, and giving necessary connections, testing and commissioning etc as required for auto start operation for existing DG set,. as required.
SOUBHAGYA ENGINEERING COMPANY
Bidder Name
Kittu Electricals private limited
SOUBHAGYA ENGINEERING COMPANY
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1081631.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .