REPAIR AND MAINT OF VRV-III AC PLANT LOCATED IN NTC AT DEFENCE LAB JODHPUR
2026_MES_789703_1
8762/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
JODHPUR
as per tender document
7 documents required · 7 mandatory
₹500
AGE I R AND D JODHPUR
₹38,000
Yes
12 Oct 2026
12 Oct 2026
9 Nov 2026
12 Oct 2026
2 Nov 2026
27 Oct 2026
13 Oct 2026 - 26 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | carrying out Comprensive daily Maintenance, of VRV/VRF air conditioning plant details are as under on each working day or anytime at breakdown by sufficient trained mechanic with helper attending complaints ,finding faults and rectifiying defects within reasonable time as directed by Engr-in-Charge.All outdoor and indoor unit shall be checked throughly for gas leakage,including minor breazing,soldering ,minor parts such as tapping ,washers ,clamps ,nuts & bolts which are not covered under supply only here in after as supply only to be paid separately: (A) Outdoor Units:- Outdoor units consists of compressor, heat exchanger, condenser fan, auto check function for error, Auto address setting microprocessor panel, isolating valves for the following capacity. Heat pump type (Cooling and Heating) of 10 Hp - 04 Nos Cooling and Heating type 12 Hp - 09 Nos Cooling and Heating type 14 Hp - 02 Nos Cooling and Heating type 16 Hp - 01 Nos Cooling and Heating type 18 Hp - 04 Nos (Total 20 Main units and 04 slave unit = 24 Outdoor units) (B) Indoor units:- Indoor unit addressing multispeed motor oil section with DX coil outer consist drain pipe water lift mechanism its insulation pipe connection fresh air intake sysem with the following capacities. Ceiling mounted Cassette type 2.6 TR - 09 Nos Ceiling mounted Cassette type 3.3 TR - 07 Nos Split high wall mounted type of different capacity - 138 Nos (Total 154 indoor units)Note for Srl item No.1: (I) Payment shall be made monthly Basis. (ii) Payment shall be made one for month but work shall be done each day as required to make plant functional (24x7) days (except major fault). (iii) All tools and plants shall be provided by contractor. | 11 | Month | - | - |
| 2 | M&L for servicing of Daikin VRV-III ( indoor unit) at the existing location with suitable electronic machine, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower,rewinding, assembling, testing and commissioning etc complete all as specified and directed by Engr-in-charge. | 154 | Unit | - | - |
| 3 | M&L for servicing of Daikin VRV-III including (outdoor unit) at the existing location with suitable electronic machine, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower,rewinding, assembling, testing and commissioning etc complete all as specified and directed by Engr-in-charge. | 24 | unit | - | - |
| 4 | Supply and charging of gas R- 410A inside the compressor and testing Complete all as specified and as directed by Engr-in-Charge. | 160 | KG | - | - |
| 5 | S&F in replacement Remote controller for indoor unit as per sample Complete all as specified and as directed by Engr-in-Charge. | 10 | Each | - | - |
| 6 | Repair of Printed Circuit Board for indoor unit of any capacity and any type including all connected wiring , connectors, adopter etc required at site complete all as specified and as directed by Engr-in-Charge. | 10 | Each | - | - |
| 7 | Supply only Printed Circuit Board for indoor unit of any capacity and any type including all connected wiring , connectors, adopter etc required at site complete all as specified and as directed by Engr-in-Charge. | 5 | Each | - | - |
| 8 | Supply only Remote control PCB for indoor unit any capacity and any type including all connected wiring , connectors, adopter etc required at site complete all as specified and as directed by Engr-in-Charge. | 5 | Each | - | - |
| 9 | supply only indoor Expansion Valve of any size required at site all as specified and directed by Engr-in -Charge. | 5 | Each | - | - |
| 10 | supply only indoor expansion valve coil of any size required at site all as specified and directed by engr-in-charge. | 5 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_885250.xls
BOQ • 5.24 MB
PS.pdf
Tender Documents • 1.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .