Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹14.0 L+₹6,874 (0.49%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹14.4 L+₹50,966 (3.66%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹15.0 L+₹1.1 L (7.67%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹16.4 L+₹2.5 L (18.0%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
CLEANING OF OH TANK, UNDERGROUND SUMP AND CONNECTED WORKS AT AF STN PHALODI
2020_MES_407962_1
8327/A/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category a(ii) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹40,000
Yes
8 Feb 2021
29 Dec 2020
27 Jan 2021
29 Dec 2020
25 Jan 2021
13 Jan 2021
29 Dec 2020 - 8 Jan 2021
Amount
M & L for cleaning and desilting of RCC over head tank (50000 Gallon Capacity) any depth by pumping out /removing liquid waste/sewage with, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements, face mask etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the tank with fresh water etc complete all as specified and directed. Note :- (a) Cleaning and desiliting of RCC over head tank shall be carried in stages as under :- Stage-I :- Dewatering the tank with portable submersible pump set flowable of 30000 Ltrs/Hrs. Stage-II :- Desilting and removal of left over dirty water and sludge with a special sludge removal pump. Stage-III :- Cleaning of wall, ceiling and floor by high pressure water jet with the help of German equipments which creates pressure of 80-120 bar. Stage-IV :- Removal of remaining sludge from the floor with the help of high pressured industrial vacuum cleaner. Stage-V :- Spraying of bio degradable, eco friendly antibactirial agent certified by NTC a government approved lab to disinfect the tank from all harmful pathogens. The doze utilized for safe as per the OECD Guidelines 423 adopted is as on 17 Dec 2001. Stage-VI :-Treatment of inside tank by exposing UV radiation to kill to further suspended or floating bacteria, write cleaning of tanks date with black enemel paint on white background. Stage-VII :- Removal of remaining sludge from the floor with the help of high pressured industrial vacuum cleaner. (b) All necessary equipment of machinery, T & P, transportation etc shall be arranged by contractor and quoted rate shall be deemed to included of the same.
All ditto as per item No 1.00 (here-in-before) but RCC Under Ground Sump (50000 Gallon Capacity) static water tank complete all as specified and directed.
All ditto as per item No 1.00 (here-in-before) but RCC Under Ground Sump (150000 Gallon Capacity) static water tank complete all as specified and directed.
M & L for taking out of submersible pump set of any capacity alongwith column pipe 80mm dia and cable from the bore well of encasing pipe 200 mm bore (length approx 170 mtr) after dismantling existing GI bend 80 mm bore from NRV and disconnecting submersible cable from starter complete all as specified and directed. Note :- The quoted rates shall be deemed to include for requisite T&P, equipments, transportation etc.
M & L for lowering down of submersible pump set of any capacity alongwith connected items such as column pipes & submersible cable (length approx 170 mtr) re-connecting, commissioning and testing complete all as specified and directed. Note :- The quoted rates shall be deemed to include for requisite T&P, equipments, transportation etc.
M & L for re-winding of 40 HP submersible pumps motor, electric driven 415 Volt, 50 Hz, 3 phase AC supply with PVC insulated, Super enamelled Copper winding wire of suitable/existing gauge, ISI marked and including all insulated material such as adhesive, insulating paper steeves, tape etc. and connected works for rewinding & including assembling and reassembling the motor complete all as specified and directed. Note :- The quoted rates shall be deemed to include dismantling, removal of old winding wire, cleaning of slots and reassembling complete. Make of winding wire :- Finolex, Havells and Polycab.
All ditto as per item No 6.00 (here-in-before) but 30 HP capacity complete all as specified and directed.
All ditto as per item No 6.00 (here-in-before) but 20 HP capacity complete all as specified and directed.
M & L for dismantling of 40 HP capacity submersible pump, multi stage examining for worn out/defective parts and renewal defective parts, cleaning properly, thereafter reassembling the pump, commissioning and testing complete all as specified and directed.
All ditto as per item No 9.00 (here-in-before) but 30 HP capacity complete all as specified and directed.
All ditto as per item No 9.00 (here-in-before) but 20 HP capacity complete all as specified and directed. Note for item Nos :- 9.00 & 11.00 :- (i) The spare parts to be replaced shall be measured and paid for separately as 'supply only' (here-in-after) under relevant items of BOQ. (ii) The quoted rate shall be deemed to include for necessary T&P, equipment, transportation etc required to repair submersible motor of any capacity complete. (iii) Make of spare parts shall be as per original manufactrurer of submersible pump.
Supply only Upper and lower rubber housing bush, 3 phase, 50 Hz AC submersible motor of 40 HP capacity for replacement under item No. 9.00 (here-in-before) complete all as specified and directed.
All ditto as per item No. 12.00 (here-in-before) but Stainless steel rotor sleeve complete all as specified and directed.
All ditto as per item No. 12.00 (here-in-before) but Carbon thrust bearing complete set complete all as specified and directed.
All ditto as per item No. 12.00 (here-in-before) but Upper and lower CI housing complete all as specified and directed.
Supply only Upper and lower rubber housing bush, 3 phase, 50 Hz AC submersible motor of 30 HP capacity for renewal under item No. 10.00 (here-in-before) complete all as specified and directed.
All ditto as per item No. 16.00 (here-in-before) but Stainless steel rotor sleeve complete all as specified and directed.
All ditto as per item No. 16.00 (here-in-before) but Carbon thrust bearing complete set complete all as specified and directed.
All ditto as per item No. 16.00 (here-in-before) but Upper and lower CI housing complete all as specified and directed.
Supply only Upper and lower rubber housing bush, 3 phase, 50 Hz AC submersible motor of 20 HP capacity for renewal under item No. 11.00 (here-in-before) complete all as specified and directed.
All ditto as per item No. 20.00 (here-in-before) but Stainless steel rotor sleeve complete all as specified and directed.
All ditto as per item No. 20.00 (here-in-before) but Carbon thrust bearing complete set complete all as specified and directed.
All ditto as per item No. 20.00 (here-in-before) but Upper and lower CI housing complete all as specified and directed.
Supply only rotor assembly for 40 HP capacity of submersible motor to match with existing make and size for renewal under item No. 9.00 (here-in-before) complete all as directed and specified
Supply only rotor assembly for 30 HP capacity of submersible motor to match with existing make and size for replacement under item No. 10.00 (here-in-before) complete all as directed and specified
Supply only rotor assembly for 20 HP capacity of submersible motor to match with existing make and size for replacement under item No. 11.00 (here -in-before) complete all as directed and specified
Supply only Half coupling stainless steel with key of multistage submersible pumps of capacity 20 HP, 30 HP or 40 HP for renewal under item Nos. 9.00, 10.00 & 11.00 (here-in-before) complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Discharge outlet CI complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Stage casing CI complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Gun metal sand guard complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Gun metal impeller complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Gun metal neck ring complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Stainless steel distance bush complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but CI suction housing complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Studs for suction housing complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Gun metal body bush complete all as specified and directed.
All ditto as per item No. 27.00 (here-in-before) but Stainless steel connection piece (adaptor) complete all as specified and directed.
S & F in renewal of Cosmic Star- Standard automatic star delta Submersible motor starter in steel sheet enclosure AC, 3 phase, 415 Volts, 50 Hz type MUG with single phase preventer, dry run preventer, overload protection, reverese phase protection suitable for 40 HP submersible pump set (Contactor size 95 Amps, Overload Relay Range 55 to 70 Amps) complete all as specified and directed.
S & F in renewal of Cosmic Star- Standard automatic star delta Submersible motor starter in steel sheet enclosure AC 3 phase, 415 Volts, 50 Hz type MUG with single phase preventer, dry run preventer, overload protection, reverese phase protection suitable for 30 HP submersible pump set (Contactor size 65 Amps, Overload Relay Range 37 to 50 Amps) complete all as specified and directed.
S & F in renewal of 3 pole power contactor 65 Amps with AC coil, AC 3 duty rating, 415 Volts, 50Hz of motor starter complete all as specified and directed. Make :- Cat Part No. IHPAA065511 of Havells or equivalent Make and Model of Schneider/ C&S / L & T.
All ditto as per item No. 40.00 (here-in-before) but 40 Amps complete all as specified and directed. Make :- Cat Part No. IHPAA04051 of Havells or equivalent Make and Model of Schneider/ C&S /L & T.
All ditto as per item No. 40.00 (here-in-before) but Pneumatic Timer block on delay 10-180S complete all as specified and directed. Make :- Cat Part No. IHNF6000 of Havells or equivalent Make and Model of Schneider/ C&S / L & T.
All ditto as per item No. 40.00 (here-in-before) but thermal Overload Relay (Auto/Manual Reset) range 55 to 70 Amps complete all as specified and directed. Make :- Cat Part No. IHNR33AX of Havells or equivalent Make and Model of Schneider/ C&S /L & T.
M & L in renewal of MCCB 4 pole 160 Amps thermal adjustable setting 0.8 to 1ln, magnetic fixed setting at 10 ln, breaking capacity, 25 KA, AC, 415 Volt and conforming to IEC:60947-II/IS : 13947-II complete all as specified and directed. Make :- Model d sine, Cat Part No. CM9064OONO of L & T or equivalent Make and Model as mentioned in Appendix 'D' of tender documents.
M & L in renewal of MCCB 4 Pole, 100 Amps, thermal adjustable setting 0.8 to 1ln, magnetic fixed setting at 10ln breaking capacity, 25 KA, AC, 415 Volt and conforming to IEC:60947-II/IS : 13947-II complete all as specified and directed. Make :- Model d sine, Cat Part No. CM9064OOLO of L & T or equivalent Make and Model as mentioned in Appendix 'D' of tender documents.
S & F in renewal of rubber gasket at both ends of flanged column suitable for GI column pipe of 80mm dia complete all as specified and directed.
M & L in renewal of nut and bolt with washer, heavy grade suitable for GI flanged column pipes of 80mm dia complete all as specified and directed.
M & L in renewal of GI column pipe 6 meters length (Each), medium grade, 80mm bore dia with welded flages at both ends, ISI marked and including dismantling holes/spot in flange complete all as specified and directed.
S & F in renewal of submersible cable water proof of size 3 core 10 Sqmm PVC Insulated and PVC sheathed, flat, LT 1100 Volts grade with copper conductor & including jointing and lowering in tube well with column pipe for star delta connection of pump set complete all as specified and directed.
S & F in renewal of submersible cable water proof of size 3 core 16 Sqmm PVC Insulated and PVC sheathed, flat, LT 1100 Volts grade with copper conductor & including jointing and lowering in tube well with column pipe for star delta connection of pump set complete all as specified and directed.
M & L for rewinding the electric motor including disconnecting electric and earth connections, decoupling motor and centrifugal pump, removing foundation bolts and nuts and removing the motor from its existing position of following Capacity, 3 phase, 415 Volts of existing Make and taking out to civil workshop for carrying out repairs/ rewinding as under complete all as specified and directed:- (a) Removing the split case/body cover of motor, separate starter/rotor and cutting the complete burnt/defective winding. (b) Cleaning the stater body complete by rubbing sand paper and remove all carbon. (c) Insert insulation material such as insulating paper sleeves. (d) Rewinding the stator with existing size and guage of Super enamelled Copper winding wire, varnishing and heating up at desired temp for achieving the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Opening of the centrifugal pump, grinding of the shaft, changing the bushes, gland packing and the bearings complete with oiling, greasing etc. (g) Connection/coupling the motor with pump & connect all earth/electric connections, foundations nut bolts at its original position and testing on load complete. (h) Painting of the pump set & its foundation with two coat of synthetic enamel paint after preparation of surfaces complete. (j) The quoted rates shall also be deemed to included deassembling and reassembling the motor & pump after rewinding/repair, T & P, equipments, transportation etc complete. (k) Make of parts shall be as per original manufactrurer of electric motor. (l) Make of wiring wire :- Finolex/ Havells / Polycab.
Electric motor pump set of 40 HP Capacity
Electric motor pump set of 10 to 15 HP Capacity
Electric motor pump set of 5 to 7.5 HP Capacity
Taking up or down 50mm bore dia steel tubing and connections including cleaning for refixing or removal complete all as specified and directed. Note :- Excavation and earthwork shall be measured and paid separately under respective items of BOQ here-in-after.
Taking up or down 80mm bore dia steel tubing and connections including cleaning for refixing or removal complete all as specified and directed. Note :- Excavation and earthwork shall be measured and paid separately under respective items of BOQ here-in-after.
S & F 50mm bore dia steel water tubing, galvanized, medium grade, ISI marked & including with all fittings such as GI, sockets, elbow, bends, tees, union etc, laid in trenches and connecting to water supply line and testing complete all as specified and directed.
S & F 80mm bore dia steel water tubing, galvanized, medium grade, ISI marked & including with all fittings such as GI, sockets, elbow, bends, tees, union etc, laid in trenches and connecting to water supply line and testing complete all as specified and directed.
M & L in renewal of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, heavy duty with ISI marked and fixed of size 25mm bore dia complete all as specified and directed.
M & L in renewal of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, heavy duty with ISI marked and fixed of size 40mm bore dia complete all as specified and directed.
M & L in renewal of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, heavy duty with ISI marked and fixed of size 50mm bore dia complete all as specified and directed.
M & L in renewal of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, heavy duty with ISI marked and fixed of size 80mm bore dia complete all as specified and directed.
M & L in renewal of clip joint (standard) with rubber packing to stop the water line leakage upto 80 mm dia GI pipe line complete all as specified and directed.
M & L in renewal of clip joint (standard) with rubber packing to stop the water line leakage from 100mm dia to 250 mm dia CI pipe line complete all as specified and directed.
S & F in renewal of RO membrane suitable for discharge 2.5 Cum/Hr capacity RO plant (model 4040), including connected accessories complete all as specified and directed. Make :- Torrey/Hydronatics.
S & F in renewal of RO membrane suitable for discharge 3 Cum/Hr capacity, Spiral type, MOC - Celluluse Polyamide, filteration grade - 90-98% salt rejection, Make/Model : Torrey Japan/8040 & including connected accessories complete all as specified and directed.
M & L for repair and servicing, testing of Chemical dosing (Metering) Pump electromagnet type with suction & discharge tubing, Spring loaded anti siphon valve, foot valve and replacement of broken storage tank 100ltr capacity etc complete all as specified and directed.
M & L for construction of stone masonary valve pit chamber 900mm X 600mm X 1000mm (internal dimension) with stone masonary, built in CM 1:6, PCC 1:4:8, type D-2 as in foundation concrete bed/ floor coping and 100mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below ground level and mixed with water proofing compound @ 3% by weight of cement with and including MS cover 03 mm thick sheet with locking arrangements & including excavation and earth work in soft/loose soil, painting sheet cover with two coat of black bituminous paint over a coat of red oxide primer complete all as shown on TD drawings and including demolition of old unserviceable valve pit chamber complete all as specified and directed. Note :- (i) Drg No TD/2004/26/ Sheet Nos. 1/3 to 3/3. (ii) Valve pit shall type 'C' but size shall be as mentioned above.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth (or n exc 10 Sqm on plan and n exc 1.5 m in depth) & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth (or n exc 10 Sqm on plan and n exc 1.5 m in depth) & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in hard/dence soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose or hard/dence soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M/S SOLANKI GENERAL SUPPLIERS
KRISHNA CONSTRUCTION COMPANY
LADDOS BUILDCON
M/S HARIOM CONSTRUCTION COMPANY
SHIVA BUILDERS
vijay enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .