Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 CrAccepted-AOC | ₹29.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹31.2 CrRejected-AOC | ₹31.2 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹27.2 Cr
EMD Value
₹5 L
Closing Date
10 Aug 2023, 11:00 amClosed
Superintending Engineer
Office of the Superintending Engineer, Public Health Circle, Kottayam, Kerala Water Authority
SUPPLYING, ERECTING RAW WATER PUMP SETS, SUPPLYING AND LAYING RWPM, SUPPLYING AND ERECTING TRANSFORMER AT INTAKE AND WTP SITE ,POWER ALLOCATION ,MAINTENANCE OF EXISTING 9 M DIA WELL CUM PUMPHOUSE, RETAINING WALL AND OPERATORS RESTROOM AT ULLOORPADY
2023_KWA_588723_1
WRD/KWA-CE(SR)/TR /8631/2022_26_20_19/1
Open Tender
Civil Works - Water Works
365 days
Nedumkunnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹16,540
₹5 L
O/o the SE, PHC, KWA Kottayam
29 Nov 2023
20 Jul 2023
11 Aug 2023
20 Jul 2023
10 Aug 2023
20 Jul 2023
20 Jul 2023 - 24 Jul 2023
24 Jul 2023
Amount
1A.Maintenance & repair works at Raw water pump house site Ulloorpady
OD41112/2023-2024:Consultancy and Design charges for retrofitting the Raw water pumphouse at Ulloorpady to accommodate newly proposed 3 nos VT pump sets by Project Division Kottayam & 3 nos VT pumpsets by P H Sub-Division Changanassery along with its starter panels, common header pumping main, necessary control valves, gantry crane for the lifting of pump sets for repair, design of leading pipe inet,surge analysis of raw water pumping mains,and vetting from WASCON,KWA ,verification and approval of structural drawings, providing necessary tech help etc.
OD41775/2023-2024:Conveying building debris from raw water site at Ulloorpady to desired location as directed by Engineer-in-charge within 5 km lead.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
OD41069/2023-2024:Constructing ring bund of top width 2.00 m, bottom width 4.00 m and height 3.00 m by using earth filled cement bag on both faces and filling clay for puddle and for dismantling after completing work etc. complete
100.52.S.1:Sub Data for providing Earth filled cement bags including cutting of the Earth, filling, conveying and placing in position.
100.6.1:Providing steel sheet shoring to the sides of the trenches to depths of above 4.00 m but not exceeding 6.00m using 6 mm M.S. sheet 0.50 M wide stiffen on edges with 50 mm x 50mm x 6 mm M.S. angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.5 M above ground level suitably braced by horizontal walling pieces at 75 x 150 mm x 8 mm angles on either side at intervals not exceeding 1.50M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed, dismantling, cleaning and restacking for reuse including all labour, hire charges and conveyance for equipments, tools and plants and sundries etc. complete.
100.54.3.1:Desilting open wells of dia above 3.5m and up to 6.0m and depth up to 4.5m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the steining by engaging divers with breathing accessories, bailing out water using pump set of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m from the periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations, including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete.
OD75634/2023-2024: DOWEL BARS - Supplying and Providing MS dowel bars of size 25 mm dia of 2.0m long (1m in rock and 1m in concrete ) including drilling holes of 30mm dia or more and filling the gap with HIT-RE 500 V4 INJECTION MORTAR /under water etc complete
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
OD5987/2023-2024:Design, manufacturing, assembling, testing, transporting, delivery at site, required fabrication,final painting, installation at site, trail running, commissioning , performance testing of 8 ton capacity EOT crane with necessary mechanical, electrical and civil works including fitting, fixers and accessories. The crane shall be comforting to IS 3177, IS 807, IS 2266, IS 13834 (Part 1 & 5), IS 325, IS 5749, IS 800, ISO 12488-1. The crane shall be having bridge structure,long travel sporting girder, travelling mechanism for long and cross travel, track wheel for long and cross travels, trolley, hoisting mechanism, break mechanism separately for long, cross and hoisting pendant control with remote operation of all movements electrical motors, control gear and equipment, AC variable frequency controls and all motions of the crane, providing suitable rails etc with necessary civil works required at site. All electrical components, trailing/flexible cables, protective switch gears, motor and control panels and power and control cables, CT Motion cables shall running cable rag chain IGUS Drag link cable system, pended and wireless remote, earthing as per IE rules, shrouded bus bar GI conductor etc complete all electrical accessories of the satisfactory completion of the girder as per the direction of deptl: officers. 1. Hoisting capacity - 8 Ton, 2. Span - 6.00m, 3. Long Travel - 8.00m, 4. Lifting rang - 6.00m, 5. Main hoist speed - 3m/min (Max), 6. Long travel speed - 20m/min (max), 7. Cross travel speed - 16m/min (max), 8. Duty class of crane M7, 9. Materials for equipment and structure as per IS 2062(latest), 10. Wire rope - Galvanized type of 6x36 construction with tensile strength not less than 180Kg/mm2. 11. Gears as per IS 4460 -1967 or latest. 12. Breaks for LT and CT with fail safe DC disc type, hoisting break with electro hydraulic thruster break and fail safe DC disc type, 13. Rail wheels with minimum hardness 320 VHN, 14. Lifting hook as per IS 3815 and IS 8610
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
24.2:Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube chakkus, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.
13.71:Lettering with black Japan pint of approved brand and manufacture
OD4521/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity),Supply and laying 25x3mm required length of GI strip through epoxy resign cast support,Down conductor through wall vertical run/through parapet,Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet,Supply and laying of 32x6mm GI strip through ground including earth work excavation back filling and jointing etc complete and providing 2 Nos of pipe earthi
OD41114/2023-2024:Supplying 560 mm dia MH cover with frame (Heavy duty)
OD41400/2023-2024:Supply, installation, testing, and commissioning of electrical all items in connection with Raw water pumphouse, transformer room, operator room and all other components within Raw water pump house premises like wiring materials, wiring with suitable quality wires with sufficient number of Light(36 w led tube lights evenly fitted as minimum Two numbers per 50 sq feet), Fan(Minimum one number per 100 sq feet), Minimum three plug points of light and one for Power per 100 sq feet and other necessary switches and plug points of suitable ratings wherever necessary as per direction of departmental officers subject to the condition that minimum 1 fan , 2 led 36 w lights, 2 plug points, and one power plug in each room and as per design of raw water pumphouse & transformer room for the satisfactory completion of the work, Yard lighting works as directed by departmental officers etc. All electrical works including TOD Meter, CTPT Units, Protective equipments, Cable laying works and its connections, All electrical Panel Boards, 11KV substation works, RMU works, vacuum circuit breaker works, indoor Transformer installation related works(HT & LT),cubicle works, earthing ,Panel board works, UG cable works, APFC works, Capacitor panel works, HTpanel boards, LT panel board works, Lead acid cell battery charger, automatic twin battery charger works, safety works & items approved by Kerala Electrical Inspectorate, wiring works, electrical wiring works for the buildings with the ceiling fans, exhaust fans, LED lights, Yard lighting work as per direction of the departmental officers, ,lightening arresters, drawings for the electrical inspectorate.(All the works must be in accordance with Electrical Inspectorate standards.) ,CCTV works for all the areas within the RWPH premises & outside, etc. and all other electrical works for the satisfactory completion of the electrical works. All paper and allied works with necessary statutory fees at Electrical inspectorate and KSEB Limited for approval and to be got approved by Electrical Inspectorate and connection from KSEBL. All the approved diagrams and reciepts from KSEBL and Inspectorate in original must be submitted to plant in charge after successful commissioning of the electrical items
1B.Construction of Transformer room and operating room at RWPH premises
20.2.1:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).300 mm dia piles
20.6.1.2:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile upto 50 tonne capacityRoutine test
20.8.1:Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 ( Part IV) for determining safe allowable lateral load on pile:Upto 50 tonne capacity pile.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
OD9446/2023-2024:Supplying and fixing Ready-made RCC septic tank having size 1000mm dia and 2500mm long including soak pit, earthwork, conveyance charges, and fixing charges including materials etc complete.
17.7.3:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
24.2:Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube chakkus, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.
13.71:Lettering with black Japan pint of approved brand and manufacture
1C.Supply, erection,testing and commissioning of the RAW WATER pump sets, flowmeter and associated pipeline works
OD83011/2023-2024:Design, testing, Supply, erection, trial run and commissioning of Vertical Turbine,Variable Frequency Drive (VFD) Starter<br>Pumpsets 152 lps against a total head of 111m (2 Nos running at a time and one stand by) )and having 1500 rpm sync. Speed, Bronze<br>LTB2 Impeller, SS 316 shaft, cast iron casing, Bronze LTB2 neck ring, SS 410 sleeve, squirrel case EF2 motor with a<br>complete VFD starter panel capable of operating the motor having a protection level of IP 40 or more with<br>integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules, with a power<br>control MCCB and line power contactor, and the starting current shall be 2.5 – 3.5 times the normal full load current<br>of motor with Ammeter, voltmeter and phase indicators, space heaters, floor monitory type and having an insulation<br>level of 100 V (the standard of starter is to be I.E.C 60947-4-2) control switches, capacitors, pressure gauge etc<br>satisfy the requirements and including the cost of internal wiring with suitable copper cable, valve( PN1.6), specials<br>etc and fixing the flow meter to pump sets (motor, capacity, type etc should be specified.) pipes and specials required<br>for the interconnection works with the existing pumping main suction and delivery part of pumps and provide the<br>electrical and mechanical installation as per the KSEB, and KSEI specification and standards (All items required for<br>the commissioning should be supplied and erected/fixed and initial and final approval obtained from KSEI and got<br>energized from KSEB). The pump and motor supplied are to be from Kerala Water Authority short listed<br>manufactures and should be in accordance with relevant IS Specification.one year extended warranty beyond the<br>original warrranty period of I Year. Total shall be limited to 2 Years) . (Rate vide proceedings no.<br>KWA/HO/SP/333/2011/Pump dtd. 20.12.2011 of the MD and latest any orders).(The acual head to be arrived by the contractor).
OD191190/2022-2023:Supply & fixing of flow meters and accessories of size 250mm-Supplying an Electromagnetic Flow meter confirming to protection level of IP-68 for Flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED /LCD display unit.The flow meter should have the housing (Flow sensor) to be made of ISS304/Carbon steel with anticorrossive protection and inside liner to be made up to Hard Rubber/neoprene all confirming to drinking water standads.The flow meter should be coupled with HART for data acquisition and transfer with provision for wirless transfer through GSM.The manufacturer should have the callibration standards as per ISO 17025 and the product shall have sufficient warranty provisions vide circular no KWA/HO/SP-4014/2012/Flowmeter and Soft starter dt 5/9/2012
OD191191/2022-2023:Supply & fixing of flow meters and accessories of size 450mm-Supplying an Electromagnetic Flow meter confirming to protection level of IP-68 for Flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED /LCD display unit.The flow meter should have the housing (Flow sensor) to be made of ISS304/Carbon steel with anticorrossive protection and inside liner to be made up to Hard Rubber/neoprene all confirming to drinking water standads.The flow meter should be coupled with HART for data acquisition and transfer with provision for wirless transfer through GSM.The manufacturer should have the callibration standards as per ISO 17025 and the product shall have sufficient warranty provisions vide circular no KWA/HO/SP-4014/2012/Flowmeter and Soft starter dt 5/9/2012
100.37.6.1:In situ fabrication of M.S. pipes of size 150mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.6.2:Fabricating M.S. flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.3:Cutting 150mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.4:Welding 150mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.5:Grinding cut and weld edges of 150mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.8.1:In situ fabrication of M.S. pipes of size 250mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.8.2:Fabricating M.S. flanges of diameter 250mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.8.3:Cutting 250mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.8.4:Welding 250mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.8.5:Grinding cut and weld edges of 250mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.1:In situ fabrication of M.S. pipes of size 450mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.12.2:Fabricating M.S. flanges of diameter 450mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.3:Cutting 450mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.4:Welding 450mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.5:Grinding cut and weld edges of 450mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.3:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
1D.Provision for alternate pumping arrangements at Ulloorpady to WTP at Nedungadapally while demolishing floor of existing puphouse
OD40140/2023-2024:Providing suitable alternate arrangements for the existing 3 nos 40 HP pumpsets and its piping arrangements at RWPH Ulloorpady for demolishing the existing pumphouse and floor of well cum pumphouse to construct new floor slab and pumphouse. This shall include dismantling the running pumpsets and its accessories from existing pumphouse floor and using the same or supplying, testing and erecting equivalant submersible pumpsets to supply water to the current destination, providing interconnection of newly erected pumpsets with existing raw water pumping main etc. This work shall also include to reinstall, trial run and commission the dismantled old pumpsets within the newly constructed RWPH as per directions of Engineer-in-Charge.
1E.Supply,Erection,testing and commissioning of the transformer(indoor type) at Raw water intake premises at Ullorpady.
OD40143/2023-2024:SUPPLY<ERECTION<TESTING AND COMMISSIONING OF TRANSFORMER - 750 KVA 11KV/433 V, 50 Hz, cast resin type transformer confirming to IS 11171 suitable for operation on 3 phase AC supply. 50Hz AN cooled INDOOR type copper wound distribution transformer with 11 KV VCB Panel with HT metering,Tripping coil,clossing coil rated 24V DC,11 KV Resin Cast CT(-/5A,5P10,15VA) Dual core, 11 KV Resin Cast PT (11 KV /11V, 100 VA Class0.5),Instantaneous IDMT relay with microprocessor base 30/C 1EF relay,Master Trip Relay,Auxilary relay)....etc....Complete with all fittings as per IS: 2026 and Kerala Electrical Inspectorate standards .The winding shall be with copper and the vector group shall be DYN11. OFF circuit tap links with tapings on HV side from 5% to -5 % in steps of 2.5 % shall be provided. Class F level of insulation shall be maintained and the core shall be made from M4 grade CRGO. The reference ambient temperature shall be 50C and the transformer shall withstand a temperature rise of windings above ambient by 90C. The transformer should withstand the impulse voltage and power frequency voltage as stipulated in the relevant IS specifications. The type of installation is indoor and the transformer shall be naturally air cooled. The loss of the transformer shall be strictly as per ECBC norms.<br>(Accepted make of transformers - KEL/ Intrans/ Megavin)
2A. Construction of 12 MLD Water Treatment Plant
OD96171/2023-2024:Charges for preparation of Good For Construction (GFC) drawings (both structural & architectural) through an accredited Structural Engineer/Govt. Accredited Agency after conducting Soil Investigation at WTP & OHSR site. The charges include the vetting charges for M/s WASCON, submission of 3 set of minimum A3 size Drawings for vetting by WASCON, soft copy of drawing in AUTOCAD and including any other design consultation charges complete as per direction of Departmental Engineer - In - Charge of the work.
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.33.4:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth
2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
16.1:Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
OD191145/2022-2023::Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Hard rock (required blasting) 2 nd lift of 1.5m to 3m
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
OD191133/2022-2023:Extra for shuttering in circular work for Suspended floor & roof (20% of respective centering and shuttering items as per 5.9.14
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
OD35550/2023-2024:Supplying ,Conveying and fixing 600 mm dia CI man hole cover with frame (Heavy duty) weighing not less than 220 kg in position as per direction of engineer in charge.
OD191136/2022-2023:M H cover with frame (medium duty)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
6.3.1:Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks
6.2.2:Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
OD191146/2022-2023:Providing and fixing 304 stainless steel lamella plates and support structures for water.-treatment, Inclined Chanel support ,top cover,side support,weir for water out flow,SS 304 nuts and bolts, welding etc<br>settlers and side supporting cover are fabricated using high graded stainless steel SS 304 suitable for use in the<br>water and waste treatment plants to improve the quantity and quality of water production.with all required<br>accessories-(effective size of plate length-2.1m,width-1.2 m,thickness-0.7 mm.) as per the direction of departmental<br>officers.<br>304 stainless steel lamella plates and support structures for water treatment plant.
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
11.5:62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.
11.41.3:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm
13.50.1:Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
21.18:Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
18.73.5:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :300 mm dia Ductile Iron Double Flanged
18.73.7:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :400 mm dia Ductile Iron Double Flanged
100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.
100.98.463:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.
100.98.465:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 400mm.
100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
100.31.1.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class I.
100.31.1.9:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 400mm diameter, Class I.
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
100.55.1:Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications.
100.55.2:Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification.
100.55.3:Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification.
100.55.4:Supplying and stacking for measurement of filter sand having effective size 0.45 to 0.70 mm and uniformity coefficient 1.30 to 1.7, of specific gravity in the range of 2.55 - 2.65 and hard and clean, free from clay, dust and other impurities including cost of materials, labour charges and conveyance of materials up to 5 km and as per the directions of the department officers etc. complete and as per CPHEEO specification.
2G.Provision for Electrical items
OD82134/2023-2024:Supply, installation, testing, and commissioning of electrical all items in connection with WTP and recycling plants like wiring materials, , ,wiring with suitable quality wires with sufficient number of Light(36 w led tube lights evenly fitted as minimum Two numbers per 100 sqfeet), Fan(Minimum one number per 100 sq feet), Minimum three plug pints of light and one for Power per 100 sqfeet and other necessary switches and plug points of suitable ratings wherever necessary as per direction of departmental officers subject to the condition that minimum 1 fan , 2 led 36 w lights, 2 plug points, and one power plug in each room and as per design of WTP for the satisfactory completion of the work, Yard lighting works as directed by departmental officers, Providing and fixing all fixtures including Ceiling Fan, Exhaust Fan, Pedestal Fan, wall mounted Fan and LED Lights of good quality wherever necessary and all other electrical works , CCTV works for all the areas in the WTP & outside(8Nos 5Mp camera with all connected items one month back up ),supply and laying cables from main panel board to WTP with adequate sizes and connected components and in accordance with safety standards , Required structures, supply and installation of all protective equipments and all safety works and items as per the standards of Electrical Inspectorate, supply an installation of lightning arrester as per IS specification, all safety equipment etc complete as per latest IE rules as per directions of departmental officers and items approved by Kerala Electrical Inspectorate, Drawings for the electrical inspectorate.(All the work must be in accordance with Electrical Inspectorate standards.) and all other electrical works for the satisfactory completion of the same .All the other cable works related to Electrical works, Supply and works of required Earthing and all related mechanical works . All paper and allied works with necessary statutory fees at Electrical inspectorate and KSEB Limited for approval and to be got approved by Electrical Inspectorate and connection from KSEBL. All the approved diagrams and reciepts from KSEBL and Inspectorate in original must be submitted to plant in charge after successful commissioning of the electrical items
OD94942/2023-2024:Supply installation All type of testing, trial run and commissioning of solar on grid plant with advanced Mono Perc Half Cut Solar panels, Structures to mount panels, DC cables and connectors DC junction Box, Inverters . AC junction BoxLink,,solar meter with Box, AC cables, Link/CB, TPN Box, Net Meter with approval of KSEB approval and all other electrical and mechanical accessories complete as per the direction of departmental officers and in accordance with Inspectorate standards. All paperwork, statutory fees and allied works with the Electrical inspectorate and KSEB Limited for the approval and to be got approved by Electrical Inspectorate and KSEB Limited
2H.Mechanical and other components necessary for operation of the WTP
OD94900/2023-2024: Supply, installation, Testing, Trial run and commissioning of All Mechanical components of the Water Treatment Plant and recycling plant and pumphouse(Sump and OH if necessary ) including pumps, motor, (for recycling tank and back wash also as per design if necessary) ,Water level indicator for Backwash tank,sump,OH tank,Lightning arrestors valves filter bed arrangements, gantry cranes, crane for chlorine tonner, rolling shutters, grills, ladders, DI K9 Pipes used for Interconnecting components in connection with WTP and recycling plant (except Raw water and clear water pump sets), handrails, protection works, pipeline works between all components such as blower unit, recycling plant, backwash tank etc all work in the WTP.blower units-(Use all DIK9 pipe), bridges and racking mechanics, under drains system, lateral pipes for air and water etc chlorine tonner with lifting arrangements; and filled chlorine tonner from TCL(4Nos)with all statutory approval. , supply, providing testing and commissioning of chlorinator unit with chlorine mixing pump and all connecting accessories(capacity of chlorinator for 100% over load-pennwalt type backwash units all connected works for the satisfactory completion of works as per the direction of departmental officers.
2B.Supply ,Erection and commissioning of the Transformer(indoor type) at WTP site at Mulayamvely.
OD82126/2023-2024:TRANSFORMER - 750 KVA 11KV/433 V, 50 Hz, cast resin type transformer confirming to IS 11171 suitable for operation on 3 phase AC supply. 50Hz AN cooled indoor type copper wound distribution transformer with 11 KV VCB Panel with HT metering,Tripping coil,clossing coil rated 24V DC,11 KV Resin Cast CT(-/5A,5P10,15VA) Dual core, 11 KV Resin Cast PT (11 KV /11V, 100 VA Class0.5),Instantaneous IDMT relay with microprocessor base 30/C 1EF relay,Master Trip Relay,Auxilary relay)....etc....Complete with all fittings as per IS: 2026 and Kerala Electrical Inspectorate standards .The winding shall be with copper and the vector group shall be DYN11. OFF circuit tap links with tapings on HV side from 5% to -5 % in steps of 2.5 % shall be provided. Class F level of insulation shall be maintained and the core shall be made from M4 grade CRGO. The reference ambient temperature shall be 50C and the transformer shall withstand a temperature rise of windings above ambient by 90C. The transformer should withstand the impulse voltage and power frequency voltage as stipulated in the relevant IS specifications. The type of installation is indoor and the transformer shall be naturally air cooled. The loss of the transformer shall be strictly as per ECBC norms.<br>(Accepted make of transformers - KEL/ Intrans/ Megavin)
2C.Compound wall & gate at WTP
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
16.18.1:Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for serarately) :- Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire
OD34466/2023-2024:Providing structural steel work of MS Angle of size 50 x 50 x 6 mm excluding labour and fixing charges
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
2D.Sludge valve chamber
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2E.Provision for instruments of laboratory
OD191173/2022-2023:Providing equipments required for functioning of the laboratory as per NABL standards(Supplying Laboratory Equipments conforming to relevant standards: 1. Laboratory pH meter with combination electrode and temperature compensation 2. Spare combination electrode for the pH meter above 3. Laboratory turbid meter to cover the range 0.1 to 1000 NTU including six sample cells and standards (Hach 2100N or equivalent) 4. Supplying electronic weighing balance measuring up to 300 g for WQM lab 5. Lovibond type Nessleriser with integral comparator including six sample tubes (50 ml) and disc for colour (0 to 70 Hazen units) 6. Comparator (Lovibond type) with twenty sample cells for analysis by DPD method, Autoclave, Water still, incubator, 180L capacity fridge, Common balance, discs for the range 0.1 to 1.0 mg/l and 0.1 to 4.0 mg/l residual chlorine 7. Hydrometers calibrated in specific gravity units with the range 1.000 to 1.200 for measuring lime slurry of concentration at 50 g/l - 3 8. Jar tests apparatus of the 4 jar unit type with adjustable speed control, illumination and timer including 10 No. 1 litre jars 9. Plastic sample bottles with screw caps of capacity 500 m 10. Plastic sample bottles with screw caps of capacity 1000 ml 11. Plastic buckets of capacity 10 litres 12. Beakers, Pyrex, low form with spout (10 No. capacity 100 ml., capacity 250 ml. and 5 No. capacity 1000 ml) 13. Wash bottles capacity 600 ml 14. Filter Papers (Whatmann) 15 cm diameter (10 No. boxes No. 1 Grade and 10 No. boxes No. 42 Grade) 15. Funnels, plain glass, conical, 75 mm diameter 16. Beakers, low form with spout; (5 No. 100 ml; 5 No. 250 ml; 5 No.600 ml; 4 No. 1000 ml; 2 No. 2000 ml) 17. Burette, schellbach, Class B, with interchangeable PTFE key (2 No. 50 ml) 18. Retort stand base, stainless steel, 210 x 130 x 8 mm; with threaded retort rod, 750 x 12.5 mm. 19. Retort stand boss and clamp 20. Measuring cylinders, polypropylene with spout (5 No. 25 ml., 5 No. 50 ml., 5 No. 100 ml. and 2 No. 1000 ml.) 21. Volumetric flasks BS 1792 Class B type, with polystop (5 No. 100 ml., 5 No. 250 ml., 5 No. 500 ml. and 5 No. 1000 ml.) 22. Erlenmeyer flask, DIN 12387 (5 No 200 ml) 23. Pipettes, straight sided BS 700, Class B, graduated to deliver fast flow (10 No. 1 ml., 10 No. 2 ml., 10 No. 5 ml. and 10 No. 10 ml.) 24. Pipettes, bulb, Class B, BS 1583 (2 No. 10 ml; 2 No. 25 ml.) 25. Pipette fillers 26. Nessler tubes (20 pairs 50 ml. and 5 pairs 100 ml.) 27. Racks for Nessler tubes (5 No. 50 ml. and 2 No. 100 ml.) Aluminium standard solution, Ammonia 35% solution, DPD tablets No 1 (comparator), DPD tablets No 3 (comparator),Hexamine ,Hydrochloric acid, Hydroxyl ammonium chloride, Indicator solution, DH 4.5 , Phenanthroline hydrochloride ,Pyrocatechol violet, Sulphuric acid,CONVOL –Autoclave, Water still, Incubator, Chemical Balance, etc. and other necessary equipments and accessories for setting up the water quality testing lab, all equipments and reagents as per NABL standards)
2J.Landscaping, Drainage works in WTP premises.
OD41035/2023-2024:Land development , landscaping and cement concrete road formation,gardening,grass pitching bushes and flower plants etc as per the direction of departmental officers.
2K.Road development works within WTP premises & RWPH
3.5.2:Excavation in Soil with Dozer with lead upto 100 m <br> Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. <br> (i) For Grading I Material
4.9:Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
5.2.3a:Tack Coat <br>Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 <br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means :- Case - III : Type C <br> (II) Bitumen (S-65)
2L.Operation and maintenance of the 12 MLD WTP &other connected components for three year .
OD82096/2023-2024:Supply of liquid chlorine filled in Tonner Cylinders (or as per condition)
OD82095/2023-2024:Supply and delivery of Alum (or as per condition)
OD82111/2023-2024:Supply and delivery of Hydrated lime as per specification at dosage(or as per condition)
OD82098/2023-2024:Cost for safety equipment such as helmets, safety shoes, jackets, safety belts, self containing breathing apparatus, refilling of fire extinguisher, safety masks, first aid kits,Tools and Plants required for the day to day operation of the Plant and Equipment etc complete.as per the direction of departmental officers..(all costs towards labour, spares, consumables, chemicals, repairs and renewals shall be on to the account of the contractor)- Two years
OD82099/2023-2024:Labour and material (all costs towards labour, spares, consumables, chemicals, repairs and renewals shall be on to the account of the contractor) cost for replacement of any parts and spares in the electrical,mechanical , ,laboratory equipment,plumping items,furniture items,landscaping items,valves. hand rails, gate, all components in the 12 MLD WTP .building and connected structures during maintenance period ,If any equipment/machinery/tools,All components connected with the 12 MLD WTP etc ( If anything found to be defective either due to manufacture or due to unsatisfactory maintenance, the same should be replaced by the contractor at his cost).
OD82110/2023-2024:Labour and material (all costs towards labour, spares, consumables, chemicals, repairs and renewals shall be on to the account of the contractor)cost for maintaining inside area of WTP compound such as roads , Landscaping area, gardens,water lines , electrical items,Cost of manure for gardening, hire charges for gardening tools , diesel operated lawn mover, including cost of diesel etc as per the direction of departmental officers
OD82109/2023-2024:Labour and material (all costs towards labour, spares, consumables, chemicals, repairs and renewals shall be on to the account of the contractor)Charges for Periodical Maintenance, Repairs of aerator,raw water Chanel,clear water channels ,flash mixer,clarifiers, filter bed building .chemical room building , lamella Clarifiers, leading Channels and other all units in the 12 MLD WTP and connected structures,compound wall, including door, windows,ventilators, hand rails ,lamella plate,( all components in the civil strutcher ) etc complete to the satisfaction of the KWA Engineer in-charge( If any found to be defective either due to manufacture or due to unsatisfactory maintenance, the same should be replaced by the contractor at his cost.).Sump,Back wash tank-minimum once in 3 months or( as instructed by KWA engineer).sludge lagoon ,recycling unit -minimum once in 4 months or( as instructed by KWA engineer). all other items should need daily cleaning or ( as instructed by KWA engineer).
OD95045/2023-2024:Operator
OD95043/2023-2024:Shift Assistant
OD95044/2023-2024:sweeper-part time
3A.Cost of Materials (pipe and specials) for the Raw water pumping main
100.98.122:Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia.
18.73.8:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :450 mm dia Ductile Iron Double Flanged
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
100.98.494:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 100mm.
100.98.497:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 200mm.
100.98.502:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 450mm.
3B.Working charges-Raw water pumping main
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
100.15.8:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 450mm diameter Ductile Iron Double Flanged pipes.
18.70.8:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:450 mm dia pipes
18.83.10:Labour for cutting C.I. pipe with steel saw.450 mm diameter C.I. pipe
100.35.8:Testing 450mm DI/CI pipeline with potable water to the required test pressure. 450 mm dia Observed Data derived from item no.1027 of PHED DATA
18.30.10:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe
100.31.1.10:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 450mm diameter, Class I.
100.31.2.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class II.
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
100.37.12.1:In situ fabrication of M.S. pipes of size 450mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.12.2:Fabricating M.S. flanges of diameter 450mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.3:Cutting 450mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.4:Welding 450mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.5:Grinding cut and weld edges of 450mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
3C.Valve chambers & Anchor blocks for Raw water Pumping main
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD96057/2023-2024:Supplying and fixing C.I man hole cover with frame for manholes:560 mm diameter ( heavy duty) the weight to be not less than 208 kg.
3D.Road Restoration for RWPM-PWD road
3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
4.2.A.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-III -For lower sub-base - Mix in Place Method
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.2.b:Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.
5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)
5.6.2.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - II (13.2 mm Nominal Size)
5.7.1:Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.09 mm (Type-A) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade, and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to the required level and grade.
55.23:Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc. complete.
8.13:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, the thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform, and free from streaks and holes.
8.15:Supplying and installation of delineator (Roadway indicators) posts 80- 100cm high above ground level, pained black, and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorized panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)
8.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3<br> Road Markers/Road Stud with Lense Reflector :-
12.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
12.8.A:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications<br> PCC Grade M15 ( Without formwork) <br>
3E-Road Restoration for RWPM-Panchayath Road
3.6:Excavation in Marshy Soil <br> Excavation for roadway in marshy soil with hydraulic excavator 0.9 cum bucket capacity including cutting and loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 m, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.6.
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. <br> (i) For Grading I Material
4.9:Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity <br> Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a:Tack Coat <br>Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 <br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means :- Case - III : Type C <br> (II) Bitumen (S-65)
JOSEPH JOHN
Bidder Name
JOSEPH JOHN
SHAJI P C
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid