Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 CrAccepted-AOC 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹16.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹17.2 CrRejected-Finance | ₹17.2 Cr | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹17.8 CrRejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹17.8 Cr | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹18.4 CrRejected-Finance | ₹18.4 Cr | L4 | Rejected-Finance Rejected being L4 |
Tender Value
₹16 Cr
EMD Value
₹11.3 L
Closing Date
7 Aug 2020, 6:00 pmClosed
CENEKOCHI
KATARIBAGH NAVAL BASE KOCHI
CONSTRUCTION OF MAINTENANCE AND SERVICE BAY FOR YARD UTILITY MACHINERY AT NSRY KOCHI
2020_MES_350451_1
890938
Open Tender
Civil Works
660 days
Kochi
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (P )KOCHI
₹11.3 L
Yes
25 Sept 2020
6 Jun 2020
10 Aug 2020
6 Jun 2020
7 Aug 2020
24 Jul 2020
8 Jun 2020 - 13 Jun 2020
Amount
LIST OF WORKS
Schedule A Part I( to Part XIII)
Total amount of Sch 'A' Part-I (Buildings & Structures)
Total amount of Sch 'A' Part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' Part-III (Internal Electric Supply)
Total amount of Sch 'A' Part-IV (Internal Water Supply)
Total amount of Sch 'A' Part-V (Road/Path/Hardstanding)
Total amount of Sch 'A' Part-VI(Sewage Disposal)
Total amount of Sch 'A' part-VII (Area Drainage)
Total amount of Sch 'A' part-VIII (Compound Wall/Fencing and gate)
Total amount of Sch 'A' part-IX (External Electric Supply)
Total amount of Sch 'A' part-X (Externall Water Supply)
Total amount of Sch 'A' part-XI ( Lightning Protection)
Total amount of Sch 'A' part-XII(Fire Fighting & Fire alarm Systems)
Total amount of Sch 'A' part-XIII(Vehicle Washing Ramp)
Total amount of Sch 'A' part-XIV(Demolition & Dismantling B/R /E/M)
Sch 'A' Part- XV(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete(RMC) M30 grade in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items
RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drg. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 12mm dia as in stirups for pile caps and gared beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
All as per item No 25 above but 5mm dia and over up to & including 12 mm dia as in helicals of pile reinforcement including rings and necessary tack welding to pile reinforcement at all points of contacts.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 500mm dia cast in situ pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia cast in situ pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Conducting standard penetration test all as per IS-2131 at levels and locations as directed for 500mm dia cast in situ bored piles all as specified and as directed by the Engineer -in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Excavation over areas n exc 1.5m deep in soft / soil complete all as specified and directed.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m deposited whereever dircted at a level not exc 1.5 m above starting point .
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
Material and labour for Cutting the trees of girth exc 30cm and not exc 100cm and stacking of serviceable material and removing of unserviceable material to a distance not exc 50m and clearing the site, the cutting of tree trunk to be cut in maximum length complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 36 herein before but exc 101cm and not exc 150cm.
All as per Item No 36 herein before but exc 151cm and not exc 200cm.
All as per Item No 36 herein before but exc 250cm and not exc 300cm.
INTERNAL ELECTRIFICATION: Taking down DB SPN with all accessories all as specified and as directed by the Engineer-in-Charge.
Taking down electric meter and depositing to MES stores with proper record all as specified and as directed by the Engineer-in-Charge.
Taking down Service connection including pipe, GI wire and Insulators all as specified and as directed by the Engineer-in-Charge.
Supply and fix Ceiling fan 1200mm sweep copper wound having service value not less than 4.5, including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sqmm from ceiling rose/ connector to fan all as specified and as directed by the Engineer-in-Charge. (Make :CG/USHA/ORIENT)
Supply and fix Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having ISI marked and including complete all as specified and as directed by the engineer-in-Charge.Make: CG/USHA/Almonard
Supply and fix LED Tube light 1X20 Watt universal battern type with and including connecting 3 core 1Sqmm PVC insulated multistranded copper conductor color of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed by the engineer-in-Charge. Make:- (a) Fitting: Crompton Cat Part No IGP161LT8-16 or equivalent make of Wipro/Philips. (b) Lamp: Crompton Cat Part No LTT8-20 or equivalent make of Wipro/Philips.
Supply and fix Sleek LED light 1X10 Watt 2 feet with and including connecting 3 core 1Sqmm PVC insulated multistranded copper conductor color of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed by the engineer-in-Charge. Make: (a) Fitting: Crompton Cat Part No LDL-10-CDL or equivalent make of Wipro/Philips. (b) Lamp: Crompton Cat Part No LT8-8-562-2 or equivalent make of Wipro/Philips.
Supply and fix Surface full LED 2' x 2' fitting 36Watt including connecting 3 core 1Sqmm PVC insulated multistranded copper conductor color of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed by the Engineer-in-Charge. Make:- Crompton Cat Part No LCTLSNE-36-F0-CDL or equivalent make of Wipro/Philips.
Supply and fix Sleek LED mirror light 1X07 Watt 1 feet with and including connecting 3 core 1Sqmm PVC insulated multistranded copper conductor color of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed by the engineer-in-Charge. Make:-FITTING WITH LAMP: Crompton Cat Part No LCL-07-CDL or equivalent make of Wipro/Philips.
Supply and fix LED bulb 9 Watt suitable for and incuding B22 angle holder/batten holder copmplete all as specified and directed at site. Make: Philips or equivalent in CG/Wipro
Supply and fix Security light fitting pressure die cast alluminium housing heat resistance toughened glass having IP 65 protection of 35Watt complete including fixing with GI Bracket made of 32mm dia GI pipe including fixing clamps etc complete all as specified and as directed by the Engineer-in-Charge. (Make : Philips Model No BRP050LED 036CWR1MFPCS1PSU GR or equivalent make of CG/Philips).
Supply and fix LED bulk head fittings with IP-65 protection suitable for surface and wall mounting applications complete all as specified and as directed by the Engineer-in-Charge. Make: Philips Model No WT140W LED 7S CW PSU S1 PC or equivalent make of Crompton/Wipro
Supply and fix Four pole MCCB 125Amps 25KA ,Icu=Ics=100% with adjustable TM range all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix Four pole MCCB 100Amps 25KA ,Icu=Ics=100% with adjustable TM range all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix Four pole MCCB 63Amps 25KA ,Icu=Ics=100% with adjustable TM range all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix MCB TP 32Amps 10KA 240volts with charaterestic curve "C" curve all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix MCB SP 6-32Amps 10KA 240volts with charaterestic curve "C" curve all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix MCB SPN 6-32Amps 10KA 240volts with charaterestic curve "C" curve all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix MCB SP 40-63Amps 10KA 240volts with charaterestic curve "C" curve all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix VTPN MCCB DB 4 way, 415Volt , double door, IP-43 protection suitable for MCCB 4 pole upto 160Amps as incomer complete with isolated neutral bar, insulated bus bar assembly all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix VTPN MCCB DB 6 way, 415Volt , double door, IP-43 protection suitable for MCCB 4 pole upto 160Amps as incomer complete with isolated neutral bar, insulated bus bar assembly all as specified and as directed by the Engineer-in-Charge. Make : Legrand/Schinder/L & T
Supply and fix CMRI certified LED flame proof tube light fixture 2 x 20 watt IP 65 including 02 Nos 20 Watt LED tube light complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix flame proof weather proof exhaust fan of 380 mm sweep single phase complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix flame proof flexible metalic conduit ¾" and 500 mm long suitable for terminal boxes/ light fittings/ Fans etc all as specified and as directed by the Engineer-in-Charge.
Supply and fix Inner and outer modular cover plate all as specified and as directed by the Engineer-in-Charge.
Supply and fix Tele socket 1 module all as specified and as directed by the Engineer-in-Charge.
COMPOUND WALL/FENCING AND GATE:-Supply and fix 610mm dia super Razor punched barb tape (SRPBT) Aluminium Base helix concertina coil with and including necessary G.I fixing clips for securing complete all as specified and as directed with following specifications :- (a) Dia of coil(unstretched) - 610mm (b) No of circles- 51 turns per coil (c) Weight of each coil with hessain cloth - 8.5 kgs(+ 0.50 kg) coverage per coil- 8 RM (d) Central core wire :- Made from 2.5 mm dia GI -HTSS wire as per IS 4454 - Galvanised as per IS -2629 (e) Razor punched strip : Razor Punched tape is CONSEC-ZAL Steel comprising of aluminium base with zinc alloy @ 150 gms/M2 conforming to ASTM A-792/A-792M with additional primer treatment/ of epoxy/polyurethane & final paint top coat of caulifieid green shade (BSL 139) By hot dipping process.
ROAD WORK:-Material and labour for WMM in two layers 150mm thick(75mm each)watered, rolled and consolidated to required gradient and camber to form a true surface all as specified and as directed by the engineer-in-Charge.
SEWAGE DISPOSAL:-Material and labour for DECPE pipe 150mm Inner dia and 172.50Outer dia laid in concrete bed complete all as specified and as directed by the engineer-in-Charge.
Internal Water Supply :- Supply and fix Stop cock 25mm bore with wall flange ceramic disc cartridge with plain knob complete of make Jaquar cat part No CQT-24081 or equivalent in Zolotto/Prayag all as specified and as directed by the Engineer-in-Charge.
Supply and fix Stop cock angular 15mm bore with wall flange complete of make Jaquar Cat part No CQT-23059 or equivalent in Zolotto/Prayag all as specified and as directed by the Engineer-in-Charge.
Supply and fix Bip tap with wall flange complete of make Jaquar Cat part No CQT-23047 or equivalent in Zolotto/Prayag all as specified and as directed by the Engineer-in-Charge.
Supply and fix Health faucet/ hand shower with 8 mm dia, wall hook and easy flexible tube in crome finish1.5m long with nuts complete of make Jaquar cat part No ALD573 and SHA 571 or equivalent in Zolotto/Prayag all as specified and as directed by the Engineer-in-Charge.
EXTERNAL WATER SUPPLY:- Cutting the existing DI water supply pipe line 150mm dia and inserting and including Tee 150x150x100 mm all as specified and as directed by the Engineer-in-Charge.
Supply, Install, test and commissioning Pump set mono block type, 36metre head, 2LPS(Approx 3HP) electric driven 3 Phase 415V including PCC foundation, platform, MS base frame with fixing nuts bolts, adequate length of suitable suction pipe of CPVC with jointing arrangement complete all as specified and as directed by the Engineer-in-Charge.
Supply and Install DOL starter, panel type 3HP with inbuilt overload protection relay, Ammeter, voltmeter, LED Indicators, SPP etc complete all as specified and as directed by the Engineer-in-Charge.
Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nos steel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
EXTERNAL ELECTRIC SUPPLY:- Supply and lay LT UG cable XLPE insulated galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volt grade with aluminium conductor cable of size 3.5 core 400Sqmm and making cable connection with cable glands, lugs, nut, bolts, washers etc complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 77 herein before but 3.5 core 300 Sqmm.
All as per Item No 77 herein before but 3.5 core 240Sqmm
All as per Item No 77 herein before but 3.5 core 70 Sqmm
All as per Item No 77 herein before but 3.5 core 50 Sqmm
All as per Item No 77 herein before but 4core 16 Sqmm
All as per Item No 77 herein before but 4 core 10 Sqmm[Highmast light]
All as per Item No 77 herein before but 2 core 6 Sqmm
Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120Sqmm complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120Sqmm complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 86 herein before but outdoor termination.
Supply and fix rubber mat of size 1 mtr x 2 mtr x 2.5 mm suitable for HT 11 KV all as specified and as directed by the Engineer-in-Charge.
Supply, install, testing and commissioning of LT Panel board out door type IP-54 protection made out of CRCA sheet 3 mm thick, powder coated painting welded on suitable structural steel frame duly fixed on PCC platform 1:3:6 type C-1 with locking arrangement and comprising of following accessories :- (a) ACB 800 Amp 4 pole 50 KA with micro processor release electric draw out type - 01 Nos (Incomer) (b) MCCB 400 Amp 35 KA 4 pole adjustable TM range- 01 No (c) MCCB 320 Amp 35 KA 4 pole adjustable TM range - 02 No (c) MCCB 250 Amp 35 KA 4 pole adjustable TM range- 01 No (d) MCCB 125 Amp 25 KA 4 pole adjustable TM range- 01 No (e) MCCB 40 Amp DP 10 KA adjustable TM range - 02 Nos (f) MCCB 16 Amp 4 Pole fixed TM range - 01 No (f) Aluminium bus bar 1000 Amp TPN - 01 set (g) Digital volt meter 0-500 volt with SS - 01 No (h) Digital amp meter with SS 0-600 Amp - 01 No (j) Indicating lamp RYB - 01 No (Set of three) (k) CT of suitable ratio 600/5 Amp - Set of 03 Nos
Supply, Install, testing and commissioning of LT Panel board indoor type IP-52 protection made out of CRCA sheet 2 mm thick, powder coated painting welded on suitable structural steel frame duly fixed on PCC platform 1:3:6 type C-1 with locking arrangement and comprising of following accessories :- (a) MCCB 400 Amp 35 KA 4 pole adjustable TM range - 01 No (b) MCCB 4 pole 125 Amp 25 KA adjustable TM range- 04 Nos (c) Aluminium bus bar 600 Amp TPN - 01 set (d) Digital volt meter 0-500 volt with SS - 01 No (e) Digital amp meter with SS 0-400 Amp - 01 No (f) Indicating lamp RYB - 01 No (Set of three) (g) CT of suitable ratio 400/5 Amp - Set of 03 Nos (h)MCCB 100A 25KA 4 pole -03Nos
Supply, install, testing and commissioning of LT Panel board indoor type IP-52 protection made out of CRCA sheet 2 mm thick, powder coated painting welded on suitable structural steel frame duly fixed on PCC platform 1:3:6 type C-1 with locking arrangement and comprising of following accessories :- (a) MCCB 320 Amp 35 KA 4 pole - 01 No (b) MCCB 4 pole 100 Amp 25 KA adjustable TM range- 06 Nos (c) Aluminium bus bar 500 Amp TPN - 01 set (d) Digital volt meter 0-500 volt with SS - 01 No (e) Digital amp meter with SS 0-400 Amp - 01 No (f) Indicating lamp RYB - 01 No (Set of three) (g) CT of suitable ratio 400/5 Amp - Set of 03 Nos
Supply , Install, testing and commissioning of LT Panel board indoor type IP-52 protection made out of CRCA sheet 2 mm thick, powder coated painting welded on suitable structural steel frame duly fixed on PCC platform 1:3:6 type C-1 with locking arrangement and comprising of following accessories :- (a) MCCB 125 Amp 25 KA 4 pole adjustable TM range- 01 No (b) MCCB 63 Amp 16 KA 4 pole adjustable TM range - 03 Nos (c) MCCB 32 Amp 16 KA 4 pole adjustable TM range - 02 Nos (d) Aluminium bus bar 200 Amp TPN - 01 set (d) Digital volt meter 0-500 volt with SS - 01 No (e) Digital amp meter with SS 0-200 Amp - 01 No (f) Indicating lamp RYB - 01 No (Set of three) (g) CT of suitable ratio 200/5 Amp - Set of 03 Nos
Supply and fix LED flood light 200 Watt exclusive innovative die-cast aluminium non integral IP-66 protection suitable for highmast application including suitable control gear box complete all as specified and as directed (Model No JETAVALOURFLS200WLED757MODSYMLTG of Havells)
Material and Labour for high galvanised mast light suitable for 9 lantern symmetrically fitted alongwith their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, fully assembly, aviation obstruction light incl inverter & battery (with 12 Hrs backup) suitably fixed and wired upto aviation light only, lightning arrestor spike including RCC foundation as per height 15 mtr complete all as specified and as directed.Note:- Contractor shall submit design of foundation which shall be got approved by Accepting Officer before execution.
Supply and fix Sheet steel enclossure made out of 3 mm thick CRCA sheet outdoor type powded coated including locking arrangement shall be fixed on angle iron 40 x 40 x 6 mm duly coated with red oxide primer and two coat of synthetic enamel paint fixed on PCC platform suitable for fixing of MCB DB SPN 4 way complete all as specifired and directed by Engr-In-Charge.
Supply and Insatallation of outdoor type Ring Main unit 11KV 63A, 20KA, Motor operated, compacted both side extensible non drawnout type +CVV+(one No load Break switch as incomer and two Nos fixed type motor operated Vacum Circuit Breaker as outgoing SAFEPLUS compact gas insulated Ring Main unit all live parts enclosed in a robotically welded stainless steel tank of IP 67 class of protection including battery charger complete all as specifired and directed by Engr-In-Charge.
Supply and fix MCB TPN 16 Amps 415 volt complete all as specified and as directed by the engineer-in-Charge.
Material and labour for pressed steel terminal boxes of size 100mmx100mmx60mm with 3mm thick plastic laminated sheet cover complete all as specified and as directed by the engineer-in-Charge.
AIR CONDITIONING:-Supply and install in wall split AC units inverter type, indoor/ outdoor complete with cordless remote controle unit and with in built ioniser for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR all as specified and directed.
Supply and install in wall split AC units inverter type, indoor/ outdoor complete with cordless remote controle unit and with in built ioniser for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2 TR complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variatiuon between 170V to 250V with output voltage stabilized at 230 V with accuracy of +- 2.5 % and of capacity 03 KVA all as specified and as directed by the Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230 V with accuracy of +- 2.5 % and of capacity 04 KVA all as specified and as directed by the Engineer-in-Charge.
FIRE FIGHTING AND FIRE ALARM:-Supply and fix synthetic reinforced rubber cotton synthetic fibre circular oven jacketed fire delivery hose 63 mm dia treated against rot/moistex having 30 Kg/cm2 working pressure bearing IS 636 - 68 type A 15 Mtrs length with male and female coupling conforming to IS 903 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix reinforced rubber cotton synthetic fibre circular woven jacketted fire delivery hose 63 mm dia treated against rot/moistex having 38 KG/Cm2 working pressure bearing IS-636 type `A' 30 mtrs length with male and female coupling conforming to IS-903 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix automatic gunmetal air release valve 50mm dia including 50mm gun metal stop valve complete all as specified and as directed by the Engineer-in-Charge.
Supply, laying and testing PVC insulated, PVC sheathed FRLS cable galvanised steel strip or wire armoured electric control cables (heavy duty) with stranded copper conductor of size 1.5 Sqmm 2 core 1100 volts grade with ISI marked, red in colour for fire alrm system and laid on wall/roof/trench etc with necessary fixing accessories complete all as specified and as directed by the Engineer-in-Charge.
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 02 hours complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay LT UG cable XLPE insulated galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volt grade with aluminium conductor cable of size 3.5 core 120Sqmm and making cable connection with cable glands, lugs, nut, bolts, washers etc complete all as specified and as directed. (Fire fighting)
Material and labour for 5 core 4.0Sqmm copper conductor cable PVC insulated, sheathed multistranded ISI marked 1100 Volts grade drawn in and including PVC rigid concealed conduit medium grade of dia not less than 25 mm dia with conduit accessories ( For Terrace pump) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix DOL starter for 7.5 HP motor 3 phase 415 volts 50 Hz with inbuilt accessories suitable for automatic operation of fire fighting pump (Terrace pump) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCCB 32 Amp 16 kA, 3 Pole including sheet metal enclosure fabricated out of CRCA sheet 2 mm thick with locking arrangement and space for fixing DOL starter 7.5 HP motor and including internal wiring to DOL starter and necessary relays for automatic operation of terrace pump completeall as specified and as directed by the Engineer-in-Charge.
Supply, fabricate, install, test & commissioning indoor LT panel board made out of CRCA sheet 2 mm thick, dust and vermin proof, duly powder coated cubical type, front and rear opening with hinged doors and mechanical locking arrangement, cable entry/exit holes at bottom and mounting channels, PCC foundation and platform as per site requirement complete with aluminium busbar on insulators, busbar duly laminated with PVC sleeves with colour coding. The panel should be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system, internal control wiring should be pre-wired with suitable size of copper cables, all meters duly connected with following accessories and marking of all incoming/outgoing feeders for identification by printastic letters complete all as specified and directed and comprising of following:-
LIFT : Design , Supply , install,testing and commissioning goods lift 1000 Kg, speed 0.5 m/sec with single speed motor, 415 V, 3 phase AC 50 Hz supply conforming to IS 14665 and as amended, suitable to serve G+2 upper floors with AC variable voltage and variable frequency drive (VVVF) drive complete with all standard accessories, simplex automatic and manual dual control operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue Devices (ARD) system 3D infra red sensor in full height of doors and built in announcing system without handset ( three Nos, one each in car, machine room and near ground floor landing door) complete all as specified and as directed.
Design , Supply , install,testing and commissioning goods lift 2000 Kg, speed 0.5 m/sec with single speed motor, 415 V, 3 phase AC 50 Hz supply conforming to IS 14665 and as amended, suitable to serve G+2 upper floors with AC variable voltage and variable frequency drive (VVVF) drive complete with all standard accessories, symplex automatic and manual dual control operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue Devices (ARD) system 3D infra red sensor in full height of doors and built in announcing system without handset ( three Nos, one each in car, machine room and near ground floor landing door) complete all as specified and as directed
Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core complete all as specified and as directed by the engineer-in-Charge.
Supply and fix 4 pole MCCB 32 Amp, 50 Hz, 415 volt breaking capacity 16 KA including suitable enclosure made up of CRCA sheet 2mm thick complete all as specified and as directed.
WATER COOLER:-Supply, install and commissioning of electronic water purifier system (single phase) with ozone technology of capacity 125 Ltr/ hr with normal, hot and cold water outlet with inbuilt RO+UV technology with all accessories and making water supply and electric connection complete all as specified and as directed by the Engineer-in-Charge. Make: Ozone water purifier system / Best doctor water purifier / Kent
Supply and fix Voltage stabilizer for automatic operation with low and high voltage protection relay, single phase, naturally air cooled indoor type and designed for input variation between 170V to 250V without put voltage stablizer at 230V with accuracy with in +/- 2.5% and capacity 2.0 KVA all as specified and as directed by the Engineer-in-Charge.
ARBORICULTURE:-Supply only approved earth for planting of grass all as specified and as directed by the Engineer-in-Charge.Note:- Surface excavation, removal and moorum filling shall be measured under Schedul 'A Part II
Supply only River sand all as specified and as directed by the Engineer-in-Charge.
Spreading,levelling,watering and well ramming approved earth and sand in required proportion as directed for planting of grass in layers not exceeding 25 cm thick including supply and mixing of ½ kg/sqm of cow dung,0.25kg/sqm of bone meal and 15 grams/sqm of insecticides all as specified and as directed by the Engineer-in-Charge.
Material and labour for Excavation of pits of size 30 x 30 x 30 cm size in loose soil and filling the pit with mixture of approved earth and river sand in the proprotion of 1 :3 by Volume , mixed with 2 kg of cowdung powder , 100 gms of bone meal and 10 gms of insecticide [ Furadan] and removal of excavated soil to a distance n. exc 50 m all as specified and as directed by the Engineer-in-Charge.
Supply and planting redpalm sapling having 45 cm height all as specified and as directed by the Engineer-in-Charge.
Supply and planting flower palnts sapling having 10 cm minimum height all as specified and as directed by the Engineer-in-Charge.
Supply and planting Phylanthus sapling having 15 to 30 cm height all as specified and as directed by the Engineer-in-Charge.
Supply and planting colour flower palnts sapling having 15 to 30 cm height all as specified and as directed by the Engineer-in-Charge.
Supply and planting song of India flower palnts sapling having 15 to 30 cm height all as specified and as directed by the Engineer-in-Charge.
Supply and planting Dracena flower palnts sapling having 15 to 30 cm height all as specified and as directed by the Engineer-in-Charge.
Supply and planting mexican grass including providing manure all as specified and as directed by the Engineer-in-Charge.
COMPREHENSIVE MAINTENANCE OF LIFT:- Comprehensive maintenance of goods lift through OEM for 1000 Kg (01 No) & 2000 Kg (01 No) capacity lift- (ie total 02 Lifts ) to serve ground plus two upper floors all as mentioned in relevent items of this BOQ complete all as specified and as directed for First year after expiry of defects liability period.
All as per Item No.132 here in before but for Second year after expiry of defects liability period.
All as per Item No.132 here in before but for Third year after expiry of defects liability period.
VARAHA INFRA LIMITED
UBC Engineers Pvt Ltd
PPJOHN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid