Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.1 L+₹21,731.15 (2.45%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹9.2 L+₹29,122.27 (3.28%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹9.2 L+₹29,140.73 (3.28%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹9.4 L+₹56,524.86 (6.36%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹13.1 L
EMD Value
₹32,760
Closing Date
30 Apr 2025, 2:00 pmClosed
EXECUTIVE ENGINEER
P.H DIVISION KOTTARAKKARA
Deposit Work - 2024-25- Punalur Muncipality - Pipe line extension at various wards in Punalur muncipality.-Pipe line extension at Komalamkunnu, Maniyar, Ikkarakkonam wards
2025_KWA_761344_1
WRD/KWA-CE(SR)/TR/5669/16
Open Tender
Civil Works - Water Works
Item Rate
90 days
Punalur Muncipality
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹32,760
14 Jul 2025
23 Apr 2025
2 May 2025
23 Apr 2025
30 Apr 2025
23 Apr 2025
Amount
WORKING CHARGES
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
OD251801/2024-2025:Taking connection from newly laid 160/140/110 /90/75 to 160mm to 40mm mm or nearest size.PVC/GI /AC distribution<br>main and existing branch line using suitable equal Tee(suitable class),reducer, CID/CIR and reducers including cost of<br>materials labor charge etc complet
OD251831/2024-2025:Shifting existing water connection to the newly laid pipe including cost of materials and labour charges as per direction of dept. officers.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
100.98.235:Supply of PVC Pipe, 10kg/cm2, 75mm Dia.
18.12.7:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
MUHZIN N (BID ID -2205135)
Reji Mathew (BID ID -2203918)
VARGHESE CHACKO (BID ID -2203973)
GIRIDAS K S (BID ID -2201951)
C G BAHULEYAN (BID ID -2204922)
SANTHOSHKUMAR.S (BID ID -2204791)
Bidder Name
C G BAHULEYAN
SANTHOSHKUMAR.S
VARGHESE CHACKO
GIRIDAS K S
Reji Mathew
Sreehari R
MUHZIN N
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1238582.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .