| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-Finance NONE | ₹14.9 L | L1 | Accepted-Finance Selected |
| 2 | L2₹16.6 LAccepted-Finance 50 3 S F ARJUN NAGAR NEW DELHI 110029 | SOUTH | DELHI | 110029 | ₹16.6 L | L2 | Accepted-Finance Selected |
| 3 | L3₹16.6 LAccepted-Finance 0 DOGRA CHOWK JEWEL JAMMU JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | ₹16.6 L | L3 | Accepted-Finance Selected |
| 4 | L4₹18.5 LAccepted-Finance 15 119 DAKHINPURI NEW DELHI 110062 | SOUTH | DELHI | 110062 | ₹18.5 L | L4 | Accepted-Finance Selected |
| 5 | Not Admitted-Fee/PreQual/Technical 2ND FLOOR SHAHEEN BAGH F 207 ABUL FAZAL ENCLAVE II JAMIA NAGAR OKHLA SOUTH DELHI 110025 | SOUTH EAST | DELHI | 110025 | - | - | Not Admitted-Fee/PreQual/Technical Others-Affidavit not as per NIT |
Tender Value
₹23.9 L
EMD Value
₹47,838
Closing Date
24 Jan 2026, 3:00 pmClosed
The Executive Engineer (E)
The Executive Engineer (E) EMD South East, Thyagraj Stadium, New Delhi-110003
(SH - Electrical Up gradation of offices at SER-21, AC-42 VREC Jangpura, etc. and Installation of UPS and Poles at PWD EMSD-III office Campus.)
2026_PWD_285160_1
122/EE(E)/EMD South East/PWD/2025-26(Recall)
Open Tender
Miscellaneous Services
90 days
At Site
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹47,838
29 Jan 2026
19 Jan 2026
24 Jan 2026
19 Jan 2026
24 Jan 2026
19 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
a) Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
a) Group C
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.
a) 3 x 1.5 sq.mm
b) 6 x 1.5 sq.mm
c) 3 x 4 sq.mm
d) 6 x 4 sq.mm
e) 3 x 6 sq.mm
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
a) 1 or 2 Module (75mmX75mm)
b) 3 Module (100mmX75mm)
c) 6 Module (200mmX75mm)
d) 8 Module (125mmX125mm)
e) 12 Module (200mmX150mm)
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 amp switch
b) 3 pin 5/6 amp socket outlet
c) 15/16 amp switch
d) 6 pin 15/16 amp socket outlet
e) Bell Push
f) 25A modular SP MCB "C" curve
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
a) 3 Module
b) 6 Module
c) 8 Module
d) 12 Module
Supplying and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box i/c connections but excluding modular plate etc as reqd.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing following way, single pole and neutral, sheet, steel, MCB distributions board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 12way Double door
b) 6way Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 6 way (4 + 18), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release an terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
a) 100 Amp, 16 KA, TPMCCB
b) 125 A, 16 KA,TPMCCB
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
a) 18- 22 watt
b) 36 watt
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
a) 18 watt
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
a) 36watt
Supplying and fixing of suitable H-shape angle iron suitable for fixing/mounting LED flood light on terrace etc as reqd.
Supplying and fixing of pole box (200mmx140mmx95/100 deep) made out hot moulded SMC with 01no 16amp 3pole connector, din channel and 01 No. 6 Amp SPMCB complete with connections earthing testing etc as reqd.
Supplying. Installation, testing and commissioning of 300 mm sweep metallic heavy duty 900 rpm exhaust fan suitable for operation on 230V, 50 Hz single phase AC supply complete with louvers / shutters in the existing opening including making the hole to suit the size of the above fan making good the damage and connections etc. as reqd.
Supplying & Intallation of fresh air fan 200 mm sweep with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
Supplying & Intallation of fresh air fan 250 mm sweep with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying & Laying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured cable on surface as reqd.
a) 3 x 10 Sqmm
Supplying Installation Testing and commissioning of water cooler with 150/150ltr storage capacity suitable for operation on 230Volts 10%, 50Hz, single phase AC supply with high efficiency compressor faster cooling, ergonomically desgined for greater safety and operational convenience low power consumption, superior quality grooved copper tubes in heat exchager, ISI marked blue fins on condensor coil, stainless steel body for longer product lift, stainless steel tank food grade water piping float valve and other components which come in contact with drinking water, water inlet, hosepipe, overflow pipe to be provided with water cooler packing adjustable pedestal made of high non corrosive strong material minimum two number faucets etc complete as reqd.
Supplying Installation Testing and Commissioning of 50LPH RO System design to deliver upto 50ltrs of purified water per hour through a 6 stage purification process. its membrane should have a pore size of 0.0001 micron size which prevents the passage the micro organisms and total dissolved salts making the water lighter test natural and save to drink. the RO system should have 04nos of 75 GPD membrane, system operating voltage 48volt DC suitable for operating temperature 5 degree to 45 degree, suitable for 230volt 50Hz AC supply i/c making plubming connection and interconnection with pipe, pipe accessories complete etc as reqd.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C,
Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
Lifting the defective submersible pump set along with GI pipe upto 5 HP from existing bore well with the help of tripode chain and pulley block etc as reqd
Supplying and lowering of 3HP/2.2KW borewell submersible pump set having 40mm dia discharge pipe line and deliver discharge 100-22LPM at head of 36-198mtrs or equivalent specifications suitable for operation on three phase 415volt 50Hz AC supply in the existing borewell complete alongwith safety wire etc as reqd.
Supplying and fixing of upto 3HP submersible pump DOL starter suitable for three phase 415 volt 50Hz AC supply with enclosure relay range 6-10 amp having single phase preventer with complete testing and commissioning etc as reqd
Supply, Erection, Testing & Commissioning of 4 Meter long Decorative Street Light Pole should be Made out of Galvanized mild steel tube having bottom part of the pole 1000mm x 140mm x 4mm and upper part should be 3000mm x 75mm x 3mm made out of mild steel galvanized tubes the bottom and middle part of the poles are to be fitted with cast aluminium and the pole should have a service window at the bottom contaning 25amp heavy duty connector terminal and 6amp single pole MCB wiring upto light fixture from junction box/ connector plate using 3core 1.5sqmm PVC insulated flexible copper wire. Pole should be mounted 4nos of bolts at the bottom and Providing and making suitable size cement concrete foundation with 1:2:4 (1 Cement:2Coarse sand:4 graded stone aggregate of 20 mm dia nominal size) with steel reinforcement as per OEM design. The Item includes P/F excavation of earth of suitable size as per approved drawing as required with positioning of foundation bolts- 04 nos, j-type foundation bolt with nuts, washer including 01 nos template of 3 mm thick of suitable size with 4 nos suitable size of dia holes, to match with PCD of pole base plate as reqd with 1 nos. 50 mm dia HDPE pipe of 6 Kg. pressure duly bend of 1.0 Mtr./ required length etc. as reqd. The item also includes for work, water curing, plastering etc complete as req. as per approved drawing. (Drawings of poles and its RCC structure shall be got approved before erection.)
Supplying and fixing 40 W LED post top lantern having IP66 rating on the existing pole of 65 mm diameter suitable for single phase 230V, 50Hz electric supply complete with testing and commissioning etc. as required.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
a) bituminous road
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying & Laying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured cable in the existing RCC/ HUME/ METAL pipe as required.
a) 3x10 Sqmm
supplying and drawing of 3core 1.5sqmm size PVC insulated PVC sheathed copper conductor (flexible) muiltcore cable in the existing upto 8mtr poles and bracket from cable termination connection to the fitting i/c providing suitable copper lugs connections etc as reqd.
Supply, installation, testing and commissioning of panel board with dust & vermin proof IP-42 protection compartmentalized indoor type cubical panel board made out of not less than 1.6 mm thick CRCA sheet, the sheet steel member shall be stiffened by angle iron framed. The depth of cubical panel shall not be less than 300 mm and suitable sizes earth strip shall be provided around the cubical panel. The cubical panel shall be of suitable size to incorporate following switchgear i/c connections, powder coating of approved colour and shades complete etc. as reqd. Panel should be fixed on CC foundation/ angle iron frame work. 200A, 25KA, 4P incomer MCCB-1 No. 100A 4P 25KA outgoing MCCB-01 No. 125A 4P 25KA outgoind MCCB-01 No. 25/32A DP 10KA MCB- 3 Nos CT's 200/5A class-1.0 10VA-03 Nos Digital MFM -1 No R,Y,B Phase Indicating Lamp-03Nos 350A TPN, Aluminium Bus Bar Extended Rotating Handle & Spreader -03 Nos
Supplying & fixing 400mm sweep wall mounted cabin fan with speed regulator oscilatting type i/c testing & commsisioning suitable for 230volt 50Hz AC supply etc as reqd.
Credit for dismantle materials
Assorted : Ceiling
Assorted : Exhaust Fans
Assorted : Fresh Air Fan/wall fan
Assorted : Switch/socket/regulator (Piano/Modular)
Assorted : SP /DP MCB upto 63 A
Assorted : SP/TPDB MCB DB
Assorted : MCCB
Assorted : copper Wire with insulation
Assorted : GI Box with modular plate/phenolic sheet
Assorted : LED batten/Downlighter/fl. Fitting
Assorted : 2x2 fitting
Assorted : cable
Assorted : inveter
Assorted : Battery 100AH
Assorted : LED Post Top Fitting
Assorted : Pump
Assorted : Starter
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
nit.pdf
Tender Documents • 2.55 MB
BOQ_377223.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid