GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF FIRE ALARM SYSTEM WITH SPRINKLER SYSTEM AND REPLACEMENT OF COOLING APPLIANCES AT HQ SWAC, COMN FLT AND VARIOUS SECTORS OF GANDHINAGAR UNDER GE (AF) CHILODA
2026_MES_796752_1
8523/26-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GANDHINAGAR
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹56,880
Yes
31 Oct 2026
31 Oct 2026
23 Nov 2026
31 Oct 2026
21 Nov 2026
15 Nov 2026
31 Oct 2026 - 14 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing Addressable Fire alarm control panel, comprising of Multi loop data card, battery 12V, 10Ah, LCD/LED display panel, buzzers with software programs sutable to detect smoke detectror, manual call point, hooter, repeater etc, including testing by OEM complete all as specified and as directed by Engineer-in-Charge.
Make :- Honeywell or eqvivalent make as approved by GE. | 1 | Each | - | - |
| 2 | Supply and Fix addressable multi sensor smoke detector complete including complete all as specified and as directed by Engineer-in-Charge.
Make :- Honeywell or eqvivalent make as approved by GE. | 11 | Each | - | - |
| 3 | Supply and Fix addressable manual Call point (MCP) with box and accessories complete all as specified and as directed by Engineer-in-Charge.
Make :- Honeywell or eqvivalent make as approved by GE. | 2 | Each | - | - |
| 4 | Supply and Fix addressable sounder suitable for addresssable fire alarm system complete all as specified and as directed by Engineer-in-Charge.
Make :- Honeywell or eqvivalent make as approved by GE. | 2 | Each | - | - |
| 5 | Supply and Fix metal junction box for detector an hooter including all accessories for surface mounting complete all as specified and as directed by Engineer-in-Charge.
Make :- Standard or eqvivalent make as approved by GE. | 13 | Each | - | - |
| 6 | Supply and laying in replacement of Mild Steel Stove enameled black conduit alongwith the accessories such as tees, bends, elbows, bell mouth ends and all fixing accessories such as couplers, locknuts, saddles, pipe hook etc. on surface/recess including painting, in case of recessed conduit, cutting the wall and making good the same for of recessed conduit of size 25 mm dia. complete all as specified and as directed by Engineer-in-Charge. | 120 | RM | - | - |
| 7 | Supply, draw, connecting, testing and commissioning in replacement of 2 core 1.5 sq mm stranded copper conductor, PVC insulated PVC sheathed FRLS, flexible armoured cable laid on ceiling/wall clamped with aluminium clamps/ drawn in ERW pipe ccomplete all as specified and as directed by Engineer-in-Charge.
Note :-
(i) The cables are to be drawn through the false ceilings, laid in floors, fixed to walls as per the site requirements.
(ii) The conduits are to be measured and paid seperately under relevent item. | 700 | RM | - | - |
| 8 | Material & Labour 25 mm dia UPVC pipe with all fittings complete fixed to walls or laid in floors /trenches including testing complete as in repairs complete all as specified and as directed by Engineer-in-Charge.
Make :- finolex or eqvivalent as approved by GE | 550 | RM | - | - |
| 9 | Supply and Fix of addressable control module complete with metal junction box and mounting acccesories acomplete all as specified and as directed by Engineer-in-Charge.
Make :- Honeywell or eqvivalent make as approved by GE. | 2 | Each | - | - |
| 10 | Supply, Installation,commissioning and testing of addressable single loop fire alarm repeater panel with primary supply voltage 230volts AC (max upto 260 volts) and secondary supply upto voltage 30 DC, the panel should be competable in operating temperature upto 50 degree centigrate and operating humidity level less than 95 % (non condensed) with graphic touch LCD display complete including dismantling the old panel complete all as specified and as directed by Engineer-in-Charge.
Note :-
(i) The panel should be as per the OEM recommendations.
(ii) Site inspection for maintenance of Fire alarm system is necessary before quoting the tender.
Make :- Honeywell or eqvivalent make as approved by GE. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.37 MB
BOQ_893675.xls
BOQ • 1.69 MB
Tenderdocument8523.pdf
Tender Documents • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .