Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.6 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹66.2 L+₹1.6 L (2.46%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹67.0 L+₹2.4 L (3.74%)Rejected-Finance H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹69.9 L+₹5.3 L (8.20%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹70.0 L+₹5.4 L (8.38%)Rejected-Finance H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | L5 | Rejected-Finance L5 |
Tender Value
₹68.9 L
EMD Value
₹1.4 L
Closing Date
7 Feb 2023, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Elect. Division HPPWD Palampur
Construction of City Convention Centre cum Parking at Dharamshala in District Kangra (H.P.) (SH- Providing E.I. therein)
2023_PWD_67619_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
1095 days
Dharamshala in Distt. Kangra
Please refer Tender documents.
14 documents required · 14 mandatory
₹2,000
₹1.4 L
20 Jun 2026
28 Jan 2023
7 Feb 2023
28 Jan 2023
7 Feb 2023
28 Jan 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Make: KEI/Plaza/SCI/Anchor/ Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius) /L&T(Entice).
Group C.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Make: Make: KEI/Plaza/SCI/Anchor/ Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius) /L&T(Entice).
Group C.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. Make: SCI/KEI/Plaza/Anchor.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make: KEI/SCI/Plaza/Anchor.
3 x 2.5 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (Make: Sidharth/BEC)
25 mm. dia
Supplying and fixing of following sizes of PVC conduit of medium class with 1.4 mm thickness along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- (Make: BEC Plast/Anchor)
25 mm. dia
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
2 Module (75mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
T.V. Socket outlet modular type
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make: Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Make: Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. Make: Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase, 230 volts complete as required:-
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel board of suitable size cubical, weather, dust and vermin proof fabricated out of CRCA sheet steel suitable size thickness complete MCCB panel board should be manufactured and supplied by CPRI approved and ISO 9001 certified OEM. The busbar system should be duly type tested at NABL lab for short time with stand current of 1 second, it should be suitable for wall or floor mounting with double door option, panel board enclosure should be robust construction and corrosion resistance, powder coated with seven tank process with locking arrangement, fixed on suitable size foundation 60 cm above the ground level by providing angle iron of 50x50x6 mm welded on all four corners embedded in PCC 1:2:4 using 20mm graded stone aggregate up to 30 cm including electrical connections with lugs and glands complete with installation, testing and commissioning etc. including the cost of copper alloy bus bar, digital type Ammeter,Voltmeter, modules and three phase indicating lamps as required complete in all respects. The panel should be approved/tested from the CPRI lab and should be confirmed to IS:64139. (Make: Power System & Controls/ EVA or equivalent CPRI approved).
MATERIAL:
600 Amp rated copper bus bar with colour code TPN mounted on epoxy insulators - 01 set (set of 04 bus bars)
Digital Multifunction meter 0-400 Amp with suitable CTs - 01 set
LED indicating lamp (set of three) - 01 set
Internal wiring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified.
Earthing terminals and cable glands.
Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
SWITCHGEAR
OUTGOING :
Onload change over switch 160 A 4P, Indicating lamp LED type RYB 6 Nos, Control SP MCB 6A 6Nos, MCCB 160A 4P 36 KA with O/L & S/C protection 2 No., Spreader link 160A 4P 2 Nos., MCCB 400A 4P 36 KA TMR with O/L & S/C Protection 2 No., Spreder link 400 A 4P 2 Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc,
Makes for MCCB : Schneider/L&T/ABB .
Supplying, Installation, Testing and Commissioning of indoor s/door, L.T. Sub Panel board of suitable size cubical, weather, dust and vermin proof fabricated out of CRCA sheet steel suitable size thickness complete MCCB panel board should be manufactured and supplied by CPRI approved and ISO 9001 certified OEM. The busbar system should be duly type tested at NABL lab for short time with stand current of 1 second, it should be suitable for wall or floor mounting with double door option, panel board enclosure should be robust construction and corrosion resistance, powder coated with seven tank process with locking arrangement, fixed on suitable size foundation 60 cm above the ground level by providing angle iron of 50x50x6 mm welded on all four corners embedded in PCC 1:2:4 using 20mm graded stone aggregate up to 30 cm including electrical connections with lugs and glands complete with installation, testing and commissioning etc. including the cost of copper alloy bus bar, digital type Ammeter,Voltmeter, modules and three phase indicating lamps as required complete in all respects. The panel should be approved/tested from the CPRI lab and should be confirmed to IS:64139. (Make: Power System & Controls/ EVA or equivalent CPRI approved).
MATERIAL:
200 Amp rated copper bus bar with colour code TPN mounted on epoxy insulators - 01 set (set of 04 bus bars)
Digital Multifunction meter 0-400 Amp with suitable CTs - 01 set
LED indicating lamp (set of three) - 01 set
Internal wiring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified.
Earthing terminals and cable glands.
Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
SWITCHGEAR
OUTGOING :
MCCB 63A 4P 25 KA with O/L & S/C protection 2 No., Spreader link 63A 4P 2 Nos., MCCB 40A 4P 25 KA TMR with O/L & S/C Protection 4 Nos., Spreder link 40 A 4P 4 Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc,
Makes for MCCB : Schneider/L&T/ABB .
Supplying, Installation, Testing and Commissioning of indoor s/door, L.T. Sub Panel board of suitable size cubical, weather, dust and vermin proof fabricated out of CRCA sheet steel suitable size thickness complete MCCB panel board should be manufactured and supplied by CPRI approved and ISO 9001 certified OEM. The busbar system should be duly type tested at NABL lab for short time with stand current of 1 second, it should be suitable for wall or floor mounting with double door option, panel board enclosure should be robust construction and corrosion resistance, powder coated with seven tank process with locking arrangement, fixed on suitable size foundation 60 cm above the ground level by providing angle iron of 50x50x6 mm welded on all four corners embedded in PCC 1:2:4 using 20mm graded stone aggregate up to 30 cm including electrical connections with lugs and glands complete with installation, testing and commissioning etc. including the cost of copper alloy bus bar, digital type Ammeter,Voltmeter, modules and three phase indicating lamps as required complete in all respects. The panel should be approved/tested from the CPRI lab and should be confirmed to IS:64139. (Make: Power System & Controls/ EVA or equivalent CPRI approved).
MATERIAL:
400 Amp rated copper bus bar with colour code TPN mounted on epoxy insulators - 01 set (set of 04 bus bars)
Digital Multifunction meter 0-400 Amp with suitable CTs - 01 set
LED indicating lamp (set of three) - 01 set
Internal wiring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified.
Earthing terminals and cable glands.
Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
SWITCHGEAR
OUTGOING :
MCCB 200A 4P 36 KA with O/L & S/C protection 2 No., Spreader link 200A 4P 2 Nos., MCCB 100A 4P 25 KA TMR with O/L & S/C Protection 4 Nos., Spreder link 100 A 4P 4 Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc,
Makes for MCCB : Schneider/L&T/ABB .
Supplying, installing, testing, commissioning and electrically connected Factory (CPRI approved) made LT panel board of approved size as recommended by IS & CPRI norms, indoor type, floorwise sub panel wall/floor mounted 1100 Volts, made out of CRCA sheet 1.6 mm thick, fully compartmentalised, with IP-54 (certificate not older than 2 years), for 415 volts, 3 phase, 4 wire AC supply, complete all as specified including provision of following accessory/ components housed in it :-
100 Amp rated copper bus bar with colour code TPN mounted on epoxy insulators - 01 set (set of 04 bus bars).
LED indicating lamp (set of three) - 01 set
Internal wiring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified.
Earthing terminals and cable glands.
Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
MAIN INCOMER :- MCCB 40/63/100 A 4P 25 kA with O/L & S/C Protection 5 Nos., Spreader Link 40/63A/100 4P 5 Nos, Indicating lamp LED type RYB 15 Nos, Control MCB SP 15 Nos.
G.F. MCCB 100A 1 No for Heating Load, MCCB 40A 1No for Light Load
F.F. MCCB 100A 1 No for Heating Load, MCCB 40A 1No for Light Load
S.F. MCCB 40A 1No for Light Load
OUTGOING :
Space for 8 way DB and N/Link & E/Bar 5 Nos
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc, For Light load Incomer 40/63 A
Makes for MCCB : Schneider/L&T/ABB .
Supplying, installing, testing, commissioning and electrically connected Factory (CPRI approved) made LT panel board of approved size as recommended by IS & CPRI norms, indoor type, floorwise sub panel wall/floor mounted 1100 Volts, made out of CRCA sheet 1.6 mm thick, fully compartmentalised, with IP-54 (certificate not older than 2 years), for 415 volts, 3 phase, 4 wire AC supply, complete all as specified including provision of following accessory/ components housed in it :-
200 Amp rated copper bus bar with colour code TPN mounted on epoxy insulators - 01 set (set of 04 bus bars)
LED indicating lamp (set of three) - 01 set
Internal wiring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified.
Earthing terminals and cable glands.
Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
MAIN INCOMER :- MCCB 200 A 4P 36 kA with O/L & S/C Protecrtion 1 Nos., Spreader Link 200 4P 1 No, Indicating lamp LED type RYB 3 Nos, Control MCB SP 3 Nos.
OUTGOING :
Space for 8 way DB and N/Link & E/Bar 5 Nos
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Makes for MCCB : Schneider/L&T/ABB .
Supplying and fixing extra down rod of 60 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 6 Amp (Make:- Anchor/ Schneider/ Legrand/L&T)
Single pole 16 Amp (Make:- Anchor/ Schneider/ Legrand/L&T)
Single pole 25/32 Amp (Make:- Anchor/ Schneider/ Legrand/L&T)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. (Make:- Anchor/ Schneider/ Legrand/L&T)
63 Amps. (Make:- Anchor/ Schneider/ Legrand/L&T)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. (Make:- Anchor/ Schneider/ Legrand/L&T)
63 Amps. (Make:- Anchor/ Schneider/ Legrand/L&T)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
Double door-6 way (Make:- Anchor/ Schneider/ Legrand/L&T)
Double door-8 way (Make:- Anchor/ Schneider/ Legrand/L&T)
Double door-12 way (Make:- Anchor/ Schneider/ Legrand/L&T)
Double door-16 way (Make:- Anchor/ Schneider/ Legrand/L&T)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run).
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run).
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- (Make:- SCI/KEI/ Plaza/Havells).
Armoured cable 25 sq. mm (3.5 core)
Armoured cable 50 sq. mm (3.5 core)
Armoured cable 70 sq. mm (3.5 core)
Armoured cable 300 sq. mm (3.5 core)
Armoured cable 400 sq. mm (3.5 core)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- (Make:- KEI/ SCI/Plaza/Havells)
Armoured cable 400 sq. mm (3.5 core)
Providing, Installation, testing and commissioning of ceiling fan ISI mark with step type two module electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1200 mm sweep (Make: Usha, Model: Technix Plus)/ Bajaj (Model: Sabse Tezz Kassels)/ Crompton (Model: WWHE).
Ceiling Fan 1400 mm sweep (Make: Bajaj Model:Speedster/ Crompton Model:WWHE) /Anchor (Model: XL).
Providing, Installation, testing and commissioning of wall fan of following size by means of suitable rag-bolt/ nuts, connections, testing and commissioning etc. as required complete in all respects as required.
Wall Fan, 400 mm sweep (Makes:- Bajaj Esteem 400)/Usha (Model:Air Flo)/ Anchor (Model: Fancy)/Crompton (Model:High Flo).
Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.
Exhaust Fan, Light duty, (Domestic) 300 mm sweep (Make: Usha, Model: Aeroclean LD)/Bajaj (Model: Freshee)/Anchor (Model: Anmol)/Crompton(Model: Drift air Plus) .
Exhaust Fan, Heavy duty, (Domestic) 300 mm sweep (Make: Usha, Model: Aeroclean LD)/Bajaj (Model: Freshee)/Anchor (Model: Anmol)/Crompton(Model: Drift air Plus) .
Providing and fixing GI louvers/shutters complete with frame for exhaust fans of all sizes complete with fixing including making good the damages etc. as required complete in all respects.
Providing and fixing of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 with five years warranty.The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
Bulk Head Light LED 10 watt Makes:- Philips /Wipro/Trilux.
Providing and fixing LED Mirror Light of IP20 Led fixture 10 W+/- 1W with Surface Mounted 2 Feet with Polycarbonate diffuser with Extruded aluminium housing having minimum system lumen output 1000 lumens and system lumen efficacy of 100 lm/W with P.F.>0.95 with THD<20% ,CRI 80 .The LED with Useful life of 50000 Hrs at L70 with five years warranty. The LEDs used in the luminaire shall have CCT of ANSI Bin 6500 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LED Mirror Light 10 watt Makes:- Philips /Wipro/Trilux.
Providing and Fixing of IP20 LED fixture of following watt +/- 1 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 with five years warranty. The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LED Surface mounting round downlighter 12 watt Makes:- Philips /Wipro/Trilux.
LED Surface mounting round downlighter 18 watt Makes:- Philips /Wipro/Trilux.
Providing and Fixing of LED fixture 600mmX600mm 36 Watt +/- 1W Surface mounted fixture with HET Plastic diffuser with minimum system lumen efficacy of 100 lm/W with CRCA housing having P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70 with five years warranty. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LED Panel 2'x2' 36 watt Makes:- Philips /Wipro/Trilux.
Providing and Fixing of 1200 mm X 300 mm LED fixture 36 W +/- 1W Surface mounted fixture with HET Plastic diffuser with CRCA Powder Coated housing having minimum system lumen efficacy 100lm/W with P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70 with five years warranty. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V , 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LED Panel Light 36 watt 4'x1' Makes:- Philips /Wipro/Trilux.
Providing and Fixing of IP20 LED Surface mounted CRCA Powder Coated Box Type Channel with Pro LED Lamp Suitable for mounting 1 X 18 W LED Tube T8 type having minimum system efficacy of 100 lm/W, P.F.>0.95 with THD<10% ,CCT 6500 K,CRI 80,Surge Protection 2 Kv.The LED with Useful life of 50000 Hrs at L70 with five years warranty.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LED fixture 1x18 Watt Surface Mounted 4 Feet Box Type Channel with Pro LED Lamp Makes:- Philips /Wipro/Trilux.
Supplying and fixing of following sizes PVC pipes 4 KGF/CM along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- Make:- Finolex/ Diplast
75 mm dia.
90 mm dia.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- Makes: Racold/Bajaj/Havells
25 Liter capacity water heater (Cat-A)
Supplying and fixing modular 6 way bell indicator with buzzer, reset switch, name plate including the cost of surface mounting plastic gang box and cover plates with mounting frames suitable to operate on 230 volts A.C. supply complete with all accessories, connections, testing and commissioning etc. as required complete in all respect.Makes: Goldmedal or equivalent
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make: Schneider/ Legrand/L&T.
100 Amp 18KA
Providing and fixing Enclosure for MCCBs suitable for 3Pole & 4Pole MCCBs etc. as required. Make: Anchor/ Legrand/L&T.
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 4 pole MCCB incomer, 2 module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required.
Double door 2+12 way (MCCB+6+36) module.
Supplying and fixing of Electrical Panel Rubber insulation mat of suitable size and thickness upto 12.5mm with chequered holes/ solid sheet with insulation voltage resistance of 2kv/sqm etc. as required complete in all respects.
JAMWAL ELECTRICAL WORKS
SHARMA ELECTRICAL CO.
Malhotra Associates
Deepak Sood
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.20 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .