| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹28.9 L+₹1.0 L (3.64%)Rejected-AOC | L2 | Rejected-AOC DUE TO L2 | |
| 3 | L3₹29.5 L+₹1.6 L (5.84%)Rejected-AOC | L3 | Rejected-AOC DUE TO L3 | |
| 4 | L4₹30.9 L+₹3.0 L (10.7%)Rejected-AOC | L4 | Rejected-AOC DUE TO L4 | |
| 5 | L5₹30.9 L+₹3.1 L (11.0%)Rejected-AOC SHIVAJI NIWAS VILL CHIMBALHAR P O GEETA PEETH PALAMPUR HP 176061 | KANGRA | HIMACHAL PRADESH | 176061 | L5 | Rejected-AOC DUE TO L5 |
Tender Value
₹29.1 L
EMD Value
₹58,200
Closing Date
12 Mar 2021, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
SPECIAL REPAIR TO BLDG NO P 15 IN LSNS AREA UNDER GE KH YOL
2021_MES_421503_1
CWE/Y-124/2020-21
Open Tender
Civil Works
Works
180 days
YOL Cantt
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (KH) Yol
₹58,200
Yes
13 Apr 2021
12 Feb 2021
13 Mar 2021
12 Feb 2021
12 Mar 2021
27 Feb 2021
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of brick work or stonework or precast concrete articles and precast concrete block walling ,built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Taking down chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. .
Taking down shutter of any description exc 1 sqm but not exc 2 sqm each complete all as specified and directed.
Taking down steel water tubing 15 mm bore including all fitting and connections complete all as specified and directed.
Taking down steel water tubing 20 mm bore including all fitting and connections complete all as specified and directed..
Dismantling timber scantling as in fillets, rails, rafter etc under 40 sqcm in section framed work complete all as specified and directed.
Demolition of wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc all as specified.
Hard core of broken stone or boulders of gauge not exc 63 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed.
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in roof kerbs or mud stops, or in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating chamfered on edges including necessary formwork where required complete all as specified and directed.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed.
2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed
Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 160 of MES SSR 2010 Part-II.
35 mm thick 2nd class hard wood (Sal/Hollock)) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a) complete all as specified and directed.
35mm thick flush shutters, solid core construction with particle board core and plywood face panels commercial type on both sides including 6mm thick external teak wood lipping complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, Sheet No 1/1) specified and directed.
Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 No's for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Make : As per Appendix 'C'. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day.
Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars including cutting, drilling, welding etc confirming to Fe-290 Gde E-165 all as specified and directed.
300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Aluminium handles cast type anodized of size 150 mm complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 150 mm and fixed complete all as specified and directed.
Mild steel butt hinges of size 100 mm medium weight cold rolled complete all as specified and directed.
Galvanished mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanished wire staples complete all as specified and directed.
Sheet glass, 4 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
Steel clip-in false ceiling system with steel plain, perforated, beveled edged tile (600mmx600mm) manufactured out of 0.50 mm thick polyster coil coated galvanised steel having 180 grams zinc coating. Coil coated steel tile shall have 20 micron polyster coated finish on front side and back coat of 5 micron alkalys primer. Two sides of each tile shall be raised and piped and stopped to ensure positive engagement into the spring clip-in profile allowing for demounting of individual tiles. The rigid suspension system consists of rows of galvanized steel 0.50 mm thick clip-in profile of size 38mm x 20 mm and installed at 600 mm c/c spacing to support the tiles. Wall suspension angle, clip-in profiles shall be suspended and jointed fs of size 24 mm X 24 mmX 0.40mm thick are suspended from roof structure by GI ceiling brackets. wall suspension angles of size 24mmx24mm and 0.40mm thick are suspended from the roof structure by GI ceiling brackets. Wall suspension angle are made of coil coated steel matching the colour of tile. They are jointed to the clip in-profile system by hold on clamps. The tiles/ planks are held in place by pressure clips as per manufacuters instructions for spacing. In the flexible system the hanger and butterfly clip replace the suspension angle including necessary scaffolding all as per manufacuters specifications/instructions and specified and directd by Engr-in-charge/GE.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.60mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.60mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified
Rolled mild steel work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to grade Fe 410 -W (Gde-E- 250) quality-B, complete all as specified and as directed.
Rolled mild steel work as in main and cross beams, hips and jack rafter, purlins where connected to common rafters and running rails and guides for sliding doors ,fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in floor finish, surface finished even and fair to receive top finish complete all as specified and directed.
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Glazed ceramic coloured tiles of size 450 mm x 350 mm x 7 mm/350 mm x 250 mm x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
Vitrified ceramic tiles (light shade) 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Vitrified ceramic tiles (light shade) 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm as directed by EIC, as in vertical surfaces , set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. .
20mm thick Granite work (table rubbed and polished) incills and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator over and including 75mm thick PCC M-10 (Nominal Mix) type C-2, using 40mm graded crushed stone aggregate complete all as specified and directed.
Rendering cement plaster 20mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces, mixed with water proofing admixture as per manufacturer's instructions, trowelled to even and smooth finish without using extra cement complete all as specified. (Note:- WPC will be measured and paid separately)
Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Supply only liquid water proofing admixture.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
Preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old wooden surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of wooden surfaces of any description and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer over and including 3mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Preparation of old surfaces of wall by washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of oil bound distemper complete all as specified and directed.
One coat of white wash including preparation of old surfaces of walls complete all as specified and directed.
One coat of white wash including preparation of old surfaces of ceiling complete all as specified and directed.
Preparation of new plastered surfaces or un plastered, previously undecorated wall surfaces and applying two coats of cement base paint, complete all as specified and directed.
Preparation of plastered or un-plastered, old surfaces of walls and applying one coat of cement base paint, complete all as specified and directed.
G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.
Taking down of existing un-serviceable roof treatment materials including removing plaster, PCC padding etc complete from roof carefully by cutting chiseling, cleaning the surface by scraping brooming brushing etc and removing the rubbish from site complete all as directed.
50 mm thick plain cement concrete 1:2:4 (nominal mix) type B-1 (using 20 mm graded crushed stone aggregate) as in roof top padding over and including brushing with neat cement slurry with 3.0 kg of cement per sqm, mixed with water proofing admixture as per manufacturer's instructions, complete all as specified and directed. (Note:- WPC will be measured and paid separately)
15mm thick (average) screed bed/ plaster in cement mortar 1:3 in order to maintain proper slope and base over existing roof surface for laying of APP based polymeric membrane, mixed with integral water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete, all as specified and directed. (Note:- WPC and polymeric membrane shall be measured and paid separately).
Water profing treatement over terrace using SHALIURETHANE- BTD OF STP MAKE OR EQUIVALENT as approved by GE, high solid content single component water based liquid applied elastomeric water proofing membrene as ASTMC 836 and ASTMD 6083, thickness of the memberane shall be 1.5mm, having solid content of more than 80% elongation of 500+(-)50% , laid over reinforcing layer on non woven geo-textile mesh of 40/50, 50gms, including applying self primer coat by diluting with 1:1 ratio @ 0.2 kg per sqm and surface preparation including cleaning of existing treatement complete all as specified and directed.
Sink with drainage board (glossy) made of high grade stainless steel 1 mm thick with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x510 mm and bowl size 600mmx450mm x 225mm complete all as specified and directed.
Stainless steel curtain rod, 25 mm bore, powder coated with all fittings i.e. wall bracket, bracket screws, stope and rollers, fixed in repairs all as specified.
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges fixed in repairs with and including chromium plated brass brackets, brass screws complete all as specified
Chromium plated soap dish, fixed in repair complete all as specified.
15mm bore, chromium plated, self cleaning water jet (Health Fuset) for EWC, fixed in repair complete all as specified.
15mm bore, chromium plated, wall mixer with telephoneic shower complete, fixed in repair complete all as specified.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
Chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union complete all as specified
Chromium plated toilet paper holder fixed with brass screw in repair complete all as specified.
Waste coupling of PTMT of 32mm bore of discharge pipe (half or full threaded) (Minimum weight 45gms) complete all as specified.
Wash basins, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, complete all as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx 'C'
Stop valves/ angle valve/ concealed valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure , screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified. Type of valve approved by the GE.
Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore and fixed in repairs complete all as specified and directed.
Health faucet (ABS body with 1m long easy flex in chrome finish tube and wall hook complete with accessories, fixed in repair, complete all as specified.
PVC connections 15 mm size with PTMT nuts of length 600mm fixed in repair complete all as specified and directed.
Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs all as specified. Make: Cat Part No. 2008 for EWC, 2308 for seat cover, 2201/B for internal fittings of 'Cera' or equivalent in makes mentioned in Appx 'C'
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, in repairs, all as specified. Make: Cat Part No. 2602 of Cera or equivalent in makes mentioned in Appx 'C'.
600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers.
PVC cabinet of size 350 x 450mm with shelf assembly mirror mounted as shutter complete all as directed.
110mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to tranches or in floor or walls ,fixed in repair omplete all as specified and directed.
75mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to tranches or in floor or walls, fixed in repair complete all as specified and directed.
110 mm dia PVC(SWR) bend, any radius complete all as specified and directed.
75 mm dia PVC(SWR) bend, any radius complete all as specified and directed.
75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Disconnecting existing tank any type of capacity exc 250 litre and not exc 500 litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surface complete all as specified and directed.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC conduit not less than 20mm dia, medium grade with IS 9537 (Part-III) 1983 marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.
All as per serial item No '91' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '91' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No '91' above, but for one light point controlled by two way switch all as specified and directed.
All as per serial item No. '91' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch piano flush type, single pole, two way, 5 Amps, all as specified and directed.
Switch socket combination two in one, 5 amps flush type, all as specified.
Switch socket combination two in one, 3 Pin 5 amps and 15 amps, flush type, all as specified.
Bell push, flush type, 5 amp all as specified.
Bell, AC,ding dong, 230 volts, single pole all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings , all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
LED lamps, 10 watts all as specified and directed. Make:- CAT Part No LHLDERUEML8X010 of make "Havells" or equivalent in makes mentioned in Appendix "C".
Flush type, step fan speed controller suitable for 1200/ 1400 mm sweep ceiling fan complete all as specified and directed.
Taking down electric meter of any size and capacity, refixing the same after rewiring , complete all as directed.
Taking down ceiling/ exhaust fan of 1200/ 1400/ 250/ 300 mm sweep from fan hook dismentling blade opening of motor cleaning stator rotor, cleaning of all parts, greasing, oiling of bush & bearing, reassembling including replaecement of unserviceable parts complete, refixing, reconnecting with 3 core copper cable of size 23/0.0076 from ceiling rose to ceiling fan and testing on completion, complete all as specified.
Removal of existing burnt winding of ceiling fan, cleaning the slots thoroughly with suitable cleaning agent, applying slot insulation and rewinding with new super enameled insulated 30 to 38 SWG copper wire of appropriate size including all winding, insulating material and impregnation of insulating varnish of any make, type, model, applying air drying the winding thoroughly complete, all as specified and directed.
Disconnecting/ taking down electric water heater any type/ capacity 25 litre, removing and cleaning the dust properly, painting with two coats of synthetic enamel paint of same colour using spray gun after preparing surface for painting including refixing duly grouting nuts, bolts, washers and making plumbing connections and making the conections with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light and testing complete all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 12 way, double door, 240 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
Renewal of sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
E-lite LED Triyca batten, colour changing LED batten with options of 3000K, 4000K & 6500K all in one fixture, 20 Watts complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Havell's Cat Part No. LHEXBYPNIN1W020 or equivalent in makes mentioned in Appx 'C'.
E-lite LED Triyca batten, colour changing LED batten with options of 3000K, 4000K & 6500K all in one fixture, 10 Watts complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Havell's Cat Part No. LHEXBYPNIN1W010 or equivalent in makes mentioned in Appx 'C'.
Roadway lighting luminaire, LED street light 35 watts, IP-66 having aluminium housing with toughned glass on 9.00 metres poles/ walls. LED should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick heat transfer of heat to heat sink. This ensure the LED assembly free from dust/ moisture/ water entry (IP-66). The operating voltage should be from 90V to 300V with under voltage and over voltage protection. The luminaire should be connected aluminium pvc insulated wire 2 sqmm as required at site and connecting the same to the cable with the help of the connector all as specfied and directed. Make:- Havell's Cat Part No ENDURACITYLITEPLAT PLUSSL35W LED757SASYBOPC or equivalent in makes mentioned in Appendix 'C'. Note:- Contractor shall provide following certificates:- (i) IP-66 as per IS/ IEC60529-2001 with test certificate. (ii) THD˂15% with test certificate. (iii) Warranty upto two years.
MCB TPN 40 to 63 Amps, 415 Volts, 10 KA all as specified.
MCB SPN 40 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 40 Amp, 240 Volts, 10 KA all as specified.
Excavation in trenches for pipes, cables and manholes in any type of soil n.exc 1.5m wide and but exc 1.5m deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 metres and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type-I, flat, size 250mmx150mmx40mm, complete all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 25 sqmm, 4 core and taking down, complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .