Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Bid accepted being lowest tenderer | |
| 2 | L2₹22.0 L+₹2.6 L (13.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 3 | L3₹24.0 L+₹4.6 L (23.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 4 | L4₹28.9 L+₹9.5 L (48.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer hence rejected |
Tender Value
₹24.6 L
EMD Value
₹49,300
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE MAMUN
HEADQUARTERS CWE MAMUN PIN-145001
REPAIR /MAINTENANCE OF HT SYSTEM AND CONNECTED ALLIED WORK UNDER AOR OF GE SAMBA
2022_MES_557452_1
CWE/M-34/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SAMBA
Class E b (ii)
7 documents required · 7 mandatory
₹500
GE SAMBA
₹49,300
Yes
1 Dec 2022
13 Oct 2022
21 Nov 2022
13 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
Excavation in trenches in any type soil n. exc. 1.5 Mtr in width and not exceeding1.5 Mtr in depth and getting out all as required for laying of cable/ poles complete all as specified and directed.
Excavation in trenches in soft/loose soil n. exc. 1.5 Mtr in width and exc. 1.5 Mtr but not exc. 3.00 Mtr in depth and getting out all as required for laying of cable/ poles complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required complete all as specified and directed.
Supply and laying unreinforced precast cement concrete cable cover, class HV, type 1 with peak, size 300 mm x 180mmx 40mm all as required as in protection of cable complete all as specified and directed.
Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable all as direted.
Material and labour for plain cement concrete (1:4:8) type D-2 with using 40mm graded stone aggregate as in foundations and mass concrete etc complete all as specified and directed.
Material and labour for plain cement concrete (1:3:6) type C-1 with using 20mm graded stone aggregate as in coping of poles and foundation of stay etc including necessary form work, complete all as specified and directed.
Taking down of XLPE cable of any size and capacity complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 120 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches of complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 95 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches complete all as specified and as directed.
Supply, fixing, commissioning and testing of Aerial bunched XPLE insulated with aluminium conductor stranded 11000 volt grade 3 single core cross sectional area 95 sqmm and one 70 sqmm aluminium conductor messenger for cable including anchor clamps made out of MS angle 32x3x6 mm complete with clamps and nuts and bolts for cable on poles incl dismantling of existing over head conductor complete all as specified and directed.
Material and labour in repairs Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE HT armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed, Make all as mentioned in Annexure-1
Material and labour in repairs Cable end jointing kit for 11 KV (earthed) grade cable for out door type termination heat shrinkable type joint complete with all jointing material and accessories suitable for 3 core XLPE HT armoured aluminium conductor cable of size 120 to 185 sq mm complete , all as specified and
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for out door termination heat shrink type complete with jointing material and accessories suitable for single core ABC aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Taking out the unserviceable gand operated device after disconnecting the electric HT supply and Supply and fixing air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators (15 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 400 amps etc complete, all as specified and directed.
Material and labour in replcement of structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of zink chrome primer and two coats of aluminium paint for 11KV insulation complete all as specified and directed.
Taking down existing unserviceable / old ACSR conductor from over head lines complete all as spd and directed.
Supply and fixing aluminum conductor steel reinforced (ACSR) for HT/LT lines on PCC/steel tubular poles, streching without kinks and bends including aluminum binding wires of size Ferret to Dog as per load complete all as spd and directed.
Supply and fixing stay assembly complete comprising of 16mm dia, 40cm long stay bow rod 16mm dia x 1.8 Mtr long galvanised stay rod threaded and with nuts including 300mm x 300mm x 6mm thick plate GI, stay wire, stay clamps and necessary clamps for any type of pole etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete including taking down U/S stay assembly all as specified and directed ( Note : Loop type insulator, excavation and concrete work shall be measured and paid separately).
Dismantling insulators any type and size complete all as specified and directed.
Supply and fixing in replacement loop type insulator with complete fitting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm all as specified and directed.
Supply and fixing in replacement galvanised steel stranded stay wire size 7/3.15mm for stay assembly complete all as specified and directed.
Restretching of ACSR conductor of any size of over head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: (a) ACSR conductor Required for winding etc is deemed included in quoted rates. (b) The distance between two poles shall be considered as one Span for measurement proper.
Trimming up of tree branches upto 5 mtr all around HT overhead lines, removing cut branches from site complete all as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 5 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department accordingly. The trimming work shall be commenced once it is permitted by AGE.(ii) Only effected Span at site shall be measured where tree branches are touching nearly HT/LT lines. No claim whatsoever shall be entertained by the deptt at later stage. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and outcome whether lines are free from tree branches or not kept on record for payment. (iv) The OH line will be maintained for whole period of contract and full payment will be made with Final Bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above.
Taking out broken old poles of any type complete all as specified and directed.
Material and labour for erection of steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including factory painting with anti corrosive paint internally complete and externally up to planting depth, alternative Yellow & Black strips of 30 cm height upto 1.5 mtr above ground level complete all specified and directed. Note: Excavation and earth work, GI pipe, clamps shall be measured and paid for separately under respective items.)
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 3 of SSR -2009 Part II, all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe medium grade 40mm and GI watering pipe 20mm light grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Material and labour for earthing complete with galvanised steel earth plate electrode , 600x600x6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal , and salt precast PCC 1:2:4 (Nominal mix ) cover with suitable steel handle , and angle iron 40x40x3mm frame for pit cover , PCC 1:2:4 pit including earth work in any type of soil , removal of surplus soil to a distance n.exc 50mtr and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part II complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Material and labour for GI pipe in replacement ( Light grade ) for protection of HT cable fixed to walls/ poles/road crossing including suitable size clamps complete of size 80mm bore, all as specified and directed.
Supply and fixing of chain link fencing mild steel galvanised with 100 mm size of mesh, 10 gauge including line wire secured and fitted to angle/RCC poles complete all as specified and directed. Note:- PCC/angle shall be measured and paid separately.
Repair /servicing /Calliberation to HT panel of make : Kirloskar having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:- (a) Cleaning of VCB with air blower and removing dust particals (b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible. (e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values. (g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended. (h) Recording IR values of CTs and PTs (j) Cleaning of bus bar spout. (k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB. (ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. "Y" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor.
Repair /servicing /Calliberation to HT panel of make : ABB having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:- (a) Cleaning of VCB with air blower and removing dust particals (b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible. (e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values. (g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended. (h) Recording IR values of CTs and PTs (j) Cleaning of bus bar spout. (k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB. (ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. "Y" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor.
Repair /servicing /Calliberation to HT panel of make : Kirloskar having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:- (a) Cleaning of VCB with air blower and removing dust particals (b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible. (e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values. (g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended. (h) Recording IR values of CTs and PTs (j) Cleaning of bus bar spout. (k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB. (ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. "Y" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor.
S&F in replacement of plug & socket assembly suitable for VCB 11 KV complete all as specified.
S&F in replacement of manual spring charging handle suitable for VCB/OCB 11 KV complete all as specified.
Taking down unservicable triping coil from HT panel and supply and fixing new triping coil 30 volt DC suitable for 11KV HT panel of make : Kirloskar ,cat part no as per OEM of existing panel complete all as directed and specified by Engr-in-charge.
Taking down unservicable triping coil from HT panel and supply and fixing new Master Trip Relay 30 V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-chagre. Make: ABB, model no: RXMVB2 or technocommerically equivalant model in Schneider / Kirloskar /Alstom.
Taking down unservicable triping circuit supervision relay and S&F new trip circuit supervision relay of 30 V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-chagre. Make: ABB model no : RXI series or technocommerically equivalant model of Siemens/ Schneider.
Taking down unservicable triping circuit supervision relay and S&F new trip circuit supervision relay of 110-125 V DC suitable for 11 KV HT panel for protection system of make: ABB model no : RXI series or technocommerically equivalant of Siemens/ Schneider complete all as directed and specified by Engr-in-chagre.
Material and labour for detection of fault in HT/LT underground cable laid in plane or any type area with the help of cable fault locator machine including providing conveyance and any other means required at site, isolating and reconnecting cable after identifying fault all as specified and directed. Note: Excavation, Returing filling upto required depth is demmed to be included in above quoted rate.
Taking down unservicable over current and earth fault relay and S&F new over current and earth fault relay suitable of 30 V DC suitable for 11 KV HT panel for protection system of make:Easergy of Schneider of P3 series or technocommerically equivalant of ABB /Siemens complete all as directed and specified by Engr-in-chagre. (Note: T&P and ladder for painting will be deemed included in the quoted rate)
M/S GUPTA TRADING CO
dinesh enterprises
Bharat Builder
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .