| 3 | Rejected-Technical FIRST FLOOR 1115 SECTOR 17B 1115 FIRST FLOOR SECTOR 17B GURUGRAM GURGAON HARYANA HARYANA GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | Rejected-Technical Technically Not Qualified |
Tender Value
Refer Docs
EMD Value
₹58,600
Closing Date
3 Mar 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Registrar, SNBNCBS
S N Bose National Centre for Basic Sciences, Block - JD, Sector - III, Salt Lake, Kolkata - 700106
Supply, Installation, Testing and Commissioning of Light Commercial ACs in place of old and defunct AC at various locations of SNBNCBS, Salt Lake, Kolkata.
2021_SNBNC_615335_1
SNB/ENGG/NIT/2020-21/06
Open Tender
Electrical Works
Item Rate
90 days
S N Bose National Centre for Basic Sciences
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹58,600
Yes
S N Bose National Centre for Basic Sciences
27 Apr 2021
9 Feb 2021
9 Mar 2021
9 Feb 2021
3 Mar 2021
11 Feb 2021
11 Feb 2021
120 days
Amount
SITC of 7.5 TR High-Static Fan Coil Airconditioning Unit with of rated cooling capacity of 90000 BTU/hr with 3 Nos. Reciprocating type Compressor with Microprocessor based Control Panel, 3 nos. IDU of rated power supply 400V-3ph-50Hz with centrifugal blower and corded remote control . Air-flow/per IDU 1000CFM including charging of refrigerant ( Make: Carrier / Mitshubishi Heavy Industries / Daikin / O-General/ Toshiba)
SITC of 5.0 TR High Static Fan Coil Airconditioning Unit with of rated cooling capacity of 60000 BTU/hr with 2 Nos. Recip./Twin rotary type Compressor , 2 nos. IDU of rated power supply 230V-Single.ph-50Hz with centrifugal blower and corded remote control . Air-flow/per IDU 800CFM including charging of refrigerant ( Make: Carrier / Mitshubishi Heavy Industries / Daikin / O-General/ Toshiba)
SITC of 2.0 TR High-Static Fan Coil Airconditioning Unit with of rated cooling capacity of 24000 BTU/hr with 1 No. Recip./Twin rotary type Compressor , 1 no. IDU of rated power supply 230V-Single.ph-50Hz with centrifugal blower and corded remote control . Air-flow/per IDU 800CFM including charging of refrigerant ( Make: Carrier / Mitshubishi Heavy Industries / Daikin / O-General/ Toshiba)
Supply and fixing of hard/soft copper refrigeration pipeline with 9 mm thick Nitrile Rubber insulation, complete with fittings, elbows, bends, supporting arrangement on walls for suction line & Liquid Line both together, complete in all respect.
5/8" & 3/8" for 7.5 TR/5.0 TR fan coil units
5/8" & 1/4" for 2.0 TR fan coil units
Supplying and laying of 1.1 KV grade XLPE multi core control cable for connecting conrresponding IDU to corresponding ODUs as per standard code of practice and in accordance with rules of local Electric supply Authority
Supplying & laying of 6 Core 2.5sq mm. (Make- Ploycab/Finolex/Gloster/Havells)
Supply & laying of copper power cable for the control unit 4 Core 4sqmm. + 2 X 2.5 Sqmm.(Make- Ploycab/Finolex/Gloster/Havells)
Supplying and laying of 4 Core1.5sq.mm.(Make- Ploycab/Finolex/Gloster/Havells)
Supply and fixing of Al powder coated continuous Grill (Make Premier/M.R/ Dynacraft/Systemair)
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.Make- Oriplast/ Supreme/Prince/Arrow
32 mm dia
25 mm dia
Supplying, fabrication & fixing of M.S u- channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit for 7.5 TR/5.0 TR/2.0 TR Outdoor split unit including drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform.The entire structure should be baricaded & safe for ODU Maintenance . Area of the platform is 3Mtr. x 1.2Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC
7.5 TR Fan Coil Unit
5.0 TR Fan Coil Unit
2.0 TR Fan Coil Unit
SupplyingRefrigerant R-22 and oil required for commissioning, testing, trial run till the system is handed over in satisfactory working condition.
SITC of 2 Tr, 5 star, full copper coil split Air-conditioner.( Make: Carrier / Mitshubishi Heavy Industries / Daikin / O-General/ Toshiba)
Buy back of Old ACs - 2 Tr Capacity Split
Buy back of Old ACs - 1.5Tr Capacity Split
Best Buy Air-Conditioners
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .