Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | ₹22.5 L Quoted ₹23.7 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹26.4 L+₹2.8 L (11.8%)Rejected-AOC | ₹26.4 L+₹2.8 L (11.8%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹27.6 L+₹4.0 L (16.8%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | ₹27.6 L+₹4.0 L (16.8%) | L3 | Rejected-AOC Not lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Jul 2020, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR / REPLACEMENT OF U/S ELECTRICAL FITTINGS AND FIXTURE, CEILING FAN, EXHAUST FAN, PEDESTAL FAN INCLUDING FLAME PROOF FITTING IN 33 SU AND LEFT OVER POCKET IN DOMESTIC AREA AT AF STN JODHPUR
2020_MES_353944_1
8409/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹60,000
Yes
12 Aug 2020
18 Jun 2020
16 Jul 2020
18 Jun 2020
15 Jul 2020
3 Jul 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by the Engineer-in-Charge.
Taking down MCB DB with MCB any type and any capacity complete all as specified and directed by the Engineer in Charge.
Taking down Sub main wiring any type any size complete all as specified and directed by the Engineer in Charge.
Material and labour for point wiring with 1.5 sqmm PVC insulated 1100 volt grade IS-694 FRLS multi stranded but unsheathed copper conductor cable drawing in existing steel /PVC conduit and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator including continuous earth wire with copper cable single core 1.5 sqmm similar description of main cable connected to main earth dolly for one light/ fan/Exhaust fan point controlled by one switch/regulator complete all as specified and directed by the Engineer in Charge.
All as per item No 4.00 above but for 5 amp socket on same board.
All as per item No 4.00 above but for 5 amp socket on independent board.
All as per item No 4.00 above but for One bell point controlled by one bell push.
Material and labour for point wiring with 2.5 sqmm PVC insulated 1100 volt grade IS-694 FRLS multi stranded but unsheathed copper conductor cable drawing in existing steel /PVC conduit and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator including continuous earth wire with copper cable single core 1.5 sqmm similar description of main cable connected to main earth dolly for for Independent one 3 pin 15 Amps socket outlet complete all as specified and directed by the Engineer in Charge.
Material and labour for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS-694 (Phase- Red/Blue/Yellow, Netural -Black and earth continuity conductor 1.50 sqmm Green) drawn through and including PVC casing caping not less than 20x12mm ISI marked ivory colour including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick phenolic laminated white sheet cover for mounting swiches, sockets, fan regulators etc complete for One light point/fan point controlled by one switch 5 amp one way complete all as specified and directed by the Engineer in Charge.
All as per item No 9.00 above but for 5 amp socket on same board
All as per item No 9.00 above but for 5 amp socket on independent board
All as per item No 9.00 above but for One bell point controlled by one bell push.
Material & labour for point wiring with 2.5 sqmm PVC insulated 1100 volt grade IS -694 FRLS multi stranded but unsheathed copper conductor cable drawing in and including PVC Casing/capping 20 mm in wall/surface and terminated in gang box with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator including continuous earth wire with copper cable single core 1.5 sqmm similar description of main cable connected to main earth dolly or Independent one 3 pin 15 Amps socket outlet complete all as specified and directed by the Engineer in Charge.
Supply & fixing switch piano 5 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing switch piano 16 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing socket outlet flush type 5 pin 6 amps complete all as specified and directed by the Engineer in Charge.
Supply & fixing socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed by the Engineer in Charge.
Supply & fixing bell push button flush type 5 Amps complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs of ding dong musical type, bell AC 230 V single pole complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular plate switches 6 amps single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular plate socket outlet 6 amps 5 pin complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular plate switches 16 amps single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular plate socket 6-16 A 3 pin combined ced shuttered complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular step fan Speed regulator 5 steps complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Steped type elecrtonic fan regulator flash type on the existing phenolic laminated sheet etc suitable for 240 volt complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repairs modular white cover platewith frame 12 modular complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Flush metal boxes 12 modular size 8" X 6" complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular white cover plate with frame 8 modular complete all as specified and directed by the Engineer in Charge.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 6 sqmm 1100 volt grade (ISI marked ) drawn through PVC casing and caping and all necessary fittings with one 4 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 4 sqmm 1100 volt grade (ISI marked ) drawn through PVC casing and caping and all necessary fittings with one 2.5 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 10 sqmm 1100 volt grade (ISI marked ) drawn through PVC casing and caping and all necessary fittings with one 6 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Supply and Fixing in repair Casing & Caping 25mm x 12 mm including all necessary fittings like bend, tee, socket etc. fixed with cadmium coated MS screw on wall / ceiling complete all as specified and directed.
Supply and Fixing in repair Casing & Caping 32mm x 12 mm including all necessary fittings like bend, tee, socket etc. fixed with cadmium coated MS screw on wall / ceiling complete all as specified and directed.
Supply & fixing in repairs MCBs of 'C' series, Single Pole(SP) 6 to 32 amps, having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series, Single Pole & Neutral (SPN) 6 to 32 amps, having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series,Single Pole & Neutral (SPN),40 to 63 amps, having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series,Triple Pole & Neutral (TPN), 6 to 32 amps, having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series, Triple Pole & Neutral (TPN), 40 to 63 amps, having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs LED fixture 8 watt including connections, operated at AC 240 Volt complete all as specified and directed by Engineer in Charge.
Supply and fixing factory made MCB distribution board SPN, 240 volts, 4 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by Engineer in Charge. Make - Legrand cat ref no 607710 or equivalent of make given in Appx 'B' as approved by GE.
Supply and fixing factory made MCB distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by Engineer in Charge. Make - Legrand cat ref no 607711 or equivalent of make given in Appx 'B' as approved by GE.
Supply and fixing factory made MCB distribution board TPN, 440 volts, 4 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by Engineer in Charge. Make - Legrand cat ref no 607712 or equivalent of make given in Appx 'B' as approved by GE.
Supply and fixing in repairs 1100 volt grade aluminium conductor cable, 10 sqmm twin core, heavy duty PVC insulated screened with inner sheathing of PVC tape and over all PVC sheathed in service connections, suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire complete all as specified and directed by Engineer in Charge.
Supply and fixing in repairs 4 mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required compete all as specified and as directed.
Supply and fixing in repairs LED tube rod 18/20 watt, 240 volts, 50 Hz AC complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs LED tube light fitting 18Watt with LED tube rod complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs energy efficient recessed mounted 36 W LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified and directed by Engr-in-charge. . Make - crompton cat ref no. LCTLR-36-FO-CDL of make given in Appx 'B' as approved by GE.
Supply and fixing in repairs 4 pin 36 watt CFL operating at 240 volts, 50 Hz AC supply complete all as specified and directed by Engr-in-charge.
Supply and fixing electronic chock 2x36 watt complete all as specified and directed by Engr-in-charge. Make - Bajaj/Havells/CG
Taking down carefully ceiling/exhaust fan of any sweep, and make, and Material & labour for overhauling of same with cleaning of dust properly, opening of fan. Oiling greasing of bearing including replacement of unserviceable parts condenser, split pin etc provision of PVC copper twisted conductor three core of size 0.5 Sqmm of required length and refixing /hanging the same after overhauling complete all as specified and directed by Engr-in-charge.
Taking down carefully and opening, dismantling of ceiling fans 48" sweep cutting and taking out old burnt/damaged winding/material by any means and M&L for re-winding the same with supper enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan with recommended quality grease/oil, re-assembling including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length and testing complete all as specified and directed by Engr-in-charge.
Taking down carefully and opening, dismantling of exhaust fan 450mm sweep by any means and taking out old burnt/damaged winding/material by any means and material and labour for rewinding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan bearing/bushing and greasing/oiling the same with recommended quality grease/oil, reassembling and testing including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length complete all as specified and directed by Engr-in-charge.
All as per item No 52 herein above but exhaust fan 380 mm sweep all as specified & directed. Note for item no.50 to 53 :- Spare parts shall be measured and paid seperately under respective items of BOQ.
Supply only bearing of ceiling/exhaust fan complete all as specified and directed by Engr-in-charge. Make- (NBC/SKF/TATA)
Supply only capacitor 415 Volts, 50 Hz 2.5 MFD and connect the same in circuit and testing complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 415 Volts, 50 Hz 4 MFD and connect the same in circuit and testing complete all as specified and directed by Engineer-in-Charge.
Supply only bush suitable for ceiling/ exhaust fan any sweep and oiling complete all as specified and as directed by Engineer-in-Charge.
Supply only armature shaft of ceiling fan of any sweep etc complete all as specified and as directed by Engineer-in-Charge.
Supply only rubber reel with clamps, nut bolts washers and split pin of suitable size for ceiling/exhaust fan all as specified and directed.
Supply only fan canopy plastic body suitable for any type/any make/any sweep of ceiling fan all as specified and directed .
Supply only ceiling fan down rod of metal ,15mm dia 450mm long suitable for any type of ceiling fan all as specified and directed.
Supply only metallic blade for ceiling fan 1200 mm sweep including bolt for fixing complete all as directed by Engineer-in-Charge.
Supply only Bracket , legs and rubber bush suitable for existing exhaust fan of any size all as directed by engineer-in-Charge.
Supply only metallic blade (four blade set) for exhaust fan 450/350 mm all as directed by Engineer-in-Charge.
Supply only replacement plug top 3 pin 15 Amps ISI marked all as directed by Engineer-in-Charge.
Supply only replacement plug top 2/3 pin 5 Amps ISI marked all as directed by Engineer-in-Charge.
Taking down carefully and opening, dismantling of ACB and Material & labour for repair of ACB of any rating by replacement of required/defective parts like spring charge mechanism, handle, push button, LCD display etc and make it functional, operational including testing of tripping of ACB according to the their load complete to the entire satisfaction of the Engineer in charge.
Provide the labour and T&P for site clearance not exc 15 cm in depth in any type of soil in Sub stations area, trenches, sub station rooms, two pole/ four pole structure surrounding, LT panel, fencing to make a over all presentable condition all as directed complete to the entire satisfaction of the Engineer in charge.
Supply & fixing in repairs fan hook of suitable size 15mm dia/chennal type 'J ' hook of any type and length complete all as specified and directed by the Engineer in Charge
Supply & fixing in repairs sheet metal enclosure SPN with a two pin and earth plug socket complete with and including one number of 32 Amps MCB 'C' single pole 240 Volt AC complete all as specified and directed by the Engineer in Charge
Disconnecting and taking down old unserviceable KWH meter (Electric energy meter) "Single phase" from any situation and any description , repair the same with replacement of required/defective parts i.e LCD display, Electronic card, optical port, connection wires etc and make it functional & operational complete to the entire satisfaction of the Engineer in charge and re-fixing the same after repairing and electrically connection and testing complete.
Supply and fixing in repairs vitreous porcelain insulators on walls/ roofs in existing AL/Cu strip of any size complete all as specified and directed by Engr-in-charge..
Material & labour for in repairs earthing complete with Copper electrode 60cmx60cmx3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of size 32x6mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Any type of Soil, PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Material & labour for in repairs earthing complete with Copper electrode 60cmx60cmx3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of size 32x6mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Hard Rock, PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Dismantling of old earth pit chamber and Material & labour for construction of eathing chamber pit of size 300mm x 300mm, thickness 50 mm and height of chamber 100 mm made of PCC 1:3:6 type C1, PCC surfaces finished even & smooth of earth pit and provision of PCCC cover of suitable size and thickness in PCC 1:2:4 type B1, including formwork and excavation etc comple all as specified and directed.
Material & labour in replacement galvanised steel strip 25mmx4mm complete with, protection sleeves, saddles, seperator and fixing screws at surrounding inside and outside the building complete all as specified and directed by the Engineer-in-Charge.
Material & labour in replacement copper strip 20mmx3mm complete with, protection sleeves, saddles, seperator and fixing screws at surrounding, inside and outside the building complete all as specified and directed by the Engineer-in-Charge.
Supply only Potassium Nitrate (commercial name kalmi shora) in the earthing chambers for improvement of the existing earthing resistence complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for dismantling old LT panel and removing all the connection including copper/aluminium busbar & removing the carbon from the contacts by cleaning through CTC solution and, after disconnecting cable, replacement of the unserviceable or defective parts like rusted nuts and bolts, old damaged/corroded door hinges /door lock/bus bar, front or back door etc and reassemble the panel with all the connection properly tight and checked. Control wiring and CT PT connection of the panel shall be properly checked and made good to make the LT panel serviceable to the entire satisfaction of the Engineer in Charge. Foundation if deteriorated of the panel shall be repaired with existing specifications and painting the base frame properly mounted complete all as specified and directed by the Engineer in Charge.
Supply only LT panel /AMF panel/HT bus panel front /back door made of GI 3.15 mm thick with hinges and lock system complete all as specified and directed by the Engineer in Charge.
Supply only copper in bus bar of existing size for LT panel including pvc Insulation ,reconnection of LT cable and seperator complete all as specified and directed by the Engineer in Charge.
Material and labour for complete removal of existing treatment from iron surfaces of the LT panels (area to be painted 10 sqm to 25 sqm) by cleaning, rubbing, scrapping down the surfaces & prepration of surfaces with and including applying two coats of synthetic enamelled paint over a coat of primer, color of paint shall be as per the existing colour of panel complete all as specified and directed by the Engineer in Charge. Note:- Painting to Panels Shall be carried out with spray gun equipments.
Material and labour for complete removal of existing treatment from iron surfaces of the LT panels (area to be painted 26 sqm to 50 sqm) by cleaning, rubbing, scrapping down the surfaces & prepration of surfaces with and including applying two coats of synthetic enamelled paint over a coat of primer, color of paint shall be as per the existing colour of panel complete all as specified and directed by the Engineer in Charge. Note:- Painting to Panels Shall be carried out with spray gun equipments.
Material & labour in repairs of mild steel angle iron frame of reqd size & shape with and including necessary welding and fastenings, including one coat of black synthetic enamal paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Multi functional LED type digital meter suitable for measuring electrical parameters i.e, Amp meter, volt meter, frequency, power and power factor meter, etc 3 phase Class 1 AC with epoxy type CT of suitable ratio and complete wiring complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair phase indicating lamp R-Y-B. LED type , fixed in existing LT panel board etc complete all as specified and directed
Material & labour in replacement of out door type LT Feeder Pillar (Kiosk) of size not less than L=60 cmx 45 cm x45 cm (H) made out 3.15 mm thick CRCA sheet (CPRI approved) with openable Front door including locking arrangement with and inluding Copper Busbar 200 amps rating with one MCCB 125 Amps ,25 KA and fixed on angle iron frame of required size and PCC 1:4:8 in plinth complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs cable joint kit 1100 Volts stright through complete for aluminium cable of size 25 to 50 sqmm complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs cable joint kit 1100 Volts stright through complete for aluminium cable of size 70 to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs cable joint kit 1100 Volts stright through complete for aluminium cable of size 120 to 150 sqmm complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs cable joint kit 1100 Volts stright through complete for aluminium cable of size 150 to 300 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs MCCB 630 Amp, 4/3 pole, 415 V, 36KA complete all as specified and directed.
Supply and fixing in repairs MCCB 400 Amp, 4/3 pole, 415 V, 36KA complete all as specified and directed.
Supply and fixing in repairs MCCB 250 Amp, 4/3 pole, 415 V, 25KA complete all as specified and directed.
Supply and fixing in repairs MCCB 200 Amp, 4/3 pole, 415 V, 25KA complete all as specified and directed.
Supply and fixing in repairs MCCB 160 Amp, 4/3 pole, 415 V, 25KA complete all as specified and directed.
Supply and fixing in repairs MCCB 125 Amp, 4/3 pole, 415 V, 25KA complete all as specified and directed.
Supply and fixing in repairs MCCB 100 Amp, 4/3 pole, 415 V, 25KA complete all as specified and directed.
Supply and fixing in repairs MCCB 63 Amp, 4/3 pole, 415 V, 16KA complete all as specified and directed.
Supply, install, testing and commissioning in repairs on load change over switch 100 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure complete all as specified and directed.
Supply, install, testing and commissioning in repairs on load change over switch 200 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure complete all as specified and directed
Supply, install, testing and commissioning in repairs on load change over switch 300 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure complete all as specified and directed
Supply and fixing steel tubular swaged poles type 410 SP-22 , 9 metres long complete with cast iron base plate and finial taper plug, bolts, nuts & screws, including painting the complete pole with two coats of synthetic enamel paint over a coat of red oxide primer complete including numbering the poles with Synthetic enamel paint, excavation & earthwork in any type of soil, PCC (1:4:8) in foundation , PCC (1:3:6) in coping, including dismantling the old steel pole, breaking the old PCC foundation and removal of all the debries out side MD land complete all as directed by the Engineer-in-Charge.
Material & Labour for Pre-stressed concrete poles 9 metres long, size 152 mm x 152 mm at top and 152 mm x 260 mm at bottom, class 10, complying with requirement of IS-1678 of 1978 including painting the poles with two coats of synthetic enamel paint over a coat of primer in sky blue and white (15 cm high each) alternate strips upto 1.5 m height from top of PCC coping including numbering the poles in synthetic enamel paint, including necessary excavation & earthwork in any type of soil, PCC (1:4:8) in foundation , PCC (1:3:6) in coping , with and including dismantling the old PCC pole 9 meter, breaking the old PCC foundation and removal of all the debries out side MD land complete all as directed by the Engineer-in-Charge.
Material & labour in replacement of Stay assembly with galvanised stay strand of size 7/3.15mm complete with accessories including loop type insulator, stay clamps, stay plate of required size, excavation in any soil/ hard rock and PCC work etc for fixing of stay rod of 20mm complete all as specified and directed by the Engineer - in - Charge.
Material & labour for Unbinding ACSR conductor and insulators from the poles and restretching/restringing & fixing the same ACSR conductor of any size on same poles and binding the same with & including the new 2mm dia aluminium binding wire and making/tightening of jumpers at appropriate place to ACSR conductor complete all as specified and directed by the Engineer in Charge. Note :- All four wires between poles shall be considered as one length. Distance between pole to pole shall be considered as length of wires for the purpose of payment.
Material & labour in repairs for aluminium conductor, steel reinforced (ACSR) including 22 gauge aluminium binding wire, line connections and jumper etc (Squirrel, weasel & ferret) complete all as specified and directed by the Engineer-in-Charge. Note :- Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
Supply & fixing in repair 50mm high, 65mm dia Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 1100 volts grade complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repair Disc type, porcelain, vitreous, white, brown or green insulator 1100 Volts grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repair of 1100 Volt Current Transformer of rating 50/5 Amp complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 500 Sqmm 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core complete all as specified and directed by the Engineer-in-Charge. Note for srl item no.112 to 116 :- Earth work excavation, Returning, filling in , Removal ,sand filling & stone shall be measured & paid separately.
Material & Labour for excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation/cable trench/laying of pipe line/taking out pipe etc and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 m and deposing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and filling dry clean sand in trenches for cushioning of underground cable including punning down complete all as specified and directed. Note:- Only Punned down thickness shall be measured and paid
Laying only 40 to 50 mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and 80 cm in length received from excavation, laid dry abutting each other for under ground protection complete all as specified and directed.
Material & labour for Boring of holes under road, pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Material & labour for stone aggregate of size 40mm graded laid on ground of two/four/ pole structure complete all as specified and directed.
Material & labour for Rerouting/Rearranging of existing cable of any type and any size on wall, floor, roof, ground etc using metal cable clips of different sizes and make it presentable condition as per direction by Engr-in charge.
Supply & fixing in repair FRP Junction box of size 300mmx 300mm x 150mm for street light, central with linked door control including 6 Amp MCB SP with aluminium bus bar TPN for controlling the Street Lights with and including pole mounting arrangement complete all as specified and directed.
Supply & fixing in repair Aluminium lugs 10 to 70 sqmm for HT/LT cables complete all as specified and directed.
Supply & fixing in repair Aluminium lugs 95 to 300 sqmm for HT/LT cables complete all as specified and directed.
Supply & fixing in repair Aluminium lugs 300 to 500 sqmm for HT/LT cables complete all as specified and directed.
Supply & fixing rigid PVC, LT line spacers for four lines complete all as specified and directed.
Supply and fix in repair of SCRs used in thyrister switching in APFC panel all as specified and directed by engr in charge. make L&T or equivalent of makes given in appx 'B' as approved by GE.
Nvimal Engineer and Contractor
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .