| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.7 CrAdmitted-Finance | -14.66% | ₹16.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹18.3 CrAdmitted-Finance | -6.32% | ₹18.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹19.4 CrAdmitted-Finance | -1.01% | ₹19.4 Cr | L3 | Admitted-Finance |
| 4 | L4₹20.3 CrAdmitted-Finance KANNUR | KERALA | 670001 | +3.86% | ₹20.3 Cr | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical rejected as per minutes of meeting of pre qualification tender committee |
Tender Value
₹19.6 Cr
EMD Value
₹5 L
Closing Date
20 Feb 2026, 3:00 pmClosed
Superintending Engineer, Buildings North Circl
Superintending Engineer, Buildings North Circle
This proposal is for constructing building for D Block with DDMA complex, the building proposed consists of Gplus4 floors with Total Built-up area of 4198.2 square meter. Each Ground floor and first floor having 835.8 squre meter
2026_PWD_835767_1
PWD/BLDG/TR/713/2026_23_2_1
Open Tender
Civil Works - Buildings
540 days
Kalpetta
Please refer Tender documents.
15 documents required · 15 mandatory
₹16,540
Yes
₹5 L
Yes
2 Mar 2026
11 Feb 2026
23 Feb 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
Buillding Work(Civil work)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
OD290712/2025-2026:Chemical blasting with oil using explosive and removing the hard rock (measured in solid) for site levelling approved lines and levels etc.By drilling holes of suitable dia 20 cm c/c and filling it with suitable chemical like accones etc.
OD290714/2025-2026:Providing Twisted steel/deformed TMT Dowel bars with 20 mm dia, 2.10 m long @ 0.50 m spacing and anchored by hard rock 1.00 m and inserted to concrete by 1.10 m as per structural design including drilling holes of dia 25mm in to depth of 1.00 m in to rock and filling the gap with cement grout (0.10kg/E) etc. complete
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
OD290713/2025-2026:Dry rubble masonry with hard stone in foundation and plinth with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
OD292952/2025-2026:Dry rubble masonry with hard stone in superstructure above plinth level and upto floor five level with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
OD290708/2025-2026:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is not payable or recoverable separately. All work up to plinth level
OD290707/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 340 kg/cum. Excess or less cement used as per design mix is not payable or recoverable separately. All work above plinth level upto floor V level
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.2:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsAbove 20 cm wide
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
50.6.1.3:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
6.13.1:Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement : 3 coarse sand)
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
OD290711/2025-2026:Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with 3 mm thick epoxy grout etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size Size of Tile 800 x 1200 mm
OD290706/2025-2026:Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with 3 mm thick epoxy grout etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified tiles polished finish of size Size of Tile 800 x 1200 mm
OD290715/2025-2026:Providing and laying vitrified( matt or Glosy) floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including Grouting the joints of flooring tiles having joints of 3mm width ,Using epoxy grout size of tile 600x600 complete.
OD290710/2025-2026:Providing and laying Vitrified( matt or glossy) tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including Grouting the joints of flooring tiles having joints of 3mm width ,Using epoxy grout size of tile 600x600 complete.
11.55.1: Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
11.20.4:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment
16.89:Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
16.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
9.147A.1:Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
9.147A.2:Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm).
9.147D.2:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
9.147D.4:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.2:Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
21.18:Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
OD290709/2025-2026: Providing and fixing 10 mm thick frameless toughened glass partition of approved brand and manufacture, including providing and fixing side & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge
26.93.2: Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ? 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers. The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the C-clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends. The vertical joint open groove between two adjacent tiles shall be 10mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge.“Note : Scaffolding wherever required to be paid separately.With 24mm thickness (+/- 10%) terracotta tiles of other than grey colors
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.2.1:Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood
50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
9.88:Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
21.4.2:Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With brass cover plate minimum 1.25 mm thickness
21.12.3:Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
OD291147/2025-2026: Supply and installation of Zebra Roller blinds including conveyance charges, labour etc complete. Colour and size as per the direction of Engineer in charge
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
9.74.1:Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm
9.74.2:Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:200x10 mm
9.81.1:Providing and fixing bright finished brass handles with screws etc. complete:125 mm
9.82:Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
9.84:Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
16.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
10.6.3:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
OD313877/2025-2026:Filling 6mm broken stone in sunken slab including all cost carriage of materials and labour charges for sunken floor filling etc. complete
OD314320/2025-2026:Providing and fixing Stainless Steel coated 3D letter 25 mm thick and 280 mm width of approved brand fixed with Stainless steel screws along the wall surface including all cost and conveyance of materials labour charges, fabrication charges, scaffolding charges etc. complete.280 mm letters
Plumbing and Sanitary installation(Civil work)
50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
50.18.7.5.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6Kgf/cm2 - Internal work - Exposed on wall
50.18.9.15.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall
50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
50.18.8.8.2:Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2
50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
50.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
50.18.9.21.3:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow
50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
18.8.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.19.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
17.4.3:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern
17.7.3:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
17.32.4:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
18.63:Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
18.32.1:Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
8.10.2:Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade
interior and allied Works(Civil work)
9.7.3.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Ply wood 5 ply, 9 mm thickDecorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type.
OD291019/2025-2026:Providing and Fixing stainless steel Door Handle fixing for doors as per the direction of Engineer In Charge
9.76:Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
26.24.1:Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete.With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles
26.23.1:Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge.With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
12.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
9.81.1:Providing and fixing bright finished brass handles with screws etc. complete:125 mm
9.84:Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.169:Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails, screws etc. complete as per direction of Engineer-in-charge.
Electrification(Electrical work)
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
OD301417/2025-2026:Supply Installation Testing and Commissioning of 3600 lumen square(2ft X 2ft) recessed fitting made of diecast aluminium body, polycarbonate diffuser, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (UGR less than 19) all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc. as required. Chip make Cree/Osram/lumilled/Nichea Make- Philips Cool White Recessed Troffer G6 LED Panel Light or equivalent.
OD304853/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of 2400 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip makeCree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
OD305239/2025-2026: Supply, conveyance installation testing and commissioning of the LED light fittings of 1200 lumen round/ square surface mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
OD306499/2025-2026:Supply ,installation,testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required.
OD305884/2025-2026:Supply of LED strip light , system wattage 23 Watt/5m/roll with 3000K in the existing indoor coves with required length of 16/1.00 sq mm 3 core copper conductor wire conforming to relevant ISS or extending the original wiring and giving connections etc. as required
OD307430/2025-2026:Supply of 120 W 12v LED strip light driver of reputed company and giving connection as required.
OD306014/2025-2026:Supply, Conveyance, installation and testing of Mirror light (Picture light) suitable for 12 W LED (Philips Nebula Model no 31440 or equalent) directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
15.1:Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required
OD306016/2025-2026:Supply, conveyance, installation , testing and commissioning 225 mm sweep Light Duty Exhaust fan in metal body working on 230V single phase A/C, existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan
OD306018/2025-2026:Supply, conveyance, installation , testing and commissioning of 300/305mm sweep Heavy Duty Exhaust fan in metal frame in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD308104/2025-2026:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no's blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% including remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg Celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.5.1.6:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Gong bell 75mm-without MS box
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.3.7:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters
OD311111/2025-2026:Supply ,installation,testing and commissioning of 9600 lumen LED, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD306383/2025-2026:Steel reinforcement for RCC work including straightening , cutting , bending and placing in position and binding all complete.
OD306787/2025-2026:Supplying and fixing 24Hours Timer for operating ON-OFF function in 1the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required.
OD306507/2025-2026:Supplying and fixing 32A 2Pole AC1 Power contactor in Din bar complete with connections, testing and commissioning etc. as required.
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD306838/2025-2026:Supplying and clamping 20 mm dia corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.7:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 1.5 sq. mm
1.17.8:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid
90.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
OD310647/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 6 module mounting box
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
OD307120/2025-2026:Supply and installation of C R C A sheet steel, minimum thickness 1mm phosphatised and powder coated, dust and vermin proof 4P enclosure along with 40 A to 63 A, TPN MCB (C curve), 10 kA breaking capacity on surface /recess complete with connections, testing and commissioning etc. as required.
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.20:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
OD306891/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
OD308480/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554(part I)/1988 for PVC & IS 7098(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 4x25 sqmm
OD308517/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554(part I)/1988 for PVC & IS 7098(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 4x10 sqmm
OD311112/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required . 2x6sqmm
OD311113/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on cable tray as required. 2x6sqmm (clamped with 1mm thick saddle)
OD308522/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x35 sqmm
OD308624/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x95 sqmm
OD308629/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x185 sqmm
OD308630/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x25 sqmm (clamped with 1mm thick saddle)
OD309007/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x35 sqmm (clamped with 1mm thick saddle)
OD309012/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x95 sqmm (clamped with 25x3mm MS flat clamp)
OD309013/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x185 sqmm (clamped with 25/40x3mm MS flat clamp)
OD309052/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x16 sqmm (clamped with 1mm thick saddle)
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size
90.12.9.4:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench77/63 mm or nearest size
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
OD307457/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 25 sq mm - 95 sq mm with 20 mm wide x 1.20 mm thick clip
OD307458/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the 4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip sizes of cables as required.
OD307459/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.<br>95 sq mm - 185 sq mm with 20 mm wide x 1.20 mm thick clip
OD309196/2025-2026:Providing and drawing 2.65 mm(12 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD309204/2025-2026:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD309247/2025-2026:Providing and drawing 4.0 mm (8 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD309250/2025-2026:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & shall conform to relevant IS .Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurements will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
90.14.11.6:MCCB AccessoriesSupply and fixing 250 - 400A earth fault module of MCCB with builtin CBCT.
OD307466/2025-2026:Supply and fixing V,A,F, 3 Phase meter (multi function meter) with accuracy class 1 in the existing panel assembly and giving connection etc as required.
OD307467/2025-2026:Supply and fixing Blue colour LED indicator, AC/DC, 22.5 mm cut out dia
OD307468/2025-2026:Supply and fixing Red, Green, Black, Yellow, Orange colors LED indicator, AC/DC, 22.5 mm cut out dia
OD307469/2025-2026:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
OD307470/2025-2026:Supply and fixing 250/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT in the existing panel assembly as required.
OD307471/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to the fire extinguisher etc. as required. 2.5 cm, 4 cm, 5 cm height
90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.13:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.17:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.24.31:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.34:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
OD309578/2025-2026:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 4-7 KVAR & with 1 NO+1NC auxiliary contact in the existing panel assembly and giving connection etc as required.
OD309581/2025-2026:Supply and fixing 3pole,capacitor duty contactor with AC coil for switching capacitor banks of rating 7.5-10 KVAR & with 1 NO+1NC auxiliary contact in the existing panel assembly and giving connection etc as required.
90.14.29.3:S & F Motor starters accessories of the followingPush button station for starters
OD307473/2025-2026:Supply and providing 8 stage 440/110V 5/1A Intelligent power factor controller in the existing panel board and giving connection.
OD307474/2025-2026:Supply and providing 150 mm panel mounting cooling fan with fresh air grill as required.
OD307351/2025-2026:Supply, conveyance, installation, testing and commissioning of 160 KVA Indoor Type Unitized Substation comprising of H.T. panel trunked with cast resin Transformer with 630A VCB on H.T. side and bottom / top entry cable box as per technical details furnished below. H.T. Portion H.T. Portion consists of 1 No 11K.V, 630A, 350M.V. A VCB with 2O/C relay with high set elements one E/F relay with DC trip with earth inter lock with main switch and mechanical ON/OFF indication, with shunt trip coil for the remote operation of the VCB. Transformer Portion consists of 160 KVA, 11 K.V, 50 Hz, Delta/Star (Dyn-11) connected cast resin insulated copper wound transformer, Ratio 11KV/433, 3 Phase AN cooled. The core shall be laser scribed. Class 'F' insulation level shall be maintained. The maximum total loss of the transformer shall meet latest ECBC standards. OFF load tap changing facility shall be incorporated so as to achieve tap position from +5% to -10% in steps of 2.5% changeable by tap links. Temperature scanner with trip annunciator is to be provided. The transformer shall confirm to IS 2026: Part 11 2021/ IEC 60076-11:2018 Dry type Transformer. The transformer shall be subjected to all routine tests as per the relevant IS/ IEC standards and shall have all other standard fittings as per IS: 2026. TOD Metering Facilities consists of 3nos (rating suggested by K.S.E.B) 15VA, 0.2S Class Accuracy Cast resin C.T. 1No 3Phase 3Limb 11KV/110V, 10VA, 0.2 Class accuracy Cast resin P.T. with protective fuses. Provision for fixing TOD meter & test terminal block, (TOD meter and CT, PT unit compartment shall be so fabricated. So as to enable the K.S.E.B authorities to seal it). and including arranging testing and installation of the same with K.S.E.B. Testing Division. LT Portion consists of 1No 4Pole 400A 50KA microprocessor base MCCB inbuilt earth fault with setting range 50-100% with shunt release and rotary handle including NCT and MC12 relay. All inter connection from HT VCB switch to transformer and to LT breaker shall be given using Copper bus bars and support insulators. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side including LT Cable Box. Phase barriers and shrouding as per rules has to be given. The enclosure shall comply to IP 23 standards made of 2 mm CRCA sheet and shall have provisions with Epoxy powder coating the assembly after subjecting to 7 tank processes. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation and efficient Cooling, required including Danger boards, signage, lettering etc. required as per standards. The USS shall be installed at site as per the directions of Engineer in charge.
OD307358/2025-2026:Supply and Laying of 11KV, 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in the existing RCC/ HUME/ METAL pipe as required compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest
OD307361/2025-2026:Supply, laying and clamping of 1no: PVC insulated and PVC sheathed armoured aluminium power cable,11KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60 cms, making good the damages ,colour washing etc. as required 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated , insulation screened with extruded semi conducting compound in combination with copper tape(0.3 KA for 1 sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS:7098 part II 1985 with latest amendments
OD307352/2025-2026:Supply, installation, Testing and commissioning of 11KV Multi Panel VCBM/LBS/LBS Indoor 1) 1 No. 11K.V, 630A, 23.6KA VCBM as incomer and 2 nos. Load Break switch as out going and may extendable for future. 1 number 630A, 26.3kA for 3 sec Horizontal Draw out VCB fitted with Manual/Motor operated spring charging mechanism with 230V AC motor and motor control switch, shunt trip coil of 24V DC, closing coil of 24V DC, Auxiliary Contact 2NO + 2NC, Mechanical ON/OFF indicator, mechanical operation counter, protection CT, (--/5A, 5P10,15VA, 11KV/110V, Cl-0.2, 25VA PT Instantaneous IDMT relay with Microprocessor based 3O/C + and 1EF Protection relay, Strip Heater with thermostat, Digital Ammeter and Digital Voltmeter, Power pack 230V AC- 24 V DC emergency OFF push button and 2 numbers of 11 KV, 630A, 26.3 kA/1 sec Air break manual front operated LBS tripping coil rated for 230V AC as out going and giving connections etc as required.
OD307355/2025-2026:Supply , installation , testing and commissioning of approved make HT bi directional TOD net meter of accuracy class 0.2S with necessary test terminal block in the existing meter box after submitting the test certificate from KSEB TMR Division giving all connections etc. as required.
4.1.4:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
OD307448/2025-2026:Supply fabrication and installation of MS cable tray using required size MS angles/ MS flats including all supports and bolt nut etc complete and painting the tray with 2 coats of enamel paint over a coat of metal primer.
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
OD311102/2025-2026:Supplying, installing by suspension on ceiling/ along the wall, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners. connecting to earthing system etc. as required 250 amps 25 KA SC for 1 sec
3.12.1:Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50HzA.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as required 125 amps 15KA SC for 1 sec
3.4.1:Supplying, installing, testing and commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required.200 amps TPN
OD307449/2025-2026:Supply of High speed diesel (HSD) for full tank of DG set including conveyance,loading and unloading
18.8.7:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 100 mm
OD310183/2025-2026:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 125 mm
OD307456/2025-2026:Supply and providing Cladding for 100mm Exhaust pipe using 10 inch dia aluminium cladding with 26 gauge aluminium sheet ,Rock wool ,chicken mesh etc as required.
OD310316/2025-2026:Supply and providing Cladding for 125mm Exhaust pipe using 10 inch dia aluminium cladding with 26 gauge aluminium sheet ,Rock wool ,chicken mesh etc as required.
OD310321/2025-2026:Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe,GI funnel with weld mesh,25x5 mm GI clamps,CI/MS cover plate with locking arrangements,charcoal/coke and salt etc including providing brick work masonry enclosure at the top (450x450x450mm inside)etc as required.
5.11:Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
OD307412/2025-2026: Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of crystalline silicon type- mono perc Half cut solar cells, Solar Grid Tied inverter, bi-directional net metering facility, necessary protections, earthing, mounted on Aluminum/GI structure of suitable strength with following components complete as required:- a) On grid Solar PV Modules of the crystalline silicon type- mono perc Half cut, Conforming to MNRE specification mounted on Aluminium frame(minimum thickness 35 mm) With minimum module efficiency of 20%, manufactured in India. As per latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon. Matching IEC 61215 and IEC 61730 Part-1 & Part 2 standards or equivalent BIS. With necessary MC4 connectors (IP66) ,Interconnecting between panels using solar dc cable of min 4 sqmm and installation on existing structure .Solar crystalline modules of minimum 540Wp or above wattage. With Protective devices against surges at the PV module. Along with Low voltage drop bypass diodes . Solar Panels should be tested in the IEC authorized test centers. The rated output tolerance should be + 3 % . 10 years of product warranty 25 Years of linear power output warranty (90% of rated output at the end of 10years and 80% of rated output at the end of 25 years ) • b) MPPT Solar Grid tied inverter/Power Conditioning Unit(PCU) having Capacity 5KW (With IP54) with Canopy made of GI sheet of thickness 1.6 mm .BIS standard for efficiency measurements and environmental tests as per standard codes IEC 61683 and IEC 60068- 2(1,2,14,30) /Equivalent BIS Std. The charge controller (if any) / MPPT units environmental testing should qualify IEC 60068-2(1, 2, 14, 30)/Equivalent BIS Std. The junction boxes/ enclosures should be IP 65 (for outdoor)/ IP 54 (indoor) and as per IEC 529 specifications. The PCU/ inverters should be tested from the MNRE approved test centres / NABL /BIS /IEC accredited testing- calibration laboratories. In case of imported power conditioning units, these should be approved by international test houses. Max. efficiency 98.80 %. . European rated efficiency 98.20 % THDi <3 % Manufacturing warranty-10years.There should be a provision of free energy monitoring through portal. c) wall mounted suitable DC DB for on grid solar system for connecting 3 Nos solar panel string and DB consists of i). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, ii). 3set 20A DC Fuse and Holder for +ve and connector for -ve incomer side, iii). 3set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kA and giving internal connection using suitable wire, iv). 3set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs etc as required) d) wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of i). Poly carbonate Enclosure IP65 protection with transparent front cover with hinged door and termination arrangement, ii). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using suitable wire, iii). 40-63A 4Pole AC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs ets as required. e) DIN rail mounted type 4 pole, 415V, 50Hz contactor having the following specifications. Standard: IS/IEC 6094751, IEC 6094751, EN 6094751 Coil voltage: 240V AC Rated operational current at 415V: 4A(AC15) No. of Poles: 2NO+2NC Rated Insulation Voltage Ui (V): 690V Make: L and T MX0 22E or equivalent f)3Ph, 4wire , 110V , Class 0.2 S HT bidirectional Net meter ERP300P Trivector meter L & T or equivalent ( installing in the existing enclosure and giving connection to CT & PT including charges for testing the meter at testing lab as required g) Suitably rated MCBs, RCCBs and all other accessories as required. h) Dust and vermi proof metering board to fix KSEB meter and fuse, Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. i) Lightning protection with suitable Air terminals and accessories as per IEC -62305 part-3 16mm rod tapered to 10 mm dia aluminium rod : Meets the requirement of VDE0185/305(IEC 62305): semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Includes clamp made of SS tested to lightning current tested with VDE 0185-305 (IEC 62305) H/100KA , made of single piece sheet without welds. With stone base for high level of stability. and surge voltage protection. j) Connections & Interconnections by supplying & fixing required size 650/1100 V grade FRLS PVC insulated stranded copper conductor cable, 1.1 kV grade PVC insulated and PVC sheathed armoured aluminium power cables and control cables between solar modules, main power cable to grid supply, PCU unit along with supplying & fixing of necessary channel/conduit, lugs and other accessories etc. as required k) Suitable size copper strips, bare earth conductors, copper earth sockets, earth junction box and all other accessories as required l) Maintenance free Earthing system comprises of molecularly bonded copper of 99.9% tested purity , on low carbon steel of 3m length , having a diameter of 14.2 mm with copper coating thickness of 250 microns with fault current withstand capability of minimum 13 KA rms value for 1 second and I peak of 31 KA. Universal Clamp made of SS 304 for clamping, Clamp should have loosening torque tested report according to IEC 62561. Earth enhancing compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances (TCLP tested) The mineral compound shall be added 25 kg/pit. Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be minimum 250mmx 250mmx 250mm with a weight bearing capacity of 50KN. m) 10mm Copper bonded round conductor from earth electrode directly in ground for ring/direct test joint connection. Copper bonding to be minimum 100 micron coating. Should be tested to IEC 62561 requirements. Should be tested for Electrical resistance after salt mist cyclic test etc from International/National accredited lab , Connection component/Connectors to be SS and should be tested for minimum Lightning current carrying capacity - N/50 kA.
OD307413/2025-2026:Supply installation of reverse power relay and giving connection etc as required.
OD307414/2025-2026:Supply and providing 100/5A , 5VA resin cast metering CT with accuracy class 1 in the existing panel board and giving necessary connection as required.
OD307415/2025-2026:Supply and installation testing and commissionong of 4 pole 160A power contactor and giving connection as required
6.12:Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
6.14:Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
6.15:Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
6.7:Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
6.8:Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD307416/2025-2026:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD307417/2025-2026:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
OD310464/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 3KVA UPS having 60 minutes backup with suitable size of c10 tubular batteries & rack having the following specifications. "a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : ? 10% f) Overall Efficiency : ?87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) UPS make- Numeric/Delta/ Fuji Electric r) battery : Exide/Amaron-Quanta/panasonic or equivalent "
OD307507/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 10 KVA, UPS having 60 minutes backup with suitable size of c10 tubular batteries & rack having the following specifications. "a) 3 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : 0.95 d) Input voltage range : 305V -485V with cut off e) THDi <= 5% f) Overall Efficiency : 94% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave j) Battery over charge & under charge cut off l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) battery : exide / panasonic or equivalent "
OD307510/2025-2026:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB & KSEB - First A3 Sheet
OD307509/2025-2026:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB & KSEB - Each Additional A3 Sheet
OD311110/2025-2026:Supply ,installation,testing and commissioning of 14400 lumen LED, efficacy >=120 Lm/watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD 0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7,CRI>=70 with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Installation of Lift (Electrical work)
Fire Fighting(Electrical work)
18.1.6:a)Supplying,installation,testing and commissioning of Electric driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required : b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC, Synchronous speed 1500rpm suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads 2280 lpm at 56 m head
18.2.6:a)Supplying,installation,testing and commissioning of Diesel Engine driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Diesel Driven Pump) b) Horizontal type, Multi stage ,centrifugal, split Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP ,1500rpm,water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 V Electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1 mm thick Al sheet cladding residential silencer, instruments and protection as per standard specifications, stop solenoid for Auto stop in the event of fault with audio indications, painted with post office red colour etc as required. d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 56 m head
18.3.3:a)Supplying, installation, testing and commissioning of Electric driven Pressurisation Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Jockey Pump) b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC type suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d)M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads180 lpm at 56m Head
OD292608/2025-2026:Supplying, Installation, Testing and Commissioning of electric driven terrace pump suitable for automatic operation and consisting Horizontal type, centrifugal, Mono block pump of cast iron body & CI impeller with stainless steel shaft, mechanical seal and flow of 450 lpm at 20 mtr head confirming to IS 1520, 5 HP SQ cage induction motor monoblock suitable for operation on 415 volts, 3 phase 50 Hz. Common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
OD292613/2025-2026:Supply, installation, testing, commissioning of Expansion bellows with required flanges ,nuts, bolts & accessories. 150 mm
OD292622/2025-2026:Supply, installation, testing, commissioning of Expansion bellows with required flanges , nuts, bolts & accessories. 80 mm
OD292623/2025-2026:Supply, installation, testing, commissioning of Expansion bellows with required flanges , nuts, bolts & accessories. 100mm
OD310823/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x95 sqmm (clamped with 25x3mm MS flat clamp)
OD310824/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x95 sqmm
OD310825/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on cable tray as required. 3.5x70sqmm (clamped with 25x3mm MS flat clamp)
OD310866/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size on wall surface as required 3x16 sqmm (clamped with 1mm thick saddle)
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.8:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)
OD291729/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.25 sq mm - 95 sq mm with 20 mm wide x 1.20 mm thick clip
OD291731/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the 4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip sizes of cables as required.
18.8.1:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 25mm
18.8.2:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 32mm
18.8.3:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 40mm
18.8.4:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 50mm
18.8.5:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 65mm
18.8.6:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 80 mm
18.8.7:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 100 mm
OD311012/2025-2026:Providing, laying, testing and commissioning of C class heavy duty GI Pipe conforming to IS 1239/3589 i/c fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., in ground including welding ,excavation and providing cement concrete blocks as supports, Anti corrosive treatment with coal tar ,Asphalt type as per IS 10221, refiiling the trench etc., of following sizes. 100 mm dia
18.8.8:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 150 mm
OD311025/2025-2026:Providing, laying, testing and commissioning of C class heavy duty GI Pipe conforming to IS 1239, i/c fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., in ground including welding ,excavation and providing cement concrete blocks as supports, Anti corrosive treatment with coal tar ,Asphalt type as per IS 10221, refiling the trench etc., of following sizes150 mm dia
18.15.3:Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.150 mm dia
18.11.1:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:40 mm dia
18.11.4:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:80 mm dia
18.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia
18.11.6:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:150 mm dia
18.14.4:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.80mm dia
18.14.5:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia
18.14.7:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.150mm Dia
18.9.2:Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel
OD291774/2025-2026:HOSE BOX Supply, installation, testing and commissioning of weather proof hose cabinet having the size of 750x500x250mm made of 16 gauge MS Sheet with PCC supports and full front front glass door and locking arrangements suitable to accommodate 2 nos 15m long hose pipes and 1 No. branch pipe. The cabinet shall be painted to scarlet red colour outside and off white inside.
18.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 b) 20 mm nominal internal dia gun metal globe valve &nozzle c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
18.16.2:Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304)
18.25.3:Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200 mm
18.25.4:Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500 mm
18.18.2:Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304)
18.20:supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required.
OD291799/2025-2026:Supplying, fixing, testing and commissioning of 0-15 Kg/sq cm100mm dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per IS specification.
OD291805/2025-2026:Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required.
OD291809/2025-2026:Providing & fixing SS fire brigade for tank filling with coupling (draw-out connection) with nut for female coupling as per IS standards complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank).
18.19.3:Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:3 way-150 mm dia M.S.Pipe
18.23.1:Providing and fixing of flow switch in MS pipe including connection etc as required:100 mm dia
18.23.2:Providing and fixing of flow switch in MS pipe including connection etc as required:150 mm dia
OD292056/2025-2026:Supply, installation, testing and commissioning of Gun metal Air Release valve 20mm dia
18.21.1:Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler
18.21.3:Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler
OD292160/2025-2026:Supply and providing 6Kg ABC Fire Extinguisher cap filled with mono ammonium phosphate powder 50% confirms to IS 1409, stored pressure type, with pressure gauge, the discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, appliccable on A,B & C and electrically started fire, A rating-3A, B rating 21B, construction: deep drawn & co2 mig welded, EPDM rubber hose with both end aluminium clamped, internal coating-epoxy powder coating, external coating-pure polyster powder coating(UV resistant),brass forged valves with safety pin is of ss material, sheet metal thickness ISI approved.
OD292173/2025-2026:Supply and installation of 4.5Kg CO2 fire extinguisher, filled with CO2 gas as per IS 15222, control discharge mechanism fitted with minimum 1.5 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of CO2, discharge time 37 sec, average discharge is 95%, applicable on class B, C and electrcally started fire, external coating is of enamel spray painting, valve confirm to IS 3224 ISI marked, CO2 cylinder construction: hot spinning by seamless pipes & bearing ISI mark, body confirms to IS 7285 extinguishers to ISI marked. fire rating:89B
OD292201/2025-2026:Supply and installation of 5 kg Clean agent fire Extinguisher Modular type of following sizes suitable for below ceiling built in 1 piece with body and bottom. Mild steel body with pressure gauge refillable device and safety release device, Brass valve suitable for B and C classes of fire complete with charge of HFC 236FA/FE36(it is a blend of Hydro Fluoro carbon and organic detossificant essence P 26). The extinguisher shall have pressure gauge for indicationg inside pressure with heat sensitive glass bulb 68 degree with brass forged nozzle and sheet thickness shall not less than 2mm
OD292205/2025-2026:Supply, installation, testing and commissioning of Control Panel of 16 Zone complete with charger, rectifier, alarm display with all other necessary attachments with provision for Public Addressing system and battery back up
17.1.4:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
17.1.7:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
17.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
17.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.
OD292230/2025-2026:Supply, erection, testing and commissioning of PA cum Talk Back speaker wall mounted type .
OD292232/2025-2026:Supply & erecion of MICROPHONE for Intelligible, crisp and bright sound suitable for all type of PA applications. Supplied with quick detachable holder with 3-pin professional XLR connector & 6 mtrs. Twin core shielded low noise cable.
OD292254/2025-2026:Supply & erection of 12V 7 Ah Battery for fire alarm panel & talk Backpanel
OD292272/2025-2026:Supplyand installation, testing and commissioning of 2C x 1.5 Sq.mm twisted pair copper cable ISI marked with proper clamping, supports and terminations..
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
OD292266/2025-2026:Supplyand installation, testing and commissioning of emergency fire escape lighting system consisting 2 nos lamp ,7 AH FMF battary charging unit ,exit sign display etc in MS enclosure
OD292269/2025-2026:SITC of self glowing Fire Escape Route sign board of size 12"x16" made of 3mm thick aluminium sheet layered with photoluminescent material -background colour ,letters and symbols as per IS specifications -IS 12349,IS 9457,IS 12407 either fixed on wall or provided with hanging chains & necessary supports to hang it on ceiling.
OD292270/2025-2026:SITC of self glowing "Fire Assembly point " sign board of size 16"x16" made of 3mm thick aluminium sheet layered with photoluminescent material -background colour ,letters and symbols as per IS specifications -IS 12349,IS 9457,IS 12407 either fixed on wall or provided with hanging chains & necessary supports to hang it on ceiling.
OD292271/2025-2026:SITC of self glowing sign board of size 12" length and 4" to 6" width as per requirement and standard , made of 3mm thick aluminium sheet layered with photoluminescent material -background colour ,letters and symbols as per IS specifications -IS 12349,IS 9457,IS 12407 either fixed on wall or provided with hanging chains & necessary supports to hang it on ceiling.(Fire lift,passenger lift,floor display,electrical duct,main stair,pump room etc)
OD292295/2025-2026:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
OD292296/2025-2026:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Air conditioning(Electrical work)
OD307372/2025-2026:Supply Installation, Testing and Commissioning of cassette type ceiling suspended type cassette air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 415V, 50Hz three phase AC supply, filled with R-410 A refrigerant gas, high energy efficient, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant, copper piping 3m with insulation, control cable up to 5m, 3 m drain pipe, microprocessor control with cordless remote control etc. with one year 4 Nos free service. 3 TR ,5 star -4way 3 phase cassette type type A.C unit,
OD307401/2025-2026:Supply and installation, testing and commissioning of 5.5 TR inverter ductable type Air - conditioner with scroll compressor with R-410 A Refrigerant , 100 % copper suitable for working 3 phase,50 Hz, 415 V AC supply. including cutting the wall for installation, required brackets, and all accessories as required
OD307402/2025-2026:Supply and installation, testing and commissioning of 11.0 TR inverter ductable type Air - conditioner with scroll compressor with R-410 A Refrigerant , 100 % copper suitable for working 3 phase, 50 Hz, 415 V AC supply. including the wall cutting if necessary, wall brackets and all accessories as required.
OD307403/2025-2026:Supply and installation, testing and commissioning of 17.0 TR inverter ductable type Air - conditioner with scroll compressor with R-410 A Refrigerant , 100 % copper suitable for working 3 phase, 50 Hz, 415 V AC supply. including wall cutting if necessary and all accessories etc as required.
OD307404/2025-2026:Supply & laying of Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ19.1 Copper piping(16G/19G) between Indoor & Outdoor units covered with suitable Class O Nitrile Rubber Insulation 13/19 mm thick and Supported with suitable clamps and fittings.
16.12.1.1:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet
16.12.1.2:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet
16.23.1:Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class ""O"") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Nitrile rubber insulation - 25 mm
OD307408/2025-2026:Supply and installation of flexible canvas connection for duct AC unit
16.16:Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required.
16.17:Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.18:Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.6.6.5:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.10 sq mm
90.6.6.6:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.16 sq mm
OD307410/2025-2026:Supply and fixing of 25mm 10Kg/cm2 PVC drain water pipe line with necessary, supports, saddles, clamps -and fittings such as bends, tees etc. are required
Network Switch and Accessories (Electronics Work)
OD291237/2025-2026:Supply and installation of Multi-WAN Gigabit VPN routers with built-in firewalls, 512MB RAM, 256MB Flash, 60K NAT sessions, 2.2Gbps NAT routing and 530Mbps IPSec VPN performance, 2x WAN/LAN 2.5 Gigabit SFP ports, 9x WAN/LAN Gigabit Ethernet ports, IPv4, IPv6, IEEE802.1Q,IEEE 802.1p, IEEE802.1x, IEEE802.3, IEEE 802.3u, IEEE 802.3x,IEEE802.3ab Network Protocols, VLAN, TOS, Support multiple traffic classes, filter by port, IP address, DSCP, and policing, App Qos, VoIP Prioritization QOS, DDNS, Port Forwarding, DMZ, UPnP, Anti-DoS, traffic rules, NAT, ALG, TURN Service, SSL VPN Server / Client-to-Site,IPsec VPN Client-to-Site / Site-to-Site,PPTP VPN Server / Client-to-Site,L2TP Client-to-Site, WireGuard (pending),IPSec Encryption: DES, 3DES, AES,IPSec Authentication: MD5, SHA-1, SHA2-256,IPSec Key Exchange: Main/Aggressive Mode, Pre-shared Key, DH Groups 1/2/5/14,IPSec Protocols: ESP, IPSec NAT Traversal,SSL VPN Encryption: AES, DES,SSL Authentication: MD5, SHA-1, SHA2-256, SHA2-384, SHA2-512,SSL VPN Certificate: RSA,PPTP Encryption: MPPE 40-bit, 128-bit, IPSec,PPTP/L2TP Authentication: MS-CHAPv1/2. Etc. supplied with all necessarya accessories. Preferred Make: Netgear/ Cisco/Aruba/Grandstream or equivalent.
OD291134/2025-2026:Supply and installation of PoE WiFi 6 certified Access point with Dual-band 2x2:2 MUMIMO, Up to 175-meter coverage range, inbuilt controller, supports 256 concurrent Wi-Fi client devices, cloud management,Frequency Bands:- 2.4GHz radio: 2400-2483.5MHz,5GHz radio: 5150-5850MHz, Wi-Fi and System Security:-WEP, WPA/WPA2-PSK, WPA/WPA2 Enterprise (TKIP/AES); WPA3, anti-hacking secure boot and critical data/control lock down via digital signatures, unique security certificate and random default password per device, SSDs:-32 SSIDs total, 16 per radio (2.4ghz and 5 ghz), 2x autosensing 10/100/1000 Base-T Ethernet Ports with IPv4, IPv6, 802.1Q, 802.1p, 802.1x, 802.11e/WMM protocols,QoS:-802.11e/WMM, VLAN, TOS, FCC, CE, RCM, IC Compliance,etc. supplied with all necessary accessories. Preferred Make: Netgear/ Cisco/Aruba/Grandstream or equivalent.
OD290882/2025-2026:Supply and installation of network gigabit manageable L3 switch with 12 Ports Copper 100M / 1G / 10G ports, 12 Ports SFP+ 1G / 10G ports, 480 Gps Switching Fabric, etc. supplied with all necessary accessories. Preferred Make: Netgear XSM4324S or equivalent.
OD290890/2025-2026:Supply and installation of 10G single mode SFP+ module. Preferred Make: Netgear /Cisco/Hp
OD291208/2025-2026:Supply, installation, testing and commissioning of 1m UPC/APC SC/LC Fiber pig tail confirming to LS0H IEC 61034-1 & 2, IEC-60332-1, IEC60754-1 & 2, ISO/IEC 11801-1:2017, ANSI/TIA/ EIA 568.3-D,ANSI/TIA/EIA-492 standards for terminating fiber in LIU/SFP module. Preferred Make: Commscope, Honeywell, Legrand, Molex
OD291211/2025-2026:Supply, installation, testing and commissioning of duplex UPC/APC SC/LC Flange Mount connector with insertion loss 0.02dB or better, RoHS compliant and suitable for existing LIU.Preferred Make: Commscope, Honeywell, Legrand, Molex
OD291212/2025-2026:Supply, installation, testing and commissioning of 1m Duplex UPC/APC UPC/APC SC/LC Fiber patch cord confirming to LS0H, IEC 61034-1 & 2, IEC-60332-1, IEC60754-1 & 2, ISO/IEC 11801-1:2017, ANSI/TIA/ EIA 568.3-D,ANSI/TIA/EIA-492, RoHS standards and suitable for existing SFP module. Preferred Make: Commscope, Honeywell, Legrand, Molex
OD290883/2025-2026:Supply and installation of Layer 3 fully managed stackable 24 Gigabit PoE+ ports with 4 10GBASE-X SFP+ uplinks, 648W of PoE budget, 2 fiber and 2 copper 10G uplink port, etc. preferred Make. Cisco/Hp/Netgear
OD292092/2025-2026:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type Fullyloaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Preferred make: Molex, Honeywell, Commscope,Norden
OD292240/2025-2026:Supply, installation, testing, and commissioning of Modular Wallplate with ABS plastic body, loaded with UL Listed, ETL verified single CAT 6 Keystone Jack , suitable for 22- 24 AWG bare copper conductor,Minimum 500 insertion cycles and 100 reterminations, as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint , spring shutter front access, Protected labelling ,etc on existing metal/PVC box on surface or in recess as required .Preferred Make: Molex, Commscope Honeywell.
OD292233/2025-2026:Supply and Fixing Plastic Modular Surface Box suitable for modular Wallplate on surface with all accessories (86 mm x 86 mm approx.). Preferred Make: Honeywell, Legrand, 3C3 or equivalent
OD290892/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Honeywell, Commscope, Norden
OD290891/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified 2 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint .Preferred Make: Molex,Honeywell, Commscope,Norden
OD290893/2025-2026:Supply and fixing of UL certified 19 inch 9U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, Power Distribution Unit, 8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack
OD290894/2025-2026:Supply and installation of 42U floor standing rack with Conforms to DIN 41494 or equivalent standard, Welded OR CKD (Knock Down) Construction, Lockable Toughened Glass Front Door, Vented Steel Dual Back Door, DIN Standard 10mm Sq. Slots / Direct M6 Tap Equipment Mounting, 19" Mounting angles made of formed steel, Powder Coated finish, Welded to Frame, Vented and Field Cable entry exit cut outs, 2x12 ACDB PDU,etc. preferred Make: D-Link NFR-42U-8080-BL-SK or equivalent.
OD291193/2025-2026:Supply, installation, testing and commissioning of Unloaded 1U Rack mountable LIU Supporting 12LC with splice tray, cable manager and with sufficient blanking plug to cover unused slots.Preferred Make: Molex, Honeywell, Legrand
OD291194/2025-2026:Supply, installation, testing and commissioning of Unloaded 1U/2U Rack mountable LIU Supporting 48LC with splice tray, cable manager and with sufficient blanking plates to cover unused slots. Preferred Make: Commscope, Honeywell, Legrand, Molex
OD294328/2025-2026:Supplying and fixing following size GI box modules for modular wall plates in recess etc as required.1 or 2 Module (86mmX86mm approx)
CCTV and Accessories (Electronics Work)
OD292225/2025-2026:Supply and installation of project series Network Video Recorder, support 64 Channel, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs with a maximum of 4K HD output,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analySupports intelligent analytics such as facial detection, Pedestrian Detection,human detection, vehicle detection,Licence plate recognition,perimeter intrusion, and line crossing statistics ,product must comply with NDAA complaince,Non Black Listed Declaration , Own Mac Address Declaration , Onvif Membership Declaration, Certification: BIS,CE,FCC,ROHS ,ISO:9001; Replacement/Repair warranty for 24 months or more Preferred make: Honeywell /CP Plus/Hanwa or equivalent.
OD292226/2025-2026:Supply and installation of 10TB surveillance hard disk . Preferred Make: Seagate, WD, Toshiba
OD290922/2025-2026:Supply and installation of STQC certified 5MP IP Bullet/Dome Camera with inbuilt mic Image Sensor: 1/2.7 inch 5MP Progressive scan Lens: 3.6mm fixed lens Resolution: 2592(H)×1944(V) or Higher IR Distance: 30 Mtr.,Min illumination 0.003lux @ F1.6(AGC ON),Video Compression: H.265+; H.265; H.264+; H.264; H.264B; MJPEG ,triple Streaming, ONVIF (Profile S/Profile G/Profile T); Smart Detection: Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Micro SD Card Slot up to 256GB, Privacy Mask, ICR auto switch Power Source: 12V DC/PoE Casing: Metal ,Weatherproof Standard: IP67, Certification: BIS-ER,CE,FCC,ROHS ,ISO 9001:20015;Preferred make: Honeywell /CP Plus/Hanwa or equivalent.
OD290925/2025-2026:Supply and Installation of STQC certified 5MP IP Varifocal Bullet/Vandal Dome Camera, Image Sensor: 1/2.7 inch 5MP Progressive scan Motorized Lens: 2.8 ~ 12mm, Resolution: 2880?H?x1620?V) or Higher IR Distance: 30 Mtr or above. Angle of View: Horizontal: 107-34°, Vertical: 55-19°, Diagonal: 134-38°, Min illumination 0.004lux,Video Compression: H.265+; H.265; H.264+; H.264; H.264B; MJPEG ,Video Streaming: Mainstream @30fps,5MP(2880x1620),4MP(2592x1520) 3MP(2304x1296),1080P(1920x1080) 720P(1280x720), Substeam @30fps 720P(1280x720),VGA(640x480),QVGA(320x240), Third stream @30fps VGA(640x480), QVGA?320x240); Motion Detection: 4 zone, Rectangle ; Major Protocols should include most of the following TCP/IP,HTTP,DHCP,DNS,DDNS,RTP/RTSP, SMTP,NTP,UPnP,SNMP,HTTPS,FTP, ONVIF (Profile S/Profile G/Profile T); CGI; Event Trigger: Motion detection, Video tampering, Scene changing, Network disconnection, IP address conflict, Smart Detection:Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection,Advance features: Starlight, WDR(120dB),Micro SD Card Slot up to 256GB, Alarm I/O-1/1, Audio I/O 1/1,Privacy Mask up to 8 level, ICR auto switch Power Source: 12V DC/PoE Casing: Metal ,Weatherproof Standard: IP67,IK10 ; product must comply with NDAA complaince,Non Black Listed , Own Mac Address , Onvif Membership ,(Declaration Should Submit - NDAA,Non Black List,Own Mac Address,Onvif membership), Certification: BIS-ER,CE,FCC,ROHS ,ISO 9001:20015;.Preferred make: Honeywell /CP Plus/Hanwa or equivalent.
OD291217/2025-2026:Supply and installation of 43 inch or above 4K Television suitable for working 24x7, WiFi, Bluetooth, 2 HDMI inputs, etc. supplied with all necessary accessories including wall mounting kit . Preferred Make: LG UR801C, Panasonic, Samsung, Sony.
OD291218/2025-2026:Supply and installation of wireless mouse for NVR. Preferred Make: Dell,HP,Lenovo,Logitech
OD291219/2025-2026:Supply and installation of high speed HDMI cable with 5 meter length, Supports 4K@60MHz, 2160p, 1080p & 3D and Audio Return, 60 Megabytes Per Second Data Transfer Rate, etc. preferred Make: MX or equivalent.
Conference Hall AV System (Electronics Work)
OD290929/2025-2026:Supply and installation of digital discussion control unit with 24-bit/48 kHz digital signal processing (with 12-band feedback suppressor), automated gain control (AGC), mic gain and mic EQ for each connected discussion unit, power and control a total of discussion units, USB storage device recording, Mic/Line ×2, AUX (ST) ×1, INTERPRETATION RETURN ×2 Outputs: Balanced ×4, Unbalanced ×1 LINK /CHAIN : DU A/B Terminals, CU A/B Terminals (DU C/D Terminals) terminals, DC +48V phantom power, etc. supplied with all necessary accessories. Preferred Make: Audio Technica ATUC-50CU or equivalent.
OD290927/2025-2026:Supply and installation of 3 pin goose neck microphone with Fixed-charge back plate, permanently polarized condenser microphone element, Hypercardioid Polar Pattern, 100 - 15,000Hz frequency response, 580mm goose neck length, etc. supplied with all necessary accessories. Preferred Make: Audio Technica ATUC-M58H or equivalent.
OD290958/2025-2026:Supply and installation of dual channel wireless microphone system with Digital 24-bit/48 kHz wireless operation, 2.4 GHz ISM band (2400 to 2483.5 MHz) operating frequency, 60 m operating range, Diversity receiver with Balanced XLR and unbalanced ¼ inch output jacks with level control, supplied with dual hand held transmitters. Preferred Make: preferred Make: ATW-1322(W2) or equivalent.
OD290946/2025-2026:Supply and installation of digital audio mixer with 6 mic/line inputs and 1 unbalanced stereo input, 2 balanced outputs and 1 unbalanced stereo output, USB audio input/output (1 stereo input, 1 stereo output), Remote LED control of ES954 hanging microphone arrays using the GPO terminal, echo canceler for each input channel, Noise cancellation that can be assigned to any output channel, Built-in 4-band EQ and compressor/de-esser for each input channel, Eight 8-band feedback suppressors that can be assigned to mic/line inputs and any output channel, Built-in 12-band PEQ, compressor, and limiter for each output channel, IP Protocol-based external remote control,etc. Preferred Make: Audio Technica ATDM-0604a or equivalent.
OD292264/2025-2026:Supply and installation of Class D Balanced output circuit (BTL) amplifier with 2x 500W at 4Ω, Neutrik speakON NL4 x2, Binding post x2 pairs, 1/4" PHONE(TS) x2 connectors, POWER switch on/off: Output mute; Output voltage protection: Over voltage limiter, user configurable by wattage and speaker preset; DC-fault: Power Supply shutdown protection, etc. preferred Make: Yamaha PX3 or equivalent.
OD290988/2025-2026:Supply and installation of 6 inch ICT Surface-Mount Loudspeaker with 60 Watts continuous, 240 Watts peak power, Multiple transformer taps for 70 V and 100 V line systems or 16 Ohm direct input, weather-resistant to IP65, ABS enclosure, etc.Supplied with all necessary accessories including wall mounting kit preferred Make: Tannoy AMS 6ICT
OD291220/2025-2026:Supply and installation of interactive display with ADS DLED 65 inch display, 16:09 accept ratio, 178°(H/V) Viewing Angle, Android 13.0, 8GB RAM, 128GB ROM, Infrared recognition sensing type, Finger,Passive infrared pen Touch Recognition, 40 Touch Point, ±1.5mm Accuracy, HDMI IN, HDMI OUT, USB 2.0, USB Player (Media) type-C, USB 3.0, TOUCH OUT, VGA IN, AUDIO/MIC IN, AUDIO OUT, SPDIF, BIS, EMC, CE, FCC, UKCA Certifications, etc. supplied with all necessary accessories including wall mounting kit. Preferred Make: Logic LT-IR65FX or equivalent.
OD290966/2025-2026:Supply and installation of OPS suitable for above interactive display with Intel i5 processor, 8GB DDR4 memory, Intel Iris Xe Graphics, NVMe:256GB SSD HDD, 4XUSB3.0, 1XUSB Type-C, 1XRJ45 (10/100/1000M) Ethernet, 1×HDMI (Max resolution 3840×2160 at 30Hz), 2×2.4G/5G Dual frequency antenna, Windows 10 64bit OS, etc. supplied with all necessary accessories. Preferred Make: Logic IS-15L or equivalent.
OD291003/2025-2026:Supply and installation of 4-Port 4K HDMI Splitter with 10.2 Gbps (3.4 Gbps Per Lane) Max. Data Rate, 340 MHzc Max. Pixel Clock, Long distance transmission up to 15 m, 1 x HDMI audio in and 4 x HDMI audio out, etc. supplied with all necessary accessories. Preferred Make: ATEN VS184A or equivalent.
OD291240/2025-2026:Supply, installation, testing and commissioning of Premium / High Speed 10 Metre HDMI Cable Preferred make : MX or equivalent
OD291265/2025-2026:Supply, installation, testing and commissioning of Premium / High Speed 15 Metre HDMI Cable Preferred make : MX or equivalent
Main Auditorium AV(Electronics Work)
OD291077/2025-2026:Supply and installation of digital mixer with 20 analog inputs, 16 mic preamps and 4 line inputs, 12 balanced outputs + phones, 20-tracks sd card play/rec, 24 x 24 CH USB Audio Interface (24-bit/48 kHz), 11 motorized Faders, 5” Touchscreen, AES Digital Output, LAN / WiFi Remote Control, 30 Band GEQ, 8 Band PEQ, etc. preferred Make: RCF M 20X or equivalent.
OD291012/2025-2026:Supply and installation of Active Line array speaker module with 1400 W Peak and 700 W RMS Power output, 1 x 2.0 inch LF driver with 3.0 inch voice coil, 2 x 10 inch HF driver with 2.5 voice coil, 135 dB max SPL, 55 Hz ÷ 20000 Hz frq range, 100 degree Horizontal coverage angle, 15 degree Vertical coverage angle, 800 Hz Crossover Frequencies, Thermal, RMS Protections, Soft Limiter, Cluster, HF, High curving, Indoor Controls PP Composite Cabinet, etc. supplied with all necessary accessories. Preferred Make: RCF HDL20A or equivalent.
OD291016/2025-2026:Supply and Installation of Active Stage Monitor with 800 Watt Peak, 400 Watt RMS power delivery, 127 dB max spl, 10 inch High power neodymium woofer with 2.5 inch voice coil LF driver, 1.7 kapton dome, 1 inch exit neodymium HF driver, DSP processing, floor - fre field equalization, soft limiter and protection, 127 dB max spl, etc. supplied with all necessary accessories. Preferred Make: RCF NX 10-SMA or equivalent.
OD291042/2025-2026:Supply and installation of custom made metal floor stand suitable for placing the subwoofer and the line array speakers with a dimension 560 mm width and 710 mm depth and capable of handling 300KG of weight
OD292145/2025-2026:Supply and fixing XLR trap box with PVC face plate and having 1 XLR Connector with all necessary accessories. Preferred Make: MX or equivalent
OD291052/2025-2026:Supply and fixing of UL certified 19 inch 22U Audio Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, Power Distribution Unit, 8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack
OD291081/2025-2026:Supply and installation of Fixed-charge back plate permanently polarized condenser Cardioid vocal hand held microphone with 40-20,000 Hz frequency range of operation, integral 80 Hz hi-pass filter, etc. supplied with all necessary accessories. Preferred Make: Audio Technica ATM710 or equivalent.
IP-PBX and Accessories(Electronics Work)
OD291638/2025-2026:Supply and Installation of IP PBX With Analog Telephone FXS Ports - 4, PSTN Lin FXO Ports - 4, Users 1000, Concurrent calls 150, Peripheral Ports 1*USB 3.0, 1*SD card interface, Universal Power Supply Input: 100 ~ 240VAC, 50/60Hz; Output: DC 12V, 1.5A. Preferred Make: Grandstream UCM6304 or equivalent.
OD291639/2025-2026:Supply, Install and Configure PoE IP Phone system with all necessary accessories having the following minimum specifications. 1) Dual switched auto-sensing 10/100/1000 Mbps Gigabit Ethernet ports with integrated PoE. 2) 3 SIP accounts, 3 line keys, 4-way conferencing, 3) 2.8 inch (320x240) color-screen LCD. 4) 8 dual-colored BLF/speed-dial keys. 5) Integrated Bluetooth. Preferred Make: Grandstream GXP2130 V2 or equivalent
Cabling (Electronics Work)
OD291185/2025-2026:Supply, laying, and commissioning of Optical Fiber Cable containing 6 core, 9/125μm, OS2 Type outdoor metal free, jel free single mode optical fiber cable , HDPE UV stabilized outer sheath, anti-Rodent, anti-termite and conforming to the standards ISO/IEC 11801, RoHS.
OD291187/2025-2026:Supplying and drawing following sizes of PVC insulated, transparent, multi wire, bright annealed flexible bare electrolytic grade Cu conductor, twin speaker cable in the existing surface/ recessed steel/ PVC conduit as required. 1.5 sq.mm. Preferred Make:-Havells, Polycab, Finolex
OD291190/2025-2026:Supply and laying XLR cable through existing conduit with enough of suitable XLR sockets
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
OD294330/2025-2026:Supplying and drawn of LSZH UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable.Make:- Molex/ Belden/ R&M/ Commscope/Honeywell
OD294331/2025-2026:Supplying and drawn of LSZH UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable.Make:- Molex/ Belden/ R&M/ Commscope/Honeywell
OD294332/2025-2026:Supplying and drawn of LSZH UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable. Make:- Molex/ Belden/ R&M/ Commscope/Honeywell
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.05 MB
viewsbd.pdf
Tender Documents • 13.89 MB
BOQ_1406326.xls
BOQ • 0.96 MB
Download all tender documents and submit your bid