Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹2.3 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.3 CrRejected-Finance 501 SHANTI RESIDENCY II KRUSHNA NAGAR NR NARDAI BRAHM SAMAJ JAMNAGAR 361 006 | JAMNAGAR | GUJARAT | 361006 | ₹2.3 Cr | L2 | Rejected-Finance Other then lowest bidder |
| 3 | L3₹2.4 CrRejected-Finance | ₹2.4 Cr | L3 | Rejected-Finance Other then lowest bidder |
| 4 | L4₹2.5 CrRejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹2.5 Cr | L4 | Rejected-Finance Other then lowest bidder |
| 5 | L5₹2.5 CrRejected-Finance | ₹2.5 Cr | L5 | Rejected-Finance Other then lowest bidder |
| Sl No | Description | Qty | Unit | Badri Electricals L6 | divyarsh entrprise L5 | VIJAY CONSTRUCTION CO L2 | SHELDON CONSTRUCTION L3 | r.s.jain & sons L1 | harsh infrastructure L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing the rubbish outside MD land complete All as specified and as directed by Engg-in-charge | 1,021 | Sqm | 50 ₹51,050 | 75 ₹76,575 | 20 ₹20,420 | 40 ₹40,840 | 20 ₹20,420 | 40 ₹40,840 |
| 2.00 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15 mm in CM 1 : 6 complete all as specified and directed by Eng-in-Charge. | 225 | Sqm | 1,300 ₹2.9 L | 1,515 ₹3.4 L | 850 ₹1.9 L | 900 ₹2.0 L | 950 ₹2.1 L | 1,140 ₹2.6 L |
| 3.00 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including backing coat 10 mm in CM 1:4 complete all as specified and directed by Engr-in-Charge. | 20 | Sqm | 1,400 ₹28,000 | 1,525 ₹30,500 | 900 ₹18,000 | 900 ₹18,000 | 1,000 ₹20,000 | 1,200 ₹24,000 |
| 4.00 | M&L for Glazed ceramic coloured tiles in vertical surface of size 450 x 300 mm, 7-8 mm thick white set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in cm 1 :4 as backing coat, to receive tiles etc complete all as specified & directed by Engr-in-Charge | 351 | Sqm | 1,100 ₹3.9 L | 1,315 ₹4.6 L | 900 ₹3.2 L | 1,000 ₹3.5 L | 925 ₹3.2 L | 1,040 ₹3.7 L |
| 5.00 | M&L for Non skid coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including screed bed 15mm thick in CM (1:6) complete all as specified & directed by Engr-in-Charge | 90 | Sqm | 1,100 ₹99,000 | 1,415 ₹1.3 L | 900 ₹81,000 | 1,100 ₹99,000 | 850 ₹76,500 | 1,100 ₹99,000 |
| 6.00 | M&L for dark shade coloured Vitrified Ceramic tile 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including screed bed 15mm thick in CM (1:6) complete all as specified and directed by Engr-in-Charge. | 310 | Sqm | 1,400 ₹4.3 L | 1,615 ₹5.0 L | 900 ₹2.8 L | 1,200 ₹3.7 L | 1,100 ₹3.4 L | 1,280 ₹4.0 L |
| 7.00 | M&L for dark shade coloured Vitrified Ceramic tile 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including backing coat 10 mm thick in CM 1:4 complete all as specified and directed by Engr-in-Charge. | 25 | Sqm | 1,500 ₹37,500 | 1,625 ₹40,625 | 900 ₹22,500 | 1,150 ₹28,750 | 1,150 ₹28,750 | 1,280 ₹32,000 |
| 8.00 | Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed by Eng-in-Charge. | 8 | X Sqm | 700 ₹5,600 | 255 ₹2,040 | 350 ₹2,800 | 400 ₹3,200 | 150 ₹1,200 | 250 ₹2,000 |
| 9.00 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding, nosing etc complete all as specified and directed by Engr -in-charge | 80 | Sqm | 4,500 ₹3.6 L | 4,899 ₹3.9 L | 4,200 ₹3.4 L | 3,200 ₹2.6 L | 3,000 ₹2.4 L | 1,890 ₹1.5 L |
| 10.00 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by the Engr-in-Charge. | 41 | Cum | 700 ₹28,700 | 455 ₹18,655 | 450 ₹18,450 | 425 ₹17,425 | 500 ₹20,500 | 450 ₹18,450 |
Updated dates
Tender Value
₹2.6 Cr
EMD Value
₹3.4 L
Closing Date
19 Feb 2026, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
ADDN ALTN IMPROVEMENT TO CERTAIN SMQ AND OMQs AT MAKARPURA AF STN VADODARA
2026_MES_747490_1
82292/BRD/E8
Open Tender
Civil Works
450 days
Baroda
As per tender documents
7 documents required · 7 mandatory
₹2,000
GE (AF) Baroda
₹3.4 L
20 Apr 2026
7 Jan 2026
27 Feb 2026
8 Jan 2026
19 Feb 2026
6 Feb 2026
8 Jan 2026 - 29 Jan 2026
Dismantling of floor, hearth or wall tiling including cement mortor bedding (but not backing) removing the rubbish outside MD land complete All as specified and as directed by Engg-in-charge
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15 mm in CM 1 : 6 complete all as specified and directed
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10 mm in CM 1:4 complete all as specified
S&F Glazed ceramic coloured tiles in vertical surface 450 x 300 mm 7-8 mm thick white set and jointed in neat cement slurry and pointed in white cement to match incl 10mm thick rendering in cm 1 :4 as backing coat, to receive tiles etc complete all as specified.
M&L for Non skid coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed 15mm thick in CM (1:6) complete all as specified
M&L for dark shade coloured Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade incl screed bed 15mm thick in CM (1:6) complete all as specified
M&L for dark shade coloured Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10 mm in CM 1:4 complete all as specified and directed
Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding, nosing etc complete all as specified and dircted by engr -in-charge
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified
Material & labour for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in laying of floor, surface finished even and rough to receive floor finishes complete all as specified and directed
M&L for Cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregates) as in 75 mm thick plinth protection , finished surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for cement concete type B-1,1:2:4 mix (using 20 mm graded stone aggregate) as in copings of parapet wall including necessary form work complete all as specified and directed.
M&L for PCC in 1:5:10 type E2 (using 40mm graded agg) as in sunken floor of toilet complete all as specified and as directed by Engineer-in-charge.
Supply & applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg/sqm including cleaning surfaces in sunken portion and laying APP polymer modified fiber glass reinforced membrane 3mm thick of min weight @ 3.5Kg/Sqm (modified bituminous water proofing membrane) with plain polythene finish and sealing all the over laps of 75 mm in length side and 100 mm on the width side of membrane by torching the same all as per manufacturer's instruction's all as specified and as directed by Engg-in-charge
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for.complete all as specified and dircted by engr -in-charge.
M&L for reinforced cement concrete type A1, 1:2:4 ( 20mm graded stone aggregate) in chajjas complete all as specified and dircted by engr -in-charge
M&L for reinforced cement Concrete 1:2:4 type B-1 (nominal mix) (using 20 mm graded stone aggregate) as in slabs sopported on walls beams and columns or in floors complete all as specified and directed
M&L for use and waste of form work to chajjas incl edges as in flat fair finished surfaces all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and dircted by engr -in-charge
M&L for TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hooping for columns, or ren work, hooping ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia complete all as specified and directed by engr-in charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store
S&F 25mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors
Supplying and laying 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fixed complete to wall and ceilings or laid in floors.
S&F 16mm dia Brass Elbow all as specified and as directed by Eng-in-Charge.
S&F 16mm dia Brass Tee all as specified and as directed by Eng-in-Charge.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and dircted by engr -in-charge.
Taking down chowkats or frames (without taking off shutter from the frame) not exc. 1.5 Sqm each complete all as specified and dircted by engr -in-charge
Taking down chowkats or frames (without taking off shutter from the frame) exc. 1.5 Sqm each and not exc 4 Sqm each complete all as specified and dircted by engr -in-charge
M&L for resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and Refixing in same opening incl resecuring or easing & adjusting comlete all as specified
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each comlete all as specified
S&F in repair solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, in opening as per specifications & drawings complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawingspecification and drawing complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed
S&F 35 mm thick factory made flush doors, solid core with prelaminated exterior grade with both side decorative choice lamination with lipping/frame to match incl. all necessary fittings etc complete all as specified and as directed by the Engineer -in-charge.
S&F factory made 2nd class hard wood 35mm glazed and skeleton shutter, open rebated and prepared to receive glass, gauze etc (with vertical sash bars), edges of framing plain, chamfered or rounded,fitted with cut and retired beads for securing glass etc size of membrane of shutter as specified in SSR part I, Section 8, clause 8.20 (a) and fitted to chowkats.
S&F in repair 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete All as specified and as directed by Engg-in-charge
S&F in repair 12mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work such as door shutters etc
S&F 100mm size butt hinges medium weight cold rolled mild steel and fixed (ISI Marked) complete all as specified and dircted by engr -in-charge
S&F in repair continuous piano hinges mild steel bright finish or electrogalvanised width of flap 30mm complete all as specified and directed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor over all length 150mm complete all as specified and as directed by Engg-in-charge
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete All as specified and as directed by Engg-in-charge
S&F 200 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and dircted by engr -in-charge
S&F 150mm long aluminium handles, cast type, anodised complete all as specified and dircted
S&F standard quality door eye viewer with 200 degree lens and easy to install 30mm to 55 mm thick door complete all as specified and directed
M&L for Anodised aluminium frame & shutter (Powder Coated, Min thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including fittings, joining cleat and rubber suitable beeding for fixing etc. complete all as specified and directed
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden beadings complete all as specified complete all as specified and dircted by engr -in-charge
S&F 4.8 mm thick frosted (on one side) sheet glass fixed with and including necessary rubber gasket and aluminium beading all as directed
S&F in repair 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
S&F in repair 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete All as specified and as directed by Engg-in-charge
S&F in repair 200 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and dircted by engr -in-charge
S&F in repair 150mm long aluminium handles, cast type, anodised complete all as specified and dircted
S&F in repair 100mm size butt hinges medium weight cold rolled mild steel and fixed (ISI Marked) complete all as specified and dircted by engr -in-charge
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for 10mm thick rendering on fair faces brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth (without using extra cement) Complete all as specified and as directed
M&L for rendering in two layers (i.e) CM 1:6, 10mm thick as first layer and CM 1:4, 5mm thick as 2nd layer with and including water proofing compund on stone masonry surfaces or surfaces other than fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified
M&L for 5 mm thick rendering on ceiling surfaces of concrete in cement mortar 1:4 finished even and smooth (without using extra cement) including taking down cement plaster on brick or stone walls or concrete surfaces, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash on walls upto 4th floor including cleaning of drops & splashes from window glasses, joinery, electric fittings, wiring etc and cleaning premises complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 61 above but applying three coats of white wash on ceiling surfaces -ditto-
M&L preparation of newly plastered or unplastered wall surfaces and applying two coats of oil bound emulsion distemper (as approved by GE) incl two coats of birla white putty 3 mm thick including necessary priming coat and same be applied only by the authorised applicator of manufacturer(as approved by GE) Complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated surfaces plastered or unplastered on walls including cornices , pilasters by brooming down or steel wire brushing , scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on walls upto 4th floor including cleaning of drops and splashes from window glasses, joinery, electric fittings, wiring etc and cleaning premises clean and tidy complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 64 above but applying one coat of white wash on ceiling surfaces, complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment on wall surfaces by scraping down and washing with water to the satisfaction of Engineer-in-Charge and applying two coats of Oil Bound Emulshion distemper over and including applying 3mm thick wall care white putty (as approved by GE) and to be applied only by the authorised applicater of manufacturer's (as approved by GE) including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment by scraping down completely on brick/stone walls/concrete surfaces thoroughly, rubbing down washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of exterior ACRYLIC Emulshion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturer's instructions complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 67 above but on ceiling surfaces -ditto-.
M&L for preparation of old painted surfaces of wood and wooden based material of any description, not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted surfaces of steel and iron surfaces of any description over 10 CM width or girth and applying one coat of synthetic enamel paint including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed by Engineer-in-Charge.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry in ratio of 1:3 all as per manufacturer's instructions and complete all as specified and as directed
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and dircted
M&L for Welding in repair n exc 2.5cm in length and thickness of metal to be welded exc 6mm and n exc 9mm
M&L for Welding in repair exc 2.5cm and n exc 5cm in length and thickness of metal to be welded exc 6mm and n exc 9mm all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as directed by Eng-in-Charge, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for preparation new or previously untreated steel surfaces of any description not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer incl. cleaning glass,joinery etc. of drop & splashes all as specified and directed by Engr-in-charg.
S&F in repair vitreous china squatting pan water closet ‘orrisa’ pan of size 580x440mm incl. Integral foot rest including cement concrete bedding etc complete all as specified complete all as specified and dircted
S&F in repair bib cock with wall flange,cast copper alloy, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm dia of pipe complete all as specified and dircted
S&F in repair concealed stop cock with adjustable wall flange, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, and fixed for bore 15mm bore of pipe complete all as specified and dircted by engr -in-charge.
S&F in repair Angular stop cock with adjustable wall flange, cast coper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, and fixed for bore 15mm bore of pipe complete all as specified and dircted by engr -in-charge.
S&F in repair Vitreous China wash basin, white, flat back, size 580x450mm (for Hospilal use) including cutting for and pinning in ends of brackets or erecting stand complete all as specified and dircted by engr -in-charge.
S&F in repair pillar taps, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shank and fly-nut, screws for iron pipe and fixed for 15mm dia of pipe complete all as specified and dircted by engr -in-charge
S&F in repair Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15mm dia pipe complete al as specified and as directed by Eng-in-Charge.
S&F in repair PVC connection 15mm dia with PTMT nut of length 450mm long complete all as specified and directed
S & F in repair shower arm 15mm size 195 mm long with bend of 45 degree with flange of PTMT any colour(Min weight 40 gms) complete all as specified and dircted by engr -in-charge
S&F in repair brass chromium plated shower rose 125mm size any colour for fixing with 15mm pipe complete all as specified and dircted
Supply & fixing in repair cast iron nahani trap 75mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4) complete all as specified and dircted by Engr -in-charge
Supply & fixing in repair PVC valve less Symphonic action type flushing cistern, 10 Litre Capacity,white with inlet,ball valve, float and handle incl bracket complete all as specified and dircted by Engr -in-charge
S & F in Repair Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern incl fixing with fushing cistern complete all as specified and dircted by engr -in-charge
S&F in repair grating doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified and dircted by engr -in-charge
S & F in repair Ball valves 25 mm bore high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe & fixed.(Minimum weight15mm-142gms / 20mm-210gms / 25mm-455gms / 40mm-690gms) complete all as specified and dircted by engr -in-charge
S & F in repair Nipple suitable for HDPE water tank 25 mm bore . (mimimum weight 15mm-38gms / 20mm-45gms / 25mm-65gms) complete all as specified and dircted by engr -in-charge
S & F in repair 25 mm bore Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe & fixed complete all as specified and dircted by Engr -in-charge
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws in the wall complete all as specified and directed by Engr-in charge.
S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and dircted by Engr -in-charge
S&F in repair 20mm dia stainless steel tubular curtain rod complete all as specified and as directed by Eng-in-Charge.
S&F in repair brackets for curtain rod ornamental fancy type suitable for fixing matching with curtain rod complete with fixing screws complete all as specified and as directed by Engg-in-charge
S&F in repair single mirror bathroom cabinet moulded body and frame (made of strong and fine quality ABS) with hanged door (Size 16"x12") white in colour make as approved by GE fixed to wall with appropriate rowl plugs complete all as specified and as directed by Engg-in-charge
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by Engg-in-charge
S&F in repair health faucet of approved quality complete All as specified and as directed by Engg-in-charge
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts, and flush pipe) complete all as specified and as directed by Engg-in-charge
S&F in repair stainless steel sinks with drainage board made of stainless steel 01mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specifed and directed
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Dismantling water tanks and removing to store complete all as specified and dircted by engr -in-charge
Cleaning and removing of water tank of capacity exc 500 ltr and n.exc 1000 ltr, all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed
M&L for Injection grouting (acrylic/ epoxy based grout) in all cracks from injection ports, the rate shall including for the following :- (i) Drill at a 45 degree angle with possible to intersect the wall/floor joint. Drilling depth should be half the thickness of the concrete member (ii) Install mechanical injection ports (stainless steel/ brass/ zinc/ plastic) and secure in place at a spacing 150mm c/c to 300mm c/c (iii) Supply of hydrophobic water cut off grout based on MDI (Methylene -Diphenyl-Isocyanate) polyurethane (eg Seal Boss 1510, 1570,1572) . Grout material is to be 100% solvent free and 100% solids (iv) Grouting to be continued till refusal.
M&L for applying bonding coat of modified styrene butadiene emulsion (SBR bonding agent ie. Nitobond SBR 45 or other make mentioned in list of approved make in PS) in proportion (1 bonding agent, 1 water, 3 Cement) by volume with the brushes etc to bind new cement mortar / polymer modified plaster/ concrete/ screed concrete with old surface including removal of loose/ disintegrated old concrete/plaster, surface preparation etc required complete as per manufactures instructions and all as specified Note : Rate quoted shall deemed to be inclusive of proper scaffolding / safety measures and tools etc . Department shall not compromise any deviation on this safety
M&L for taking down existing water proofing treatment (WPT) of any description from roof surfaces incl dismentling of existing PCC/plaster surfaces and roughening of concrete surfaces cleaning and washing down the surfaces with water and removing rubbish to out side MD land as directed by Engr-in-Charge. Note :- Felts and cement plaster/tiles etc shall be measured as one layer only.
M&L for bedding layer/rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixing with & including water proofing compound @3% by wt of cement finished even and smooth (without using exra cement) in sunken portion complete all as specified and as directed by Engg-in-charge
M&L for applying cold bituminous primer @ 0.30 ltr/Sqm confirming to IS-3384 and laying APP polymer modified fiber glass reinforced membrane 3mm thick weight not less than 3.5kg/sqm (modified bituminous water proofing membrane ) with plain finish with polyster base reinforcement, sealing all over with lap of 75mm in length side and 100mm on width side of membrane by torching the same and including applying a coat of bituminous aluminium paint @ 100 gms/sqm all as per manufacturer instructions complete all as specified and directed. Note:- (a) Rate quoted deemed to be inclusive of cleaning of surface to be treated properly to receive the primer and all as directed by the Engr-in-Charge. (b) Necessary guarantee certificate shall be given by contractor for 10 years from the date of completion of work. (c) APP membrane treatment shall be done firstly at corners and junction of parapet wall 30cm on verticle position and 30cm on horizontal position shall be done with proper attention and work carried out by authorised applicator only.Main portion of roof treatment shall be commenced only on completion of corners/ edges/ junctions. (d) APP membrane shall be taken upto outside of the parapet wall to an extent of 150mm minimum. (e) Ensure while laying the treatment no bulging on surface/voids shall be found and proper care/attention be given for the treatment. (f) If any work executed at site without any authorised applicator, the same shall be rejected and no payment shall be made. (g) Contractor shall produce the certificate from the manufacturer for the authorised applicator before commencement of work.
M&L for At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete Job.
M&L for Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete Job.
Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete job.
Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement and no pigment (as in road berm), complete all as specified and as directed by Engr-in-Charge.
M&L for sand cushioning under the interlocking paver block complete all as specified and as directed.
M&L for excavation of post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engr- in- Charge.
M&L Plain Cement concrete type C-2 1:3:6 (using 40mm stone aggregate) as in post holes even and smooth without using extra cement complete all as specified and dircted by engr -in-charge
M&L for Mild Steel for Posts and struts in fencing including cutting top to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc)including all necessory drilling, bolting or riveting etc., and confirming to Fe-290 Gde E-165 complete all as specified and as directed by Engr- in- Charge.
S&F Mild steel screw bolts of dia 5mm to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed by Engr- in- Charge.
Dismantling fencing wire mesh, any type all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
Material only Chain link MS galvanisd fencing, any size or type as directed by Eng-in-Charge.
M&L for precast cement concrete louvres and jallies, 25mm thick Type B0 1:2:4 (12.5mm graded aggregate ) including fixing in cement mortar 1:4 complete all as specified and as directed by Eng-in-Charge.
Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth, for foundation, etc and getting out in soft/loose soil complete all as specified.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified.
Returning , filling in, incl spreading leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified.
M & L for cement concrete 1:4:8 type D 2 using 40 mm .graded stone aggregate as in foundation complete all as specified and directed by engr-in charge.
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but exceeding ashlar facings, dressed stonework and precast concrete articles complete all as specified and dircted by engr -in-charge.
M&L for brick work with sub class B brick straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and dircted by Engr -in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in Cement mortar 1:4 complete all as specified and dircted by engr -in-charge.
S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor all as complete.
S&F in repair 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor all as complete.
S&F 110 mm dia PVC (SWR) bends any length any type.
S&F 75 mm dia PVC (SWR) bends any length any type
S&F 110mm PVC (SWR) branch piece double (double Y) equal or unequl.
S&F 100mm Cowls (with 3 stays), riveted to and including 15 cm length of flue pipes,
Demolition of cement Concrete (Reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for providing precast reinforced cement concrete of type B1 (1:2:4) (using 20 mm graded stone aggregate) set in CM 1:6 as in cover slab complete all as specified and directed.
S&F 200 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete job all as specified and as directed by Eng-in-Charge.
M&L for cement Concrete 1:3:6 type C-2 bed to drain pipes of 200mm dia including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed
Taking down carefully copper/ aluminum point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material to store for keeping in safe custody or for taking credit , and making good disturbed surface of walls, floors, etc to match with existing finishes complete all as specified and directed by Eng-In-Charge.
M&L for point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through metallic rigid / PVC heavy duty concealed conduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories , box made from not less than 1.6mm GI sheet factory made complete all as specified and directed by Eng-In-Charge. for the following.
One light point controlled by one switch complete
One fan point controlled by one switch complete.
One 3 pin socket out let 5 Amps on the independent board.
–do- but one 3 Pin socket out let 5 Amps on the same board.
One bell point controlled by one switch.
Ditto- all as per item No.143 above but with cable of size 2.5 Sq mm PVC insulated on independent board for power plug 15 Amps.complete all as specified and directed by Eng-In-Charge.
Supply & fix ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and directed by Eng-In-Charge.
Supply & fix Lamp holder, insulated body with back plate for batten fitting complete all as specified and directed by Eng-In-Charge.
S&F Modular switch one way 6A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F Modular switch one way 16A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F Modular socket 6/10A-2/3 pin combined 2 Module complete all as specified and directed by Eng-In-Charge.
S&F Modular socket 16/15A-2/3 pin combined 2 Module complete all as specified and directed by Eng-In-Charge.
S&F Modular bell push 6A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F ceiling fan regulator 2M/1M FSC modular type 240 volt complete all as specified and directed by Eng-In-Charge.
Supply and fix in repair MCB DB 12 way vertical sheet metal enclosure TPN 415 volts, 50 Hz with IP-43 protection , double door with 200 Amps standard bus bar of suitable size and comman neutral link all enclosed in standard sheet flush mounting with one MCB SP 6 to 32 Amp as incommer complete all as specified.
S & F in repair door bell ding dong, multi tune, chime and buzzer.
Supply and fixing sheet metal encloure SP with two pin and socket with one single pole MCB 20 Amps, B Curve 240 volts compele all as specified.
Supply and fix in repair MCB, single pole 240 volts 6 to 32 Amps capacity B series in DB's.
Supply and fix in repair MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity B series in DB's.
S&F in repair 10 Watt, LED, T5, Tube light fitting (300 mm) attractive wall mounted type suitable for mirror fitting, all accessories pre wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair on wall / ceiling LED batten lighting fixture 20 Watt LED 5700 K (4') with extruded aluminium heat shrink, integrated elctronic driver and all accessories pre wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
Supply and fix LED security light luminaire 35/36 watt, pressure die cast aluminum housing, heat resistant glass, IP66 protection, better option for uniform distribution complete all accessories pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and directed.
Supply and fixing bracket for security light made up of 25mm dia,1.60m long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete ncluding taking down old unserviceable all as specified and directed.
S & F in repair LED bulb 9 watt 5 star rating.
S & F ceiling fan 1200 mm 5 star rating BLDC Fan metallic white, dust resistant with remote controlled
Supply and fix Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and as directed by Eng-in-Charge.
Supply and fix Exhaust fan, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of 300mm sweep .
M & L for making hole for Exhaust fan of size 300mm with PCC & all B/R work etc all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and directed.
M&L for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as GI strip of 32X6mm size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation&earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
technical_837067.pdf
techsummary_837067.pdf
finance_837067.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_837067.xls
BOQ • 0.41 MB
Tender.pdf
Tender Documents • 1.43 MB
Download all tender documents and submit your bid