| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC C 52 ADG NEI GUWAHATI PRIME APARTMENT FLAT NO 403 GS ROAD CHRISTAN BASTI AMRABATI PATH DISPUR GUWAHATI ASSAM 781005 | GUWAHATI | KAMRUP METROPOLITAN | ASSAM | 781005 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.0 L+₹1.8 L (3.82%)Rejected-Finance NIL | L2 | Rejected-Finance BecomeL2 | |
| 3 | L3₹48.6 L+₹2.4 L (5.16%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance BecomeL3 | |
| 4 | L4₹49.2 L+₹3.0 L (6.48%)Rejected-Finance NIL | L4 | Rejected-Finance BecomeL4 | |
| 5 | Rejected-Technical | - | Rejected-Technical NO As per WLR initiated vide this office letter No 8019/WLR/147/E8 dt 05 Oct 2023 |
Tender Value
Refer Docs
EMD Value
₹95,700
Closing Date
9 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Tezpur
GE South Tezpur, Mission Charlia
PROVISION OF CERTAIN SANCTIONED WORK (PHASE-9) AT SAA UNDER GE (S) TEZPUR
2023_MES_617874_2
8799
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹95,700
Yes
2 Jan 2024
25 Oct 2023
11 Nov 2023
25 Oct 2023
9 Nov 2023
26 Oct 2023
25 Oct 2023 - 1 Nov 2023
Amount
M & L Earthing in replacement of complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate. 3. The cost of taking down old unsv earthing with all its accessories is deemed to be included in the unit price.
Supply and fixing/laying/ inreplacement of connecting and testing of 150.0 Sqmm x 3.50 core LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area.
Supply and fixing/laying/ inreplacement of connecting and testing of 95.0 Sqmm x 3.50 core LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor,1100 volts grade (earthed) cross section area.Complete all as specified and as directed.
Supply and fixing/laying/ inreplacement of connecting and testing of 50.0 Sqmm x 4.0 core LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor,1100 volts grade (earthed) cross section area.Complete all as specified and as directed.
S&F in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35.0 sq mm 3.50 core.Complete all as specified and as directed.
Supply and fixing/laying/ inreplacement of connecting and testing of 25.0 Sqmm x 4.0 core LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area.Complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
M&Land laying natural river clean dry send as cushioning for protection of under ground cable, including spreading and punning down all as per cluase No 3.21 of SSR part-1 complete all as specified and as directed by Engineer-in-charge Note :- Punned thickness of sand layer shall be measured and paid to contractor.
M&L for Brick Sub Class 'B' locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection complete all as specified and as directed.
Labour for horizontal boring of Road/path for cable passing through complete all as specified
Supply and fixing/laying/ inreplacement of galvanised steel water tubing light grade bore of dai 80 mm with all fittings all as site and directed.
Supply and fixing/laying/ inreplacement of galvanised steel water tubing light grade bore of dai 40 mm with all fittings all as site and directed.
Supply and fix in replacement of 4 Pole Power contractor MNX 550 of AMF control of capacity 415 volts 3 phase 50 Hzs 250-500 A, as per IS 13947 ,IEC 60947-4-1, EN- 60947 compete with testing and comissioning complete all as specified and directed.
Supply and fix in replacement of 3 Pole Power Contactors - Type MNX 110 of capacity 415 volts 200A, as per IS 13947 ,IEC -609474 -4-1, EN- 60947-4-1, complete all as specified and directed.
Supply and fix in replacement of Disply control Panel (LED Board) Part No-0300-6088 for 160kva DG set.Complete all as specified and as directed.
M&L and fixing inreplacement of connecting change over switch rating 200 Amps 4 pole, 440 volts grade in sheet metal enclouser conforming to IEC 60947-3, IS/IEC 60947 -3 fixing in panel/ surface of wall on wooden board with making all coonection, gland etc all as site and directed. Make - L&T CO21250OSOO in equivalent Make of seimens/Havells/Legrand
Supply and fix in repairs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position size 1000 ltrs all as specified in SSR Part I.Complete all as specified and as directed.
Supply and fix in repairs Tank Nipple suitable for HDPE water tank. (Minimum weight 20mm- 45gms).Complete all as specified and as directed.
Supply, lay and fix in repairs 25 mm bore galvanized iron water tubing medium grade including all fittings and fixed laid in trenches complete all as specified and directed.
Supply, lay and fix in repairs 20 mm bore galvanized iron water tubing medium grade including all fittings and fixed laid in trenches complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves 20 mm dia, with iron wheel head, screwed both ends for iron pipe and fixed.Complete all as specified and as directed.
Supply and fix Ball valves 20 mm dia high epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 m m - 2 1 0 g m s).Complete all as specified and as directed.
Taking up water pipeline of any size any type including all fittings from trenches mild steel pipe (IS: 1239 Part-I) heavy class with flanged/socket and spigot ends including all fittings viz, forged steel screwed fittings, flanges, bends, tees, reducers, elbow, clamps, hangers etc and kept in safe custody for reuse/disposal /taking credit the same as directed by the Engineer-in-Charge
Supply and lay in trenches / fix to wall MS ERW pipe of 150 mm dia of medium grade with reducer, bends, elbows, union etc complete and connecting to the existing pipe line all as specified
All as in Item No- 30 above but for 100 mm bore
All as in Item No- 30 above but for 80 mm bore
S&F bends (any type, radius and angle) tapers any type (strainght, bend, increasing, decreasing or double socket etc) tee pieces single brancehs 'Y' junction double branch, cross (all socket or socket and spigot) collars, caps and plugs for pipe of Bore upto 150mm. complete all as specified and directed.
Supply, installation, testing and commissioning detectors complying with and type certified to EN-45 addressable type microprocessor based programmable intelligent type multi-sensor heat and smoke combination detector Photoelectric / Optical with base with self built intelligence as per IS:11360 complete all as specified and as directed.
S & F in repair Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed.
S & F in repair Pressure gauge 4"dial 0-14 kgs rating complete all as specified and directed.
S & F in repair Pressure switch Universal type complete all as specified and directed.
S&F of 63 mm dia RRL Hose type 'A' 15 meter long hose conforming to IS-636 complete with male and female coupling conforming to IS-903 including jointing and testing complete all as specified and as directed.
S & F in repair non return Sluice Valve of dia 150 mm Class PN 1.6 complete all as specified and directed.
S & F in repair Sluice Valve of dia 150 mm Class PN 1.6 complete all as specified and directed.
S&F of 80 mm bore hand operated butterfly valve of pressure not less than 15 Kg/Sqcm all as conforming to relevant IS including jointing and testing complete all as specified and as directed.
S&F of hose box made of 18 gauge MS Sheet 800 mm x 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard for keeping 2 Nos. hose pipe of length 15 meter each, non percolating type conforming to IS 636 complete with branch pipe, nozzle 12.5 mm dia, coupling etc. complete all as specified and as directed.
S&F of fire hydrant stand post 80 mm dia GI / MS flanged type, 1.5 Mtr height with provn of single outlet conforming to IS-908 including jointing and testing complete all as specified and as directed.
S&F sprinkler glass bulb type (Standard response) as per IS : 15106/TAC guidelines 68 degree temprature rating pendent type including testing.Complete all as specified and as directed.
S&F of Air cushioning tank (Air vessel) 250mm dia x 1000 mm high with dished top, made of minimum 6 mm thick MS pipe / plate complete with 20 mm dia brass air valve (ball type), 20 mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories all as confirming to relevant IS including testing complete all as specified and as directed.
S&F of Automatic Air Release Valve 50 mm dia suitable for domestic water with 50 mm gun metal stop valve all as confirming to relevant IS including testing complete all as specified and as directed.
S&F in replacement of 63 mm, 3-Inch Gun metal Brass Single headed Fire Hydrant valve ISI Mark all as per Specified and Directed.
Taking down carefully unserviceable point wiring (light,fans,bell,socket etc) complete incl battens and fittings such as switch,socket, ceiling rose,light fittings, regulatos, socket etc and making good disturbed surface of wall/floor etc complete all as specified.
Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc complete as specified.
Taking down MCB SPN DB/TPN DB including MCB any type and and capacity complete all as specified.
M & L for point wiring for one light/fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn through and including PVC concealed with all accessories incl 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity connected to common earth dolly and sunken cast pressed steel terminal box fixed flush to wall of not less than 1.6 mm thick for mounting of fittings such as modular switches, sockets and regulators with Modular PVC flush box and Modular White Cover plate with frame all as specified and directed.
All as per Ser item No.51 above but for one bell point all as directed.
All as per Ser item No.51 above but for 5 amps socket on same board.
All as per Ser item No.51 above but for 5 amps socket on independent board.
All as per Ser item No.51 above but with 2.5 sqmm cables for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Supply and fix of Circuit/Sub Main Wiring with 2x6.0 Sqmm PVC insulated, FRLS, copper cable 1100 volts grade stranded copper conductor cable drawn through and non metallic PVC rigid conduit and conduit accessories, medium grade, ISI marking, concealed including with all fittings and accessories and 1X6.0 Sqmm stranded PVC unsheathed copper cable for earth continuity connected to common earth dolly.Complete all as specified and as directed.
Supply and fix of Circuit/Sub Main Wiring with 2x4.0 Sqmm PVC insulated, FRLS, copper cable 1100 volts grade stranded copper conductor cable drawn through and non metallic PVC rigid conduit and conduit accessories, medium grade, ISI marking, concealed including with all fittings and accessories and 1X4.0 Sqmm stranded PVC unsheathed copper cable for earth continuity connected to common earth dolly.Complete all as specified and as directed.
Supply and fix of Modular switch 1 way 6A, 1 module.Complete all as specified and as directed.
Supply and fix of Modular Bell push 6A 1 module.Complete all as specified and as directed.
Supply and fix of Buzzer, Ding Dong AC. 230 volts, single pole.Complete all as specified and as directed.
Supply and fix of Modular Socket, 6A - 5 pin combined 2 module.Complete all as specified and as directed.
Supply and fix of Modular switch 1 way 16A, 1 module.Complete all as specified and as directed.
Supply and fix of Modular Socket 6A/16A - 5 pin combined 2 module.Complete all as specified and as directed.
Supply and fix in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps all as directed
Supply and fix of ceiling rose surface backelite 65x50 mm having 3 terminals.Complete all as specified and as directed.
S & F of Modular Fan step regulator, 120W - 2 module all as specified and directed
Supply and fix of 9W LED bulb suitable for batten fittings all as directed
Supply and fix of CITY 3 Decorative wall light made up of high grade engineering plastic material suitable for 9 Watt LED bulb including 20 watt bulb all as directed
Supply and fix of Round shape 12 W 220 volts AC, recessed type with high effecience diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed.
Supply and fix of LED light fitting 1X9/1X10W bulkhead luminaires including LED light driver holder including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed.
Supply and Fixing wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 20W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting. Make of Havells cat No.LHEXACP7IN1W020 or equivalent make of Phillips/Havells/CG/surya.
Supply and Fixing wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 10W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting. Make of Havells cat no.LHEXACP7IN1W010 or equivalent make of Phillips/Havells/CG/surya.
Supply and fixing of LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with GI Pipe 40 mm dia bracket made out 120 degree in shape with 2 No GI strip clamps, nut bolts and washers all as directed
S & F MCB DB Single pole and neutral 8 way Double door with 200 amps rated bus bar complete All as specified and directed.
Supply and fixing 6 to 32 amps capacity rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral and current carryingin the MCB DB complete with connection testing and commissioning. Make: Havells/Legrand/L&T/Merlin Gerin/Standard
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.. Make: Havells/Legrand/L&T/Merlin Gerin/Standard
Supply and fixing of 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning completed all as directed. Make: Havells/Legrand/L&T/Merlin Gerin/Standard/HPL Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
M/S N S CONSTRUCTION
SHANKAR ENTERPRISE
M/s. M. G. Babloo Das
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .