| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B BLOCK 21 SHILPI PLAZA REWA DISTT REWA MADHYA PRADESH | REWA | MADHYA PRADESH | 486001 | Admitted-Finance |
Tender Value
₹95.9 L
EMD Value
₹1.9 L
Closing Date
21 May 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM HQ BRIDCUL
BRIDCUL Opp Govt ITI Niranjanpur Saharanpur Road Dehradun
Electrification and Allied works at SDRF Post Sariyapani District Almora 2nd Call
2025_BRID3_83732_1
993/BRIDCUL/964/1/25 Dated 02.05.2025
Open Tender
Electrical Works
Item Rate
540 days
Almora
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹1.9 L
BRIDCUL Dehradun
2 Jul 2025
8 May 2025
21 May 2025
8 May 2025
21 May 2025
14 May 2025
13 May 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as 4 Pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
8 way , Double door for solar
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Triple pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Cable Trays
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply, installation, testing and commissioning of following ennealed tinned electric grade copper conductor PVC insulated and PVC sheathed jelly filled armoured telecommunication cable as per specifications. 10 pair armoured riser cable of 0.60 mm dia copper conductor
20 pair armoured riser cable of 0.60 mm dia copper conductor
Supply and installation, testing and commissioning following size KRONE make telephone tag block in lockable 16 gauge sheet medium duity PVC enclosure complete as required. 10 pair Krone type tag block
20 pair Krone type tag block
Supply of 20 Watt LED Linear Metal Construction commercial batten fitting with fuse protection suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for both surface & suspended Mounting, complete in all respect 2000 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.,
Supply of LED indoor surface downlighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of approx 2000 lumens and maximum system wattage of 15 Watts.power factor >0.95 , THD <10%. he fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply of Exhaust fan 250 mm sweep metal body with 50 HZ 230 volt ac complete with all respective accessories.
L.T PANEL (OUTDOOR TYPE)- Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & outdoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or eqivalent as per approved make list and as direction by engneer in charge. PTTA Panel INCOMER: 1 nos. 250A 415V, Ics=36KA, 4P MCCB with TM release having adjustable O/L, S/C protection. WITH CHANGE OVER SWITCH of 250 A 1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 250/5A. Make : Legrand/ Siemens/ Schneider 1 Set of phase indicating lamp with MCB BUSBAR 250A TPN Bus bar of aluminimum alloy. OUTGOING, 5 nos. 100A 415V, Ics=36KA, 4P MCCB with TM release having adjustable O/L, S/C protection. 4 nos. 63A, 415V, 4P MCB of 10kA ,2 nos. 40A, 415V, 4P MCB of 10kA ,4 nos. 40A, 230V, 2P MCB of 10kA
Networking
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supply and Erecting modular type computer jack RJ 45 with screwless connector approved make with mounting plate and box with wiring connections complete.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
SITC of 8 M.P IP full hd bullet camera complete as required
SITC of NVR 4 Channel 200 mbps 1 sata port complete as required
SITC of 2 TB HDD complete as required
R.J 45 connector
SITC of NVR Rack as required
SITC of POE switch 4 port 200 mbps as required
FIRE ALARM SYSTEM
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
EARTHING AND LIGHTING ARRESTER
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
cable laying
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 2 X 10 sq. mm (19mm)
3½ X 35 sq. mm (32mm)
Erection of metallic/octagonal pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre
Providing and making steel pole collar with cement concrete (1cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 100 mm dia
150 mm dia
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required 150 mm dia
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 2CX10 SQMM AL ARMOURD CABLE
4CX10 SQMM AL ARMOURD CABLE
3.5CX35 SQMM AL ARMOURD CABLE
Supply of LED street light fitting not more than 45 W having System Efficacy >120 lm/W, system output >3600Lumens, THD <10%, Power Factor >0.95, CRI >70, CCT 5700, Full IP 66 ( with out Glue) protected single piece die cast aluminium housing having toughned glass/PC with Impact resistance IK07. LED driver should be Fully metal body Potted & Encapsulated . BIS compliant driver should sustain 440V Stress Voltage protection for 8 Hrs., High Cut off : 325V(+/- 15V) and should have feature of Auto Restart. Driver shall have 4KV Surge protection and feasibility of 10KV external SPD housed in Luminiare and confirming standard IEC60598. Including suitable size GI pipe bracket clamps, nut, bolts and washers complete all as directed.
Supply of 5.0 Mtr Height Galvanized Iron OctagonalPoles having uniformly tapered polygonal shape throughout the length with straightLongitudinal welding in a single shaft. There shall not be any circumferential welding. Dimensions:Top Dia.: 70mm, Bottom Dia.: 130mm, Thickness 3mm &Base plate 200*200*12 mm. Dimension of Foundation Bolts - Length 600mm, Dia. 24mm &04 Nos. Bolts manufactured from special steel along with nuts, washer, anchor plates & Templates. SingleArm of 0.5 Mtr. Shall be provided along with.
Safety Equipments & Accessories
Supplying & laying 1.1 kv grade ISI marked synthetic rubber mats as per specifications of chief electrical inspectorate.
Supplying & fixing of shock treatment chart printed in hindi and english fitted in wooden frame and glass at front side and hard board at back side.
Supplying & fixing in position 1.1 kv rubber hand gloves.
Supplying of first aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS : 2217 - 1963.
Supplying of basic Electrical and mechanical maintenance tool kit as per direction of engineer In charge.
fire works
Supply,installation,testing and commissioning of MS C class Heavy duty pipe Inclueding forged fitting such as bends, tees, reducers,welding rods,two cote red oxide peimer and one cote post office red paint,angle,fastnor,two cote black japan etc. of follow 25mm line (approx.) C Class
32mm line (approx.) C Class
40mm line (approx.) C Class
50mm line (approx.) C Class
65mm line (approx.) C Class
80mm line (approx.) C Class
100 mm line (approx.) C Class
150mm line (approx.) C Class
Supply,installation, testing and commissioning of single headed internal hydrant valve of 63mm dia. Made of SS hydrant valve complete with necessary fitting.
Supply,installation,testing and commissioning of Cast Iron body Butterfly Valve complte with all fitting as requied like MS flange, nut bolts,washers etc. 80 mm
Supply,installation,testing and commissioning of double flanged sluice valve 80 mm
150 mm dia
Supply,installation,testing and commissioning of Cast Iron body Non return valve complte with all fitting as requied like MS flange, nut bolts,washers etc. 80 mm
Supply,installation,testing and commissioning of Cast Iron body 'Y' Strainer complte with all fitting as requied like MS flange, nut bolts,washers etc. 80 mm
Supply,installation, testing and commissioning of RRL Hose pipe with 63mm dia. and 15mtr.length with SS male and female couplings.
Supply,installation,testing and commissioning of swinging type first aid fire hose reel of 20mm internal dia and 30 mtr long with MS drum and 5mm shut of nozzle complete with fitting complete as required.
Supply,installation, testing and commissioning of 63mm dia. SS short branch pipe nozzle suitable for instantaneous connection to hose coupling as required.
Supply,installation, testing and commissioning of two way fire brigade inlet connection suitable for local fire tender complete as required.
Supply,installation,testing and commissioning of air vessel made of 250mm dia
Supplying, Installing, testing & commissioning Sprinklers shall be UL Listed / FM Approved Pendant sprinkler
Supply,installation,testing and commissioning of pressure switch (maximum pressure range 10kg/sq high)for hydrant stand by and jocky pumps, complete as required.
Supplying,Installatoin,Testing,& Commissioning of Terrace pumps of 900 lpm @ 35 mtr head
SITC of 4 zone fire alarm panel complete with batteries
PVC conduit 25 mm dia
Sitc of Hooter/ sounders complete as required.
SITC of Manual call point
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supply,installation,testing and commissioning of Pressure Gauge. (0-10kg).
Supply, installation, testing and commissioning of starter for terrace pumps
Supply,installation,testing and commissioning of gun matel body Ball Valve.25mm dia.
Supply,installation,testing and commissioning of gun matel body air release valve complete with all fitting as equired like ball vlave,holdtite,suta etc.
Supply,installation,testing and commissioning of tank made of galvanized steel Capacity 10,000 Ltr
Connection of terrace tank with existing water supply line
RCC Hole Cutting
Supply,installation of CO2 type fire extinguisher. Capacity. 4.5kg.
Supply,installation of ABC type fire extinguisher. Capacity. 4kg.
Cable 16mm x 4 core aluminium armoured
MS hose box to accommodate 2 no rrl hose and short branch pipe
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant 10 K.W OFF Grid conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Supply, Installation, Testing and Commissioning of 500 LPD SOLAR WATER HEATING SYSTEM conforming to MNRE specifications as amended, with 2 mm thickness lazurite (technology) 58/2100 mm dia tube (35 tubes) with fabrication , 10 year replacement warranty of tank ( for technical fault) with all accessories etc. complete as required.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .