CWE AF Ambala
HQ CWE (AF) Ambala Ambala Cantt-133001
REPAIR / MAINTENANCE OF HT FEEDER, TRANSFORMERS AND ALLIED WORKS IN TECHNICAL AREA AT AF STATION HALWARA UNDER GE (AF) HALWARA
2021_MES_483283_1
CWE/AF AMB/HAL-33/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Halwara
For enlisted in MES Class D and category b ii and for unenlisted refer NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Halwara
₹1 L
Yes
27 Jan 2022
22 Oct 2021
9 Dec 2021
22 Oct 2021
7 Dec 2021
23 Nov 2021
22 Oct 2021 - 6 Nov 2021
Amount
Disconnecting of HT cable & control wiring connections from existing bus bar, disconnecting trolley including servicing of complete parts of VCB, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repair to control wring with single core conductor of existing size as required at site for VCB of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts, re-assembling the same, re-connecting all HT & AC / DC connections to make it functional including testing on existing load complete all as specified and directed.
Disconnecting of HT cable & control wiring connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 3 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 3 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections to make it functional including tesing on existing load complete all as specified and directed.
Description all as per BOQ item No. 2.00 here-in-above but RMU 4 way.
Description all as per BOQ item No. 2.00 here-in-above but RMU 5 way.
Description all as per BOQ item No. 2.00 here-in-above but RMU 6 way. Notes for srl No 1.00 to 5.00: (i) Spare parts shall be measured and paid separately. (ii) Parts replaced shall be identical to those specified by original manufacturer. (iii) Parts of minor nature such as nuts, bolts, screws & washers required at site are deemed to be included in quoted rates. (iv) Servicing of complete parts shall be carried out through OEM/authorized rep of OEM.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as specified & directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified and directed.
M&L in replacement un-reinforced precast concrete cable cover , Class HV type-1, flat, size 300mmx180mmx40mm, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary T&P for passing of LT/HT cables complete all as specified and directed.
S&F in replacement control wiring with 1.5 Sqmm FRLS copper conductor for control curcuit and 2.5 Sqmm FRLS copper conductor for CT circuit as per existing diagram with & including providing ties, beading etc for VCB or RMU complete all as specified & directed.
M&L feeder pillars box out door type made out of MS sheet (CRCA) of thickness not less than 3.15 mm, size 150cm x 65cm x 90cm with copper bus bar strip 3 Nos of size 100 cm in length, 4 cm in width and 6 mm in thickness suitable for 11000 volt grade mounted on HT porcelain insulator, front opening door having two leaf braced with hinged, mounted on 4 Nos angle iron 100mm x 100mm x 8mm, 90 cm long duly welded with box and grouted in PCC 1:3:6 type C-1 using 20 mm graded mechnically crushed stone aggregates block of size 30 cm x 30 cm x 15 cm ,top of box shall be of MS sheet duly bent in shape, tapper with projection of 20 mm on all side, weather / vermin proof with high quality of rubber beading on panel door, cable entry arrangements at bottom includes earthing terminals 2 Nos at both side duly painted with two coat of red stove enamelled paint over & including one coat of compatible primer including taking down/out feeder box as existing at site complete all as specified and directed.
M&L in replacement GI pipe 80 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40mm x 3mm size flat iron including nuts, bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed . Note :- Excavation and earth work shall be measured and paid separately
S&F in replacement cable jointing kit for 11000 volt earthed grade, straight through, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm complete all as specified and directed.
Description all as per BOQ item No. 15.00 here-in-above but size 120sqmm.
S&F in replacement cable jointing kit for 11000 volt earthed grade, indoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 240sqmm complete all as specified and directed.
Description all as per BOQ item No. 17.00 here-in-above but size 120sqmm.
Description all as per BOQ item No. 17.00 here-in-above but size 95sqmm.
S&F in replacement spring charging motor AC/DC of VCB trolly of make & specifications as exist at site complete all as specified and directed.
S&F in replacement spring charging gear assembly for VCB trolly of make & specifications as exist at site complete all as specified and directed.
S&F in replacement motor cut off for spring charging motor of VCB trolly of make & specifications as exist at site complete all as specified and directed.
S&F in replacement power pack with input 220-110 volt AC and output 24volt DC for VCB trolly of make & specifications as existing at site complete all as specified and directed.
S&F in replacement closing coil 24 volt DC for VCB trolly of make & specifications as existing at site after complete all as specified and directed.
S&F in replacement shunt tripping coil 24 volt DC for VCB trolly of make & specifications as existing at site complete all as specified and directed.
S&F in replacement plug & socket assembly for VCB trolly of make & specifications as existing at site complete all as specified and directed.
S&F in replacement CT mounted in epoxy compound with dual ratio 100/50/5 Amps or 200/100/5 Amps with & including making connections with copper wire 2.5 Sqmm and beading, of make & specifications as exist at site for VCB complete all as specified and directed.
S&F in replacement electronic hooter of VCB of make & specifications as exist at site complete all as specified and directed.
S&F in replacement HRC fuse base with HRC fuse 20amp, 415volt, 80 kA of make & specifications as exist at site complete all as specified and directed.
S&F in replacement multifunctional meter for 11 KV VCB of make & specifications as existing at site complete all as specified and directed.
S&F in replacement indicator lamp as per existing colour code for 11 KV VCB/RMU of make & specifications as exist at site complete all as specified and directed.
S&F in replacement ZZ switch, trip circuit healthy of VCB of make & specifications as existing at site complete all as specified and directed.
S&F in replacement air breaker contactor relay of VCB of make & specifications as existing at site complete all as specified and directed.
S&F in replacement common alarm relay voltage range 24-30volt DC of VCB of make & specifications as existing at site complete all as specified and directed.
S&F in replacement microprocessor numerical relay of VCB of make & specifications as existing at site complete all as specified and directed.
S&F in replacement resin encapsulated vacuum interrupter bottle for circuit breaker trolly of 11 KV VCB of make & specifications as existing at site complete all as specified and directed.
S&F in replacement self powered protection relay of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement resin cast ring core protection Current Transformer of ratio 14.4/0.075amp, Class 10P80, VA 0.1 or suitable for relay type W1C1, 50 C/S of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement resin cast ring core metering current transformer of ratio 80/1amp, Class 1.0, VA-2.5, 50C/S of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement digital multifunction meter for 11 KV RMU of make & specifications as existing at site complete all as specified and directed.
S&F in replacement shunt tripping coil of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement live cable LED indicators thru capacitor voltage dividers mounted on the bushings assembly of make & specifications as existing at site complete all as specified and directed
S&F in replacement load break switch mechanism assembly(2PA mechanism without hex rod) having two position spring assisted, Inegrated line earthing switch making capacity complete all as specified and directed. Make: Catpart No. NHP101985R002 of ABB or equivalent in Schneider / CG
S&F in replacement isolator switch mechanism assembly having two position spring assisted, Integrated line earthing switch making capacity complete as per existing sample all as specified and directed. Make: Catpart No. NHP101935R2 of ABB or equivalent in Schneider / CG
S&F in replacement master trip relay as existing complete all as specified and as directed
Supply and filling SF6 Gas of VCB cylinder (9 Kg per cylinder) complete all as specified and as directed. Make: Catpart No. S194-5600-103-17 of ABB or equivalent in Schneider / CG
S&F in replacement wave washers M12 complete all as specified and directed. Make : Catpart No NB336174P567 of ABB or equivalent in Schneider/CG
S&F in replacement spacer 13x16x20mm complete all as specified and directed. Make : Catpart No. NHP403206P1 of ABB or equivalent in Schneider/CG
S&F in replacement clamping Nut M8 x21 complete all as specified and directed. Make : Catpart No. NHP402158P2 of ABB or equivalent in Schneider/CG
S&F in replacement CABLE BUSHING PLATE complete all as specified and directed. Make : Catpart No. 1SNHP304737P1S1 of ABB or equivalent in Schneider/CG.
S&F in replacement Bushing 400 Series bolted type complete all as specified and directed. Make : Catpart No 1NNHP201699R1N1 of ABB or equivalent in Schneider/CG
S&F in replacement O ring 72x6 Bushing 400 Series bolt complete all as specified and directed. Make : Catpart No NHP402076P15 of ABB or equivalent in Schneider/CG
S&F in replacement Rishab complete all as specified and directed Make : Catpart No. Master3430 of ABB or equivalent in Schneider/CG
Supply, laying, jointing, testing and commissioning HT XLPE cable (heavy duty), 11000 volts (earthed), cross sectional area 240 Sqmm, 3 core, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking out/down of old unserviceable HT cable from existing site complete all as specified and directed.
Description all as per BOQ item No. 55.00 here-in-above but cross sectional area 95 Sqmm. Notes for item No. 55.00 & 56.00:- (i) Cable shall be of manufacturing date not earlier than Jun 2021. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately. (iii) No straight through joint shall be permitted in less than single drum length. (iv) The contractor shall produce original purchase vouchers duly machine numbered alongwith excise duty gate pass of factory for verification and record. (v) Cable shall be tested in the presence of rep of Accepting Officer at the factory premises and by the rep of GE/AGE(E&M) after laying in the trenches & before returning filling in the trenches.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 25mm x 4mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe GI light grade 20 mm bore including protection pipe GI light grade 15mm bore, wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 32 mm x 6 mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe light grade GI 20 mm bore including protection pipe GI light grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed. Notes for item 57.00 & 58.00 :- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at No extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L winding of transformer any capacity at HT/LT side with super enamelled copper wire of gauge & weight as exists, varnishing & drying by vaccum impregnating, provinding insulating material, fixing the coil in the position in core assembly and making connection as per original pattern including testing as per latest IS/BIS complete all as specified & directed. Notes: (i) Winding of transformer should be connected with tap changer after completion of winding work. (ii) Transformer shall be tested in front of rep of GE & test results shall be submitted to Engineer-in-charge. (iii) The quantity of winding shall be assesed by BOO.
Dehydration/centrifuging & filling of transformer oil by means Ultra High Vaccum double stage machine to remove impurities from oil such as moisture, dirt, air and other gases at site of installation in running condition of transformer including testing the oil before and after centrifuging from top and bottom of transformer to achieve the BDV value 50KV(rms) & above at 2.5mm air gap complete all as specified and directed. Note:- (i) Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work. (ii) The contractor is required to submit the di-electric repot after dehydration and filtration of each transformer before claiming payment.
Disconnecting HT/LT cables & Earthing connections of burnt /defective transformer of capacity upto 315KVA, 11KV/433 volts, 3 phase, any make/type, from pole/floor mounted, taking down from site of installation carefuly with the help of cranes and transporting the same to workshop for repair, opening, draining out transformer oil, dismantling complete & taking out core assembly & removing burntout windings, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformer including core tank and cooling tubes, removal of damaged parts, dehydrating the core assembly, re-assembling after replacement of damaged parts of the transformer after repairs, making connections and filling dehydradated/fresh transformer oil and testing for all type of tests(routine test & full load test) including transportation back & reinstallation/connection of transformer at site complete all as specified and directed.
Description all as per BOQ item No. 61.00 here-in-above but transformer of capacity 400KVA to 630KVA. Notes for item No. 61.00 & 62.00:- (i) Spare parts shall be measured and paid seperately. All parts/components replaced shall be identical to those specified by original manufacturer. (ii) The labour factor of dismantling/taking out of old winding are included in quoted rates but new winding shall be measured & paid separately. (iii) The draining of old transformer oil is deemed to included in quoted rates but filling new transformer oil and dehydration & refilling of old transformer oil shall be measured & paid separately. (iv) A Board of Officers shall be appointed by the Accepting Officer for ascertaining the repair work required in transformer and all inventory shall be prepared in presence of Engineer-in-charge & Contractor. (v) The transformer shall be repaired at authorized dealer workshop as approved by GE and the cost of this aspect is deemed to be included in quoted rates.
M&L PCC 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete etc complete all as specified & directed.
M&L PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified & directed.
Supply and installation Air break switch, gang operated, triple pole, 11000 volt, 400amp rating, outdoor type for horizontal or vertical operation, mechanically operated, mounted on 12 insulators and steel frame with operating mechanism & operating rod of 25mm bore, medium grade GI pipe from ground level with locking arrangements including making electrical connections to make it functional after testing including dismantling/taking down/out old unservieable air break gang operated switch from two/four pole structure complete all as specified and directed.
S&F cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of zinc oxide primer including dismantling of old unserviceable cross arm as existing complete all as specified and directed.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
S&F in replacement Disc type insulator, porcelain, vitreous 145mm high and 255mm dia, ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Supply & filling transformer oil of dielectric strength not less than 60 BDV to comply IS-335 of 1993 complete all as specified and directed. Note:- (i) Empty container shall become Govt property & shall be taken on charge throrugh receipt voucher. (ii) Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work. (ii) The contractor is required to submit the di-electric repot of each transformer before claiming payment.
S&F in replacement expulsion fuse single pole (drop out fuse) mounted on insulator & steel frame 100 Amps for 11000 Volt grade complete all as specified and directed.
Cleaning and preparation of surfaces of existing feeder pillar box and applying two coats of synthetic enamel paint over & including one coat of red oxide primer including removal of old paint by scratching complete all as specified and directed.
Preparation of external surfaces of existing transformer of capacity 60KVA to 100 KVA for painting including fins/radiators, removal of all existing paint/ rust/oil/grease and unwanted material and applying two coats of synthetic enamel metallic paint, smoke grey, by means of spray gun over & including one coat of red oxide primer at site of installation of transformer including writing SM/MES number, capacity of transformer etc with black synthetic enamel paint complete all as specified and directed.
Description all as per BOQ item No. 72.00 here-in-above but transformer of capacity 160KVA to 250KVA
Description all as per BOQ item No. 72.00 here-in-above but transformer of capacity 315KVA to 400KVA
Description all as per BOQ item No. 72.00 here-in-above but transformer of capacity 500KVA to 630KVA
S&F in replacement 1100 volts, porcelain viterous brown body bushing ,LT,415 volts grade as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and directed.
S&F in replacement 1100 volts, porcelain viterous brown body bushing , LT, 415 volts grade as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and directed.
S&F in replacement 1100 volts, threaded brass bushing rod with nuts, check nuts & washers , LT, 415 volts grade as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and directed.
S&F in replacement 1100 volts, threaded brass bushing rod with nuts, check nuts & washers ,LT,415 volts grade as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and directed.
S&F in replacement 11 KV porcelain viterous brown body bushing insulators for HT side, as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and directed.
S&F in replacement 11 KV porcelain viterous brown body bushing insulators for HT side, as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and directed.
S&F in replacement 11000 volts, threaded brass bushing rod with nuts, check nuts & washers as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and directed.
S&F in replacement 11000 volts, threaded brass bushing rod with nuts, check nuts & washers as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and directed.
S&F in replacement cork sheet for top cover suitable for 50KVA to 315 KVA capacity transformers complete all as specified an directed.
S&F in replacement cork sheet for top cover suitable for 400KVA to 630 KVA capacity transformers complete all as specified and directed.
S&F in replacement breather assembly ISI marked in sealed container suitable upto 315 KVA capacity transformers complete all as specified and directed.
S&F in replacement breather assembly ISI marked in sealed container suitable for 400KVA to 630 KVA capacity transformers complete all as specified and directed.
S&F on wall First Aid Kit box of size 360 mm x 150 mm x 80 mm containing of following items complete all as specified and directed. (a) Dettol bottle100 ml each- 02 Nos (b) Antiseptic Ointment 15 gm-01 No (c) Crocin tablets strip containing 10 Tablets -01 strip (d) Hydrogen peroxide 50 ml -01 bottle (e) Cotten small rolls- 2 Nos (f) Cotten strip small roll -04 Nos (g) Moove tube- 01 No (h) Betadine Tube 15 gm -01 no
S&F shock treatment chart of flex printing for ready reference as a precaution to be used at the time of electric shock for the person working in the sub station for their safety as a first aid including with clear glass cover & wooden frame and fixing on wall complete all as specified and directed.
S&F in replacement Lead acid battery 12 volt, 150 Ah, maintenance free with minimum two year warranty for battery bank complete all as specified and directed.
S&F in replacement lightning arresters gap less metal oxide type consisting of zinc oxide varistors, FRP core and silicon housing with all fittings transmission class discharge capacity 65 kilo amp 11000 volts complete all as specified and directed.
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.
BEHL AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .