| 1 | L1₹5.3 LAccepted-AOC 0701 DISTRICT TREASURY CHENGANNUR | ALAPPUZHA | KERALA | 686534 | L1 | Accepted-AOC Lowest Bidder
Agreement Executed | |
| 2 | L2₹5.6 L+₹28,848 (5.43%)Rejected-AOC HARIPAD VENDOR VIJAYAMMA HARIPAD 690 314 | 690314 | L2 | Rejected-AOC Second Lowest Bidder | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance KERALA KL | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹5.6 L
EMD Value
₹14,017
Closing Date
5 Apr 2025, 4:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
O/o Assistant Executive Engineer,PWD Electrical Subdivision, Civil Station, Alappuzha-688001
Construction of Park junction Bridge across Karippuzhathodu in Kayamkulam LAC-General Electrical Work.
2025_PWD_754775_1
PWD/BLDG/TR/24834/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Karippuzhathodu Kayamkulam
Please refer tender documents.
12 documents required · 12 mandatory
₹1,240
₹14,017
25 Jun 2025
25 Mar 2025
8 Apr 2025
25 Mar 2025
5 Apr 2025
25 Mar 2025
Amount
Electrical Works
OD300508/2024-2025:Supply Installation and Commissioning of Post Top Lantern with symmetric Light. IP65 Rating BGP200 LED26 CW PSU GR CPC SPD, 10kv SPD is provisioned Inside.
OD300509/2024-2025:Supply and providing LED Outdoor Uni Flood light fitting in circular form factor with maximum power consumption of 36 w Fixture shall be supplied with 20-degree beam angles to achieve required spread. The housing shall be made of Pressure diecast aluminum housing with IP68 water proof connectors for fixing inside available space(Philips BBP344 LED 3600/WW 36W 20D 100-240V or approved make)
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
90.12.39.2:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.5.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD249611/2022-2023:Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD210994/2022-2023:Supply and providing 12x3mm brass bolt
OD210995/2022-2023:Supply and providing 25x6mm brass bolt
90.3.17.1:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe
90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD249615/2022-2023:Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board( GS-MB- 3525) and to fix KSEB meters, fuse units, etc as required including fixing it on wall, making good the damages colour washing etc. as required.
OD303202/2024-2025:Supply & installation of dust and vermin proof Syntex junction box(GSJB-1414) including fixing it on octagonal pole, making good the damages etc. as required.
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD249617/2022-2023:Supplying and fixing 240/415 volts, 30A AC1/12A AC3 Power contractor 3Pole with 240V operating voltage in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD249618/2022-2023:Supplying and fixing 24Hr Analog Timer switch with NO/NC operating voltage 230V in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD249619/2022-2023:Supplying and fixing following rating, double pole, 240 volts, MCB type center OFF COS in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD249750/2022-2023:Supplying and fixing Single phase Type 2 Surge protection Device Imax 40KA, In 20KA, Uc 320V Pole 1P+N Up1.5KV in the existing MCB DB complete with connections, testing and commissioning etc. as required.(OBO, L&T, Havells Make)
OD249620/2022-2023:Supply and fixing 32A Cutout Fuse with 16/20/25A HRC Link connection in existing meter board
OD249621/2022-2023:Supply and fixing 32A 2Way neutral link with connection in existing meter board
OD249628/2022-2023:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4Sqmm single run
OD249629/2022-2023:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run
OD249630/2022-2023:Supply and fixing of 32/40mm PVC pipe along with accessories in surface including cutting the wall and making good the same for KSEB Service pipe
OD249639/2022-2023:Dismantling the existing protection barrier from the bridge side, lifting the foot way slab for conduit and re fitting/fixing the same in the same position without damage after erecting the Conduit/Wires/cable/lights and including hire charge for scaffolding for laying cable/conduit in bridge side etc as required
OD249632/2022-2023:Fabrication ,supply and conveyance and installation of name/inauguration board by using granite stone as per the direction of department staff the required names etc. on side wall of foundation cement plaster and making good the surface colour washing etc as required.
Kollamparampil (BID ID -2187767)
Bidder Name
Kollamparampil
DINU CHACKO
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1225603.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .