Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | ₹38.2 L | L1 | Accepted-AOC Bidder is lowest and quoted amount is reasonable. |
| 2 | L2₹41.3 L+₹3.1 L (8.05%)Rejected-Finance | ₹41.3 L+₹3.1 L (8.05%) | L2 | Rejected-Finance L2 |
| 3 | L3₹44.1 L+₹5.8 L (15.2%)Rejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹44.1 L+₹5.8 L (15.2%) | L3 | Rejected-Finance L3 |
| 4 | L4₹44.4 L+₹6.2 L (16.2%)Rejected-Finance NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | ₹44.4 L+₹6.2 L (16.2%) | L4 | Rejected-Finance L4 |
| 5 | L5₹45.6 L+₹7.4 L (19.3%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹45.6 L+₹7.4 L (19.3%) | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | SURESH ELECTRICALS L10 | Sukhi Electricals L6 | vijay infraprojects pvt ltd L3 | JAMNAGAR ELECTRIC AND MACHINERY CO L9 | S t modi L2 | Prime Decor L8 | M/s SK Traders L5 | badri glass and construction L11 | M/s Jagdish Machinery Stores L7 | Nitesh Enterprise L1 | M/s. Ambabhai K patel L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Repair/Maintenance/servicing of ACB any capacity/any type by cleaning the ACB by using air blower, tightening of connection/controls, checking of all fuses, sealing of ACB at bottom, repairing of ACB at bottom, repairing of mechanical parts, oiling/greasing of all moving -parts and carrying out following checks for smooth functioning complete.
(a) Visual Inspection,(b) Checking of funtional locks, interlocks, signaling devices. (c) Checking of suitablility and correct operations of protections, control instruments and electrical connection of the circuit breaker operating mechanism. (d) Checking of Tripping Mechanism operation. (e) checking of standard voltage at PT. (f) Checking of breaker ON/OFF operation manually and electrically. (g) relay setting. (h) Checking of IR value of ACB. | 25 | Each Job | 8,960 ₹2,24,000 | 4,500 ₹1,12,500 | 4,200 ₹1,05,000 | 4,895 ₹1,22,375 | 6,750 ₹1,68,750 | 4,800 ₹1,20,000 | 4,200 ₹1,05,000 | 8,300 ₹2,07,500 | 4,854 ₹1,21,350 | 3,000 ₹75,000 Lowest | 4,470 ₹1,11,750 |
| 2.00 | Supply and fix in repair Neutral CTs for ACB 1000A (NCT ) in existing make complete all as specified and directd | 5 | Each | 5,223 ₹26,115 | 2,500 ₹12,500 | 2,500 ₹12,500 | 2,970 ₹14,850 | 2,250 ₹11,250 Lowest | 3,000 ₹15,000 | 2,500 ₹12,500 | 8,750 ₹43,750 | 2,356 ₹11,780 | 4,000 ₹20,000 | 2,710 ₹13,550 |
| 3.00 | Supply and fix in repair Under Voltage Trip Device (UVT) for ACB 415/220V AC in existing make complete all as specified | 5 | Each | 4,000 ₹20,000 | 4,000 ₹20,000 | 3,800 ₹19,000 | 4,290 ₹21,450 | 2,800 ₹14,000 Lowest | 4,000 ₹20,000 | 3,850 ₹19,250 | 3,500 ₹17,500 | 3,958 ₹19,790 | 4,000 ₹20,000 | 3,920 ₹19,600 |
| 4.00 | Supply and fix in repair spring charging motor for ACB 110V/230V in existing make complete all as specified and directd by Engineer in charge | 7 | Each | 14,960 ₹1,04,720 | 32,000 ₹2,24,000 | 28,000 ₹1,96,000 | 33,550 ₹2,34,850 | 6,800 ₹47,600 Lowest | 31,000 ₹2,17,000 | 29,510 ₹2,06,570 | 15,900 ₹1,11,300 | 30,154 ₹2,11,078 | 25,000 ₹1,75,000 | 30,800 ₹2,15,600 |
| 5.00 | Supply and fix in repair shunt trip closing coil for ACB 110/220V/DC in existing make completer all as specifed and directed by Engineer in charge | 3 | Each | 4,890 ₹14,670 | 2,500 ₹7,500 | 2,500 ₹7,500 | 3,080 ₹9,240 | 2,000 ₹6,000 Lowest | 2,900 ₹8,700 | 2,840 ₹8,520 | 2,400 ₹7,200 | 2,748 ₹8,244 | 4,000 ₹12,000 | 2,820 ₹8,460 |
| 6.00 | Supply and fix in repair main CTs for ACB 1000/1250/1600A in existing make complete all as specified and directed by Engineer in charge | 5 | Each | 2,450 ₹12,250 | 2,700 ₹13,500 | 2,600 ₹13,000 | 3,047 ₹15,235 | 2,100 ₹10,500 Lowest | 2,770 ₹13,850 | 2,650 ₹13,250 | 2,653 ₹13,265 | 2,586 ₹12,930 | 3,000 ₹15,000 | 2,800 ₹14,000 |
| 7.00 | Supply and fix in repair adaptor type terminal for 3pole/4 pole ACB 1000/1250A in existing make complete all as specified and directed by Engineer in charge | 4 | Each | 3,564 ₹14,256 | 3,900 ₹15,600 | 4,000 ₹16,000 | 4,400 ₹17,600 | 2,560 ₹10,240 Lowest | 4,000 ₹16,000 | 4,100 ₹16,400 | 3,400 ₹13,600 | 4,524 ₹18,096 | 4,000 ₹16,000 | 4,050 ₹16,200 |
| 8.00 | Supply and fix in repair adaptor type terminal for 3pole/4 pole ACB 1600A in existing make complete all as specified and directed by Engineer in charge | 3 | Each | 6,890 ₹20,670 | 5,800 ₹17,400 | 5,600 ₹16,800 | 6,336 ₹19,008 | 5,200 ₹15,600 | 5,760 ₹17,280 | 5,780 ₹17,340 | 6,700 ₹20,100 | 8,562 ₹25,686 | 4,000 ₹12,000 Lowest | 5,790 ₹17,370 |
| 9.00 | Supply and fix in repair door inter lock for LT ACB any capacity and make complete all as specified and directed by Engineer in charge | 6 | Each | 2,589 ₹15,534 | 2,400 ₹14,400 | 2,500 ₹15,000 | 2,750 ₹16,500 | 2,000 ₹12,000 Lowest | 2,500 ₹15,000 | 2,450 ₹14,700 | 2,560 ₹15,360 | 2,500 ₹15,000 | 2,500 ₹15,000 | 2,540 ₹15,240 |
| 10.00 | Supply and fix in repair spring charging indication switch for ACB in existing make complete all as specified and directed by Engineer in charge | 6 | Each | 1,000 ₹6,000 Lowest | 1,800 ₹10,800 | 1,400 ₹8,400 | 1,650 ₹9,900 | 1,000 ₹6,000 Lowest | 1,500 ₹9,000 | 1,650 ₹9,900 | 1,350 ₹8,100 | 1,650 ₹9,900 | 1,500 ₹9,000 | 1,530 ₹9,180 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Jul 2026, 6:00 pmClosed
Lt Col Suraj Sadasivan
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR / MAINT OF ACBs, MCCBs WITH CONNECTED ITEMS UNDER GE (AF) JAMNAGAR NO 1
2026_MES_774407_1
8422/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹90,000
Yes
7 Sept 2026
24 Jun 2026
15 Jul 2026
24 Jun 2026
14 Jul 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Repair/Maintenance/servicing of ACB any capacity/any type by cleaning the ACB by using air blower, tightening of connection/controls, checking of all fuses, sealing of ACB at bottom, repairing of ACB at bottom, repairing of mechanical parts, oiling/greasing of all moving -parts and carrying out following checks for smooth functioning complete.
(a) Visual Inspection,(b) Checking of funtional locks, interlocks, signaling devices. (c) Checking of suitablility and correct operations of protections, control instruments and electrical connection of the circuit breaker operating mechanism. (d) Checking of Tripping Mechanism operation. (e) checking of standard voltage at PT. (f) Checking of breaker ON/OFF operation manually and electrically. (g) relay setting. (h) Checking of IR value of ACB. | 25 | Each Job | - | - |
| 2 | Supply and fix in repair Neutral CTs for ACB 1000A (NCT ) in existing make complete all as specified and directd | 5 | Each | - | - |
| 3 | Supply and fix in repair Under Voltage Trip Device (UVT) for ACB 415/220V AC in existing make complete all as specified | 5 | Each | - | - |
| 4 | Supply and fix in repair spring charging motor for ACB 110V/230V in existing make complete all as specified and directd by Engineer in charge | 7 | Each | - | - |
| 5 | Supply and fix in repair shunt trip closing coil for ACB 110/220V/DC in existing make completer all as specifed and directed by Engineer in charge | 3 | Each | - | - |
| 6 | Supply and fix in repair main CTs for ACB 1000/1250/1600A in existing make complete all as specified and directed by Engineer in charge | 5 | Each | - | - |
| 7 | Supply and fix in repair adaptor type terminal for 3pole/4 pole ACB 1000/1250A in existing make complete all as specified and directed by Engineer in charge | 4 | Each | - | - |
| 8 | Supply and fix in repair adaptor type terminal for 3pole/4 pole ACB 1600A in existing make complete all as specified and directed by Engineer in charge | 3 | Each | - | - |
| 9 | Supply and fix in repair door inter lock for LT ACB any capacity and make complete all as specified and directed by Engineer in charge | 6 | Each | - | - |
| 10 | Supply and fix in repair spring charging indication switch for ACB in existing make complete all as specified and directed by Engineer in charge | 6 | Each | - | - |
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
PS.pdf
Tender Documents • 0.85 MB
BOQ_867157.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .