Superintending Engineer
IISER TIRUPATI
Supply, Installation and Commissioning of Split AC units at IISER TIRUPATI Main Campus, Jangalapalli Village, Yerpadu Mandal, Tirupati
2021_ISRTP_625553_1
ISERT/Engg/Elec/20-21/03
Open Tender
Civil Works - Others
Works
20 days
IISER TIRUPATI MAIN CAMPUS YERPEDU
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
THE DIRECTOR IISER
₹45,400
Yes
IISER TIRUPATI
8 May 2021
5 Apr 2021
16 Apr 2021
5 Apr 2021
15 Apr 2021
10 Apr 2021
5 Apr 2021 - 8 Apr 2021
9 Apr 2021
Amount
Supplying, Installation, testing and commissioning of 5 Star, BEE rated (nominal capacity) Air-cooled split type AC unit along complete with indoor unit (IDU), Outdoor unit (ODU), surface / concealed coper Refrigerant piping with insulation (EP Foam pipe section) up to 5 Mtr. (IDU to ODU) copper power cable up to 5 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32/R-410 Refrigerant , PVC drain pipe (dia 15mm) Remote, suitable for , controls suitable to operate on 230 Volts 50 Hz AC supply etc. complete as required including voltage stabiliser of suitable rating to give constant output of 230V for input range of 180 V to 260 V with time delay, high/low cut off, meter to read input and output voltages, ON/OFF switches etc. as required. Quoted price shall include cost of wireless remote controller, cooling thermostat, refrigerant filling with ODU stand. Unit shall be provided with auto timer setting. Minimum filtration to be PM 2.5, Condenser coils should be of copper tubes and hydrophilic type protective aluminium fins. Unit should have a feature of automatic filter cleaning arrangement. As per technical specifications with all the necessary mounting accessories as required for complete installation. The noise level of HI- Wall indoor unit shall not be more than 40 dBA at 1 m distance. Unit should be compatible with central control system for major operating features like temp setting, on /off programming & scheduling etc
1.5 TR SPLIT AC UNITS
2.0 TR SPLIT AC UNITS
Extra for providing Copper Pipe beyond the standard 5Mtr length with standard insulation covered in item 1 above (Size of copper piping should be as per OEM Recommendation)
for 1.5 Ton AC Unit
for 2 Ton Ac unit
General Electricals and Refrigeration
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .