Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹142.1 CrAccepted-AOC | ₹142.1 Cr Quoted ₹142.5 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹150.0 CrRejected-Finance | ₹150.0 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹151 CrRejected-Finance PLOT NO 137 2ND FLOOR AVTAR ENCLAVE PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹151 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹163.1 CrRejected-Finance H NO 8 2 2 1 FLAT NO 203 SITARAMA APARTMENT OPP AXIS BANK PANJAGUTTA HYDERABAD 500 082 | HYDERABAD | TELANGANA | 500082 | ₹163.1 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹179.5 CrRejected-Finance | ₹179.5 Cr | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹116 Cr
EMD Value
₹15 L
Closing Date
7 Mar 2023, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY VISAKHAPATNAM
PROVISION OF MARRIED ACCOMMODATION FOR OFFICERS (156 DUs) AT NORA, VISAKHAPATNAM
2022_MES_529024_3
CE(NAVY)/ VIZ/2022-23
Open Tender
Civil Works
990 days
VISAKHAPATNAM
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINEER P NAVY VISAKHAPATNAM
₹15 L
Yes
1 Feb 2024
6 Feb 2023
9 Mar 2023
6 Feb 2023
7 Mar 2023
21 Feb 2023
Amount
NOTE : Schedule "A" Part I to Part XV are prepriced by MES. Bidders shall insert their lumpsum amount in Green coloured field under col-6 only
Lumpsum price worked out by the contractor for "BUILDING AND STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for " SITE CLEARANCE / AREA DEVELOPMENT / EARTHWORK EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL ", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "AREA DRAINAGE ", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION ", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "ROAD / PATH / HARD STANDING ", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "RETAINING WALL", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM AND FIRE ALARM", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "SOLAR WATER HEATER AND GEYSER", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "DEMOLITION/DISMANTLING ", as listed in Schedule "A" Part – XIV
Schedule "A" Part - XV [Miscellaneous Items]
LIFTS
AVIATION LIGHT
LED Aviation obstruction light with 10 Watt bulb complete including standard fixing arrangements complete all as specified and directed.
Time switches 250 V single phase of 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed.
SOLAR WATER HEATER AND SOLAR PANEL
Supply, Installation, testing and commissioning of 1000 Ltr/ day capacity Solar water Heating system at 60 o C with solar flat plate collectors, complete with 304 grade stainless steel storage tank, insulated with 75 mm thick Poly Urethane Foam (PUF) and supporting frames for solar panels with M.S angle iron of size 40 mm x 40 mm x 4 mm (Nominal size) and for storage tank with 50 mm x 50 mm x 5 mm thick angle iron and 50 mm x 6 mm thick flat iron, painting the metal parts with one coat of metal primer and two coats of synthetic enamel paint of approved brand and shade,required control valves like NRV, strainer and gate valves for storage tank, temperature gauge, including providing suitable cement concrete foundation for supporting stands of solar panels and storage tank complete all as directed and specified.
Supply, Installation, testing and commissioning of 300 Ltr/ day capacity Solar water Heating system at 60 o C with solar flat plate collectors, complete with 304 grade stainless steel storage tank, insulated with 75 mm thick Poly Urethane Foam (PUF) and supporting frames for solar panels with M.S angle iron of size 40 mm x 40 mm x 4 mm (Nominal size) and for storage tank with 50 mm x 50 mm x 5 mm thick angle iron and 50 mm x 6 mm thick flat iron, painting the metal parts with one coat of metal primer and two coats of synthetic enamel paint of approved brand and shade,required control valves like NRV, strainer and gate valves for storage tank, temperature gauge, including providing suitable cement concrete foundation for supporting stands of solar panels and storage tank complete all as directed and specified.
Supply, Installation, testing and commissioning OF Solar Panel powerd inverter (Sine wave) with Battery backup for 8 Hours of capacity 03 KW (single phase 230 Volt, 50Hz, AC supply) complete (offgrid Type) with and incussive of electrical and mechanical accessories & stand for inverter and Batteries, complete all as directed and specified. Note:- (i) Solar panel of specification 320 Wp (minimum) polycrystaline type to be provided. (ii) Invertor and battery backup shall be placed near Lift operator room or near lift store room. (iii) Tublar battery of 12 Volt, 150 AH of suficient quantity to be provided and rate qouted shall deemed to be included the cost of battery. (iv) Manual changeover switch 32 amps single phase , 240 volt, to be provided near inverter for switching on to normal electrical supply incase solar system fails. Material and labour for change over switch is deemed to be included in the rate qouted. (v) Solar inverter supply will feed the supply to light fittings of ground floor parking area, building security lights, passage lights of each floor, staircase lights of each floor and security lights provided in the roof top of the building. (vi) Before carring out the work, contractor shall wiring diagram for approval by Engr-in-Charge.
SITE CLEARANCE / AREA DEVELOPMENT / EARTHWORK EXCAVATION
Earth work in excavation by mechanical means (hydraulic excavator) in all kind of soil over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and lift upto 1.5 m deep, as directed by Engineer-in-charge , complete all as specified and directed.
Earth work in excavation by mechanical means (hydraulic excavator) in all kind of soil over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and lift exc 1.5 m deep and not exc 3.0 deep, as directed by Engineer-in-charge , complete all as specified and directed.
Removing Excavated material [spoil] and depositing where directed (out side MD Land) complete all as specified and as directed.
FIRE FIGHTING SYSTEM AND FIRE ALARM
Ductile Iron pipe with double flanged centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows, bends, reducers, taper pieces, including testing and commissioning (For external Ring main and upto Bldg) complete all as specified and as directed.
Control panel, wall mounted for Booster pump including relays and starter of 12.5 HP for automatic operation of pump with the help of pressure switch including indication lamps, necessary control connections all as specified and as directed.
PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade all as specified and as directed.
Fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 including instantaneous female out let and blank cap made out of SS and GI chain, CI hand wheel complete all as specified and directed.
63 mm dia 15 Mtrs long CP hose confirming to IS:636 complete with male and female coupling conforming to IS-903 including all jointing materials complete all as specified and as directed.
63 mm dia gun metal Branch pipe with 12.5 mm bronze nozzle outlet conforming to IS-903 including all Jointing Materials complete all as specified and as directed
Butterfly valve of size 80 mm dia double flanged type conforming to IS 13905 PN 1.6 complete all as specified and as directed. ( to be provided at booster pump, tapping of wet riser from ring main, fire brigade inlets )
Butterfly valve of size 63 mm dia double flanged type conforming to IS 13905 PN 1.6 complete all as specified and as directed. ( to be provided at booster pump, tapping of wet riser from ring main, fire brigade inlets )
First aid hose reel drum of swing type with hose reel of size not less than 19 mm dia rubber braided hose confirming to IS 884 of 36 mtr length including nozzle complete all as specified and directed.
Fire brigade inlet connection 100 mm dia 4 way, instantaneous type with all accessories, nuts, bolts, gaskets, washers etc complete all as specified and all as directed.
CI sluice valve of 200 mm dia, double flanged conforming to IS 14846 PN 1.6 complete all as specified and as directed. (for yard hydrant sprinkler)
CI sluice valve of 150 mm dia, double flanged conforming to IS 14846 PN 1.6 complete all as specified and as directed. (for yard hydrant ring main)
Butterfly valve of size 65 mm dia double flanged type conforming to IS 13905 PN 1.6 complete all as specified and as directed. ( basement sprinkler branches )
Butterfly valve of size 50 mm dia double flanged type conforming to IS 13905 PN 1.6 complete all as specified and as directed. ( sprinkler branches first floor to 13th floor)
Butterfly valve of size 150 mm dia double flanged type conforming to IS 13905 PN 1.6 complete all as specified and as directed. ( basement sprinkler branches )
Butterfly non-return valve of size 150 mm dia double flanged type conforming to IS 5312-1 (2004) PN 1.6 complete all as specified and as directed.
Y-strainer for Suction, CI, flanged type 150 mm dia conforming to IS 12785(1994), Amendment 04 May 2002 complete all as specified and as directed.
Addressable single action change over type operating system manual call point having an integrally mounted addressable module that monitors and reports contact status all as specified and as directed.
ROAD/ PATH/ HARDSTANDING
Semi Dense Asphaltic Concrete (SDAC) 40 mm consolidated thickness using 5.5 % binder content by weight of total mix with paving bitumen of grade VG-30 and spread, rolled and compacted to required gradient and camber complete all as specified and as directed.
EXTERNAL WATER SUPPLY
100 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with Spigot Socket ends confirming to IS -8329 in standard lengths suitable for Push-On-Rubber Gasket Jointing with inside Cement Mortar Lining and Blak Bitumen external coating and including necessary DI Specials as required, taking down or up DI/CI Pipes and connectings of any description complete all as specifies and as directed. Note:- Earth work and excavation will be measured and paid separately.
Supply and Fix in repairs Gun Metal Globe or Gate Valve of class-I Pressure Testted of 1.5 MPa, 80 mm bore with iron wheel head , screwed both ends for iron pipe, confirming to IS, ISI Marked complete all as specifies and as directed.
Supply only DI specials such as bends (any type, radius and angle ) tapers any type, straight,bend, increasing , decreasing or double socket etc.) tee pieces single branch , "Y" junction , double branch, cross (all sockets or sockets and spigot) collers, caps and plugs upto 150 mm bore complete all as specified and as direcred.
Construction of Valve Chamber of size 900 x 900 x 1200 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with Fly Ash Bricks in Cement Mortar 1:6, 400 mm thick PCC, 1:2:4, Type B1 using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 x 40 x 6 mm size Angle Iron Frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc. removal of surface soil off the premises, demolition of existin Valve Chamber of any description complete all as specified and shown on drawing CEDD/TD/119, Sheet No. 1/1 dated 20 August 1983, revised up to 21 September 1992 complete all as specified and directed.
Supply, Installation and Commissioning of Vertical open well submersible pumpset of capacity 55 KW/75 HP Discharge 2000 LPM , 100 mm delivery size 415 volt, 3 Phase, 50 Hz, 1480 RPM Motor , Horizontal End Suction type, confirming to IS - 12469 with CI Casting Stainless Steel Impeller and Stainless Steel Shaft mounted on heavy duty bearings suitable for continuous operation discharge at 57 metres Head including installation in existing sump, and suitable starter Panel and connecting up with suitable size of copper conductor cable from Starter Panel to Pump complete all as specified and as directed.
Cutting / addition/ alteration / of existing MS / DI / CI pipe lines and inserting suitable size and length of T for taping of 100 mm DI line for further distribution lines etc. complete all as specified and directed.
Boring of holes under road, pavement , hard standing by trenchless technolgy using ultra sounding technique and necessary machine including HDPE pipes of 150 mm dia suitable for 0.4 MPa working pressure complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply, fixing, jointing and testing Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for HT XLPE armoured Aluminium conductor cable of size 300 sqmm and 3 core complete all as specified and as directed.
Supply, laying, jointing and testing of HT UG cable, XLPE insulated, screened, PVC bedded, earthened, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor conforming to IS 7098 (Part II) passing through pipe/duct/trenches/under floor/under road of size 300 sqmm and 3 core complete all as specified and as directed.
Design, Manufacture, Supply, Installation, Testing and Commissioning of 11KV/0.433KV Factory Assembled, Factory Tested ready to install and connections type Compact Substation with an outdoor enclosure in compliance with IEC 62271-202, equipped with 1000 KVA 11kV/433V Cast Resin Transformer, 4 way, 11 KV Ring Main Unit consisting of 2 Nos. 630 A 11kV Manual LBS with Mechanical interlock between 2 LBS and 2 nos. SF6 insulated Vacuum Circuit Breaker and 1600 A Air Circuit Breaker as secondary side control complete with HT Cable interconnection in between Transformer and RMU and suitable sized Busbar between Tranformer and LV incoming Main Switchgear-ACB for full load output current of the transformer and internal earthing connections by GI strips all as a single transport unit and comprising of the following accessories consisting as per details mentioned in ANNEXURE - C of BOQ complete all as specified and as detailed below: NOTE : (i) ANNEXURE - C has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.
Supply and fix wall mounted/ floor mounted,double door ,4 pole MCCB 4 Pole, 415 V,50 KA(ICS=ICU=ICW for 1 Sec), with thermal and magnetic release of capacity 200 Amps, with adjustable type overload protection, short circuit protection, with Encloser made up of CRCA sheet of 2 mm thick front door operated, weather and water proof with necessary locking arrangements along with lugs, cable glands of suitable size for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting cables and the nuts/ bolts etc used are to be made of rust proof material complete with powder coating, necessary internal electric connection as required with LED indicating lamps for each phase all as directed.(to be fixed in Substation of DG Set Isolation) Note : Rates are including of fabrication and installation of bus bar (Aluminium bus abr of capacity 300A minimum) duct and connection it to the bus bar pabel and existiong LT panel.
Automatic Power Factor Correction (APFC) Panel including MCCB/MCB as incomer, relays 300 KVAR with 5 steps (4x50 + 2X25 + 4x12.50) with suitable size of MCBs TP and relays complete all as specified and as directed.
Supply, installation, testing and commisioning of Sandwich Bus bar trunking (BBT) system duly insulated three phase of rating 630 Amps, 3 Phase 4 Wire 100% Neutral IP55 aluminium conductor with Short Circuit breaking capacity of 36kA for 1 sec and comprising of followings: Straight Feeder- 140 Rm 90degree Bend(FABRICATION COST)- RO nos Flange End- 3 Nos End Covers- 3 Nos Bracket Support - 45 Nos Spring Hangers- 45 Nos Copper Braided Flexibles - 3 Set Aluminium External earth-50X6 - 100 Mtrs 160 A Tap-off Box wIth 63 Amps MCCB sandwich type metal box-42
Supply, installation, testing and commisioning of Sandwich Bus bar trunking (BBT) system duly insulated three phase of rating 250 Amps, 3 Phase 4 Wire 100% Neutral IP55 aluminium conductor with Air Insulated type Rising Mains and comprising of followings: Straight Feeder- 47 Rm 90degree Bend(FABRICATION COST)- RO nos Flange End- 3 Nos End Covers- 3 Nos Bracket Support - 15 Nos Spring Hangers- 15 Nos Copper Braided Flexibles - 1 Set Aluminium External earth-50X6 - 280 Mtrs
Bus bar enclosure made of 3.15 mm GI sheet, and iron frammed structure with mounting accessories such as anchor blts etc and 01 nos MCCB 800 Amps 50kA, 4 pole thermal and magnetic release complete all as per specified and as dirercted.
Bus bar enclosure made of 3.15 mm GI sheet, and iron frammed structure with mounting accessories such as anchor blts etc and 01 nos MCCB 250 Amps 36kA, 4 pole thermal and magnetic release complete all as per specified and as dirercted.
Bus bar enclosure made of 3.15 mm GI sheet, and iron frammed structure with mounting accessories such as anchor blts etc and 01 nos MCCB 63 Amps 36kA, 4 pole thermal and magnetic release complete all as per specified and as dirercted.
Supply, laying, jointing and testing of LT UG cable, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor passing through pipe/duct/trenches/under floor/under road of size 300 sqmm and 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing of LT UG cable, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor passing through pipe/duct/trenches/under floor/under road of size 120 sqmm and 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing of LT UG cable, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor passing through pipe/duct/trenches/under floor/under road of size 35 sqmm and 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing of LT UG cable, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor passing through pipe/duct/trenches/under floor/under road of size 25 sqmm and 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing of LT UG cable, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor passing through pipe/duct/trenches/under floor/under road of size 10 sqmm and 3.5 core complete all as specified and as directed.
Supply,installation,testing,comissioning of silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 200 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following accessories consisting as per details mentioned in ANNEXURE - D of BOQ complete all as specified and as detailed below: NOTE : (i) ANNEXURE - D has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.
Earthing complete with galvanised steel earth plate electrode 60cm ×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel using galvanised iron strip 32×6mm and 50 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipe as earthing lead all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
Supply and installation of Steel tubular swaged pole complete with cast iron base plate, finial and single swan neck, bolts, nuts and screws all as specified type 410 SP-31 (9m long) as per IS-2713 (Part-I to III) of 1980 and applying three coats of black bituminous paint through out internally and two coats externally on the portion embedded in concrete and applying two coats of aluminium paint over a coat of zinc chrome primer to the exposed surfaces all as directed including foundation complete all as specified and directed.
Solar street light 50 Watt, smart integrated all in one street light with highest ever system efficiency 170 Lum/Watt, MPPT change contoller, LiFe04 battery, mono crystalline solar panel, PIR motion sensor, easy installation complete all as specified and directed.
Road boading/cutting and making good the disturbed surfaces with the existing road with resurfacing complete all as specifies and as directed.
DEMOLITION AND DISMANTLING
Taking down of bib tap ,pillar tap complete all as specified and directed.
Taking down of stop cock complete all as specified and directed.
Taking down of water tank capacity 225 ltr capacity complete all as specified and directed.
Taking down of water tank capacity 1000 ltr capacity complete all as specified and directed.
Taking down of wooden pelmet boxes complete all as specified and directed.
Taking down of wooden cabinets complete all as specified and directed.
Taking down of flushing cistern of 10 ltr capacity complete all as specified and directed.
Taking down of chain link fencing complete all as specified and directed.
Removing building materials etc. to a out side MD land, beyond the lead included in the rates, including loading, unloading and stacking at the destination for distance of 8 Km complete all as specified and directed
INTERNAL WATER SUPPLY
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for CPVC pipe of size 50 mm bore complete all as specified and as directed
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for CPVC pipe of size 25 mm bore complete all as specified and as directed
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for CPVC pipe of size 15 mm bore complete all as specified and as directed
Stop valves, concealed cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for CPVC pipes of bore dia 15 mm complete all as specified and as directed.
Pillar taps, cast copper alloy, with capstan heads,chromium plated, fancy type, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes of size dia 15 mm complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
Bib taps long body, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down, for size of 15 mm dia complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
Brass CP mixer for mixing hot and cold water screwed down for pipe of size 15 mm dia ,fancy type (two incoming one out going ) complete all as specified and as directed.
Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 15 mm internal dia CPVC pipe complete all as specified and as directed.The maximum flow rate will be 03 LPM
Bib taps two way, chromium plated,fancy type screwed down for size of 15 mm inner dia,CPVC pipes complete all as specified and as directed.The maximum flow rate will be 03 LPM
Health faucet chromium plated, fancy type with steel flexible complete of size of 15 mm dia suitable for CPVC pipes complete all as specified and as directed.The maximum flow rate will be 03 LPM
Swivel shower of PTMT any colour for fixing with 15mm inner dia of CPVC pipe complete all as specified and as directed.The maximum flow rate will be 03 LPM
Shower arm 15mm size 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and as directed.The maximum flow rate will be 03 LPM
Pillar taps, cast copper alloy, with capstan heads,chromium plated, fancy type, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes of size dia 15 mm complete all as specified and as directed. Note: (i) The maximum flow rate will be 06 LPM (ii) This item is considered for each DUs of top floor of each tower/block.
Bib taps long body, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down, for size of 15 mm dia complete all as specified and as directed.. Note: (i) The maximum flow rate will be 06 LPM (ii) This item is considered for each DUs of top floor of each tower/block.
Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 15 mm internal dia CPVC pipe complete all as specified and as directed Note: (i) The maximum flow rate will be 06 LPM (ii) This item is considered for each DUs of top floor of each tower/block.
Bib taps two way, fancy type screwed down for size of 15 mm inner dia,CPVC pipes complete all as specified and as directed. Note: (i) The maximum flow rate will be 06 LPM (ii) This item is considered for each DUs of top floor of each tower/block.
Health faucet chromium plated, fancy type with steel flexible complete of size of 15 mm dia suitable for CPVC pipes complete all as specified and as directed. (i) The maximum flow rate will be 06 LPM (ii) This item is considered for each DUs of top floor of each tower/block.
Swivel shower of PTMT any colour for fixing with 15mm inner dia of CPVC pipe complete all as specified and as directed. (i) The maximum flow rate will be 06 LPM (ii) This item is considered for each DUs of top floor of each tower/block.
Water meter, brass multi jet class screwed type of 32mm dia with and including covered with metal box made out of CRCA sheet 3mm thick of appropriate size with locking arrengment duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
INTERNAL ELECTRIFICATION
Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade,FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concaled including provn of pre fabricated pressed steel terminal box of suitable size made out of 2 mm thick sheets, for mounting modular brackets, including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed for the following :- . (a) One light point controlled by one switch
(b) One bell point controlled by one bell push
(c) One fan (ceiling fan/Ex.fan) point controlled by one switch
(d) One 3 Pin socket outlet 6 amps socket on independent board
All as per item No.100 here-in-before but One 3 pin socket outlet 15/16 amps switch socket out let on independent board with 4 sqmm FRLS PVC insulated, unsheathed,multistarnded wire for phase and neutral one run of 4 sqmm copper cable green in colour for earth continuty conductor complete all as specified and directed. ( Geyser Point control switch of socket shall be provided out side the room)
All as per item No.100 here-in-before but one light point controlled by two Nos two way switches complete all as specefied and directed.
Modular type power socket unit with 20 A MCB, plug top 3 pin type , LED indicator 3/4 module multi purpose complete all as specified and as directed. (for AC)
LED adore lamp for AC 240Volt supply, B22 type,CDS five star, 10 watts of five star rated complete all as specified and as directed.
Ceiling fan, AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod and accessories etc. Min air delivery 210 CFM with service value 6.00 BEE 5 Star rating, with brush less direct current motor (BLDC) metallic body complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and directed.
Exhaust fan 300 mm sweep , (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening ,fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and directed.
Energy efficient LED tube light fitting(mirror optic) with tube 5/6 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Energy efficient LED tube light fitting with tube 9/10 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Energy efficient LED tube light fitting with tube 20 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
LED Security light fitting with tube 30W New generation Energy saving &environmental frindly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc compelte all as specified and as directred.
Submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 4x16sqmm for phase and neutral duly colour coded and 1x16 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(Bus bar trunk/MCCB to VTPN DB of each floor)
Submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 4x10sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( VTPN DB of each floo to 8 way DBof ecah DU)
Submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 2x6sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(AC Wiring for 4 Nos os ACS for each DU)
Submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 2x4.0sqmm for phase and neutral duly colour coded and 1x4.o sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for parking, staire case and common area lighting DB of each floor from lift panel/stand by supply)
Concealed in wall Vertical MCB DB double door type, TPN 6 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixing MCCB TPN 63 amp as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specefied and directed. Note :MCCB and MCBs shall be measured and paid seperately.
Concealed in wall MCB DB. double door type, Triple pole and neutral 8 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, complete all as specified and directed.
Cconcealed in wall MCB DB. double door type, Single pole and neutral 16 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, complete all as specified and directed.
Concealed in wall MCB DB. double door type, Single pole and neutral 4way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, complete all as specified and directed.
MCCB TPN 415V, 50Hz, 16KA of capacity 63 Amp, complete all as specified and directed.
MCB TPN 415V, 50Hz, 16KA of capacity 16 Amp complete all as specified and directed.
MCB SPN 40 Amps 240 Volts, C curve, complete all as specified and directed.
MCB SPN, 32 Amps 240 Volts , 10KA, C curve, complete all as specified and directed.
MCB SPN, 16 Amps 240 Volts , 10KA, C curve,complete all as specified and directed.
MCB SPN, 10 Amps 240 Volts , 10KA, C curve, complete all as specified and directed.
MCB SP, 6 to 32 Amps 240 Volts , 10KA, C curve, complete all as specified and directed.
RCBOs for earth leakage, over load and short circuit protection four pole 100mA, 440 volt of 32 amps rating complete all as specified and directed.
Supply , fixing and commissioning three phase , 3x240 VAC, 50Hz AC supply,4 wired 10 to 60 amps accuracy class 1.0 as per IS 16444 part - I, Pre Paid smart energy meter with 4G/3G/GPRS based communicationmeter for remote reading purpose communication complete all as specified and as directed. NOTE FOR ITEM 130 AND 131: Technical specifications of smart meter mentioned in ANNEXURE-E
Supply , fixing and commissioning Single phase , 1x240 VAC, 50Hz AC supply,2 wired 10 to 60 amps accuracy class 1.0 as per IS 16444 part - I, Pre paid smart energy meter with 4G/3G/GPRS based communicationmeter for remote reading purpose communication complete all as specified and as directed.
Earthing complete with galvanised steel plate electrode 60cmX60cmX3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to GI Strip 25 x 4 mm by means of bolts, nuts and washers all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specefied and directed.
Earth continuity galvanised iron strip of size 25mm x 4mm as earthing lead fixed to wall with and inclussive of GI pipes 32 mm dia light grade for protection of earth strips or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation complete all as specified and directed. ( VTPN DB in each floor of the bldg to be connected to two Nos earthing parallaly)
Telephone socket with and inclussive of prefabricated terminal box and switch plate for fixing telephone socket complete all as specified and directed.
TV socket with and inclussive of prefabricated terminal box and switch plate for fixing TV socket complete all as specified and directed.
Supply and fixing/drawing PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, complete all as specefied and directed. Note : PVC conduit shall be measured seperately, both end of the telephone cable to be taged/marked in colour code sleeves of each qtr number.
Supply and fixing/drawing PVC insulated telephone cable three pair on existing PVC conduits concealed to wall, complete all as specefied and directed. Note : PVC conduit shall be measured seperately, both end of the telephone cable to be taged/marked in colour code sleeves at ground floor and at each floor junction box.
PVC junction box of approx size 10cm x 15 cm rectangular type concealed to wall to accommodate PVC connector of six way for telephone cable on each floor complete all as specified and directed.(for three DUs)
Rigid non metallic PVC conduit of ext dia 20 mm, concealed to wall exclussive of boxes(junction/terminal) but inclussive of all tees,bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hook etc for drawing telephone cable complete all as specified and directed. (for each DUs) Note: Telephone cable shall be measured and paid separately
Rigid non metallic PVC conduit of ext dia 25 mm, concealed to wall exclussive of boxes(junction/terminal) but inclussive of all tees,bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hook etc for drawing telephone cable complete all as specified and directed.. (ground floor to each floor) Note: Telephone cable shall be measured and paid separately
Junction boxes of FRP body of size 15 cm x 10 cm with and including PVC connector three way for telephone cable at each floor complete all as specified and directed.
Junction boxes of FRP body of aprox size 50 cm x 30 cm with and including PVC connector 56 way for telephone cable at ground floor floor complete all as specified and directed.
Rigid non metallic PVC conduit of ext dia 20 mm, concealed to wall exclussive of boxes(junction/terminal) but inclussive of all tees,bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hook etc for drawing TV cable, complete all as specified and directed. (for each DUs)
SEWAGE DISPOSAL & AREA DRAINAGE
PCC solid block masonry with C(5.0) grade solid units having density not less than 18000 kg/sqm as per IS 2185 Part-I, exceeding 10 cm in width and setting in cement mortar CM (1:6), complete all as specified and directed.
Precast reinforced cement concrete slab M-30 using 20 mm graded aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM(1:4) complete all as specified and directed.
LIGHTENING PROTECTION
Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
SCHEDULE 'A' PART-XVI OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 16 AND 17 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of services electrically operated lifts by providing service of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience] for each building/tower comprising of 02 No 08 passanger lifts and 01 No 13 passanger lift for 03 building/towers i.e. total of 03 operstors for 03 building/towers for each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XVII OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 16 AND 17 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of services electrically operated lifts by providing service of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience] for each building/tower comprising of 02 No 08 passanger lifts and 01 No 13 passanger lift for 03 building/towers i.e. total of 03 operstors for 03 building/towers for each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
Notes for item Nos. 147,148, 149, 152, 155 : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
(xiii) The rate quoted by the bidders shall be deemed to be including basic rate [Minimum wages by Government of India/ State Government/ local body, whichever is higher], employers contribution towards Employees Provident Fund [EPF] liability , contribution towards Employees state insurance corporation [EISC], contribution towards Bonus, Overhead and profit and Labour welfare Cess [LWC] as applicable depending upon the manpower requirement. This will create onus on the bidders to ascertain in the relevant rates and quote accordingly. The rates quoted shall be inclusive of all Taxes, Cess, levies as applicable including GST. (xiv) The prevailing Rate/wage/Contribution shall be as applicable on the bid submission end date.
SCHEDULE 'A' PART-XVIII FIRST YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 16 AND 17 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of services electrically operated lifts by providing service of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience] for each building/tower comprising of 02 No 08 passanger lifts and 01 No 13 passanger lift for 03 building/towers i.e. total of 03 operstors for 03 building/towers for each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year after completion of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 06 No of 08 passenger lifts(544 Kgs) to serve G+13 upper floors all as mentioned vide SI No.16 of Sch "A" Phase-I including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 03 no of 13 passenger lifts(884 Kgs) to serve G+13 upper floors all as mentioned vide SI No. 17 of Sch "A" Phase-I including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed
SCHEDULE 'A' PART-XIX SECOND YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 16 AND 17 AFTER COMPLETION OF FIRST YEAR COMPREHENSIVE MAINTENANCE.
Manning and operation of services electrically operated lifts by providing service of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience] for each building/tower comprising of 02 No 08 passanger lifts and 01 No 13 passanger lift for 03 building/towers i.e. total of 03 operstors for 03 building/towers for each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year after completion of Defect liability period complete all as specified and as directed.
All as per description of item No. 150 but second year after completion of work and After completion of first year Comprehensive Maintenance.
All as per description of item No. 151 but second year after completion of work and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XX THIRD YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 16 AND 17 AFTER COMPLETION OF SECOND YEAR COMPREHENSIVE MAINTENANCE.
Manning and operation of services electrically operated lifts by providing service of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience] for each building/tower comprising of 02 No 08 passanger lifts and 01 No 13 passanger lift for 03 building/towers i.e. total of 03 operstors for 03 building/towers for each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 3rd year after completion of Defect liability period complete all as specified and as directed.
All as per description of item No. 150 but third year after expiry of After completion of second year Comprehensive Maintenance.
All as per description of item No. 151 but third year after expiry of After completion of second year Comprehensive Maintenance.
Note for SL No: 150,151,153,154,156,157:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in 06 months complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.
NJR Constructions Private Limited
SHIVALAYA CONSTRUCTION CO. PVT LTD
SHRADHA SABOORI PROJECTS (INDIA) PVT LTD
Som Projects Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid