Loading…
Loading…
Tender ID
Tender Value
₹28.9 L
EMD Value
₹28,864
Closing Date
10 Mar 2026, 5:00 pmClosed
Executive Engineer, Capital Project Division No.3, Gandhinagar
Repairing and rewinding of different size Three phase L.T. Induction motors and Auto transformer (A.T.S.) at Charedi Pumping Station in G.T.S.
282480
Notice No. SK- 16 of 2025-26 (Sr.No.1)
Open
Electrical
Works
Gandhinagar
6 documents required · 6 mandatory
₹1,500
Yes
Executive Engineer, Capital Project Division No.3, Gandhinagar
₹28,864
Yes
3 Mar 2026
3 Mar 2026
3 Mar 2026
10 Mar 2026
3 Mar 2026
Name of Work :-2215-Water supply and sanitation. - 101- Gandhinagar water supply scheme.
Repairing and rewinding of different size Three phase L.T. Induction motors and Auto transformer (A.T.S.) at Charedi
Pumping Station in G.T.S.
BILL OF QUAINTITIES
MEMORANDUM SHOWING THE ITEM OF WORKS TO BE CARRIED OUT
Item Description of Item Quantity Unit Rate In figures Amount
Rewinding of 3 phase 440 volt Kirloskar make
200 H.P. L.T. induction motor stator rewinding
coils complete enamelled duel coated wire, F
class insulation Nomex paper each & every slots.
Fibre glass vages & fibre glass mains cables
provide on main leads cables with new sockets
termination. Dr. Back make F-50 almotherm
varnishing & hardner epoxy also. Scrap wire
material value is deducted. Complete motor
fitting assembled as per original. Motor open &
refitting at site & put into run condition with
necessary manpower, tools and transportation.
Item Description of Item Quantity Unit Rate In figures Amount
Rewinding of 3 phase slip ring 440 volt
Kirloskar make 200 H.P. L.T. induction motor
rotor rewinding by copper flat strips all strips
tapping B class insulation tap F class insulation
Nomex paper each & every slots. Fibre glass
vages & fibre glass mains cables provide on
main leads cables with new sockets termination.
Dr. Back make F-50 almotherm varnishing &
hardner epoxy also. Scrap wire material value is
deducted. Complete motor fitting assembled as
per original. Motor open & refitting at site & put
into run condition with necessary manpower,
tools and transportation.
Item Description of Item Quantity Unit Rate In figures Amount
Rewinding of 3 phase 415 volt 1470 RPM Jyoti
make 180 H.P. L.T. induction motor rewinding
by copper flat strips all strips tapping B class
insulation tap F class insulation Nomex paper
each & every slots. Fibre glass vages & fibre
glass mains cables provide on main leads cables
with new sockets termination. Dr. Back make F-
50 almotherm varnishing & hardner epoxy also.
Mains leads cable fiber glass 70 Sq.mm. copper
cable with new 250 Amp copper socket Scrap
wire material value is deducted. Complete motor
fitting assembled as per original. Motor open &
refitting at site & put into run condition with
necessary manpower, tools and transportation.
Item Description of Item Quantity Unit Rate In figures Amount
Rewinding of 536 H.P. Crompton make
induction motor winding 3 phase 50 c/y, 415-V
988 RPM, Harmetic grade duel coated wire
(Temperature index 200 degree centigrade)
tapping ‘H’ class separation insulation “Nomex”
paper and mica insulation paper best class
sleeve, Dr. Back almotherm make F-50
varnishing etc. complete. and put into the
motor in to working order motor open &
refitting at site & put into run condition with
necessary manpower, tools and transportation.
Supply and fitting of bearing driving at driving
end side for roller bearing No.Nu321-C3 and
non driving end side one is roller NU.218-C3
and second is ball bearing 6218C3 for
Crompton make 600 H.P. L.T. induction motor
and motor bearing driving and non driving end
Supply and fitting of bearing driving at driving
end side bearing No.318 roller bearing and
non driving end side ball bearing 6316-C3 for
Jyoti make 180 H.P. L.T. induction motor and
motor bearing driving and non driving end side.
Item Description of Item Quantity Unit Rate In figures Amount
Supply and fitting of bearing driving at driving
end side roller bearing No.N321 and non
driving end side ball bearing 6319-C3 for
Kirloskar make 200 H.P. L.T. induction motor
and motor bearing driving and non driving end
Oil/ Air Cooled Auto transformer for 536 HP
induction motor panel. 380 V to 440 V and
Output of three tapping in step of 60%, 70%,
80%. All primary and secondary coils windings
complete with super enamel dual coated copper
wire insulation F class, Nomex make paper, fiber
glass separation, dr.back make varnishing and
C40 type cooling oil, new terminal plate with
backalite materials with all new holes for
termination, all bolt stud with wiser “brass
metal” also new replacement etc complete as
per original and put into working order. Scrap
material value is deducted.
Item Description of Item Quantity Unit Rate In figures Amount
Servicing overhauling of 180 H.P. induction
motor complete re-open & stator-rotor coils
servicing, over hauling, cleaning by thinner
wash, Dr. Back make red oxide moisture proof
varnishing, motor H.V. & megger test report etc
complete motor fitting assembled with proper
alignment with pump as per original and put on
foundation in run condition including
transportation.
Servicing overhauling of 200 H.P. induction
motor complete re-open & stator-rotor coils
servicing, over hauling, cleaning by thinner
wash, Dr. Back make red oxide moisture proof
varnishing, motor H.V. & megger test report etc
complete motor fitting assembled with proper
alignment with pump as per original and put on
foundation in run condition including
transportation.
Item Description of Item Quantity Unit Rate In figures Amount
Servicing overhauling of 536 H.P. induction
motor complete re-open & stator-rotor coils
servicing, over hauling, cleaning by thinner
wash, Dr. Back make red oxide moisture proof
varnishing, motor H.V. & megger test report etc
complete motor fitting assembled with proper
alignment with pump as per original and put on
foundation in run condition including
transportation.
Rupees Twenty eight lakhs eighty six thousand three hundred twenty one and paise forty four only.
Executive Engineer,
Capital Project Division No.3
Item Description of Item Quantity Unit Rate In figures Amount
I/We am/are willing to carry out the above work @ ____________ % below/above percent (should be written in figures
and words) of the estimated rates mentioned above Amount of my/our tender works out as under.
Estimated cost put to tender Rs. 28,86,321=44 Estimated cost put to tender Rs. 28,86,321=44
Deduct ___________% below Add__________% above
In words In Words
Note 1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge
for which no extra payment shall be made.
Note 2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
Note 3 GST and Income tax TDS will be deducted at a source while making payments of bills
Note 4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual
mix design the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate
mentioned in all the tender.
Executive Engineer,
Capital Project Division No.3
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
File No.1 E-Tendering Notice.pdf
File No.2 SBD.pdf
File No.3 BOQ .pdf
File No.4 Specification.pdf
File No.5 Condition G.R..pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .