| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical NOT OK |
| 3 | Rejected-Technical | Rejected-Technical NOT OK |
Tender Value
₹86.1 L
EMD Value
₹1.7 L
Closing Date
15 Feb 2025, 4:00 pmClosed
AEE, CIVIL
IWD
Repair and renovation of water proofing treatment to the terrace of AAC building of IISER Kolkata
2025_IISER_846720_1
IISER-K/CIVIL/24-25/28
Open Tender
Civil Works
Item Rate
90 days
IISER KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
A/C NO. 089301000011530
₹1.7 L
28 Feb 2025
30 Jan 2025
17 Feb 2025
30 Jan 2025
15 Feb 2025
30 Jan 2025
Amount
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. : All works above plinth and upto floor V level: Concrete of M25 grade with minimum cement content of 300 kg /cum Note: Extra cement up to 10% ofthe minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
The existing surface to be grinded and cleaned for preparation of the substrate to which the Roller/Brush applied Smart Care Ultron of Asian Paints Roof Deck Coatings system is applied thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically then the surface shall be primed using a two component, fast drying, and high performance solvent based epoxy primer apcoflor HFP 120/130(200gram/Sq.mt); Smart Care Epoxy Primer to improve their adhesion to existing concrete substrate. Coating Application: Providing and applying two- component brush/roller applied high performance, solvent free Hybrid Polyurea polyurethane waterproofing membrane Smartcare Ultron with excellent adhesion, abrasion resistance and durability, based on specially designed advanced polyurea-polyurethane chemical which forms a uniform, elastic, waterproof, vapor permeable sealing layer after application and curing forming a seamless cast in situ membrane providing high Mechanical, chemical, thermal, UV and weather resistance properties at a consumption of minimum 1.65 kg/sqm in 2 coats. Specific Gravity: >1.2 (IS 101) Solid Content: >78% (IS 101) Brookefield Viscosity : 2370 CP (ASTM D 4402) Elongation at break: 600 ± 50% (ASTM D 2370) Tensile strength: 12.6 N /mm2 (ASTM D 2370) Hardness according to SHORE A: 80 (ASTM D 2240) Hardness according to SHORE D: 30 (ASTM D 2240) Adhesive Bond Strength: >3 MPA (ASTM D 4541) Skid Resistance: 45 (ASTM E 274) Crack Bridging Ability: 4.5 mm (ASNZ 4548) Q-UV test for Weathering: >2000 Hours (ASTM G 154) Providing and laying Fiber Mess of 40 GSM sandwiched between two coats of Smartcare Ultron. The Geotextile should be dipped in Ultron first and then fixed onto the first coat of Ultron in tacky condition. A second coat should be applied in order to obtain a fully bonded flexible system.
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. : All works above plinth and upto floor V level: Concrete of M25 grade with minimum cement content of 300 kg /cum Note: Extra cement up to 10% ofthe minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design : In 75x75 mm deep chase
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .