Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.1 LAccepted-Finance | ₹21.1 L | L-1 | Accepted-Finance Lowest |
| 2 | L-2₹21.2 L+₹2,841.31 (0.13%)Rejected-Finance | ₹21.2 L+₹2,841.31 (0.13%) | L-2 | Rejected-Finance Heigher |
| 3 | L-3₹21.2 L+₹3,719.89 (0.18%)Rejected-Finance | ₹21.2 L+₹3,719.89 (0.18%) | L-3 | Rejected-Finance Heigher |
| 4 | Not Admitted-Fee/PreQual/Technical N A | NA | NA | 121004 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
17 Oct 2023, 12:00 pmClosed
EXECUTIVE ENGINEER, RWD, U.S.NAGAR
RURAL WORKS DEPARTMENT, VIKAS BHAWAN, RUDRAPUR
Construction of 02 Additional Class room in GJHS Namuna Bazpur
2023_RES_64281_1
1227/EE/RWD/2023-24dt 04-10-2023
Open Tender
Civil Works - Buildings
Item Rate
270 days
Bazpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
EXECUTIVE ENGINEER, RWD, U.S.NAGAR
₹75,000
19 Oct 2023
10 Oct 2023
17 Oct 2023
10 Oct 2023
17 Oct 2023
10 Oct 2023
Amount
Excavation by mechanical means/ manual means in foundation trench or drain (not Exceeding 1.50 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms lift up to 1.5 m including getting out the excavated soil and disposal of surplus excvated soil as directed with in lead of 50 m. in all kind of soil.
Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:4:8 with cement coarse sand and 40 mm graded stone in foundation.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
B/Work F.P.S. brick of class designation 75 in super structure with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centring and shuttering including shutterings , ropng , etc and removel from foundation footing bases of columns.
Centering and shuttering including shuttering ropping etc. and removel from columns piller piers abutments, post and struts.
Centering and shuttering including shuttering ropping etc. and removel Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including shuttering ropping etc. and removel Suspended floors, roofs, landings, balconies and access platform.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
S/Filling in plinth of local sand under the floor including watering ramming consolidation & dressing Complete
12 mm thick cement plaster 1:6 cement & sand mortar including supply of all labour material andT&P etc required for proper complition of work.
15 mm thick cement plaster 1:6 cement & sand mortar on rough side including supply of all labour material andT&P etc required for proper complition of work.
Reinforcement for R.C.C. work including straightening, cutting , bending, placing, in postion and binding all comlete for Thermo Mechanically treated bars.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
Providing and fixing T-iron frames for doors, windows and ventilato mild steel Tee-sections, joints mitred and welded with 15x3 10cm long embedded in cement concrete blocks 15x10x10 cm of 1 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm no size) or with wooden plugs and screws or rawl plugs and screws or dash fastener or with fixing clips or with bolts and nuts as including fixing of necessary butt hinges and screws and app priming coat of approved steel primer.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :.Two or more coats on new work
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per anufacturer’s specification. Two or more coats on new work
Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:2:4 with cement coarse sand and 20 mm graded stone in foundation.
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete
Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nuts and washers etc. complete.
Providing and fixing aluminium hanging floor door stopper ISI mar (anodic coating not less than grade AC 10 as per IS : 1868) transp required colour and shade with necessary screws etc. complete.
Providing and fixing aluminium handles ISI marked anodised (anod less than grade AC 10 as per IS : 1868) transparent or dyed to req shade with necessary screws etc. complete :
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete For 250 mm
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete For 150 mm
Providing and fixing M.S. holder bat clamps of approved design to water pipes embedded in and including cement concrete blocks 10 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 2 and cost of cutting holes and making good the walls etc.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and fixing of ISI marked 35 mm thick flush door shutter Confirming ti IS:2202 (Part-1) decorative bord construction with frame of Ist class hard wood and well matched commercial 3 ply venering with vertical grain or cross band face veneers on both face of shutter.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
HARISH CHANDRA KANDPAL
Kayum Ali
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .