Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹39.6 L+₹16,794.20 (0.43%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹40.4 L+₹1.0 L (2.56%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹41.1 L+₹1.7 L (4.30%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹46.6 L+₹7.2 L (18.2%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Jun 2023, 5:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR REPLACEMENT OF LT PANEL STARTER XLPE CABLES AND SERVICING OF DG SET AT SEWAGE INSTALLATIONS UNDER GE UTILITY AMBALA CANTT
2023_MES_590147_2
CA NO GE U AMB T 24 OF 2023-24
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹96,000
26 Jun 2023
29 May 2023
21 Jun 2023
29 May 2023
19 Jun 2023
5 Jun 2023
29 May 2023 - 1 Jun 2023
Amount
Servicing/Repair of DG set capacity 160/125 KVA from authorised Service Centre of existing make Removing tappet cover and cylinder heads from DG set, grinding and polishing of cylinder heads, grinding of valve sets, grinding of inlet and exhaust valve after fixing new seats, calibration of injector, refitting cylinder head and tappet cover, changing of oil and replacement of defective parts including replacing all type filters and testing the DG sets on load. Note: (a) Only Original Spare parts shall be measured and paid separately under respective items as supply only. (b) Labour is included in this job for replacing following parts.
Supply only in replacement FUEL FILTER PAPER ELEMENT
Supply only in replacement OIL FILTER S/F GESNSET
Supply only in replacement SAFETY FILTER-SERVICE
Supply only in replacement PRIMARY FILTER-SERVICE
Supply only in replacement POWEROL SUPER PRIMIUM COOLANT 5LTR
Supply only in replacement FUEL SPILL PIPE
Supply only in replacement FILTER CARTRIDGE & WATER SEPERATOR BOWL
Supply only in replacement POWEROL VALVOLINE SUPER PRIMIUM OIL 20LT
Supply only in replacement POWEROL SUPER PRIMIUM ENGINE OIL 6.75LTR
Supply only in replacement V-BELT DRIVE 1420
Supply only in replacement DOOR LOCK-BP IND.
Supply only in replacement FUEL RETURN TUBE S/F GENSET
Supply only in replacement ALTERNATOR TYPE SMR 100_1250KVA MOSFET
Supply only in replacement ASSY, WATER PUMP S/F 6 CYL
Supply only in replacement HOSE, RADIATOR - WATER INLET/OUTLET CONN
Supply only in replacement CLAMP SAE J1 508 TYPE SLTB - SAE NO.-40
Supply only in replacement VENT HOSE ( EPDM) FOR GENSET.
Supply only in replacement GASKET,INTAKE MANIFOLD ASSLY
Supply only in replacement TURBOCHARGER / RADIATOR ELBOW
Supply only in replacement INTAKE VALVE
Supply only in replacement INLET VALVE SEAT
Supply only in replacement GUIDE VALVE-INTAKE & EXHAUST
Supply only in replacement SEAL VALVE STEM - NEF
Supply only in replacement LINER -6 CYLINDER GENSET
Supply only in replacement PISTON- 6 Cylinder genset
Supply only in replacement PISTON RING SET
Supply only in replacement LOWER BEARING SHELL
Supply only in replacement UPPER BEARING SHELL
Supply only in replacement CYLINDER HEAD GASKETS 1.4(DEF.EPMB)
Supply only in replacement TURBOCHARGER FOR MECH. GENSET as per cat part No of Mahindra 0305GAV00280N Note for Ser item No 1.01 to 1.30. Spare parts shall be used for 160/125 KVA DG Sets as required.
Servicing/ repair of DG set capacity 82.5/62.5 KVA from authorised Service Centre of existing make dg set. Removing tappet cover and cylinder heads from DG set, grinding and polishing of cylinder heads, grinding of valve sets, grinding of inlet and exhaust valve after fixing new seats, calibration of injector, refitting cylinder head and tappet cover, changing of oil and replacement of defective parts including replacing all type filters and testing the DG sets on load. Note: (a) Original Spare parts of existng make dg set shall be measured and paid separately under respective items as supply only. (b) Labour is included in this job for replacing following parts.
Supply only in replacement Service Kit For Elements Of Fuel Filter
Supply only in replacement Filter (Engine Oil)
Supply only in replacement 4Di Engine Solenoid Electral
Supply only in replacement Powerol Super Primium Coolant 5Ltr
Supply only in replacement Fan Belt
Supply only in replacement Primary Air Element - 75 Hp
Supply only in replacement Safety Air Element - 4575Gm
Supply only in replacement Emergency Push Button With 1No+1Nc Conta
Supply only in replacement Hinge With Temper Proof Hardwar Mak B.P.
Supply only in replacement Fuel Spill Pipe
Supply only in replacement Fuel Return -Pipe
Supply only in replacement Powerol Super Primium Engine Oil 6.75Ltr
Supply only in replacement Powerol Super Primium Engine Oil 1 Ltr
Supply only in replacement Pipe 4 Cyl. Nef Filter To Fip
Supply only in replacement Hose By Pass
Supply only in replacement Clip For Radiator(Green Passiv )
Supply only in replacement Hose Radiator Outlet
Supply only in replacement Hose Radiator Inlet
Supply only in replacement Hose Clip Worn Drive
Supply only in replacement Hose Oil Cooler
Supply only in replacement Hose Waterpump
Supply only in replacement Battery Cable +Ve
Supply only in replacement Battery Cable -Ve
Supply only in replacement Door Lock-Bp Ind.
Supply only in replacement Fuel Pump Repair And Calibration Charges
Supply only in replacement Injector Reparing & Caliberation
Supply only in replacement Canopy Repaire Charges
Supply only in replacement Avm Pad Mount (Ph-3E)
Supply only in replacement 62.5-75Kva_Ewh_Cpcbii
Supply only in replacement Gcu1211 Controller For Retail Dg
Supply only in replacement Liner For 88.9 Bore 110 Stroke
Supply only in replacement Piston For 88.9 Bore Long Stroke
Supply only in replacement Valve- -Exhaust
Supply only in replacement Valve Intake-Chrom.Flash-Multi
Supply only in replacement Piston Ring Set
Supply only in replacement Oil Seal
Supply only in replacement Bearing Conrod Cyl Upper & Lower
Supply only in replacement Socket Hexagonal Pipe Plug
Supply only in replacement Fuel Filter - 6 Cyl - (Sc - Fine)
Supply only in replacement Oil Filter 6 Cylinder
Supply only in replacement Water Pump 6 Cylinder Note for Ser item No 2.01 to 2.41. Spare parts shall be used for 82.5/62.5 KVA DG Sets as required.
Servicing/ repair of DG set capacity 50/40 KVA from authorised Service Centre of existing make dg set Removing tappet cover and cylinder heads from DG set, grinding and polishing of cylinder heads, grinding of valve sets, grinding of inlet and exhaust valve after fixing new seats, calibration of injector, refitting cylinder head and tappet cover, changing of oil and replacement of defective parts including replacing all type filters and testing the DG sets on load. Note: (a) Original Spare parts of existing make dg set shall be measured and paid separately under respective items as supply only. (b) Labour is included in this job for replacing following parts.
Supply only in replacement Service Kit For Elements Of Fuel Filter
Supply only in replacement Filter (Engine Oil)
Supply only in replacement Nef Engine Solenoid Electral
Supply only in replacement Powerol Super Primium Coolant 5Ltr
Supply only in replacement Fan Belt
Supply only in replacement Primary Air Element - 75 Hp
Supply only in replacement Safety Air Element - 4575Gm
Supply only in replacement Emergency Push Button With 1No+1Nc Conta
Supply only in replacement Hinge With Temper Proof Hardwar Mak B.P.
Supply only in replacement Fuel Spill Pipe
Supply only in replacement Fuel Return -Pipe
Supply only in replacement Powerol Super Primium Engine Oil 6.75Ltr
Supply only in replacement Powerol Super Primium Engine Oil 1 Ltr
Supply only in replacement Pipe 4 Cyl. Nef Filter To Fip
Supply only in replacement Pulley Drive Main
Supply only in replacement Hose By Pass
Supply only in replacement Clip For Radiator(Green Passiv
Supply only in replacement Hose Radiator Outlet
Supply only in replacement Hose Radiator Inlet
Supply only in replacement Hose Clip Worn Drive
Supply only in replacement Hose Oil Cooler
Supply only in replacement Hose Waterpump
Supply only in replacement Bearing Ball (35X72X17)
Supply only in replacement Bearing Ball (35X62X14)
Supply only in replacement Oil Seal 1L 41.10X72X8.00
Supply only in replacement Gear Hydraulic Pump - Din 9
Supply only in replacement Door Lock-Bp Ind.
Supply only in replacement Fuel Pump Repair And Calibration Charges
Supply only in replacement Injector Reparing & Caliberation
Supply only in replacement Battery Cable +Ve
Supply only in replacement Battery Cable -Ve
Supply only in replacement Controller Dse -4520-R1
Supply only in replacement Avr Model No. Mp -05
Supply only in replacement Avm Pad Mount (Ph-3E)
Supply only in replacement Valve Hsg Cover 4Di
Supply only in replacement Valve- -Exhaust
Supply only in replacement Valve Intake-Chrom.Flash-Multi
Supply only in replacement Turbocharger_3385Tcigm
Supply only in replacement Pump Water Assembly (Mdi)
Supply only in replacement Hose Pipe To Int.Manifold-P858 H1
Supply only in replacement Hose Intercooler Inlet
Supply only in replacement Sleeve Cylinder - 432 Cyl Di
Supply only in replacement Piston For 88.9 Bore Long Stroke
Supply only in replacement Piston Ring Set Nef Indigenize
Supply only in replacement Bearing Connecting Rod
Supply only in replacement Gasket Cylinder Head- 4 Cyl . Note for Ser item No 3.01 to 3.46. Spare parts shall be used for 50/40 KVA DG Sets as required.
Servicing/ repair of DG set capacity 30/20 KVA from authorised Service Centre of existing make dg set Removing tappet cover and cylinder heads from DG set, grinding and polishing of cylinder heads, grinding of valve sets, grinding of inlet and exhaust valve after fixing new seats, calibration of injector, refitting cylinder head and tappet cover, changing of oil and replacement of defective parts including replacing all type filters and testing the DG sets on load. Note: (a) Original Spare parts of existing make dg set shall be measured and paid separately under respective items as supply only. (b) Labour is included in this job for replacing following parts.
Supply only in replacement Avm Pad Mount (Ph-3E)
Supply only in replacement Service Kit For Elements Of Fuel Filter
Supply only in replacement Filter (Engine Oil)
Supply only in replacement Powerol Super Primium Engine Oil 6.75Ltr
Supply only in replacement Outer Air Element
Supply only in replacement Powerol Super Primium Engine Oil 1 Ltr
Supply only in replacement Powerol Super Primium Coolant 1Ltr
Supply only in replacement Door Lock-Bp Ind.
Supply only in replacement Fuel Pipe
Supply only in replacement Fuel Return -Pipe
Supply only in replacement Hose Air Intake
Supply only in replacement Battery Cable +Ve
Supply only in replacement Battery Cable -Ve
Supply only in replacement Gcu1211 Controller For Retail Dg
Supply only in replacement Fuel Cap With Lock & Key
Supply only in replacement Cover Valve Housing 4Di
Supply only in replacement Pump Water Assembly (Mdi)
Supply only in replacement Gasket Cylinder Head -Imported a
Supply only in replacement Gasket Oil Pan - 3 Cyl
Supply only in replacement Valve Exhaust
Supply only in replacement Valve Intake-Chrom.Flash-Multi
Supply only in replacement Sleeve Cylinder - 432 Cyl Di
Supply only in replacement Piston For 88.9 Bore Long Stroke
Supply only in replacement Piston Ring Set Nef Indigenize
Supply only in replacement Bearing Connecting Rod
Supply only in replacement Waterpump
Supply only in replacement Gasket Cylinder Head- 4 Cyl.
Supply only in replacement Turbocharger_3385Tcigm. Note for Ser item No 4.01 to 4.28. Spare parts shall be used for 50/40 KVA DG Sets as required.
Supply only in replacement Exide Express 150Ah 12V Battery with charger maintenace free complete all as specified and directed by Engr-in-Charge
All as per srl item No 5 here in before but of capacity 130 Ah 12 V .
All as per srl item No 5 here in before but of capacity 80/90 Ah 12 V .
Disconnecting and removing the self starter from 20to 50 KVA DG set and transporting it to the workshop to carry out the repair/overhauling including replacement of the worn out parts and reassembling the same with DG set and testing complete all as specified and directed by Eng-in-Charge.
All as per srl item No 8 here in before but of capacity 62.5 to 82.5 KVA.
All as per srl item No 8 here in before but of capacity 125 to 160 KVA.
Supply and fixing the self starter upto 50 KVA DG set incuding dismantling unservicable self starter from DG set and testing complete all as specified and directed by Eng-in-Charge.
All as per srl item No 11 here in before but of capacity 62.5 to 82.5 KVA.
All as per srl item No 11 here in before but of capacity 125 to 160 KVA.
Dismantling/disconnecting the worn out winding of stator of the alternator of capacity 20 to 50 KVA DG set by moving and shifting the stator to the workshop including winding the stator with super enammeled copper conductor wire of existing gauge including insulating material and varnish etc complete all as specified and as directed by Eng-in-Charge. Note: Winding shall be carried out only in workshop approved by Accepting Officer.
All as per srl item No 14 here in before but of capacity 62.5 to 82.5 KVA.
All as per srl item No 14 here in before but of capacity 125 to 160 KVA.
Supply and fix battery pulse 24 V 32 Ah suitable for DG set omplete all as specified and directed by Eng-in-Charge.
Supply and fix battery pulse 12 V 32 Ah suitable for DG set omplete all as specified and directed by Eng-in-Charge.
Excavation in trenches n.exc 1.5mtr wide and n.exc 1.5mtr deep in soft/loose soil and getting out complete all as specified and directed by Engr-in-Charge
Retuning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engr-in-Charge
Removal of excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5mtr above from starting point complete all as specified and directed by Engr-in-Charge
Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and as directed. Note : Punned thickness of sand layer shall be paid to contractor.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 of size 250mm x 150 mm x 40 mm laid flat complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement GI tubing 50mm dia light grade on poles under road crossing/cable protection complete all as specified.
Boring of holes under road, pavement, hard standing by trench less technology suitable to insert 100 mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement 3 pole AC power contactor of cap 95 Amp , 415 volt three phase complete all as specified.
All as per item No 26 here-in-before but of cap 80 Amp, 415 Volt, Three Phase.
All as per item No 26 here-in-before but of cap 65 Amp, 415 Volt, Three Phase.
All as per item No 26 here-in-before but of cap 50 Amp, 415 Volt, Three Phase.
All as per item No 26 here-in-before but of cap 32 Amp, 415 Volt, Three Phase.
All as per item No 26 here-in-before but of cap 25 Amp, 415 Volt, Three Phase.
All as per item No 26 here-in-before but of cap 16 Amp, 415 Volt, Three Phase.
S&F in replacement contactor coil upto 95 Amp contactor , 415 Volt, Three Phase.
S&F in replecemnt Strip for LT panel /Starter upto 100 Amp , 415 Volt, Three Phase.
S&F in replacement digital volt metrer 96x96mm 0 to 100 Amps complete all as specified.
S&F in replacement Digital volt meter Smi 96 0 to 400 Volt complete all as specified.
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 60 HP , 415 V , 50 Hz ,3 Phase,with suitable rating of contactor ,overload relay range ,with single phase protection with Ammeter Voltmeter complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 40 HP , 415 V , 50 Hz ,3 Phase,with suitable rating of contactor ,overload relay range ,with single phase protection with Ammeter Voltmeter complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 30 HP , 415 V , 50 Hz ,3 Phase,with suitable rating of contactor ,overload relay range ,with single phase protection with Ammeter Voltmeter complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 20 HP , 415 V , 50 Hz ,3 Phase,with suitable rating of contactor ,overload relay range ,with single phase protection with Ammeter Voltmeter complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 10 HP , 415 V , 50 Hz ,3 Phase,with suitable rating of contactor ,overload relay range ,with single phase protection with Ammeter Voltmeter complete all as specified and directed by Engr-in-Charge.
S&F in replacement Single phase preventor suitable for low/high voltage cut, over current, phase failure complete all as specified.
S&F in replacement of MCCB of capacity 630 Amps , 4 pole, 50 KA complete all as specified and directed by Engr-in-charge.
All as per item No 43 here-in-before but of capacity 250 Amps , 4 pole, 36 KA
All as per item No 43 here-in-before but of capacity 200 Amps , 4 pole, 36 KA
All as per item No 43 here-in-before but of capacity 160 Amps , 4 pole, 36 KA
All as per item No 43 here-in-before but of capacity 125 Amps , 4 pole, 36 KA
All as per item No 43 here-in-before but of capacity 100 Amps , 4 pole, 16 KA
All as per item No 43 here-in-before but of capacity 63 Amps , 4 pole, 16 KA
S&F in replacement of changeover of capacity 200 Amps , 4 pole complete all as specified and directed by Engr-in-charge.
S&F in replacement BOCR 3EZ thermal over load relay 05-60 Amps,415 volts , 50 Hz complete all as specified and directed by Engr-in-charge. Note:- Contractor have to install BOCR Relay in starter with in 45 days after accepting of tender otherwise Rs 20000 /- per item will be recovered from contractor for non execution.
S&F in replacement Electronic overload relay 0.5-60 Amp complete all as specified.
S&F in replacement Electronic Timers Type ST 100, 3 - 30 secs complete all as specified.
Supply and fix in replacement PVC insulated 1100 volt grade (H/D) copper conductor cable 25 Sqmm, 3 core flat submersible cable ISI marked including copper thimbles as required including taking out U/S Cable complete all as specified and directed by Engr-in-Charge.
All as per item No 54 here-in-before but of copper submersible cable of size 16 sqmm 3 core.
All as per item No 54 here-in-before but of copper submersible cable of size 10 sqmm 3 core.
All as per item No 54 here-in-before but of copper submersible cable of size 6 sqmm 3 core.
Supply, laying, jointing and testing in replacement Xlpe PVC insulated armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 sqmm, 3.5 core complete including taking out U/S Cable all as specified by Engr-in -charge.
All as per Item Ser No 58 here in before but cross sectional area 95 Sqmm, 3.5 Core.
All as per Item Ser No 58 here in before but cross sectional area 70 Sqmm, 3.5 Core.
All as per Item Ser No 58 here in before but cross sectional area 35 Sqmm, 3.5 Core.
Supply and fix in replacement Non Return Valve with flanged ends of size 250mm dia complete including rubber/fiber board gasket, uts washer etc complete all as specified and directed by Engr-in-Charge
Description all as per items Ser No 68 here but 200mm dia.
Description all as per items Ser No 68 here but 150 mm dia.
Description all as per items Ser No 68 here but 100 mm dia.
Supply and fix in replacement CI Sluice valve with flanged ends of size 250mm dia complete with gun metal or stainless steen spindle and cast iron hand wheel including rubber/fiber board gasket, nuts, waher etc complete all as specified and directed by Engr-in-Charge
All as per item Ser No. 72 here in before but 200 mm dia.
All as per item Ser No. 72 here in before but 150 mm dia.
All as per item Ser No. 72 here in before but 100 mm dia.
Material and labour run lead joints suitable for 200/300mm bore CI pipe and fittings including jointing material such as lead, spun yarm etc including taking out old run lead joints complete all as specified and directed by Engr-in-Charge
Material and labour run lead joints suitable for 100/150mm bore CI pipe and fitting including jointing material such as lead, spun yarn etc including taking out old urn lead joints complete all as specified and directed by Engr-in-Charge
Dismantling wrought iron or mild steel work of any description ,rusted ,worn out, complete all as specified.
Material and labour for Mild steel framed work for such as angle/ grills Chanel/stand , granting’s/Mild Steel plates etc with ends of bars shouldered and riveted or forged into spikes, frame guard bars barred iron doors, ladders, framed balusters walk ways, railings frame work as per direction and similar work conforming to Fe-290 Gde-E-165 at any installation as per requirement complete all as specified and directed by Engr-in-Charge.
Material and labour for rubber moulded machine pressed precast concrete interlocking paver with grey cement confirming to IS -15658-2000 of 60 mm thickness , M-35 grade as in path , hard standing etc laid over and including 25 mm compacted sand cushioning , including 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and remving excavated soil exc 50 mtr but n . exc 250 mtr , at any installation as per requirement complete all as specified and directed by Engr-in-charge. Note:- Rate of PCC are included in this item . There will be no extra payment for PCC.
Complete removal of the wild grass/ vegetation from surrounding area of SEWAGE Well installations area for each sewage well and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified. Note:- T&P machinary will be provided by the contractor.Cleaning should be done regular per month otherwise penalty of Rs. 1000/ per day per well for non cleaned surrounding area.
S&F Electric Resistance Insulated Rubber Floor mat sheet of size 1mx2mx25mm thick ISI marked and equivalent colour as per direction with fixing mtrls complete all as specified and as directed.
M&L for removing old paint from surface of LT panel by scraping,rubbing and making good surface for painting and applying powder coated spary painting with existing colour complete as specified and directed.
M&L for atending any type pump/motor/LT panels/DGs/Starters complaint at Sewage well and rectify the same, rates are also included for replcement of thimbles any type and any size with nut-bolts and cable jointing with tap, gland packing, greasing in pumps/valves with all connected items all as specified by the Engr-in-Charge. Note: Complaint should be rectify within 06 Hrs otherwise a penalty of 250 Rs per day will be imposed.
Maintenance and repair to leakage/blockage of water supply MS/CI/DI pipe line of 80 mm to 300 dia size including necessary excavation required for taking out burning out lead joint or damaged rubber ring/hole from position and making the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or Tyton joint or necessary fitting required as per site properly including welding work and making the pipe line leak proof completly to the entire satisfaction of Engineer-in-Charge .
M& L for earthing in replacement complete with galvanized steel earth plate electrode 60 x60x6 mm thick , buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with using galvanised iron strip 32x6 mm thick as earth lead by means of bolts , nuts , check nuts and washers of galvanised iron or steel all as shown in electrical plate no 5 , with top edge of plate not less than 1.5 m below normal ground level , surrounded from all sides by charcoal dust and common salt in alternative layers of 15 cm depth and earth connected with equipment by means of bolts , nuts, check nuts and washers of galvanised iron and connection to earth mesh including welding and complete with charcoal after installing earth strip , earth work and filling pit with PCC 12:4 type B-1 and pre cast RCC cover mix (1:1:5:3) complete all as specified and directed by Engr-in-Charge.
Dismantling and taking down rusted old UNSV LT Panel outdoor covers and M&L for Outdoor covers of LT panel board of existing size , outer shell made out of 3.1 mm thick MS sheet with front openable and back bolt openable lockable, followed by powder coated painting having thickness not less than 100 microns complete all as specified and directed by Engr-in-charge
Note:- Amount of credit of Rs 174370.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
Raman Electric Trading Co
Saurav Enterprises
Mohinder Pal and Sons
Esha Engineers
Bidder Name
Mohinder Pal and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .