| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹29.9 L+₹9.9 L (49.5%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹31.4 L+₹11.4 L (56.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹33.2 L+₹13.2 L (66.1%)Rejected-Finance SHREE NIVAS LIMDA LANE JAMNAGAR GUJARAT PIN 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance Not L1. | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected for F bid opening. |
| Sl No | Description | Qty | Unit | SURESH ELECTRICALS L2 | DWARKADHISH ENTERPRISE L3 | M/s super construction L4 | MADHAV ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in hard/dense/soft/loose soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth for laying cables in trenches/pole foundation and getting out complete all as specified and directed. | 324 | Cum | 621 ₹2,01,204 | 350 ₹1,13,400 | 250 ₹81,000 | 180 ₹58,320 Lowest |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each in soil complete all as specified and directed. | 217.4 | Cum | 135 ₹29,349 | 100 ₹21,740 | 70 ₹15,218 Lowest | 90 ₹19,566 |
| 3.00 | Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above starting point where directed. | 106.6 | Cum | 270 ₹28,782 | 110 ₹11,726 | 80 ₹8,528 Lowest | 90 ₹9,594 |
| 4.00 | Material & Labour for Sand Cushioning to UG cable 40mm wide 15cm and 8cm thick above and below the cable respectively excluding laying of PCC cable cover for protection on the top of the sand cushioning complete all as specified and directed.
Note : Punned thickness of sand will be measured & paid. | 92.34 | Cum | 1,650 ₹1,52,361 | 1,200 ₹1,10,808 | 800 ₹73,872 | 450 ₹41,553 Lowest |
| 5.00 | Supply & Fixing in repair GI tubing light grade 40 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed. | 24 | RM | 392 ₹9,408 Lowest | 500 ₹12,000 | 500 ₹12,000 | 650 ₹15,600 |
| 6.00 | Supply & Fixing in repair GI tubing light grade 50 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed. | 24 | RM | 425 ₹10,200 Lowest | 600 ₹14,400 | 600 ₹14,400 | 750 ₹18,000 |
| 7.00 | Taking down old unsv reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed. | 6,600 | Each | 1.2 ₹7,920 | 5 ₹33,000 | 10 ₹66,000 | 0.5 ₹3,300 Lowest |
| 8.00 | Laying only PCC cable cover for LT / HT UG cable, of any description retrieved complete all as specified and directed. | 3,607 | Each | 1.2 ₹4,328.4 | 5 ₹18,035 | 10 ₹36,070 | 0.5 ₹1,803.5 Lowest |
| 9.00 | Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm thick complete all as specified and directed. | 2,993 | Each | 30 ₹89,790 | 40 ₹1,19,720 | 24 ₹71,832 | 17 ₹50,881 Lowest |
| 10.00 | Supply & Fixing GI pipe 15 mm dia light grade along the pole for covering cable including clamp, nuts, bolts & washers etc. complete all as specified and directed. | 40 | RM | 130 ₹5,200 Lowest | 150 ₹6,000 | 300 ₹12,000 | 210 ₹8,400 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF HIGH MAST LIGHTS, SOLAR OPERATED LIGHTS, PERIMETER LIGHTS, AND INTERNAL STREET LIGHTS ALONG WITH CERTAIN OTHER CONNECTED WORKS AT AF-II UNDER GE (AF) JAMNAGAR NO.2
2025_MES_716684_1
8567/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹60,000
Yes
19 Sept 2025
25 Jun 2025
24 Jul 2025
25 Jun 2025
23 Jul 2025
9 Jul 2025
Amount
Excavation in trenches in hard/dense/soft/loose soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth for laying cables in trenches/pole foundation and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each in soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above starting point where directed.
Material & Labour for Sand Cushioning to UG cable 40mm wide 15cm and 8cm thick above and below the cable respectively excluding laying of PCC cable cover for protection on the top of the sand cushioning complete all as specified and directed. Note : Punned thickness of sand will be measured & paid.
Supply & Fixing in repair GI tubing light grade 40 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed.
Supply & Fixing in repair GI tubing light grade 50 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed.
Taking down old unsv reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.
Laying only PCC cable cover for LT / HT UG cable, of any description retrieved complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm thick complete all as specified and directed.
Supply & Fixing GI pipe 15 mm dia light grade along the pole for covering cable including clamp, nuts, bolts & washers etc. complete all as specified and directed.
Taking out old/unsv LT cable any size from trenches/duct, stacking at site, checking by megger and carry out repair/replacement of defective cable complete all as specified and directed.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area 2.0 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area 4.0 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 25 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 35 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 50 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 70 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 120 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and fixing / passing through pipe from junction box to street light, 2.5sqmm 1100 volts grade heavy duty cable with PVC insulated multistranded copper conductor cable flame retardant low smoke & halogen 1100volt confirming to IS complete all as specified and directed.
M & L for shifting of solar light street pole to a distance not exceeding 50 mtr and erect in true vertical position steel tabular pole, around 15.0 metres long complete all as specified and directed. Work consisting following items under Note: (i) PCC foundation & coping, Excavation earth work . (ii)nut bolt like as existing as required. (iii) hydro crane for shifting the pole (iv) material and labour regarding that work etc.
Material & labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation of electric poles, struts, blocks with and including necessary form work, and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Material & labour for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in foundaiton of stays, bed concrete and coping of poles with and including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Supply & fixing bracket made out of GI light grade pipe of 40/35 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50x6mm and 04 sets of nuts, bolts and washers including painting with two coats of synthetic enamel paint over a red oxide primer including dismanting existing old and unservicable security light complete all as specified and directed.
M&L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
M&L for earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to required items at another end e and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I (1991) complete all as specified and directed.
S&F LED Street Light fitting 35 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT (K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Street Light fitting 45 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED street light fitting 90 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED street light fitting 120 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
Periodical Maintenance / servicing of 29 Watt Solar street light by carrying out following maintenance / servicing activity for minimum two times (at interval not less than 5 months) complete all as specified and directed. (a) M&L for top up of battery distilled water and checking of specific gravity.If specific gravity beyond normal value entire qty of distilled water shall be replaced. (b ) Making proper alignment of solar panels facing towards south direction. (c) Cleaning the upper surface of solar panel with glass cleaning solution. (d) Clean the battery terminals and nut/bolts with the help of filling tool, make sure the threads are not affected and nut -bolts are properly tightened and application of petroleum jelly at the terminals of the battery.
S&F in repairs pole mounted junction box (Street light boxes) weatherproof cabinets IP -65-IK-09 class II with removable chasis and faceplates, lockable door handle, sealable cover, self extinguishing conforms to EN 60439-3, for single phase lighting system, suitable for 6 module with 1 row complete all as specified and directed. Make:Hensel /L&T or equivalent as mentioned in Appx 'B' to PS.
S & F in repairs 4 pole contactor 25A 4NO , suitable for 415V AC complete all as specified and as directed. Make: ABB cat part no.1SBL41120R or equivalent make as mentioned in Appx 'B' to PS.
S & F in repair OT manual changeover switches 250 AMP, 4 pole, suitable for 415 V AC complete all as specified and directed. Make: ABB cat part OTE04CP or equivalent makes as mentioned in Appx 'B' to PS.
S & F in repairs MCB DP 32A DX3 DP, suitable for 230V AC complete all as specified and directed. Make: Legrand Cat part No.408636 or equivalent as mentioned in Appx 'B' to PS.
Supply, fix in repair analog weekly timer Switch of supply voltage 240V AC, 50/60 Hz complete all as specified and directed. Make :- Legrand cat part no.412654 or equivalent as mentioned in Appx 'B' to PS.
Supply and fix in repair LED decorative post of lantern 45 Watt fittings including all accessories complete fixing accessories and clamp including 4 metre height painting of pole with block paint, fixed in position complete all as specified and directed. Make:- CG Cat part No:- LPTOI-45- CDL/T or equivalent as mentioned in Appx 'B' to PS.
Supply and Fix LED Bollard light fitting 9 watt, inbuilt driver mechanism, robustly designed, IP 65/IK10 protection complete with base plate and provision of wire 2.0m copper conductor from fitting to connection point incl taking down old unsv light fitting complete all as specified and directed. Make: Philips City Cube Bollard D Cat part No: BCP400LED09 D CW PSU GR S1 or equivalent as mentioned in Appx 'B' to PS.
S&F LED Flood Light fitting 210 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S & F in repair 12V, 120Ah capacity Lithium Ferro Phosphate battery (at C/10 discharge rate) confirming to IS 16270 and IS 16046 complete with initial charging suitable for LED street light fitting complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary: 220-240V AC, 50/60Hz suitable for 9/10watt LED bollard fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary:220-240V AC, 50/60Hz suiatble for 40/45 watt street light fitting/post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and erect in true vertical position prestressed concrete pole, 9.0 metres long. 102mm x 152mm at top and 102 mm x 289mm at bottom class 10 including taking out old/unsv complete all as specified and directed. Note: (i) PCC foundation & coping, Excavation earth work will be measured and paid for seperately under respective item of schedule "A".
SURESH ELECTRICALS (BID ID -3360092)
DWARKADHISH ENTERPRISE (BID ID -3360410)
M/s super construction (BID ID -3360930)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .