| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ok | |
| 2 | L2₹34.5 L+₹8.7 L (33.6%)Rejected-AOC | L2 | Rejected-AOC ok |
Tender Value
₹39.3 L
EMD Value
₹78,600
Closing Date
6 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
COMPREHENSIVE MAINTENANCE OF COOLING, HEATING APPLIANCE AND ALLIED WORKS UNDER AGE E/M-II OF GE DEHRADUN
2021_MES_480411_1
9632/DDN/E8
Open Tender
Civil Works
Item Rate
334 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹78,600
Yes
10 Dec 2021
7 Oct 2021
10 Nov 2021
7 Oct 2021
6 Nov 2021
22 Oct 2021
60 days
Amount
Comprehensive/preventive maintenance of the undermentioned Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/desert cooler and kitchen equipment of different capacities by carrying out periodically maintenance of plants including cleaning of filters, condenser externally with vacuum cleaner, tightening electrical connection, lubrication, filling refrigerant gas etc ensure serviceability throughout maintenance period complete and attending complaints all as specified and as directed
Note: (i) Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler/ kitchen equipment and Central AC plants shall be taken from department on "as and where installed" basis.
(ii) Window/ Split /Central ACs are to be maintained for heating as well as cooling mode all as specified and directed.
(iii) The contractor shall ensured and assessed at the site any initial maintenance required, to make the all window/Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler/Kitchen Equipment and Central AC plants in fully proper working condition, at the time of taking over and he shall be liable to make all listed handed over units functional within 15 days after commencement of work.
(iv) The date of periodical check will start from the date of commencement of work.
(v) After completion of contract, contractor shall hand over the all " handed over Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler/ kitchen equipment and Central AC plants" in perfect running/functioning condition to the department.
(vi) Contractor shall provide his authorized Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type belonging to the said plants and equipments.
(vii) Penalty for non rectifying the defect in time (within 24 hrs) will be charged to contractor and the amount of penalty @ Rs 500/- per day will deducted from the due payment of contract.
(viii) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M.
(ix) Cost of attending day to day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made.
(x) Old material obtained from spares replaced under this item shall be contractor's property, no payment will be deducted from due payment for this.
(xi) Cost of all spares including refrigerant for charging the gas of any type/Nitrogen pressure test to find out leakage or topping up the gas in system are deemed to be included in the item rate, except Compressor, condenser Motor, cooling coil motor and blower motor. however Labour required to carryout the maintenance / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor.
(xiii) Compressor, condenser Motor, cooling coil motor and blower motor, rewinding / replacement of condenser fan motors etc if required shall be measured and paid separately.(xiv) All plants and equipment shall be kept functional at all the time and employed well competent/qualified engineer/mechanic.
1.5/2.0 Ton capacity window type AC. (53 Nos for 11 month)
1.5/2.0 tons capacity split type AC. (145 Nos for 11 months)
Water cooler of any capacity. (294 Nos for 11 months)
Refrigerator capacity 165 to 310 Ltr. (231 Nos for 11 months)
Deep Freezer up 310 Ltr (40 Nos for 11 months)
Desert Coolers (257 Nos for 11 months)
RO water purifier system (20 Nos for 11 months)
Walk in cooler cold storage room (4 Nos for 11 months)
Deep freezer vertical type 4 door (10 Nos for 11 months)
Central AC plant 80 TR with Condenser pump 20 HP 4 Nos, FRP cooling tower by electrically operated and pump side by filling glands, AHU 2 Nos complete (02 Nos for 11 months)
Central AC plant 7.5 TR complete. (03 Nos for 11 months)
Electric operated veg processing machine 80-100 Kg/Hr (1 Nos for 11 Months)
Electrically operated Dough kneading machine (01 for 11 Months)
Package type AC plant 5 TR complete. (02 Nos for 11 months)
LPG static pot burner (1 Nos for 11 Months)
Diesel operated water heaters.
Disconnecting the electrical and refrigerant connection of defective sealed unit of 1.5 Ton window type/ split type AC and replacing the compressor connecting the sealed unit both electrical and refrigerant connections including charging refrigerant gas/nitrogen pressure test to find out leakage as required complete all as specified & directed. Notes :- (a) Old compressor taken down/ removed shall be replaced with the same existing make. (b) Compressor shall be purchased from OEM manufacturer/authorised dealer of the manufacturer as one to one replacement. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of installed. Supporting documents for replacement from manufacturer/ dealer alongwith warranty certificate and paid vouchers shall be furnished by the Contractor before claiming payment. Note: Gas charging will be measured and paid only once in throughout contract period after repetitive leakage/topping.
All as per ser item No 2 here in before but for 2/2.5 TR AC complete all as specified & directed.
All as per ser item No. 2 here in before but for walk in cooler cold room complete all as specified & directed.
S & F in replacement starting relay box type suitable for 1.5/2TR capacity for window type/split type AC.
S & F in replacement starting capacitor of capacity 80-120 MFD, suitable for 1.5 /2 TR capacity window type/split type AC.
S & F in replacement of running capacitor of capacity 36 MFD suitable for 1.5/2 TR capacity window type AC, complete all as specified and directed.
All as per ser item No. 7 but for 50 MFD.
All as per item No 7 above but of capacity 40 to 60 MFD.
All as per item No 7 above but of capacity 2.5 to 4 MFD.
All as per item No 7 above but of capacity 5 to 6 MFD.
S & F in replacement of 220 V SP contactor for Split type AC 1.5 Ton/2 Ton of existing make & capacity, complete all as specified and directed.
S & F in replacement of blower/condenser AC electric fan motor 1/10 or 1/8 HP SP 230 volts 1400 RPM suitable for 1.5/2TR window type/split type AC and testing at full load, complete all as specified and directed.
S & F in replacement of condenser fan blade for AC window type/Split type 1.5/2 Ton of any make & capacity, complete all as specified and directed.
S & F in replacement of blower fan motor for AC Window type /Split type outdoor unit 1.5/2 Ton of capacity/size, complete all as specified and directed.
S & F in replacement of blower fan motor for AC Split type indoor unit 1.5/2 Ton capacity/size, complete all as specified and directed.
S & F in replacement of PVC front grill for window type AC's as per AC make upto 1.5/2 TR capacity complete all as specified and directed by Engineer-in-charge.
Shifting of Air Conditioner of any type and make, up to 2 TR from existing location to other location and, Installing indoor and outdoor units of split type AC & window type AC at the locations as directed including provision of necessary brackets (L type) clamps, GI nuts, bolts and washers etc for fixing of indoor/ outdoor units/ window type AC including testing and commissioning and making good disturbed surface complete all as specified & directed. Note : PVC pipe protection/ drain pipe/ control cable, extra copper tubing of any size for suction/discharge will be measured and paid separately. Connecting up, topping up of refrigerant gas. Nitrogen pressure test to find out leakage, commissioning and testing complete all as specified & directed. Note : Gas charging will be measured and paid only once in throughout contract period after repetitive leakage/topping.
Supply & fixing reverse cycle valve for heating system in window type AC 1.5/2 Ton capacity including charging of refrigerant gas R-22 and arresting all leakage and testing on full load, complete all as specified and directed. (Note: Charging of R-22 shall be paid under relevant item)
S & F in repair/replacement of remote sensing unit suitable for 1.5 Ton split type AC fixed in PCB board complete all as specified & directed.
All as per item No 20 above but for 2 Ton Split AC Complete all as specified & directed.
S & F in repair/replacement remote assembly corded/cordless as per existing make and size complete as specified.
S & F in repair/replacement thermostat switch suitable for 1.5/2 TR capacity window type/split type AC, complete all as specified and directed.
S & F in repair/replacement cable of PVC insulated copper flexible cable of size (70/.0076),Three core multi stranded suitable for window/Split AC 1.5/2 Ton capacity, complete all as specified & directed.
S & F in repair/replacement of copper pipe with nitrite insulation of sizes 1/4” (6.35mm) for split/window AC, water cooler, complete all as specified & directed.
All as per item No 26 above but of sizes 3/8” (9.52mm).
All as per item No 26 above but of sizes 5/8” (15.88mm).
All as per item No 26 above but of sizes 1/2” (12.7mm) .
Disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 Ltrs and replacing the compressor and connecting the sealed unit both electrical and refrigerant connections including Nitrogen pressure test to find out leakage charging of refrigerant gas as required complete all as specified & directed. Notes: - (a) Old compressor taken down/ removed shall be replaced with the same make. (b) Compressor shall be purchased from manufacturer/ authorized dealer of the manufacturer as one to one replacement. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of installation. Supporting documents for replacement from manufacturer/ dealer along with warranty certificate and paid vouchers shall be furnished by the Contractor before claiming payment. Charging of refrigerant gas will be measured and paid only once in throughout contract period after repetitive leakage/topping.
All per Item No 30 above but water cooler of capacity up to 150 ltrs.
S & F in replacement starting capacitor 60 to 100 MFD for water cooler of any capacity, complete all as specified and directed.
S & F in repair/replacement of running capacitor 10 to 30 MFD suitable for water cooler compressor sealed unit of any capacity, complete all as specified and directed.
S&F junction box made of glass fiber reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in PCC foundation etc, including taking down the old one complete all as specified & directed.
S & F in repair/replacement of thermostat switch of water cooler of any size & make for Compressor unit, complete all as specified and directed..
S & F in repair/replacement over load relay protector suitable for water cooler compressor unit of any capacity complete all as specified and directed.
S & F in repair/replacement starting relay complete for water cooler compressor unit of any capacity, complete all as specified and directed.
S & F in repair/replacement starting relay kit with overload protection for water cooler compressor unit any capacity, complete all as specified and directed.
Taking down u/s condensing fan motor and S&F and testing of condenser fan Motor of Water cooler for 1/2 HP for 1.0 TR or higher capacity duly connected and testing fixed in original position, complete all as specified and directed.
All as per above item No 39 but 0.5 TR to 1.0 TR capacity, complete all as specified and directed.
All as per above item No 39 but 0.33 TR capacity, complete all as specified and directed.
Supply, fixing and testing in replacement of condensing fan motor blade for water cooler of any make & capacity, complete all as specified and directed.
S&F in replacement of brass float valve assembly 15mm dia with Nipple & Long screw with washers complete in water cooler, complete all as specified and directed.
Repairing the leakage in the steel water tank of any make & capacity water cooler by welding brazing/soldering/testing & commissioning complete all as specified & directed.
S&F in replacement push cock, brass chromium plated, self closing push button type, screwed for iron pipes ferrules of size 15 mm bore complete make as approved by GE and all as specified & directed.
S&F in replacement of stainless steel tray suitable for water cooler of 40/80 Ltrs as per existing make & capacity complete all as specified & directed.
All as per item no 46 above but for water cooler of 150 Ltrs capacity.
S&F in replacement of PVC drain pipe up to 2m long of size 40mm dia complete along with Hose clip of suitable sizes complete all as specified and directed.
M&L for charging of refrigerant gas R-134a with required pressure including arresting of all leakage and testing on full load, gas charging, Nitrogen pressure test to find out leakage pressure testing & arresting of all leakage throughout the maintenance contract period will be measured and paid only once throughout contract period complete after repetitive leakage/topping all as specified and directed.
All as per item No 49 above but Refrigerant gas R-22 or equivalent
S & F in repair/replacement thermostat switch suitable for refrigerator upto 320 Ltrs any make and capacity for refrigerator, complete all as specified and directed.
S & F in repair/replacement starting relay box type suitable for refrigerator up to 320 ltrs of capacity complete all as specified and directed.
S&F in replacement of compressor, company repaired in exchange of old unserviceable compressor, sealed unit for deep freezer of any capacity up to 320 Ltrs, complete including testing with nitrogen gas pressure to find out leakage and charging of gas R-134a upto required pressure and proper working effect to entire satisfaction and testing on full load. Charging of gas throughout maintenance contract period will be measured and paid only once for throughout contract period after repetitive leakage/topping complete all as specified & directed. Note:- 1. Charging of gas with labour shall be measured & paid separately only once in throughout contract period. 2. Old compressor taken down shall be replaced with same make & Capacity. 3. Compressor shall be purchased from authorised dealer of manufacturer as one to one replacement compressor shall be in sealed condition & shall bear warranty for 12 months from date of purchase. Supporting documents from manufacturer dealer alongwith warranty certificate & paid vouchers shall be furnished by contractor before claiming payment.
All as per item No 53 above but for refrigerator up to 320 Ltrs capacity.
S & F in repair/replacement bulb for refrigerator pin/screw type LED 5 watt, complete all as specified and directed.
S & F in repair/replacement magnetic door gasket suitable for Refrigerator of existing make, up to 180 litres capacity complete all as specified & directed.
All as per item No 56.00 above but for refrigerator 185 to 310 litres capacity.
S & F in repair/replacement of ice tray, suitable for Refrigerator of existing make, upto 180 litres capacity, complete all as specified & directed.
Supply in replacement vegetable tray, suitable for Refrigerator of existing make, upto 180 litres capacity, complete all as specified & directed.
All as per item No 59 above but for refrigerator 190 to 310 litres capacity.
Supply in replacement of freezer chamber existing make & size for upto 180 Ltr capacity refrigerator direct cool complete all as specified & directed.
All as per item No 61 above but for refrigerator frost-free double door including heater, blower etc for 190 to 310 litres capacity.
M&L in replacement of condenser for refrigerator as per existing make & any capacity, complete all as specified and directed.
M&L for Repair/overhauling/servicing of AHU by observing abnormal sound and cause for it at Signal Centre, 501 FSEG & RIMC by dismantling and reassembling the same after cleaning of all filters by pressure air including replacing of ball bearing with 02 Nos, greasing of all movable parts, housing & alignment of blower shaft for smooth running and maintain for its smooth functional throughout contract period complete all as specified and directed.
M&L for dismantling blower shaft of AHU up to 80 TR by removing the belt and pulley, blower drum, dismantling the shaft, welding, turning, grinding to have its original dimension balancing the shaft and refitting the same in AHU including reassembling the blower, pulley etc with new bearing of existing size for smooth running and maintain for its smooth running/functional throughout contract period complete all as specified and directed.
Supply and filling screw synthetic compressor oil for Central AC plant Carrier 80 TR complete all as specified and directed.
Supply and fixing internal filter for Central AC plant Carrier 80 TR complete all as specified and directed.
Supply and fixing External filter for Central AC plant Carrier 80 TR complete all as specified and directed.
Supply & Fixing in replacement of V belt B-84 complete all as specified & directed.
Supply & Fixing in replacement of belt B-77 for blower motor complete all as specified & directed.
Supply & Fixing in replacement of belt B-102 for Washing machine complete all as specified & directed.
S & F in repair/replacement air strip heater 3 KW finned type suitable for AC Plants complete all as specified & directed.
M&L for cleaning complete FRP cooling tower with de-scaling agent removing algee deposited, applying compound for leak proof complete with greasing of cooling tower motor and mechanical components replacement of PVC cooling fills of cooling Tower, dismantling pre fills of any size, cleaning & re fixing the same including replacement of unserviceable water spray nozzles, nut bolts, washer, greasing fan motor/ toping up gear oil in gear box, arresting all leakages with M-Seal/leak proof solution, replacement of drain plug socket and end cap all as per site requirements etc complete at 80 TR RIMC. complete all as specified and directed
All as per Sl item No. 73 here-in-before but for 501 FSEG, Signal Centre, complete all as specified & directed.
M&L for preparation of old surface of any size of pipe and applying one coat of red oxide primer and insulation sheet of 25 mm thick glass wool duly wrapped with fire retardant material (make Twing or equivalent) having density 32 Kg/cum duly fixed with adhesive over outer prepared surface of pipe/make up tank. Glass wool sheet shall be wounded with hessian cloth and netting of galvanized steel wire 0.63 mm dia of 12mm mesh size over the layer of fixed glass wool and hessian cloth complete all as specified and directed
Supply & fixing in replacement of gun metal Globe valve 150mm dia with side handle operated complete with required packing/ gasket material complete all as specified and directed.
Supply fixing in replacement of power contactor with Aux contact AC 3 rating, complete all as specified and directed.
All as per item No 77 above but of size (MNX-18)..
All as per item No 77 above but of size (MNX-25).
All as per item No 77 above but of size (MNX-32).
Supply & fixing in replacement of power contactor type ML 1.5 ,AC 3 rating complete all as specified & directed.
All as per item No 81 above but of size ML- 2, AC 3 rating.
All as per item No 81 above but of size ML- 3, AC 3 rating.
S & F in repair/replacement ON/OFF push button for panel mounting type (Red/Green), complete all as specified & directed.
Supply in replacement of indicating lamp LED type RYB, complete all as specified & directed.
S & F in repair/replacement digital three phase voltmeter 0-500V, complete all as specified & directed.
S & F in repair/replacement digital three phase Amp meter. Range: 0-100A, complete with suitable CTs complete all as specified & directed.
M&L for disconnecting and taking down unserviceable electric motor and mono block pump set of capacity 2 HP from base frame and shifting to workshop for rewinding, opening complete, carefully and cutting/cleaning burnt out winding wire from starter, carefully repairs to damage slots including Rewinding of motor with super enameled copper wire, gauge same as original & varnishing the same drying tapping with cotton tapes, all electrical connections duly soldered/brazed properly, reassembling, re-shifting & reinstallation at site including testing & commissioning at full load complete all as specified & directed.
All as per item No 88 above but 3 HP 3 Phase 415 Volts complete all as specified & directed.
All as per item No 88 above but 5 HP 3 Phase 415 Volts complete all as specified & directed.
All as per item No 88 above but 7.5 HP 3 phase 415 Volts complete all as specified & directed.
All as per item No 88 above but 20 HP 3 phase complete all as specified & directed.
Supply & fixing in replacement dial type pressure gauge 0-150/0-300. Kg/Sqcm, complete all as specified & directed.
Supply in replacement pre-fine blower filter 10-20 Micron of size 540x640x50mm as per existing make & size complete all as specified and directed.
Supply in replacement of fine blower filter 5 Micron of as per existing size and make 610x610x150mm, complete all as specified & directed.
Supply in replacement solenoid valve 0.5" for dish washer complete all as specified and directed
Dismantling electric and water connection of cap 25/50 ltr's geyser, taking down from its original position on ground, dismantling geyser complete such as removing tank from its outer body, removing apparatus plate from the tank, de scaling the geyser inner tank and apparatus plate complete, testing its thermostat, heating element, and tank from leakage, reassembling the geyser, replacement of unserviceable parts such as heating element, rubber gasket & testing the geyser and installation of the geyser into its original position and connecting all electric and water supply connection complete and testing on completion complete all as specified & directed. Note:- (i) Heating element & Apparatus if require to be replaced shall be measured and paid separately as supply only under respective item. (ii) Nut, bolts and hold fasteners if require to be replaced shall be deemed to be included in the quoted rates of this item. (iii) All repair shall be carried out on complaint basis and measurement will be made only once throughout the contract period irrespective number of repair carried out in the same Geyser. (iv) All repairs shall be carried out on complaint basis contractor shall detail his rep to carry out the maintenance and collect complaint slip from concerned JE daily upto 11.00 Hrs.
Supply only heating element any type/size as per site requirement of capacity 2 KW ISI Marked.
Supply only thermostat for geyser long type 11" in length as per site requirement temp setting on 60 degree centigrade ISI Marked, long type complete all as specified and directed.
Supply only Apparatus plate for 25/50 liters capacity geyser made out of brass, chromium plated complete all as directed.
Supply only split plate for 25/50 ltrs capacity geyser as per site requirement and made out of 20 guage MS sheet duly painted complete all as specified and directed.
Supply only geyser inner tank made out of stainless steel sheet conforming to relevant IS for 50 ltrs geyser as per existing model and make, complete all as specified and directed.
All as item No 102 above but for 25 ltrs.
Supply only geyser outer cover complete with upper cover & bottom cover made out of 20 SWG MS sheet, duly painted with one coat of red oxide primer and two coat of first quality synthetic enameled white paint marking MES No complete all as directed for 25/50 ltrs capacity geyser all complete as specified and directed.
Supply only syphon assembly for geyser having hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as specified & directed.
Supply only fusible plug made out of brass and lead complete all as specified and directed.
S&F three core PVC insulated flexible and over all PVC round cable of size 40/0.0060 with multi stranded copper conductor complete all as specified and directed.
S&F in replacement of water supply PVC flexible connection Nylon braided with suitable threaded brass check nut with washer, unions on both side ends complete suitable for hot/ cold water 15mm dia, 45 cm long minimum complete all as specified and directed.
Supply only pressure release valve as per existing make and size geyser spring loaded 15 mm dia complete all as specified and directed.
Supply only rubber Gasket as per existing make/size site requirement suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
S&F in replacement of sheet metal enclosure with socket plug top SPN & earth enclosure with 2 pin earth plug with socket complete with on SP MCB 20 Amp 'B' Series complete all as specified & directed.
Dismantling and taking out the existing old unserviceable fan motor with blade including mounting brackets from Desert coolers and S&F new 3 speed fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable for D/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed.
Taking down desert coolers of capacity upto 5000 Cum/hr by dismantling the unserviceable parts of Desert coolers, checking the general servicing complete, cleaning all the components by removing the side panels and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panel and reassembling with new filter pad made out of wooden wool suitable for air grills of desert cooler as per existing size complete with electrical connections and writing the MES No complete all as specified & directed. Note: (i) Petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department complete all as specified and directed. (ii) Spare parts shall be measured and paid separately under respective item of sch ‘A’.
Supply only the following items:-
(a) Water circulating submersible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr.
(b) Capacitor for 2.5/4MFD
(c) Capacitor for 5/6 MFD.
(d) Front panel repair of dimension as per existing size suitable for desert cooler of capacity 4000/5000/6000 Cum per hrs
(e) PVC Flexible hose suitable for desert cooler cooling system
(f) PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample
(h) Bolt, nut with washers as per sample
(j) PVC Connector i.e (Elbow, Tee,3 way etc)
S&F top portion/cover of the desert cooler of the existing size.
S&F bottom portion/water storage tank of the existing size.
shivrefrigeration
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .