Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC Lowest valid tender | |
| 2 | L2₹13.4 L+₹1.5 L (12.3%)Rejected-AOC | L2 | Rejected-AOC Second lowest valid tender | |
| 3 | L3₹14.0 L+₹2.1 L (17.5%)Rejected-AOC | L3 | Rejected-AOC Third lowest valid tender |
Tender Value
Refer Docs
EMD Value
₹30,509
Closing Date
3 Jul 2024, 6:00 pmClosed
Assistant Executive Engineer
O/o the Assistant Executive Engineer, PWD Electrical Sub Division, Kozhikode
District Court Complex Kozhikode- SITC of Solar power in Bicentenary court - General Electrical Work
2024_PWD_677769_1
PWD/BLDG/TR/493/2024
Open Tender
Electrical Works
Item Rate
30 days
Kozhikode
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
₹30,509
25 Nov 2024
26 Jun 2024
6 Jul 2024
26 Jun 2024
3 Jul 2024
26 Jun 2024
Amount
ON grid solar
OD63039/2024-2025:Supply, Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystallin silicon solar cells, providing check metering ( energy meter) , necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 18%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) GTI of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The GTI shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections, Interconnections, supply and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply GTI unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. (Rate per KWp)( Make TATA solar Power/waaree energiesLtd/Vikram Solar/Havells/Renew sys solar)
OD210867/2023-2024:Supply and providing wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with trasperant front cover with hinged door and termination arrangement, b). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using suitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and DB fixing on wall using suitabel screws and plugs ets as required.
OD210868/2023-2024:Supply and providing wall mounted DC DB for on grid solar system for connecting 2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve incomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kA and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs ets as required.
OD210869/2023-2024:Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as required.
OD210870/2023-2024:Supply and crimping the Male Female MC4 Solar Panel cable connector including crimping and connecting etc as required
OD210873/2023-2024:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10Sqmm single run
OD210872/2023-2024:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB).
OD210874/2023-2024:Supplying and fixing HT Net meter (EM 3x110v -1A CI 0.25 Static LCD TOD facility & DLMS complaint HTCT/PT operated) in the existing meter board complete with connections, testing and commissioning etc. as required for charging On grid plant after dismantling the existing KWH meter (including testing if required, test certificate for submitting KSEB). Net metering system is to be provided to the solar consumer.
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD211685/2023-2024:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
OD210875/2023-2024:Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system.
OD210876/2023-2024:Supply and providing 25x3mm brass bolt
OD210877/2023-2024:Supply and providing 25x6mm brass bolt
OD210878/2023-2024:Supply and providing 12x3mm brass bolt
OD210879/2023-2024:Supply and providing Copper Bounded lightning arrester single spike " Air-termination rod " are placed on top of the structure using suitable base plate and nut bolt and giving connection to existing lightning down conductor etc as required
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.18:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
OD214607/2023-2024:Providing and fixing following capacity TP&N isolator switch disconnector unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 Amp TP & N
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
90.12.6.36:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 300 sq mm
9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Civil
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
SURESH.S
SOUBHAGYA ENGINEERING COMPANY
Bidder Name
SOUBHAGYA ENGINEERING COMPANY
All Star Electricals
SURESH.S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1053967.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .