Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.6 LAccepted-AOC | 1 | Accepted-AOC Being lowest and eligible bidder | |
| 2 | 2₹6.9 L+₹1.3 L (24.1%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹7.6 L+₹2.0 L (36.1%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹7.9 L+₹2.3 L (41.2%)Rejected-Finance | 4 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
REPAIR/MAINTENANCE OF INTERNAL WIRING AND CONNECTED WORKS IN SOUTHERN SECTOR AT MILITARY STATION KOTA
2020_MES_384387_1
8467/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Kota
Class E category a(i) and/or b(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹31,000
Yes
11 Dec 2020
7 Oct 2020
5 Nov 2020
7 Oct 2020
4 Nov 2020
21 Oct 2020
8 Oct 2020 - 14 Oct 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less then 20 mm width including all accessories, fixed on surface including making good disturbed surfaces, complete all as specified and directed for the following: - One light point controlled by one, one way switch of 5/6 Amps.
One ceiling /exhaust fan point controlled by one, one way switch of 5/6 Amps. Note : - Rate for connection of fan to ceiling rose with PVC insulated 3 core flexible copper wire in white colour shall be deemed included in the unit rates.
One 3 pin 5 Amp socket outlet point on the same board with other switches.
One 3 pin 5 amps socket outlet point on independent board.
One bell/buzzer point controlled by one bell push.
One light point controlled by two, 2-way switches of 5/6 amps.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surface, complete all as directed and specified.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC medium grade concealed conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and phenolic laminated sheet cover 3.0 mm thick and brass screws with cup washers including all necessary wall cutting and making good disturbed surface, complete all as specified and directed for the following: - One light point controlled by one, one way switch of 5/6 Amps.
One ceiling /exhaust fan point controlled by one, one way switch of 5/6 Amps. Note : - Rate for connection of fan to ceiling rose with PVC insulated 3 core flexible copper wire in white colour shall be deemed included in the unit rates.
One 3 pin 5 Amp socket outlet point on the same board with other switches.
One 3 pin 5 amps socket outlet point on independent board.
One bell/buzzer point controlled by one bell push.
One light point controlled by two, 2-way switches of 5/6 amps.
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLS of size 2.5 Sqmm stranded for earth continuity wire, to be drawn in PVC medium grade concealed conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and phenolic laminated sheet cover 3.0 mm thick and brass screws with cup washers for one socket outlet 15 amp on independent board including all necessary wall cutting and making good disturbed surface all as directed and specified. Note for item Nos. 6.10 to 6.60 & 7.00: Rate for wall cutting for switch/terminal boxes & chase cutting for concealing conduits and making good disturbed surfaces to match with the adjoining surface shall be deemed included in the unit rate.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, complete all as specified and directed.
S&F switch socket combination, 5 and 15 Amps, 230 volts, multi pin, flush type, universal, complete all as specified and directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, 2 way, complete all as specified and directed.
S&F switch socket combination, 5/6 Amps, 230 volt, multi pin, flush type, universal, complete all as specified and directed.
S&F Lamp Holder (ISI Marked) PVC/Polycarbonate body with back plate, suitable for batten fittings, complete all as specified and directed.
S&F Ceiling rose, surface bakelite, 65x20 mm, three terminal, complete all as specified and directed.
S&F Call bell AC 230 Volts, single pole, ding dong sound, complete all as specified and directed.
S&F bell push piano, flush type 5/6 Amps, 230 volts AC,single pole, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 4 Sqmm & earth continuity conductor of size 4 Sqmm, to be drawn through and including PVC casing and caping 20mm width on surface of walls/roof/floors for SPN DB's to switch boards, complete all as specified and directed. Note: - Two run of sub main wire, one run of earth wire and one run of PVC casing capping shall be measured as one unit.
M&L for Sub main wiring power/circuit using PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 6 Sqmm & earth continuity conductor of size 6 Sqmm, to be drawn through and including PVC conduit of dia not less than 25mm, medium Grade, concealed in walls/roof/floors, complete all as specified and directed.
M&L for Sub main wiring power/circuit using PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 10 Sqmm & earth continuity conductor of size 10 Sqmm, to be drawn through and including PVC conduit of dia not less than 25mm, medium Grade, concealed in walls/roof/floors, complete all as specified and directed. Notes for item No. 18 & 19: - (i) Two runs of sub main wire, one run of earth wire and one run of PVC conduit shall be measured as one unit. (ii) Rate for chase cutting for concealing PVC conduits and making good disturbed surfaces to match with the adjoining surface shall be deemed included in the unit rate.
Fixing only in replacement LED tube light fittings of any type and any wattage and connecting to ceiling rose, complete all as specified and directed. (LED tube light fittings shall be issued free for fixing under Schedule B)
Fixing only in replacement recess LED panel of any type & any wattage and connecting to ceiling rose, complete all as specified and directed. (LED recess panel shall be issued free for fixing under Schedule B)
Fixing only in replacement building security light of any type & any wattage and connecting the same, complete all as specified and directed. (Building security lights shall be issued free for fixing under Schedule B)
S&F MCB TPN DB made of sheet steel, phosphatised powder painted, with neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415 Volts AC with 4 way, Double door, complete all as specified and directed.
S&F MCB DB made of sheet steel, phosphatised powder painted, with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts AC, SPN with 8 way Double door, complete all as specified and directed. Notes for MCB DB - (1) The unit rate includes for cutting the brick walls to accommodate DB flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F MCB SPN 240 Volts, 'B' series, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed.
S&F MCB SP 240 Volts, 'B' series, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed.
S&F MCB TPN, 40 Amps, 415Volts, breaking capacity 16KA, 'B' Series, complete all as specified and directed.
S&F MCB TPN, 63 Amps, 415Volts, breaking capacity 16KA, 'B' Series, complete all as specified and directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead wire of 4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 15 mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI wire of 4 mm dia for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. (Earth lead wire and GI protection pipe beyond 7.50 m shall be measured and paid separately)
M&L for earth continuity conductor or main earthing lead GI wire of 4 mm dia, fixed to wall or on batten or recess or buried in ground or drawn in conduit pipe for earthing as required, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 200x150 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 250x200 mm and 50 mm deep, complete all as specified and directed.
K B ENTERPRISES
M/s Prem Associates
TARKESHWAR DASS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .