GEMC-511687751821057
Awarded to TOSHNIWAL INDUSTRIES PRIVATE LIMITED
₹1.8 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Thermal Imaging Camera | TIPL Ti1 | - | 3 NOS | ₹59,850 | 179,550 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.8 LQualified Make: TIPL
Model: TIPL Ti1 0 SRISHTI PLAZA COMMERCIAL PREMISES COOPERATIVE SOC SRISHTI PLAZA UNIT NO 011 GROUND FLOOR OFF SAKI VIHAR ROAD MUMBAI MAHARASHTRA 400072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | Make: TIPL
Model: TIPL Ti1 | L1 | Qualified | |
| 2 | Disqualified Make: Flir
Model: FLIR THERMAL IMAGING CAMERA TG165 259 EZRA STREET 32 EZRA STREET 2ND FLOOR ROOM 259 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | Make: Flir
Model: FLIR THERMAL IMAGING CAMERA TG165 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
27 Aug 2018, 5:00 pmClosed
thermal imager Thermal Imager ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type Hand held * Detector Resolution (minimum) (pixel) 14000 14000
19000
75000
100000 Temperature Range of Objects (Degree Celsius) -20 to +250 -20 to +250
20 to +350
20 to +500
+30 to +42 (for fever measurment & animal husbandry thermal imager) Temperature measuring accuracy of reading (or better) ± 2% oC ± 0.3% oC (for fever measurment & animal husbandry thermal imager)
± 2% oC
± 5%oC Minimum Focus distance 20 10
20
65 Image capture frequency/frame rate (Hz) N ≥ 9 * Image Detector Type Uncooled focal plane array (FPA)Vox Asi/BST/Silicon * 1/5 Thermal sensitivity (NETD) 0.1 0.05-0.2 User selectable Emissivity setting/correction Between 0.01 and 1 * Infrared spectral band (micrometer) Between 8 and 14 * Image Palettes 5 * LENS MEASUREMENTS FEATURES Horizontal Field of View of Standard lens (degree) 31-35 * Vertical Field of View of Standard lens 35-40 * Horizental Field of View of Telephoto lens NA 9-12
13-15
15-20
20-25
NA Vertical Field of View of Telephoto lens NA 7-12
15-21
20-26
NA IFOV of Standard lens (mRad) 4 * IFOV of Telephoto Lens (mRad) NA 0.5
0.65
0.7
0.75
0.87
1
NA IFOV of (Spatial resolution) (mRad) 2 * DISPLAY Display Type Color LCD Color LCD
Color LED Display size 3.2 3-10 GENERAL FEATURES Image capture
review and save mechanism One handed image capture
review and save capability * Storage medium USB stick * Size of USB stick 2 * File formats JPEG
BMP
GIF
PNG
TIFF * Built-in digital camera/Visual Camera Resolution (Mpixel) N ≥ 0.5 N ≥ 0.5
N ≥ 1
NA Details of Operating functions Easy Touch And Simple Toggle Button * Facility for the adjustment/selection of the time/date etc yes * Interface for image transfer USB Cable with suitable drivers for downloading to PC * Focus Auto * 2/5 other features - * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 50 * Operating Humidity (RH) 90 * POWER REQUIREMENT Power Requirements Battery Operated * chemistry of the battery lithium ion * Voltage of rechargeable Battery 12 * Capacity of rechargeable battery (milliAH) 1800 * Suitable charger/adapter provided NA * Battery Backup 3 * Power Management Automatic shut down User Selectable * On-screen battery level indicator yes * CERTIFICATION & SAFETY IP Protection IP54 * Safety certification UL
CE * GENERIC Size/dimension - * Weight (including batteries) 485 * Automatic active temperature stabilization system of camera yes * Provision for through- the-lens direct temperature measurement capability yes * TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true * Availability of the test report from Central Govt/NABL/ILAC accredited lab to prove conformity to the specification false * Test Report Number and date for the specification test (not a part of biddable parameter) - * Name and address of the Lab for the specification test (not a part of biddable parameter) - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mukesh Kumar 743145
Halishahar store depot 3 15
513325
GEM/2018/B/72837
GeM Contract
thermal imager
GeM Contract
15 days
West Bengal; 24 Paraganas North
PRODUCT
Awarded to TOSHNIWAL INDUSTRIES PRIVATE LIMITED
₹1.8 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Thermal Imaging Camera | TIPL Ti1 | - | 3 NOS | ₹59,850 | 179,550 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| thermal imager Thermal Imager ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type Hand held * Detector Resolution (minimum) (pixel) 14000 14000 | - | - | - |
| 19000 | - | - | - |
| 75000 | - | - | - |
| 100000 Temperature Range of Objects (Degree Celsius) -20 to +250 -20 to +250 | - | - | - |
| 20 to +350 | - | - | - |
| 20 to +500 | - | - | - |
| +30 to +42 (for fever measurment & animal husbandry thermal imager) Temperature measuring accuracy of reading (or better) ± 2% oC ± 0.3% oC (for fever measurment & animal husbandry thermal imager) | - | - | - |
| ± 2% oC | - | - | - |
| ± 5%oC Minimum Focus distance 20 10 | - | - | - |
| 20 | - | - | - |
| 65 Image capture frequency/frame rate (Hz) N ≥ 9 * Image Detector Type Uncooled focal plane array (FPA)Vox Asi/BST/Silicon * 1/5 Thermal sensitivity (NETD) 0.1 0.05-0.2 User selectable Emissivity setting/correction Between 0.01 and 1 * Infrared spectral band (micrometer) Between 8 and 14 * Image Palettes 5 * LENS MEASUREMENTS FEATURES Horizontal Field of View of Standard lens (degree) 31-35 * Vertical Field of View of Standard lens 35-40 * Horizental Field of View of Telephoto lens NA 9-12 | - | - | - |
| 13-15 | - | - | - |
| 15-20 | - | - | - |
| 20-25 | - | - | - |
| NA Vertical Field of View of Telephoto lens NA 7-12 | - | - | - |
| 15-21 | - | - | - |
| 20-26 | - | - | - |
| NA IFOV of Standard lens (mRad) 4 * IFOV of Telephoto Lens (mRad) NA 0.5 | - | - | - |
| 0.65 | - | - | - |
| 0.7 | - | - | - |
| 0.75 | - | - | - |
| 0.87 | - | - | - |
| 1 | - | - | - |
| NA IFOV of (Spatial resolution) (mRad) 2 * DISPLAY Display Type Color LCD Color LCD | - | - | - |
| Color LED Display size 3.2 3-10 GENERAL FEATURES Image capture | - | - | - |
| review and save mechanism One handed image capture | - | - | - |
| review and save capability * Storage medium USB stick * Size of USB stick 2 * File formats JPEG | - | - | - |
| BMP | - | - | - |
| GIF | - | - | - |
| PNG | - | - | - |
| TIFF * Built-in digital camera/Visual Camera Resolution (Mpixel) N ≥ 0.5 N ≥ 0.5 | - | - | - |
| N ≥ 1 | - | - | - |
| NA Details of Operating functions Easy Touch And Simple Toggle Button * Facility for the adjustment/selection of the time/date etc yes * Interface for image transfer USB Cable with suitable drivers for downloading to PC * Focus Auto * 2/5 other features - * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 50 * Operating Humidity (RH) 90 * POWER REQUIREMENT Power Requirements Battery Operated * chemistry of the battery lithium ion * Voltage of rechargeable Battery 12 * Capacity of rechargeable battery (milliAH) 1800 * Suitable charger/adapter provided NA * Battery Backup 3 * Power Management Automatic shut down User Selectable * On-screen battery level indicator yes * CERTIFICATION & SAFETY IP Protection IP54 * Safety certification UL | - | - | - |
| CE * GENERIC Size/dimension - * Weight (including batteries) 485 * Automatic active temperature stabilization system of camera yes * Provision for through- the-lens direct temperature measurement capability yes * TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true * Availability of the test report from Central Govt/NABL/ILAC accredited lab to prove conformity to the specification false * Test Report Number and date for the specification test (not a part of biddable parameter) - * Name and address of the Lab for the specification test (not a part of biddable parameter) - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mukesh Kumar 743145 | - | - | - |
| Halishahar store depot 3 15 | - | - | - |
Exempted
28 Aug 2018
24 Aug 2018
contract_GEMC-511687751821057.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_513325.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .