Loading…
Loading…
Tender ID
Tender Value
₹21.1 Cr
EMD Value
₹21.1 L
Closing Date
25 Mar 2026, 6:00 pmClosed
Executive Engineer’s office, Valsad (R&B) Division,
Construction of Science College at Kalgam Ta. Umergam Dist. Valsad
285978
44 Of 2025-26
Open
Civil - All
Works
Valsad
19 documents required · 19 mandatory
₹18,000
Yes
Executive Engineer,Valsad (R&B) Division, Valsad
₹21.1 L
Yes
13 Mar 2026
13 Mar 2026
13 Mar 2026
25 Mar 2026
13 Mar 2026
No figures
1 Excavation for foundation upto 1.5 m depth including sorting out 6383.00 Cumt 117.09
and stacking of useful materials and disposing off the excavated
stuff upto 50 Meter lead.(A) Loose or soft soil
2 Excavation for foundation upto 1.5 to 3 m depth including sorting 2068.00 Cumt 162.56
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(C) Dense or Hard soil
3 Filling in foundation and plinth with sand in layers of 20 cm. 439.00 Cumt 460.19
Thickness including watering ramming and consolidating etc.
layer of 20 cm in thickness including ramming watering and
consolidating etc. complete
5 Anti-Termite System:Providing and laying of permanent piping 2151.00 Sqmt 63.63
technology anti-termite treatment before flooring work by
installing LLDP (Low linear density polyethylene) tube of 8 mm
O.D. & 6.4 mm 1.D. with inbuilt pressure compensation chip every
30 cm interval in the tube, having working pressure of 2 Kg/cm2
and release rate of 1.9 Itr/hour fixed by P-clips and nails. The
LLDP pipe shall be installed at the entire periphery of the building
and at internal network of building at a depth of 20 to 200 mm
under floor at every 2 to 3 mtr. c/c distance (adjusted as per
building layout ) & Ends of loop pass through a PVC elbow of
minimum 32 mm ID at junction box of wall and floor level,
entering into a steel reinforced grooved flexible pipe of minimum
22 mm ID leading into junction box and the loops shall terminate
in junction boxes & test every junction during injecting chemicals
for termite control treatment. The anti termite chemical
Imidacloprid 30.5% SC mix as per IS- 6313 (part III) shall be
injected by the pressure pump diluted with water @ 10.5 ml/5 ltr
of water at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The contractor
shall submit approved line plan for piping system and junction
boxes dully approved by Engineer-in-Charge with bond of 5 year
warranty.(II)Anti Termite chemical injected area (Chemical
injecting incl. labour cost)
6 Providing and laying controlled cement concrete M.150 and 1036.00 Cumt 3894.06
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (A) Foundations
and plinth pcc
7 Providing and laying controlled cement concrete M.250 and 2735.61 Cumt 4590.45
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (A) Foundations,
footings, and Mass concrete. footing
8 Providing and laying controlled cement concrete M-250 and 53.00 Cumt 7429.56
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in (d) columns
Up to Plinth level.
9 Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse 444.00 Cumt 3005.76
sand : 6- machine cut stone aggregates 40 mm nominal size) and
curing complete excluding cost of formwork in (A) Foundation
and Plinth
Item Rate In
Description of Item Quantity Unit Amount
No figures
10 Providing and laying controlled cement concrete M-200 and 163.00 Cumt 7403.30
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in Columns,
pillars posts and struts G.FLOOR
11 Providing and laying controlled cement concrete M-200 and 66.00 Cumt 7403.30
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in Columns,
pillars posts and struts F.FLOOR
12 Providing and laying controlled cement concrete M-200 and 66.00 Cumt 7443.70
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in Columns,
pillars posts and struts S.FLOOR
13 Providing and laying controlled cement concrete M-200 and 30.00 Cumt 7484.10
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in Columns,
pillars posts and struts T.FLOOR
14 Providing and laying controlled cement concrete M-250 and 459.02 Cumt 4832.62
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in Ground &
Plinth BEAMS
15 Providing and laying controlled cement concrete M-150 and 330.50 Cumt 5160.09
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in plinth Slab
16 Providing and laying controlled cement concrete M.200 and 354.00 Cumt 6122.62
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (C) Ground floor
17 Providing and laying controlled cement concrete M.200 and 317.00 Cumt 6122.62
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (C) F.floor Beams,
18 Providing and laying controlled cement concrete M.200 and 319.00 Cumt 6162.01
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (C) S floor Beams,
19 Providing and laying controlled cement concrete M.200 and 8.00 Cumt 6202.41
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (C) T floor Beams,
20 Providing and laying controlled cement concrete M-200 and 12.00 Cumt 6725.59
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Chhajja for
Ground floor
21 Providing and laying controlled cement concrete M-200 and 10.00 Cumt 6725.59
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Chhajja for First
22 Providing and laying controlled cement concrete M-200 and 11.00 Cumt 6765.99
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Chhajja for
second floor
23 Providing and laying controlled cement concrete M-200 and 1.00 Cumt 6806.39
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Chhajja for
third floor
24 Providing and laying controlled cement concrete M-200 and 13.00 Cumt 8499.15
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Lintal for
Ground floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
25 Providing and laying controlled cement concrete M-200 and 10.00 Cumt 8499.15
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Lintal for First
26 Providing and laying controlled cement concrete M-200 and 11.00 Cumt 8539.55
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Lintal for
Second floor
27 Providing and laying controlled cement concrete M-200 and 7.00 Cumt 8579.95
curing etc. complete including the cost of form work and
reinforcement for reinforced concrete work in (c) Lintal for Third
28 Providing and laying controlled cement concrete M.200 and 295.50 Cumt 6502.38
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (C) Ground floor
29 Providing and laying controlled cement concrete M.200 and 281.00 Cumt 6502.38
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in (C) First Floor slab
30 Providing and laying controlled cement concrete M.200 and 281.00 Cumt 6542.78
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in Second Floor slab
31 Providing and laying controlled cement concrete M.200 and 9.00 Cumt 6583.18
curing complete including the cost of formwork and excluding
reinforcement for reinforced concrete work in Third Floor slab
32 Providing and laying controlled cement concrete M-200 and 15.00 Cumt 6973.04
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in (E) Stair case
for Ground Floor to first floor
33 Providing and laying controlled cement concrete M-200 and 7.00 Cumt 6973.04
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in (E) Stair case
for First Floor to Second floor
34 Providing and laying controlled cement concrete M-200 and 7.00 Cumt 7012.43
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in (E) Stair case
for Second to third floor
35 Providing and laying controlled cement concrete M-200 and 5.00 Cumt 8722.36
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in RCC Vertical
and horizontal wall for Below Plinth & Ground floor
36 Providing and laying controlled cement concrete M-200 and 48.00 Cumt 8722.36
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in RCC Vertical
and horizontal wall for G.floor
37 Providing and laying controlled cement concrete M-200 and 8.00 Cumt 8761.75
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in RCC Vertical
and horizontal wall for F.floor
38 Providing and laying controlled cement concrete M-200 and 8.00 Cumt 8761.75
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in RCC Vertical
and horizontal wall for S.floor
39 Providing and laying controlled cement concrete M-200 and 8.00 Cumt 8802.15
curing etc. complete including the cost of form work and
excluding the cost of reinforcement etc. complete in RCC Vertical
and horizontal wall for T. floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
40 Providing and fixing 90 cm high Stainless steel railing made from 44.00 Rmt 3719.83
anticorrocive 304 grade S S pipe of 50 mm dia (16Gauge) as hand
rail with S S 304 grade Baluster of 38 mm dia (16Gauge) as a
vertical support fixed in RCC slab at 1.2m c/c including three
horizontal S S pipes of 25 mm dia (16Gauge) at eqal distance fixed
by 18.75 mm dia (16Gauge) S S pipe with baluster including
accessories as per detailed drawing as directed etc. complete.
41 Providing and Fixing S.S Hand Rail made SS 304 of 50 mm inside 225.00 Rmt 1532.37
dia 16 guage round pipe supported with 8 mm thick SS 304 base
flange on wall including end S.S ball 75mm dia, anchor fasteners,
nuts, accessories as per detailed drawing etc. complete as
directed by Architect or Engineer in charge.
42 Providing TMT Bar FE 550D reinforcement for R.C.C. work 756242.00 Kg 95.26
including bending, binding and placing in position complete upto
floor top level
43 Providing and fixing eco-friendly light weight calcium silicate 1071.00 Sqmt 1648.96
false ceiling tiles having Tegular edge & 15 mm Thick Densified
edges on the Tile Periphery for Extra Strength The Light weight
calcium silicate ceiling tiles shall have, light reflection 85% non-
combustible as per B.S. 476 part IV, 100% humidity resistance
and also having thermal conductivity0.043° w/m KC.for the best
thermal Insulation. The Light weight calcium Silicate tile shall be
of approved texture Fine fissured/ Spintone/ Cosmos having NRC
value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent
of size 595 X 595 mm to be laid on true horizontal level
suspended inter locking metal grid of hot dipped galvanized steel
sections (galvanizing @120 grams per sqm including both side)
consisting of main ‘T’ runner suitably spaced at joints to get
required length and size of 24 X 38mm made from 0.30 mm thick
(minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size
24 X 28mm made out of 0.33mm (Minimum) sheet spaced
1200mm along spaced between main 'T' at 600mm centre to
centre to form agrid of 1200x600mm and size 24x48mm made of
0.30mm thick (Minimum) sheet to be interlocked at middle of the
1200x600mm panel to form grid of size 600x600mm resting on
periphery walls/partitions on a perimeter wall angle pre-coated
steel of size (24x24x3000mm made of 0.40mm thick (minimum)
sheet with the help of rawl plugs at 450mm centre to centre with
25mm long dry wall screws @ 230mm interval and laying 15mm
thick densified edges light weight calcium silicate ceiling tiles of
approved texture (Fine fissured/Cosmos/Spintone) in the grid
including cutting/making opening for services like diffusers, grills,
light fittings, fixtures, smoke dtectors etc., wheneveer required,
Main 'T' runners to be suspended from ceiling using G.I. slotted
cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and
44 Brick work using common burnt clay building bricks having 405.00 Cumt 4021.02
crushing strength not less than 35 kg/sq.cm. in foundation and
plinth in cement mortar 1:6 (1 cement : 6 fine sand) Conventional
45 Brick work using common burnt clay building bricks having 645.00 Cumt 4295.99
crushing strength not less than 35 Kg/Sq.cm. in super structure
above plinth level upto floor two level in cement mortar 1:6
(1cement : 6 fine sand) Conventional {Ground FLoor}
46 Brick work using common burnt clay building bricks having 381.00 Cumt 4295.99
crushing strength not less than 35 Kg/Sq.cm. in super structure
above plinth level upto floor two level in cement mortar 1:6
(1cement : 6 fine sand)Conventional {First FLoor}
Item Rate In
Description of Item Quantity Unit Amount
No figures
47 Brick work using common burnt clay building bricks having 312.00 Cumt 4336.18
crushing strength not less than 35 Kg/Sq.cm. in super structure
above plinth level upto floor two level in cement mortar 1:6
(1cement : 6 fine sand)Conventional {Second FLoor}
48 Brick work using common burnt clay building bricks having 74.00 Cumt 4376.37
crushing strength not less than 35 Kg/Sq.cm. in super structure
above plinth level upto floor two level in cement mortar 1:6
(1cement : 6 fine sand)Conventional {third FLoor}
49 Half brick masonry in common brunt clay building bricks having 650.00 Sqmt 653.01
crushing strength not less than 35Kg/Sm. In C.M 1:4( 1cement :
coarse sand) in super structure. Conventional for Ground floor..
50 Half brick masonry in common brunt clay building having 679.00 Sqmt 653.01
crushing strength not less than 35Kg/Sm. In C.M 1:4( 1cement :
coarse sand) in super structure.Conventional for first floor.
51 Half brick masonry in common brunt clay building having 530.00 Sqmt 659.00
crushing strength not less than 70Kg/Sm. In C.M 1:4( 1cement :
coarse sand) in super structure.Conventional for Second floor.
52 Half brick masonry in common brunt clay building having 147.00 Sqmt 665.00
crushing strength not less than 35Kg/Sm. In C.M 1:4( 1cement :
coarse sand) in super structure.Conventional for Third floor.
53 Providing and fixing 150 mm wide, approved quality chicken wire 2723.00 Sqmt 360.77
mesh at junction of brick work and RCC work or two dissimilar
surfaces, at all heights fixed by nails, rowal plugs or tag by cement
mortar 1:3 before applying the plaster, including curing, s
54 Providing 15mm thick Smooth cement plaster in single coat on 3980.00 Sqmt 201.40
Rough (Similar) side of single or half birck walls / concrete wall
for interior plastering and finished even and smooth in C M 1:4 (1
cement : 4 coarse sand) with floting coat of neat cement slurry
etc. comp. For Ground floor
55 Providing 15mm thick Smooth cement plaster in single coat on 4047.00 Sqmt 201.40
Rough (Similar) side of single or half birck walls / concrete wall
for interior plastering and finished even and smooth in C M 1:4 (1
cement : 4 coarse sand) with floting coat of neat cement slurry
etc. comp. For first floor
56 Providing 15mm thick Smooth cement plaster in single coat on 4165.00 Sqmt 224.80
Rough (Similar) side of single or half birck walls / concrete wall
for interior plastering and finished even and smooth in C M 1:4 (1
cement : 4 coarse sand) with floting coat of neat cement slurry
etc. comp. For second floor
57 Providing 15mm thick cement plaster in single coat on Rough 439.00 Sqmt 248.19
(Similar) side of single or half birck walls / concrete wall for
interior plastering and finished even and smooth in C M 1:4 (1
cement : 4 coarse sand) with floting coat of neat cement slurry
etc. coThird floor
58 Providing 10 mm. Thick smooth cement plaster in single coat for 2091.00 Sqmt 189.15
plastering on ceiling and soffits of stairs and finished even and
smooth in : (I) Cement mortar 1:4 (1 cement : 4 sand) with floting
coat of neat cement slurry etc. complete.Ground Floor
59 Providing 10 mm. Thick smooth cement plaster in single coat for 1948.00 Sqmt 189.15
plastering on ceiling and soffits of stairs and finished even and
smooth in : (I) Cement mortar 1:4 (1 cement : 4 sand) with floting
coat of neat cement slurry etc. complete. First Floor
60 Providing 10 mm. Thick smooth cement plaster in single coat for 1944.00 Sqmt 212.54
plastering on ceiling and soffits of stairs and finished even and
smooth in : (I) Cement mortar 1:4 (1 cement : 4 sand) with floting
coat of neat cement slurry etc. complete second Floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
61 Providing 10 mm. Thick smooth cement plaster in single coat for 64.00 Sqmt 235.94
plastering on ceiling and soffits of stairs and finished even and
smooth in : (I) Cement mortar 1:4 (1 cement : 4 sand) with floting
coat of neat cement slurry etc. complete third Floor
62 20mm thick double coat sand faced cement gutka plaster on walls 10518.00 Sqmt 300.66
upto height 10 metres above ground level consisting of 12mm
thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick
finishing coat of C.M. 1:1 (1-cement : 1-sand) including 1cm x 1cm
grooves etc. complete.
63 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 737.00 Rmt 42.17
64 Applying two coats of (white cement based) or (acrylic lappy 18337.00 Sqmt 40.59
(putty)) or equivalent and two coats of primer of approved brand
and manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth. for
All floor.
65 Wall painting (two coats) with plastic emulsion paint of approved 12294.00 Sqmt 80.35
brand and manufacture on undecorated wall surface to give an
even shade including throughly brushing the surface free from
mortar droppings and other foreign matter and sand papered
66 Wall painting (two coats) with plastic emulsion paint of approved 6043.00 Sqmt 85.76
brand and manufacture on undecorated ceiling surface to give an
even shade including throughly brushing the surface free from
mortar droppings and other foreign matter and sand papered
67 Finishing wall with Weather proof exterior 100% acrylic 10493.00 Sqmt 114.53
emulsion paint With one coat of primer on wall surface to give an
required shape even shade after thoroughly brushing the surface
to remove all dirt, and remains of loose powdered materials.etc
complete for All floor
68 Providing And filling with good quality cinder(steam coal) as 104.00 Cumt 691.85
directed by engineer in charge in sunks in layers of 15 cm
thick,including watering,placing ,ramming well etc as directed, for
all floor.
69 Providing and laying water proofing treatment by conventional 148.00 sqmt 1005.96
method including cleaning the slab surface by wire brush as
directed including provding first layer of C.M. 1:4 of 40 mm
thickness mixed with water proofing compound at rate
prescribed by manufacturer, including putting of brick bats of
average thickness 40 mm Well immerssed in water laid uniformly
on first layer of mortar including applying cement slurry @ rate of
0.08 bag/sqm. on fixed layer of brick bats including maintaining
necessary slope, in second layer 40 mm thick C.M 1:4 mixed with
water proofing compound as directed, including finishing smooth
with cement slurry as directed complete.
70 Providing and laying controlled cement concrete M-200 for RCC 69.75 Cumt 5283.31
work and curing complete including the cost of form work but
excluding the cost of reinforced concrete work in coping on
Ground Floor
71 Providing and laying controlled cement concrete M-200 for RCC 7.00 Cumt 5283.31
work and curing complete including the cost of form work but
excluding the cost of reinforced concrete work in coping on First
72 Providing and laying controlled cement concrete M-200 for RCC 5.00 Cumt 5323.71
work and curing complete including the cost of form work but
excluding the cost of reinforced concrete work in coping on
Second Floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
73 Providing and laying controlled cement concrete M-200 for RCC 11.00 Cumt 5364.11
work and curing complete including the cost of form work but
excluding the cost of reinforced concrete work in coping on third
74 Providing and fixing window having extruded aluminumColour 15.00 Sqmt 2140.33
anodized section frame main outer size 127mm x38.10mm x
1.35mm @wt. 1.384kg/m, horizontal Four track member size
122.20mm x 31.75mm x 1.10mm@ wt1.205 kg/m, vertical
member of size 122.20mm x31.75mm x 1.50mm @1.398 kg/mt
with sliding shuttersof horizontal member size 40mm x 18mm x
[email protected]/mt ,vertical member of size 40mm x 18mm
x1.29mm @ 0.456 kg/mt with 5 mm thick transparentbronze
colour tinted float glass with powder coatedaluminum fittings
and fixtures and transparent siliconsealant glass fixing to frame as
per details etc completefor window
75 Providing and fixing window having extruded aluminumColour 262.00 Sqmt 1583.95
anodized section frame main outer size 95mm x24mm x 1.17mm
@ wt.of 0.738 Kg/mt , horizontal Three track member size 92mm
x 31.75mm x 1.30mm,@Wt.1.07 Kg/mt , vertical member of size
92mm x31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with
slidingshutters of horizontal member size 40 mmx18mmx1.29mm
@ wt.of 0.456 Kg/mt, vertical member of size40mm x 18mm x
1.29 mm @ wt.of 0.456Kg/mt/ with 5mm thick transparent
bronze colour tinted float glasswith powder coated aluminum
fittings and fixtures andtransparent silicon sealant glass fixing to
76 frame as perdetails
Providing etc
& Fixing in position standard extruded approved colour 163.00 Sqmt 3004.75
anodised Aluminum Ventilator with outer frame 63.50 x 38.10 x
1.95 mm @ Wt 1.094 kg/Rmt with 3mm thick Bajari figure
adgesteble tinted louvers glass fixed to alluminium strip blade
including fixtures, fastenning, labours and equipments as per
detailed drawing as directed. For Ventilators W3 V1 V3
77 Providing & Fixing in position standard extruded approved colour 17.00 Sqmt 3336.03
anodised Aluminum Ventilator with outer frame 63.50 x 38.10 x
1.95 mm @ Wt 1.094 kg/Rmt with 6mm thick Dark glass pannel
fixed to alluminium strip blade including fixtures, fastenning,
labours and equipments as per detailed drawing as directed. For
Ventilators V2
78 Providing and fixing 38 mm thick flush double door shutter, solid 226.00 Sqmt 4673.27
core with Anodized Aluminium section (jindal door section no
19552-weight not less than 1.1 kg/mt ) frame size 63.5mm x
38mm inserted Non teak wood frame inside the aluminium
section for durable grip of hinges & Double shutter with
required teakwood batten having 1mm thick lamination on both
side, Durable Grip shall be providing with both side 15cm long
stainless steel handle and necessary Locking system of Godrej,
,fixtures & fastenings etc. directed by engineer in charge. D1
79 Providing and fixing 38 mm thick flush single door shutter, solid 45.00 Sqmt 4628.83
core with Anodized Aluminium section (jindal door section no
19552-weight not less than 1.1 kg/mt ) frame size 63.5mm x
38mm inserted Non teak wood frame inside the aluminium
section for durable grip of hinges & Double shutter with
required teakwood batten having 1mm thick lamination on both
side, Durable Grip shall be providing with both side 15cm long
stainless steel handle and necessary Locking system of Godrej,
,fixtures & fastenings etc. directed by engineer in charge. D,D3
Item Rate In
Description of Item Quantity Unit Amount
No figures
80 Providing and fixing FRP frame size 100 x 50 mm and 35 mm 46.00 Sqmt 2362.39
thick FRP depress panel single/Double shutter having extra
reinforcement on sides & edges in Gel coat finish.The core of the
shutter & frame is to be filed up with injected fire retradat grade
polyurethene foam done in situ along with embeded wooden
pieces for stiffening & also taking hinges & fintures.The whole FRP
frame & shutter is to be waterproof, weatherproof ,termite proof
& resistance to mild acid/alkali.Rates are to be inclusive of S.S
hinges with necessary screws & alluminum fixtures & fastenings
& fartener sleeve.Colour and Shade approved by Engineer-In-
Charge.D5,
81 P & L 60x60 cm Mirror polished Blue Kota Stone slab flooring 5144.00 Sqmt 1029.22
over 20 mm (average)thick base of cement mortar 1:6 (1-cement
6-coarse sand) or L.M 1:1.5 (1 Lime putty : 1.5 coarse sand laid
over and jointed with grey cement slurry mixed with pigment to
match the shade of slab including rubbing and polishing
etc.complete (A) 30mm thick
82 P & L 60x60 cm Mirror polished Blue Kota Stone slab 30 mm 189.00 Sqmt 1089.67
thick in riser of steps,skirting dedo and pillars laid on 10 mm
thick cement mortar 1:3 (1-cement 3-coarse sand) and jointed
with grey cement slurry mixed with pigment to match the shade
of slab including rubbing and polishing etc.complete(30 mm thick)
83 P & L Mate Finished antiskid ceramic tiles 30 x 30 cm size 6 mm 213.00 Sqmt 970.07
thick in flooring treads of steps and landing laid on a bed of
mm thick cement mortar 1:3(1-cement:3-coarse sand)finishing
with flush pointing in white cement
84 P & L premium printed glazed tiles tiles size 30 x 60 cm 6 mm 587.00 Sqmt 1441.22
thick in skirting risers of steps and dedo on 10 mm thick cement
plaster 1:3 (1-cement:3coarse sand) and jointed with colour
cement slurry
85 Providing and laying machine cut free edge machine polished 173.00 Sqmt 929.20
Blue kota stone 25mm thick finished treads and risers in Max
cm length with 1cm projecting, nozing rounded moulding in tread
laid over 12 mm (av.) thick bases of cement mortar 1:6 (1-cement
: 6-coarse sand) jointed with grey or colour cement slurry
including rubbing and polishing incl. making Three No.s of
grooves of size 3mm X 3mm along the length of treads etc.
86 Providing Plinth Protection to Building including excavation in 452.00 Sqmt 2402.49
ordinary soil and laying cement concrete 1:3:6 using stone
aggregates of 40mm nominal size in foundation layer 125 mm
thick+ 125mm thick sand layer below pre-cast Rubber Dye inter
locking concrete block 60mm thick with grade of concrete M300
pneumatic compressed by mechanically pressed and as per
approved design including 75mm Sand layer for levelling and
filling the joint with sand in proper line and level etc. complete,
Including Providing and fixing pre-cast concrete kerb stone of
grey cement based concrete block 30cm length, 30cm height and
15cm thick made of M250 grade concrete as per approved design
and including excavation for fixing in proper line and level, filling
the joint with C:M 1:3 (1cement:3 fine sand) etc. complete.
87 Providing and laying broken chine mosaic flooring for terrace 2188.00 Sqmt 747.29
using 12 mm to 20 mm broken pieces of glazed tiles to be laid
over cement mortar 1:3 to plain or slope and to be tempered to
bring mortar creme out upto surface using white cement
including rounding off junctions and extending them upto 15 cm
along the wall,clearing with water and oxalic acid etc. as directed
Item Rate In
Description of Item Quantity Unit Amount
No figures
88 Providing and laying cement concrete flooring 1:2:4 (1-cement : 2- 2188.00 Sqmt 322.93
coarse sand : 4-graded stone aggregate 20mm nominal size) laid
in one layer and finished with a floating coat of neat cement. (A)
50mm thick.
89 Providing and fixing mirror polished 18 mm thick Green Marble 830.00 Sqmt 1317.04
stone with full round edge and polished of approved quality in
clading on sill and around the doors/ windows/ ventilation with
20 mm thick cement plaster CM (1:4) and fixing with cement
slurry & adhesive including moulding of exposed edges as
directed by engineering in charge etc. complete.
90 Providing and fixing M.S Safty Grills having 16mm MS bar 458.00 Sqmt 3392.59
Horizontally at every equal 0.10m C/C distance and 2 no of bar
Vertically at every equal 0.375m C/C distance Fixing on around
(5x40) mm Solid MS Patti including cutting, welding and
fabrication etc; including one coat of primer of approved quality
and two coats of oil painting as per detail drawing etc. complete
as per directed Engineer in charge.
91 Providing erecting and fixing double coated Syntex PVC. (ISI) 15000.00 Litre 3.95
water tank of required capacity each with all necessary fittings
and connection etc. complete on terrace.
92 Providing laying and jointing in true line and level 50mm dia. 180.00 Rmt 195.67
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
93 Providing laying and jointing in true line and level 40mm dia. 120.00 Rmt 148.12
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
94 Providing laying and jointing in true line and level 25mm dia. 180.00 Rmt 91.84
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
95 Providing laying and jointing in true line and level 15mm dia. 180.00 Rmt 72.65
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Item Rate In
Description of Item Quantity Unit Amount
No figures
96 Providing, laying and jointing in true line and level 160 diametre 120.00 Rmt 831.22
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size 160 mm
diametre x 210 mm length x 196 mm heigh at every 2000 mm
center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
97 Providing laying (to level or slopes) and jointing reinforced 571.00 Rmt 665.48
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared
for collar joints including testing of joints complete.(D)
98 Providing, laying and jointing in true line and level 110 diametre 685.04 Rmt 836.73
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size 110 mm
diametre x 149 mm length x 145 mm heigh at every 2000 mm
center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
99 Providing, laying and jointing in true line and level 75 mm dia. 120.00 Rmt 292.90
UPVC SWRType B pipe conforming to IS 13592-1992 with one
end plain and other end socketed with rubbering and fitting
conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of PVC clamp at
every 2000 mm c/c or shall be conceled in walss as directed
including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
100 Providing and fixing in PVC SWR cowel went 75mm dia to 4.00 No 15.66
pipes.(B) 75mm dia.
101 Providing and fixing in PVC SWR cowel went 110mm dia to 11.00 No 28.79
pipes.(B) 110mm dia.
102 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 42.00 No 571.08
mm diameter with jali of the following nominal diameter of self
cleansing design with C.I scread down or hinged grating including
the cost of cutting and making good the walls.
103 Providing and fixing wash down water closet (European type W C 18.00 No 2951.22
pan) with integral P and S trap including jointing the trap with
soil pipe in cement mortar 1:1 (1 cement five sand) including
providing and fixing plastic seat cover for wash down WC with CP
brass hinges and rubber buffers back plastic seat and including
providing and fixing PVC flushing tank with a pair of C I or MS
bracket with complete fitting such as lead valve siphon 15 mm dia
brass ball valve with polythene float CP brass handle unions and
couplings for connection with inlet out let and over flow pipes
mm dia porcelain enameled flush bend including cutting holes in
walls and making good the same connection the flush bend with
cistern and closet vitreous china.
Item Rate In
Description of Item Quantity Unit Amount
No figures
104 Provision and fixing water closet squatting orissa type W.C. pan 6.00 No 1607.92
size 580mm integral footrest and 100 mm P or S trap and in
cluding 25 mm dia CP brass flush valve and GI inlet connection
etc. comp. (A) Vitreous china long pattern white or color
105 Providing and fixing brass screw down stop tap.(A) 15mm dia. 24.00 No 205.83
106 Providing and fixing ball cock of approved. quality as directed.(A) 3.00 No 189.84
Copper Metal (ii) 50mm dia.
107 Providing and fixing washbasin with single hole for pillar tap with 18.00 No 1506.45
C.I. or M.S. brackets painted white including sutting holes and
making good the same but excluding fittings.(A) Vitreous
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In
108 white colour.
Providing and fixing C.P. brass waste for washbasin or sink. (A) 18.00 No 67.91
109 Providing and fixing M.I. fisher union for washbasin or sink. (A) 18.00 No 78.75
110 Providing and fixing 600mm x 450mm bevelled edge mirrror of 18.00 No 833.73
superior glass mounted on 6mm thick A.C. sheet or plywood sheet
and fixing to wooden pluge with C.P. brass screws and washers.
111 Providing and fixing C.P. brass towel rail comlete with C.P. brass 18.00 No 603.19
brackets fixed to wooden plugs with C.P. brass scews (B) 600mm
x 20mm size.
112 Providing and fixing screw down bib taps of following size.(A) 54.00 No 214.81
Brass screw down bib tap polished bright. (i) 20mm dia.
113 Providing and fixing pillar tap, capstan head, screw down high 18.00 No 308.73
pressure with screws, shanks and back nuts. (i) 15mm dia.
114 Providing and fixing in position 300 mm high, 150 mm wide 360.00 No 707.00
English letters made from 1.0 mm thick stainless steel sheet as
directed by Engineer in charge with all necessary tools & plants
etc. complete.
115 Providing and fixing Urinal of approved quality including 12.00 No 1550.99
connection with trap and with integral longitudinal flush pipe.(A)
Squating plate pattern white earthenware 550mm x 300mm.
116 Providing and fixing Rubber plug for sink or wash basin. 12.00 No 17.15
117 Providing and fixing chromium plated brass half trun flush cock of 36.00 No 263.77
approved quality including fixing in pipe line etc. complete (ii)
118 Providing and fixing S.W. gully trap with C.I. grating brick 10.00 No 1246.92
masonry chamber and water tight C.I. cover with frame of 300mm
x 300mm size (inside) with standard weight (i) Square mouth
traps (B) 150mm x 100mm size P or R type
119 Constructing brick masonry chamber for underground C.I. 34.00 No 3172.41
Inspection chamber and bends with briocks having croshing
strength not less than 35Kg. Cm2 in C.M. 1:5 precast RCC cover
455mm x 610mm intenal dimensions with frame (R.C.C. top slabe
with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete etc.
complete (i) Inside dimensions 455mmx 610mm and 450mm
deep for single pipe line.
Item Rate In
Description of Item Quantity Unit Amount
No figures
120 Constructing brick masonry chamber for underground C.I. 31.00 No 3883.45
Inspection C.I. Inspection chamber and bends with briocks having
croshing strength not less than 35Kg. Cm2 in C.M. 1:5 precast RCC
cover 500mmx 700mm intenal dimensions with frame (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete etc.
complete (i) Inside dimensions 500mmx 700mm and 450mm
deep for single pipe line.
121 Extra over items for every additional depth of 0.1M. of part 18.00 Each 242.39
thereof beyond 450mm depth for Brick masonry chamber.(i) for
455mm x 610mm size.
122 Extra over items for every additional depth of 0.1M. of part 15.00 Each 264.86
thereof beyond 450mm depth for Brick masonry chamber.(i) for
500mm x 700mm size.
123 Providing cement vata (10cm x 10cm size) quarter round in 195.00 Rmt 23.68
cement mortar 1:1 including neat cement finishing watering etc.
124 Providing and fixing MS Ladder of required pattern with MS 300.00 Kg 113.12
flats(30x3mm) or round or square bars (12mm) at required
spacing & with round headed bolts and nuts or screws or welding
including primer coat of approved quality and two coats of oil
paintas as directed by engineer in charge
125 Providing and fixing in position 150 mm high, English letters 160.00 No 404.00
made from 1.0 mm thick stainless steel sheet as directed by
Engineer in charge with all necessary tools & plants etc. complete.
126 Providing and fixing polished 18 mm thick black granite with full 11.00 Sqmt 2719.93
round edge and double side polished of approved quality in
between urinal and fixing with cement slurry & adhesive
including moulding of both exposed edges as directed by
engineering in charge etc. complete.
127 Constructing Platform of 18 mm thick Polished Black Granite at 8.00 Sqmt 6235.74
top and 25 mm thick Kota stone slab one side polished at bottom
with cementing Materials / adhsives including makeing
necessary grooves in walls with Vertical sandwich two
Kotastone 25 mm support every 60 cm centre to centre or as
required including all labour material of approved quality incl.
full moulded round front edge granite strip of one side polished
and jointed with grey cement slurry including rubbing and
polishing etc. complete for all floors
128 provision and fixing of both side polished machine-cut marble 840.00 Sqmt 1616.00
stone shelves/partitions, ranging from 18mm to 20mm in
thickness, securely embedded into the wall through support fixing
using cement slurry and adhesive. The process encompasses the
necessary adjustments such as cutting the stone to fit as needed,
along with the meticulous smoothing of surfaces to achieve a
refined finish, inclusive of all requisite racking as per directed
engineer in-charge.
129 Providing & fixing in position glass partition with standard 171.00 Sqmt 2469.45
extruded colored anodized aluminum frame size 63mm x 38mm
x 2mm thick make vertical and horizontal grid distance as shown
in drawing with 12mm thick toughen glass directed with glass
film, fixed with transparent silicon rubber gasket in panel with
glazing clips 19 mm x 17.3mmx1.2mm in size including fixtures
and fastening with required all labour and equipment and
including rebar up to slab level in half partition and as per
detailed drawing as directed with all lead and lift.
Item Rate In
Description of Item Quantity Unit Amount
No figures
130 Providing & fixing in position glass panel with standard extruded 255.00 Sqmt 2712.86
colored anodized aluminum frame size 63mm x 38mm x 2mm
thick make vertical and horizontal grid distance as shown in
drawing with 12mm thick toughen glass directed with glass film,
fixed with transparent silicon rubber gasket in panel with
glazing clips 19 mm x 17.3mmx1.2mm in size including fixtures
and fastening with required all labour and equipment and
including rebar up to slab level in half partition and as per
detailed drawing as directed with all lead and lift. for FG
131 providing and fixing 12mm thick compact laminated panel door 11.00 Sqmt 8397.14
of merino or aproved equivalent mae with all accessories handle
and locing system including all fixtures and fastner and laboure
work etc completed as per engineer incharge.
132 Providing and laying and fixing 50 mm thick expansion joint by 166.00 Sqmt 1491.03
hydro cell semi rigid UV resistance with high performance
laminated closed cell polythene foam joint filler in sheet foam as
directed, etc. complete.
133 Applying and providing Expansion joint sealing System on 100 166.00 Sqmt 4772.00
mm vide joint including cleaning of exansion joint by mechanical
means provision of adhesive and flexible membrane with
required bond length as per menufracturer specification and
4mm thick alluminium strip covering with one side sloted and
bolted with suitable system, inclusive of all manpower, machinery
and material as per specification and as directed.
134 Providing and filling the expansion joint by Thioflex 600 polymer 166.00 Sqmt 515.39
or equivalent confirm to BS 4254-1983 as per required shade and
manufactured specifi-cation by making groove of 50 mm x
mm lather by cutting or by repairing groove and removing mortar
drop or any other foreign materials including applying primer
and filling required size (oversize of joint PU foam etc. complete.
135 Providing and fixing 25 cm Wide & 3mm thick exterior composite 111.00 Sqmt 1054.34
panel on existing expansion joint horizontally & vertically with all
material, hardware, acessories & fittings etc completed.
136 Providing & Fixing 114mm wide G.I. Sheets lovers having weight 83.00 Sqmt 7813.36
not less than 490 Gm/m roll formed to create 84mm wide louver
snap fixed on special shaped GI channel. Fix louvers & channels
shall finished with powder coating of 55 micron (1) 0.55mm thick
sheet.etc. complet as per detail drawing as directed.
137 Providing & fixing 25mm thick cupboards of plywood shutter 265.00 Sqmt 3297.65
including fixing 19 mm and 6mm thick back to back flush all proof
plywood & including with Teak Wood frame 40 mm x 25 mm size
as directed etc. complete including necessary both side
lamination 1 mm thick outer side & 0.80mm thick inner side fixing
by necessary SS hinges, handles, magnet, stoppers, etc. as directed
including fevicol, and other hardware material required. Plywood
and all fixture shall be of ISI quality and as approved by engineer-
in-charge including cost of teak wood beading, one coat of primer
and two coats of oil painting or polishing as directed.
138 Providing and fixing 0.45 meter wide Drinking platform 8.00 Sqmt 3038.08
including supplying and fixing granite stone of black or equivalant
quality 18 mm thick mirror polished on top and side posiition
and vertical strip at front with cement slurry & adhesive
including moulding of both exposed edges over 25 mm thick
kotah stone platform fixing in top and sides and itermediates
supports fixing with cement mortar and adhesive and finishing
all material and labour and assessories with necessary fitting
complete etc.
Item Rate In
Description of Item Quantity Unit Amount
No figures
139 Providing and fixing M.S Pipe fabrication For duct made from M.S 61.00 Sqmt 3868.30
pipe of 40 mm dia fitted into M.S Frame with clamp into
RCC/Brick structure at 0.10 m c/c at equal distance fixed
including all required accessories as per detailed drawing as
directed etc. complete. for All Floor
140 Providing and fixing coloured self adhesive PU-Tactile tile, ground 216.00 Sqmt 4791.44
surface indicators of Polyurethane) of size 300mm x 300mm for
guiding/warning to the visually visitors in the centre/side of the
pedestrian/approach pathway as per specification and guidelines
complete in all respect to the entire satisfaction of in charge.
141 Providing and fixing acrylic multilingual Braille (raised dots) 20.00 Nos 1765.48
DIRECTIONAL SIGNBOARDS of size 225 x 150mm designed as
per accessibility standards and having 3.5mm thick acrylic base
plate with Upper Case San Serif words made of white acrylic non
glare cut out letters of height 15mm raised not less than 0.8mm
above base plate and the equivalent word written in Hindi with
Devanagari non glare acrylic letters of height 15mm raised not
less than 0.8mm above base plate and having a non-glare acrylic
cut arrow pointing in the required direction. Each signboard to be
fixed as per manufacturers specifications on the wall at the
approved location and at a height of 1200mm from FFL complete
as per design / specifications and guidelines as per the entire
satisfaction of the Engineer-in-charge
142 Providing & Fixing Braile Indicator Of Size 170 Mm X 35mm For 150.00 Rmt 946.37
Handrails Of The Approved Design And Make Have Braile Dots
Raised 0.5 Mm Above Base Plate To Be Installed At Specific
Locations As Per Direction Of Engineer In Charge
143 Providing and fixing of conspectus tape 50mm width on of treads 30.00 Rmt 304.01
in staircase including cutting pasting etc. As per harmonised
guidelines complete in all respect to the entire satisfaction of
engineer in charge.
144 Providing and Fixing a set of wall mounted 38 mm dia U shaped 6.00 Set 2730.03
horizontal stainless steel collapsible grab bar , 38mm vertical
stainless steel fixed grab rail of grade SS 304 from round pipe
supported and 75 mm dia 8 mm thick SS 304 base flange on wall
including anchor fasteners, nuts, accessories as per detailed
drawing etc. complete as directed by Architect or Engineer in
145 Providing and fixing EURONICS 304 Stainless Steel Handicap Grab 12.00 Nos 3368.35
Bar, Size 600 millimeter, including all necessary fittings and
fixtures, complete as per the direction of the Engineer-in-charge.
146 Excavation for foundation for depth from 3.0 m to 5.0 m including 83.00 Cumt 175.97
sorting out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(B) Dense or Hard soil
147 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size 2.00 Nos 958.17
having weight not less than 35Kg.
148 Providing & erecting open well horizontal mono block pump set 2.00 Nos 36107.50
with cast iron body, complete for three phase submersible motor
having [H]For 15 H.P,3 phase open well horizontal mono block
pump set suitable for 1600 LPM to 1025 LPM @ 33 to 42 MTR
head suitable for 65/80 mm dia delivery pipe
Item Rate In
Description of Item Quantity Unit Amount
No figures
149 Supplying & erecting approvedmake 3 phase motor control 3.00 Nos 19695.00
cubicalpanel (Star-Delta) made from 16G.CRCA sheet duty
painted with epoxy powder painted inside and outside with
hinged doors and locking arrangement, consisting suitable size of
ON-OFF isolator (AC- 3/23duty) main fuses,single phasing
preventer cum water level, Guard(Compe unit), Toggle switch to
by pass Single phase preventercum WLG,indicating lamps forR-Y-
Bphases, over load relay.Automatic water level controller,
incoming wires duty socket Crimped,Panel to be erected on angle
iron frame grouted on wall as overload relay,thermal/Electronics
star delta cutoff timer,start-stop push buttons.The isolator
overload relay &cntractors ofL&T,Siemens or Cuttler Hamer make
only.Panel to be erected on angle iron frame ground on wall
(e)S/D upto
150 Providing 2.5fixing
and H.P. rolling shutters of approved make made of 10.00 Sqmt 3503.41
80 mm wide M.S laths inter-locked together through heir entire
length and jointed together at the ends by end locks mounted on
specially designed pipe shaft with bracket plates,guide channels
and arrangement for inside and outside locking with push-pull
operation including the cost of hood cover and sprig
etc.complete(A) Shutters having width below 3.5M
151 Constructing brick masonry chamber for underground C.I. 20.00 No. 7180.44
Inspection chamber and bends with briocks having croshing
strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions, total weight of
cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.)
and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-
cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat of neat
cement on walls and bed concrete etc. complete.(iii) Inside
dimensions 600mm x 850 mm and 450mm deep for pipe lines
152 with threeand
Providing or more inlets.
laying (two level or slopes) and jointing with stiff 240.00 Rmt. 696.46
mixture of Cement Mortar in proportion 1:1, Salt glazed stone
ware pipes of pipes 150mm laying lime concrete 1:2:4 (1-Lime
putty :2-Fine samd : 4-Graded brick aggregates 40mm nominal
size) bedding for stoneware pipes of following internal diameters
with necessary formwork and curing complete.
153 Box cutting the road surface to proper slope and camber for 1555.00 Cum. 104.04
making a base for road work including removing the excavated
stuff and depositing on the road side slope as directed upto
50Mt.lead.
154 Filling in plinth with sand under floors including watering 519.00 Cum. 532.27
ramming, consolidating and dressing complete
155 Construction of granular sub-base 150 mm thick by providing 389.00 Cum. 1241.29
coarse graded machine crushed B.T. material satisfying MOST
specification of grading I (B.T. stone aggregate 53 mm to 26.5 mm
35 %, 26.5 to 4.75 mm - 45 % and 2.36 mm below - 20 %
)including spreading in uniform layer with motor grader on
prepared surface, mixing by mix in place method with rotavator
at OMC and compacting with vibratory roller to achieve the
desired density etc. complete.
156 Providing and laying wet mix macadam base course 250 mm thick 648.00 Cum. 1262.50
using machine crushed B.T. chips as per required gradation
mixing with required optimum quantity of water, conveying the
mix to site of work, spreading in to grade and camber with
mechanical paver and consolidation each layer with vibratory
roller including cost of material labour plant and equipment etc.
Item Rate In
Description of Item Quantity Unit Amount
No figures
157 Compaction and finishing of cement concrete road by trimix 2468.00 Sqm. 63.63
M.250 process providing extra Labour charges for the trimix
vacume dewatering service process on cement concrete road
sutface by using vacuum dewatering pump floater surface
vibrator including making groves and rough finish to surface
including leveling etc complete.
158 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking 1608.00 Sqm 686.90
concrete block 60mm thick with grade of concrete M300
pnumatic compressed / vibrated mechanically and as per
approved design Confirming to IS 15658 : 2006 including 35 mm
Sand layer for levelling and filling the joint with sand in proper
line and level as per guidlines of IRC : SP 63-2018 etc. Complete.
159 Providing and fixing pre-cast concrete kerb stone of gray cement 832.00 Rmt. 361.64
based concrete block 30cm length,30cm height and 15cm thick of
M250 grade concret as per approved design and including
excavation for fixing in proper line and level,filling the joint with
C:M 1:3 (1cement:3fine sand) etc complete.
160 Drilling of min. 250 mm dia. bore hole in all strata including 310.00 Rmt 1270.58
dualover burden strata by combination DR/DTH rig including
lowering 200 mm dia MS ERW pipes in bore hole and testing
etc.all work as per directed engineer incharge.
161 Manufacture, supply and delivery of cage typeTrapezoidal shape ( 200.00 Rmt 1682.66
' V ') wire wound low carbon, Galvanized screen pipe and
Stainless Steel Screen pipes, confirming IS: 8110 For (B) 200mm
dia 1) 1.00mm Slot size
162 Bore plug having 100 mm height made from M.S. plate with 3 2.00 No 1161.62
holes at equal distance on circumference for nut-bolts type,
locking arrangement with nuts-bolts & lock nuts of std. Make
complete. For 250mm dia
163 Providing PVC insulated flat submersible cable as per detailed 400.00 Rmt 180.79
technical specifications of R/C of GWSSB conforming to IS
IEC 60227 / 60228.d)1 R x 3 C x 6.0 mm2
164 Suppling and installing 3 Phase Borewell 15.00 HP Submersible 2.00 No 37160.93
Pump Sets Electric motor driven conforming to I.S. 8034 and
motor conforms to IS-9283 working at 3 phase 400/440 volt
C/S A.C. supply & 2900 R.P.M. cat
165 Providing and fixing check or non return pully wheel valve of 50 4.00 No 1111.00
mm diameter.
166 Providing and fixing to wall,ceiliing and floor galvanised mild 300.00 Rmt 787.40
steel tubes ( Medium grade ) of the following nominal bore, tube,
fittings and clamps included making good the wall, ceilling and
floor (F) 50 mm
167 Supplying and lowering ISI-mark edunplasticized PVC (uPVC) 80.00 Rmt 393.90
casing pipe,200 mm outer diameter,as per IS:12818
169 Geohydrological ground water investigation including vehicle 2.00 Nos 14428.86
charges for three phase DTH bore/DR tube well including water
sample testing & chemical analysis
170 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 240.00 Rmt 336.24
working pressure poluthene pipes of the following outside Dia.
Low densidy, complete with special falnge compression type
fittings, wall clipsetc. including making good the wall ceiling and
floor.(G)110 mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
171 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 260.00 Rmt 696.90
working pressure poluthene pipes of the following outside Dia.
Low densidy, complete with special falnge compression type
fittings, wall clipsetc. including making good the wall ceiling and
floor.(G)160 mm
172 Providing junction for rain water juncton chamber of size 26.00 Nos. 8981.93
0.60x0.60x0.75m with excavation of size 1.96x1.96 m & 0.15m
thick c.c.1:2:4 bed concrete including brick masonary wall in CM
1:6 of 0.75m height & 0.23m thick with 15mm thick cement
plaster inside & outside & 1.06x1.06 RCC (1:2:4) slab of thickness
0.15m with CRS steel and 0.60mx0.45m cast iron manhole cover
with frame weight not less than 35 kg as per directed by Engineer-
173 Providing Filter chamber of Brick work in C:M 1:6 of size 8.00 Nos. 15287.36
2.06mx1.20m x1.20m & excavation dimension of 2.66mx
1.81x1.35m including C.C 1:2:4 bed concrete of 0.15m thick
including brick work in c.m 1:6 for 23cm thick wall including
15mm thick cement plaster inside & outside with cement slurry &
10cm thick RCC 1:2:4 top cover with frame of minimum weight of
35 kg & filling filter material kapchi in layers (25-40mm & 10-
20mm) & BT metal 40mm & sand as per directed by Engineer-in-
174 Providing Recharging pit of size 2.0m Dia.& 2.0m depth of water 3.00 Nos. 8209.28
logging with excavation filling the pit with gravel & sand in layers
including making 300mm dia bore depth of 4.5mt & above
concrete with kapchi in layers (25-40mm & 10-20mm) & BT
metal 40mm & filling brick as directed by Engineer-in-charge.
175 Providing and laying controlled cement concrete M-250 and 1287.10 Cumt 5943.85
curing complete including the cost of form work but excluding the
cost of reinforcement for reinforced concrete work in Retaning
176 Providing and filter media 600mm thick as directed at the back of 390.03 Sqmt 1248.74
Protection Wall as per detailed specification.
177 Constructing providing and fabricating cattle guard using channel 15.00 Sqmt 5071.21
section frame of size ISMC series 100 mm x 50 mm (Weight
kg/Rmt) and ISMC section 100 mm x 75mm (weight
kg/Rmt) intermediate support for welding G.I.pipe at 12 Cm C/C
of size 50 mm in a frame made of Channel section size 100 mm x
50 mm all round including fixing the unit on prepared chamber of
masonary wall using MS hold fast embeded in masonary wall top
as directed by Engineer in charge and as per drawing and
necessary required arrangement etc complete.
178 Providing and fixing decorative entrance gate made out of cast 1658.00 kg 165.64
iron and various mild steel tabular section combination , the
Ornamental entrance gate should be fixed at compound wall
including pattern and die making , cutting , welding , grinding,
fabrication , fixing in position at compound wall with necessary
pedestal, bearing block and other locking arrangement. The
entrance gate should be painted with two coats of priming coat of
paint, and two coat of oil paint etc complete. As per detail design
and instruction of architect.
Item Rate In
Description of Item Quantity Unit Amount
No figures
179 Providing and fixing concertina coil fencing with punched tape 768.00 Rmt 590.85
concertina coil 600 mm dia 10 mt openable length having 50 no
rounds per 6 mt length, upto 3mt height of wall with existing
angle iron (50mm x50mm x5mm )requird shaped As per Directed
Engeenier in charge. placed 2.4mt or 3.00mt apart and with
horizontal R.B.T. reinforced barbed wire(3 mm) , stud tied with
G.I. staples and G.I. clips to retain horizontal, including necessary
bolts or G.I.barbed wire tied to angle iron, all complete as per
direction of Engineer-in-charge, with reinforced barbed tape
(R.B.T.)/Spring core (2.5 mm thick) and weight 43.478 gm/meter
at compound wall for ESR M4/ intakewell.
180 Steel work, welded in built up sections framed work including 21840.00 kg 90.48
cutting, hoisting, fixing in position and applying a priming coat of
read lead paint & two coat oil paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle cleats
as in main and cross beams. Hip and jack rafters, purlins conneted
to common rafters and the like..
181 Providing and fixing of Ridge flashing for roof panel shall be made 780.00 Sqm 858.67
out of 0.5 mm thick pre coated GI sheet . The Precoated sheet shall
be of minimum 240 mpa steel grade confirming to IS 14246:1995
and shall have zinc coating of minimum 120 gsm as per
IS:277:1992 , 5-7 microns epoxy primer on both side of the sheet
and polyester top coat 15-18 micron. The PPGI Sheet shall have
plastic protective guard film of minimum 25 microns to avoid
scratches during transportation. The ridge shall be fixed to the
steel members by pop rivet or self drilling/self stitching fastners
@ maximum 450 mm c/c along length of capping/flashing etc
complete .
182 Earth work for Embankment including breaking clods,dress 98764.32 Cum 161.22
ing,with all lead and lift.( excluding watering and
consolidation)(E) From borrow pits within 3 km lead.
183 Rolling of Earth work in layers with power roller including filling 98764.32 Cum 22.63
in depressions which occure during the process.
184 Supply. installation, testing & commissioning of ISI approved 1.00 No 98432.21
electrical motor driven jockey pump set having 10.8 m3/hr. @
70m head. The pump unit shall be a horizontally direct mounted
motor. Unit shall comprise the following minimum requirements:
a) Pump, b) Electric motor IE2, c) Foundation bolts, d) Mating
flanges with gasket and fasteners, e) Discharge gauges, etc.
complete in all respect, with labour.
185 Supply, installation, testing & commissioning of Priming tank, 1.00 No 25677.97
HDPE type, 1000 litres, with necessary piping 100 mm size, G.I
pipe for priming the pumps, pipe of with butterfly valves for
isolation, Water Filling to priming tank by piping min. 50 mm size,
with all complete.
186 Supply, installation, testing & commissioning of Manifold( surge 1.00 No 55635.60
vessel,)for fire hydrant system, min. 300 mm diameter, made
from M.S plate, hydro tested to 15 kg./cm2. with ball valves,
header with couplings for fitting pressure switches, pressure
gauges etc.with necessary isolation valves with all complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
187 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW 20.00 Mtr 398.01
piping, conforming to IS:1239, part-I, Heavy class up to 150 mm
dia. and IS:3589, for size 200 mm dia. & above, thickness. G.I. pipe
fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure,
hook-up etc.
Painting for piping, fittings & structural pipe support, shall be
two coat of zinc primer and two coats of fire red conf. to IS:
Shade 536. Complete with all accessories as per approved
drawings, specicification and direction of the Engineer-in-Charge,
with all complete. 25 mm dia.
188 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW 30.00 Mtr 641.95
piping, conforming to IS:1239, part-I, Heavy class up to 150 mm
dia. and IS:3589, for size 200 mm dia. & above, thickness. G.I. pipe
fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure,
hook-up etc.
Painting for piping, fittings & structural pipe support, shall be
two coat of zinc primer and two coats of fire red conf. to IS:
Shade 536. Complete with all accessories as per approved
drawings, specicification and direction of the Engineer-in-Charge,
with all complete. 50 mm dia.
189 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW 36.00 Mtr 1176.90
piping, conforming to IS:1239, part-I, Heavy class up to 150 mm
dia. and IS:3589, for size 200 mm dia. & above, thickness. G.I. pipe
fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure,
hook-up etc.
Painting for piping, fittings & structural pipe support, shall be
two coat of zinc primer and two coats of fire red conf. to IS:
Shade 536. Complete with all accessories as per approved
drawings, specicification and direction of the Engineer-in-Charge,
with all complete. 80 mm dia.
190 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW 260.00 Mtr 1690.47
piping, conforming to IS:1239, part-I, Heavy class up to 150 mm
dia. and IS:3589, for size 200 mm dia. & above, thickness. G.I. pipe
fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure,
hook-up etc.
Painting for piping, fittings & structural pipe support, shall be
two coat of zinc primer and two coats of fire red conf. to IS:
Shade 536. Complete with all accessories as per approved
drawings, specicification and direction of the Engineer-in-Charge,
with all complete. 100 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
191 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW 20.00 Mtr 2525.00
piping, conforming to IS:1239, part-I, Heavy class up to 150 mm
dia. and IS:3589, for size 200 mm dia. & above, thickness. G.I. pipe
fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure,
hook-up etc.
Painting for piping, fittings & structural pipe support, shall be
two coat of zinc primer and two coats of fire red conf. to IS:
Shade 536. Complete with all accessories as per approved
drawings, specicification and direction of the Engineer-in-Charge,
with all complete. 150 mm dia.
192 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW 7.00 Mtr 3423.73
piping, conforming to IS:1239, part-I, Heavy class up to 150 mm
dia. and IS:3589, for size 200 mm dia. & above, thickness. G.I. pipe
fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure,
hook-up etc.
Painting for piping, fittings & structural pipe support, shall be
two coat of zinc primer and two coats of fire red conf. to IS:
Shade 536. Complete with all accessories as per approved
drawings, specicification and direction of the Engineer-in-Charge,
with all complete. 200 mm dia.
193 Supply, installtion, testing & commissioing of Underground GI 20.00 Mtr 2020.00
(ERW) piping conforming to IS:1239, part-I, Heavy class ('C' class)
up to 150 mm dia. and IS:3589 Heavy class ('C' class), for 200 mm
dia. & above, min. 6.35mm thickness including Heavy class
fittings, anti-corrosive tape of size 150 mm wide x 4 mm thick,
wrapping & coating with 13KV holiday testing . Rates shall
include sand bedding of 75mm dia all around, backfilling of the
excavated including installation of heavy pipe fitting's, flanges,
etc. 10 % of all the welded joints shall be done radiographically
tested and 50% of the joints radiographed shall be the "Field
Joints". Hydrostatic testing for 2 hours at 150% of the system
pressure, hook-up etc., complete with all accessories as per
approved drawings, specicification and direction of the Engineer-
in-Charge, with all complete. (Road Crossing) 100 mm dia.
194 Supply, installtion, testing & commissioing of Underground GI 25.00 Mtr 3047.12
(ERW) piping conforming to IS:1239, part-I, Heavy class ('C' class)
up to 150 mm dia. and IS:3589 Heavy class ('C' class), for 200 mm
dia. & above, min. 6.35mm thickness including Heavy class
fittings, anti-corrosive tape of size 150 mm wide x 4 mm thick,
wrapping & coating with 13KV holiday testing . Rates shall
include sand bedding of 75mm dia all around, backfilling of the
excavated including installation of heavy pipe fitting's, flanges,
etc. 10 % of all the welded joints shall be done radiographically
tested and 50% of the joints radiographed shall be the "Field
Joints". Hydrostatic testing for 2 hours at 150% of the system
pressure, hook-up etc., complete with all accessories as per
approved drawings, specicification and direction of the Engineer-
in-Charge, with all complete. (Road Crossing) 150 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
195 Design , Supply and installation of Safety Signage made of Zinc 5600.00 Sq. inch 9.41
Sulphilde based glow in dark , Rigid sheet with High Luminous
property enclosed in a transperent weather proof UV stabilized
plastic pasted on 3 mm thick clear acrylic sheet such as EXITS,
EMERGENCY EXIT, DO NOT USE LIFT DURING FIRE, FLOOR
MARKINGS, FIRE LIFT, STAIRCASE EXIT, FIRE ALARM CALL
POINT, FIRE HOSE REEL, FIRE HYDRANT POINT etc.
196 Supply, installation, testing & commissioning of pressure switch. 3.00 No 2824.58
(Range 0 to 16 kg/cm2)
197 Supply, installation, testing & commissioning of 150 mm dia. dial 6.00 No 2738.99
Burdon Type Glycerine Filled pressure gauge with isolation ball
valve arrangements with necessary isolation valves with all
complete.( Range 0 to 15 kg/cm2)
198 Supply, installation, testing & commissioning of Cast iron body 2.00 No 5905.93
double flanged gate valve With Rising Spinldle conf. to IS:
PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm
thick, etc., with all complete. 50 mm dia.
199 Supply, installation, testing & commissioning of Cast iron body 1.00 No 8182.71
double flanged gate valve With Rising Spinldle conf. to IS:
PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm
thick, etc., with all complete. 80 mm dia.
200 Supply, installation, testing & commissioning of Cast iron body 2.00 No 10271.18
double flanged gate valve With Rising Spinldle conf. to IS:
PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm
thick, etc., with all complete. 100 mm dia.
201 Supply, installation, testing & commissioning of Cast iron body 1.00 No 15920.34
double flanged gate valve With Rising Spinldle conf. to IS:
PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm
thick, etc., with all complete. 150 mm dia.
202 Supply, Installation, Testing & Commissioning of Cast iron body 5.00 No 2011.45
Butterfly valve according to IS: 13095, PN-1.6, Iron Disc for size
150 mm dia. & below Lever operated and above 150 mm dia. Gear
operated complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all
complete. 50 mm dia.
203 Supply, Installation, Testing & Commissioning of Cast iron body 1.00 No 2567.79
Butterfly valve according to IS: 13095, PN-1.6, Iron Disc for size
150 mm dia. & below Lever operated and above 150 mm dia. Gear
operated complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all
complete. 80 mm dia.
204 Supply, Installation, Testing & Commissioning of Cast iron body 4.00 No 3124.15
Butterfly valve according to IS: 13095, PN-1.6, Iron Disc for size
150 mm dia. & below Lever operated and above 150 mm dia. Gear
operated complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all
complete. 100 mm dia.
205 Supply, Installation, Testing & Commissioning of Cast iron body 2.00 No 4493.65
Butterfly valve according to IS: 13095, PN-1.6, Iron Disc for size
150 mm dia. & below Lever operated and above 150 mm dia. Gear
operated complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all
complete. 150 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
206 Supply, installation, testing & commissioning of Cast iron body 1.00 No 1540.67
Dual Plate Wafer Type NRV conf. to IS: 210, PN-1.6 complete with
mating Flanges class # 150 with bolts & nuts, washers, gaskets
mm thick, etc., with all complete Accessories 50 mm dia.
207 Supply, installation, testing & commissioning of Cast iron body 1.00 No 2225.42
Dual Plate Wafer Type NRV conf. to IS: 210, PN-1.6 complete with
mating Flanges class # 150 with bolts & nuts, washers, gaskets
mm thick, etc., with all complete Accessories 80 mm dia.
208 Supply, installation, testing & commissioning of Cast iron body 2.00 No 3166.96
Dual Plate Wafer Type NRV conf. to IS: 210, PN-1.6 complete with
mating Flanges class # 150 with bolts & nuts, washers, gaskets
mm thick, etc., with all complete Accessories 100 mm dia.
209 Supply, installation, testing & commissioning of Cast iron body 1.00 No 5820.34
Dual Plate Wafer Type NRV conf. to IS: 210, PN-1.6 complete with
mating Flanges class # 150 with bolts & nuts, washers, gaskets
mm thick, etc., with all complete Accessories 150 mm dia.
210 Supply, installation, testing & commissioning of SG iron body 1.00 No 1112.71
SinglePlate Wafer Type NRV conf. to ASTMA 536, PN-1.6 complete
with mating Flanges class # 150 with bolts & nuts, washers,
gaskets 3 mm thick, etc., with all complete. Accessories 50 mm dia.
211 Supply, installation, testing & commissioning of SG iron body 1.00 No 1455.09
SinglePlate Wafer Type NRV conf. to ASTMA 536, PN-1.6 complete
with mating Flanges class # 150 with bolts & nuts, washers,
gaskets 3 mm thick, etc., with all complete. Accessories 80 mm dia.
212 Supply, installation, testing & commissioning of SG iron body 1.00 No 1797.46
SinglePlate Wafer Type NRV conf. to ASTMA 536, PN-1.6 complete
with mating Flanges class # 150 with bolts & nuts, washers,
gaskets 3 mm thick, etc., with all complete. Accessories 100 mm
213 Supply, installation, testing & commissioning of Y Type Strainer 1.00 No 5563.55
complete with mating flanges with bolts & nuts, washers, gaskets
3 mm thick, etc., with all complete accessories. 80 mm dia.
214 Supply, installation, testing & commissioning of Y Type Strainer 1.00 No 7275.42
complete with mating flanges with bolts & nuts, washers, gaskets
3 mm thick, etc., with all complete accessories. 100 mm dia.
215 Supply, installation, testing & commissioning of Y Type Strainer 2.00 No 11555.09
complete with mating flanges with bolts & nuts, washers, gaskets
3 mm thick, etc., with all complete accessories. 150 mm dia.
216 Supply, installing, testing and commissioning of Normax make CI 1.00 No 4194.07
heavy duty ball type foot valve with flanges, nut bolts, gaskets etc.
with necessary complete accessories. 80 mm dia.
217 Supply, installing, testing and commissioning of Normax make CI 2.00 No 6162.72
heavy duty ball type foot valve with flanges, nut bolts, gaskets etc.
with necessary complete accessories. 100 mm dia.
218 Supply, installing, testing and commissioning of Normax make CI 1.00 No 12411.02
heavy duty ball type foot valve with flanges, nut bolts, gaskets etc.
with necessary complete accessories. 150 mm dia.
219 Supply, installation, testing & commissioning of Four way fire 1.00 No 8987.29
brigade Inlet connection with 63 mm dia. stainless steel (SS304)
instantaneous male inlets with built in non return valve in each
inlet with 150 mm dia. header pipe, suitable rubber cap and GI
chain including nuts, bolts, washers, gasket 3 mm thick, etc. with
all complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
220 Supply, installation, testing & commissioning of Two way fire 2.00 No 5135.60
brigade Inlet connection with 63 mm dia. stainless steel (SS304)
instantaneous male inlets with built in non return valve in each
inlet with 100 mm dia. header pipe, suitable rubber cap and GI
chain including nuts, bolts, washers, gasket 3 mm thick, etc. with
all complete.
221 Supplying FIRE bucket round bottom of 9 liters capacity made out 8.00 No 1027.12
of 24 gauge G.I Sheet with extra handle at bottom duly painted
white inside and Red out side with FIRE mark. Filled with dry-
sand and kept on existing stand provided or hung on wall hook.
222 Supplying and erecting floor mounting Stand for keeping four nos. 2.00 No 5563.56
of FIRE buckets comprising 1500 mm in length, 900 mm height
frame made out of 30mm x 30 mm x 4 mm angle iron with cross
supports legs, welded with 4 hooks and duly painted with one
coat of primer and two coats of approved enamel P O red paint.
223 Supply & installation of stainless steel body Orifice Plate of 12.00 No 1069.91
suitable inner bore along with matching flange - as per
specification & requirement as per hydraulic calculation.
224 Providing and fixing approved make Perforated C type cable tray. 10.00 Mtr 471.67
Made from pre- galvanized sheet steel. The cable tray should be
bended as per IS 2062/1079 . with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and
as per instruction of engineer in charge..(5) 300 X 50 X 1.5 mm
225 Providing and fixing approved make Perforated C type cable tray. 10.00 Mtr 322.19
Made from pre- galvanized sheet steel. The cable tray should be
bended as per IS 2062/1079 . with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and
as per instruction of engineer in charge..(3) 150 X 50 X 1.5 mm
226 Supply, installation, testing & commissioning of Oblique pattern 12.00 No 5435.17
type stainless steel (SS 304) single headed External Fire Hydrant
Valve with 63 mm dia. female instantaneous outlet conf. to IS:
5290, type - A, including mating flanges, galvanised nuts,
galvanised bolts/studs, washers & gaskets 3 mm thick with all
227 Supply, installation, testing & commissioning of 63 mm dia. 12.00 No 1754.66
stainless steel (SS 304) Universal Branch Pipe conf. to IS:
228 Supply & installation, testing & commissioing of Fire Fighting 12.00 No 6967.29
Hose - conf. to IS : 636, type B (type- 3), The fire hose shall be
m long with 63 mm dia. stainless steel (SS 304) couplings conf. to
IS: 903, at both the ends for connection with the hydrant valve
and the branch pipe.
229 Supply, installation, testing & commissioning of fabricated from 3 12.00 No 2525.00
mm MS sheet, hose box of size-450 mm x 600 mm x 250 mm -
painted with Fire Red as per IS: 5, shade no. 536 front 3 mm thick
transparent glass with lock & key, handle and brass hinges - to
accommodate one number of 15 mtr long hose and one number of
universal branch pipe, including supporting arrangement with
civil work.
230 Supply, Installation, testing & commissioing of Swinging type mild 12.00 No 7403.82
steel hose reel drum with 20 mm dia. x 30 mtr. rubber hose as per
IS: 884. The mounting stand shall be of mild steel and the hose
shall be fitted with a SS shut-off nozzle & SS ball valve of 25 mm
dia. including supporting arrangement with all complete.
accessories
Item Rate In
Description of Item Quantity Unit Amount
No figures
231 Supplying, fixing & testing of of CI ball Valve 25mm dia. (Thread) 23.00 No 706.14
232 Supplying, fixing & testing of New Battery of diesel engine 150 1.00 No 15834.75
233 Supply and installation of Diesel Tank For Diesel Engine With All 1.00 No 16690.67
Accessories 100 Ltrs.
234 Supplying, filling & testing lube oil for diesel engine 20.00 Ltrs 320.98
235 Supply and commissioning of Oil Filter. 1.00 No 706.14
236 Supplying, filling of diesel in diesel engine tank 75.00 Ltrs 89.87
237 Supply and commissioning of Diesel Filter 1.00 No 427.97
238 Supplying, filling & testing coolant to engine cooling for radiator 20.00 Ltrs 239.66
239 Filling Of Gaps Between pipe and Core Cutting Hole With 59.00 No 299.58
Chemical and Cement
240 Steel work, welded in built up sections framed work including 270.00 Kg 90.48
cutting, hoisting, fixing in position and applying a priming coat of
read lead paint & two coat oil paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle cleats
as in main and cross beams. Hip and jack rafters, purlins conneted
to common rafters and the like.
241 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper 15.00 Mtr 136.35
cable 1.1 KV grade to be erected as directed of following size. (E)
3 core 2.5 Sq. mm for pressure switch
242 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 20.00 Mtr 285.83
multistrand Copper conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at road crossing or
floor of following size of cable. (Only Fire Panel to Fire Pump) (B)
3 core 4 Sq. mm
243 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 30.00 Mtr 497.93
multistrand Copper conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at road crossing or
floor of following size of cable. (Only Fire Panel to Fire Pump) (D)
3 core 10 Sq. mm (Only Fire Panel to Fire Pump)
244 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 30.00 Mtr 213.11
multistrand Copper conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at road crossing or
floor of following size of cable for Diesel Engine Battery Charger
(A) 3 core 2.5Sq. mm
245 Supply, Filling and Fixing of approved make ABC type fire 17.00 No 1968.64
extinguisher - 6 Kg. Capacity as per IS:15683 & IS :
246 Supply, Filling and Fixing of approved make CO2 type fire 17.00 No 5520.76
extinguisher. Capacity 4.5 Kg. (conforming to IS-15683).
247 Supply, Filling and Fixing of approved make ABC Moduler type 3.00 No 3423.73
automatic fire extinguisher. Capacity 5 Kg. (conforming to IS-
248 Submitting the application to obtain Fire Plan Approval and After 1.00 No 151500.00
Completion of Work Obtain Final Fire NOC for 3 Year.
249 Supply, Installation and commissioning of Air Release Valve, 25 2.00 No 1412.29
mm Dia. connection.
250 Supply, Installation and commissioning of Fire Alarm Panel 2.00 No 22725.00
Conventional type, 4 zone, with complete accessories.
251 Supply, Installation and commissioning of smoke detectors / heat 15.00 No 1027.12
detectors, with complete accessories.
252 Supply, Installation and commissioning of plug in base for the 15.00 No 256.78
smoke detectors, hooters, with complete accessories.
253 Supply, Installation and commissioning of Audio hooters , with 12.00 No 1069.91
complete accessories.
254 Supply, Installation and commissioning of Manual Call Points, 12.00 No 1010.00
with complete accessories.
Item Rate In
Description of Item Quantity Unit Amount
No figures
255 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 650.00 Mtr 176.75
multistrand Copper conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of
cables (A) 2 core 2.5 Sq. mm for Fire Alarm System
256 Core cutting in wall and in RCC slab with size as below: 50 mm 34.00 No 342.37
257 Core cutting in wall and in RCC slab with size as below: 80 mm 5.00 No 427.97
258 Core cutting in wall and in RCC slab with size as below: 100 mm 4.00 No 513.56
259 Core cutting in wall and in RCC slab with size as below: 150 mm 10.00 No 599.15
260 Core cutting in wall and in RCC slab with size as below: 200 mm 6.00 No 855.93
261 Supply, installation, testing & commissioning of ISI approved 1.00 Set 186850.00
electrical motor operated Kirloskar make fire hydrant main
pump set horizontal end suction back pull out top discharge
centrifugal fire pump set with all the standard acessories, base
frame, coupling, and foundation bolts with following
specifications: Model -DB 80/26, Flow-96 m3/hr, Head-70
meter, Motor Rating -30KW/40HP/3 ph, Suc x Del - 80 x
262 Supplying, Installation, Testing and commissioning of Kirloskar 1.00 Set 419150.00
make diesel engine driven fire hydrant pump set suitable for
automatic operation and consisting of following: horizontal type,
centrifugal end suction back pull out, top discharge pump of cast
iron body & bronze impeller with m.s.fabricated common base
plate, coupling, coupling guard, foundation bolts etc.,as required.
Model -KFE, Flow-97 m3/hr, Head-70 meter, Engine - 45 HP /
ph, Suc x Del - 100 x
263 Fire Hydrant Panel suitable for 10 hp Jockey pump, 40 hp (97 1.00 No 95445.00
m3/hr @ 70 m head) main electrical pump and 45 hp (97 m3/hr
@ 70 m head) Diesel engine operated pump
A) Incomer, MCCB - 1 Nos, R Y B Indication - 1 Set , VAF
Digital Meter - 1 Set, B) Outgoing , F1 40 HP Star Delta Starter -
For Main pump, F2 10 HP DOL Starter - 1 For Jockey, Pump , F3
Auto - On / Off Diesel Pump With Battery Charger, Control Circuit
With Auto - Manual On/Off, On/Off Trip Indication, On/Off Push
Button , C) Fabrication, Dully Powder Coated PO Red
Colour, Fabricated From 14/16 SWG,GI Sheet , IP-42 Protection,-
Fixed Type Floor Mounted, Cable Entry : Bottom
264 Pay Legal Fees to Concern Authority for Obtaining Plan Approval 5800.00 Sq.mt 12.12
and Final NOC
265 Filling available excavated Earth (Excluding Rock) in trench plinth 74.00 Cumt 130.39
side of foundation . in layer not excluding 20 cm in depth
consolidation each deposited layer by ramming and watering etc.
266 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 837.00 Pt. 485.81
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on
PVC / Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed. (f) with medium
class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
Item Rate In
Description of Item Quantity Unit Amount
No figures
267 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm 383.00 Pt. 674.68
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with
earth continuity of following type erected on PVC /
Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall
/ ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed. (f) with medium class Rigid PVC pipe
and accessories erected concealed in wall/ceiling complete.Cat. III
268 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm 2.00 Pt. 510.05
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [I] For 6A Plug and 6 a
switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb
db board (f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
269 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm 3.00 Pt. 745.38
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [II] For 16A Plug and
16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(f)
with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
270 Point wiring for on board Looped Plug with 6A Modular type 145.00 Pt. 257.55
switch & 5 pin socket erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall / ceiling
with following type accessories Cat. III
271 Providing following type of Modular Type Accessories mounted 27.00 Ea. 151.50
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (1)One No. SP 6 Amp. Cat.III
272 Providing following type of Modular Type Accessories mounted 27.00 Ea. 151.50
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (2) One No 5 pin plug Cat.III
273 Providing following type of Modular Type Accessories mounted 248.00 Ea. 25.25
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (7) Blank Plate Single Cat.III
274 Providing following type of Modular Type Accessories mounted 13.00 Ea. 180.79
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (9) 16 Amp. SP one way switch Cat.III
Item Rate In
Description of Item Quantity Unit Amount
No figures
275 Providing following type of Modular Type Accessories mounted 37.00 Ea. 199.98
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (10) 6/16Amp. Universal socket Cat.III
276 Providing following type of Modular Type Accessories mounted 24.00 Ea. 410.06
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A
Double Pole Modular MCB Switch
277 Providing and erecting ISI mark Medium class RIGID PVC PIPES of 1848.00 Mtr. 24.24
following size complete to be erected on/in wall or ceiling
erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & Clamps with following dia of pipes, in
approved manner as directed (a)20 mm
278 Supplying and laying UPVC cable trunking system comprising 48.00 Mtr. 277.75
unplasticised polyvinyl, chloride rigid material with ignition free
and flame proof confirming BS with necessary end caps Internal
and external bend, flat bends, coupler, tee etc..All necessary
accessories and measuring of following sizes (1) 75 mm x 50 mm
279 Providing and erecting Mains with 1.1 KV grade FRLS PVC 3924.00 Mtr. 82.82
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of
following size (A) With medium class Rigid PVC pipe and
accessories (b) 2 wire 2.5 sq. mm
280 Providing and erecting Mains with 1.1 KV grade FRLS PVC 480.00 Mtr. 112.11
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A) with
medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
281 Providing and erecting Mains with 1.1 KV grade FRLS PVC 30.00 Mtr. 147.46
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A) with
medium class Rigid PVC pipe and accessories (b) 2 wire 6 sq. mm
282 Providing and erecting Mains with 1.1 KV grade FRLS PVC 600.00 Mtr. 260.58
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A) with
medium class Rigid PVC pipe and accessories (h) 4 wire 6 sq. mm
283 Providing and erecting Mains with ISI marked, 1.5KV grade 228.00 Mtr. 56.56
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with
required size of copper lugs, nuts and bolts if required. (e) One
wire 6.00 sq. mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
284 Providing and erecting Mains with ISI marked, 1.5KV grade 56.00 Mtr. 300.98
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with
required size of copper lugs, nuts and bolts if required. (i) One
wire 35.00 sq. mm
285 Supplying and erecting Flexible PVC insulated multi strand multi 1848.00 Mtr. 22.22
core 1.1 kv grade ISI marked copper wires of following size to be
erected as directed. (c) 1.00 Sq.mm 2 core round/ flat PVC
286 Supplying and erecting Flexible PVC insulated multi strand multi 294.00 Mtr. 46.46
core 1.1 kv grade ISI marked copper wires of following size to be
erected as directed. (e) 1.50 Sq.mm 3 core round PVC sheathed
287 Providing & erecting Switch board for Computer or electric 142.00 Ea. 1133.22
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
288 Decorative call bell Ting-tong box type 250 volts complete erected 2.00 Ea. 71.71
289 Supplying and erecting LED indoor fittings with LEDs of wattage 700.00 Ea. 535.30
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt
,LED LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
between the ranges shown.) (A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll
290 Supplying and erecting led lamps with following wattage capacity 24.00 Ea. 112.11
of 220 to 240 voltage, minimum 15000 burning hours life, 500 V
in built-surge protection,Polycarbonate diffuser, mounting
suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED
Lamps integral type, with PC diffuser suitable LAMP holder (ii)
5 to 8 watts Cat-III
291 Supplying and erecting LED indoor fittings with LEDs of wattage 68.00 Ea. 1794.77
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt , LED driver
efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of
any wattage capacity between the ranges shown.) (B) LED Panel
Light with provision for Plane front frame with translucent cover
fixed to housing complete.IP20 (vi) 36 watts, 24" x 24", Surge-
2KV Cat-lll
Item Rate In
Description of Item Quantity Unit Amount
No figures
292 Supplying and erecting LED street light / Flood light fittings with 46.00 Ea. 5976.17
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge
Street Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection. (iii)
Above 60 to 90 watts Cat-lll
293 Supplying and erecting LED street light / Flood light fittings with 8.00 Ea. 9647.52
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge
Flood Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection. (vii)
(vi)above 160 to 200 watts Cat-lll
294 Supplying and erecting LED street light / Flood light fittings with 2.00 Ea. 4819.72
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge
Post Top Lantern LED fitting comprises of finish cast aluminum
spigot and spun aluminum canopy fixed with opal polycarbonate,
pipe arrangement for vertical mounting driver and accessories
wired upto terminal block.IP 65 (ii)32-40W Cat-lll
295 Pproviding and erecting Approved make Four pole moulded case 1.00 Ea. 6173.12
circuit breaker having breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply 50 c/s.
with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing.ICS=100% of ICU only Cat III
Item Rate In
Description of Item Quantity Unit Amount
No figures
296 Providing and erecting Approved make Four pole moulded case 5.00 Ea. 8055.76
circuit breaker having breaking capacity ICU of 35 KA. at 415 V.
having normal current rating 125A. with Fixed thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper & complete erected
in existing 16 G.M.S. housing. ICS=100% of ICU only
297 Providing and erecting Approved make Four pole moulded case 3.00 Ea. 16221.61
circuit breaker having breaking capacity ICU of 35 KA. at 415 V.
having Normal current rating 200A.with variable Thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper & complete erected
in existing 16 G.M.S.housing ICS=100% of ICU only Cat III
298 Providing and erecting Approved make Four pole moulded case 2.00 Ea. 20946.39
circuit breaker having breaking capacity ICU of 35 KA. and above
at 415 V . having normal current rating 250A. with variable
thermal & magnetic release suitable to work on A.C.supply 50 c/s.
with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100% of ICU only
299 Supplying & erecting approved make Four Pole 415V change over 1.00 Ea. 13353.21
switch interior for panel mounting with operating mechanism
A.C.23 duty confirming to IS for (E)250A / 320A Cat-lll
300 Supplying and erecting triple pole & neutral 440V / 500V panel 2.00 Rn.Mtr 1961.42
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with
necessary connections. (A) Suitable for 100 Amp. Capacity
301 Supplying and erecting triple pole & neutral 440V / 500V panel 1.00 Rn.Mtr 3202.71
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with
necessary connections. (B) Suitable for 200 Amp. capacity
302 Supplying and erecting triple pole & neutral 440V / 500V panel 1.00 Rn.Mtr 4909.61
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with
necessary connections. (C) Suitable for 300 Amp. capacity
303 Providing and erecting Miniature circuit breaker single pole 6A to 304.00 Ea. 112.11
25A suitable to operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
304 Providing & erecting 240 V MCB double pole switch for lighting 1.00 Ea. 278.76
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity (A) 6 to 32 Amp.
305 Providing & erecting 240 V MCB double pole switch for lighting 4.00 Ea. 295.93
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity (B) 40 Amp. Cat.III
Item Rate In
Description of Item Quantity Unit Amount
No figures
306 Providing & erecting 415V MCB Four Pole Switch for Lighting 50.00 Ea. 638.32
Load (B curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity (b)40 Amp. Cat.III
307 Sheets steel powder coated enclosure suitable for incorporating 3.00 Ea. 176.75
One/Two nos. MCB.
308 Providing and erecting Sheet Steel powder coated MCB 2.00 Ea. 1492.78
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company of MCB to be
used) suitable for (A) single phase incoming and horizontal single
phase outgoing (b) sheet steel double door (IP-43) (iv)12 way
309 Providing and erecting Sheet Steel powder coated MCB 20.00 Ea. 2339.16
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company of MCB to be
used) suitable for (B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type (PPI) (b) sheet
steel double door (i)4 way
310 Providing and erecting Approved make RCCBs conforming to IS: 4.00 Ea. 1969.50
12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on single
phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed (i)
Amps.DP Cat. III
311 Providing and erecting Approved make RCCBs conforming to IS: 61.00 Ea. 2235.13
12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on single
phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed (ii)
40Amps. DP Cat. III
312 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 25.00 Kg. 794.87
313 Providing and erecting HOT deep Galvanised iron strip wire 8 to 66.00 Kg. 77.77
314 Providing and erecting Pipe type earthing having 150 cms.long 17.00 Ea. 368.65
and 2.5 cms. dia. galvanised iron pipe with coupling and buch
buried in specially prepared earth pit complete with necessary
SWG earth wire.
315 For using salt and charcoal / coke as required for pipe type 17.00 Ea. 171.70
Item Rate In
Description of Item Quantity Unit Amount
No figures
316 Supplying & erecting earth pit of minimum bore dia.150mm size 8.00 Ea. 4591.46
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved
make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain moisture for long
time Necessary test report must be submitted by Agency. (a) For
Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
317 Providing & erecting weather proof, dust & vermin proof, floor 6.00 Sq.Mtr 10468.65
mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for
outer body & doors, 16 SWG thick CRC M.S.sheet for internal
partitions with necessary accesories , supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied switch
gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, bakelite
control fuses/MCB for measuring instruments, earth bus & earth
bolts, foundation flange - bolts-base Plates, sufficient nos. of
hinged doors, handles with locking arrangement and rubber
gasket,heavy duty end terminal connection,danger notice
board,necessary ventilation,earthing strip complete. The Panel
shall be painted with epoxy powder coating. (The rates excludes
the cost of switchgears, bus bars, inter connecting mains &
Copper Aluminium strips, meters, Fuses etc. The dimension shall
be measured excluding base beams) The panel shall be supplied
with following approved manufacturers with following size. (A)
locally fabricated panel board (i) with 350mm depth
318 Providing , erecting , fabricating the M.S. structure as per 80.00 Kg. 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections complete with
cutting, welding, grinding & finishing duly painted with one coat
of red oxide with erection on site as per direction of engineer in
charge with necessary grouting, cementing, plastering & finishing
319 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 40.00 Mtr. 92.92
Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of
cables. (B) 2 core 6 Sq. mm
320 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 28.00 Mtr. 490.86
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following
size of cables (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Item Rate In
Description of Item Quantity Unit Amount
No figures
321 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 235.00 Mtr. 540.35
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following
size of cables (F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
322 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable 1168.00 Mtr. 126.25
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe of
following size of cables (B) 4 core 6 Sq. mm
323 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable 40.00 Mtr. 153.52
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following
size of cables (A) 4 core 16 Sq. mm
324 Making trench in soft soil of suitable width of 90 cm deep for 982.00 Mtr. 55.55
laying cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
325 Supplying following size of Light duty “A” Class G.I . Pipe & 20.00 Mtr. 300.98
erecting as directed by Engineer-in-charge. (B) 50 mm dia
326 Supplying following size of Light duty “A” Class G.I . Pipe & 14.00 Mtr. 696.90
erecting as directed by Engineer-in-charge. (D) 100 mm dia.
327 Providing & laying approved make Double walled corrugated 842.00 Mtr. 62.62
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cable (A)50 mm outer dia
328 Providing & laying approved make Double walled corrugated 148.00 Mtr. 137.36
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cable (D)120 mm outer dia.
329 Providing and, fixing heavy duty flange type brass cable gland 17.00 Ea. 38.38
with rubber ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of cables. (B)
2 to 4 core 6 Sq. mm
330 Providing and, fixing heavy duty flange type brass double 4.00 Ea. 131.30
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables. (D) 3 & 1/2 core 95 Sq. mm
331 Providing and, fixing heavy duty flange type brass double 8.00 Ea. 140.39
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables. (E) 3 & 1/2 core 120 Sq. mm
332 Solder less crimping type Aluminium lugs conforming to IS 4.00 Ea. 20.20
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (D)
333 Solder less crimping type Aluminium lugs conforming to IS 2.00 Ea. 25.25
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (E)
334 Solder less crimping type Aluminium lugs conforming to IS 18.00 Ea. 40.40
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (F)
Item Rate In
Description of Item Quantity Unit Amount
No figures
335 Solder less crimping type Aluminium lugs conforming to IS 28.00 Ea. 45.45
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (G)
336 Providing & erecting Approved make Power Saving 50 Watt 383.00 Ea. 1948.29
Ceiling Fan with double ball bearing ISI mark with Condenser
volt A.C. 50 Hz 1200 mm sweep complete having 3blades with
aluminium blades with , canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in charge))
337 Supplying and erecting 19 / 20 mm. nominal bore Medium Class 383.00 Mtr. 108.07
M.S. Pipe down rod erected duly painted for fan complete with
proper insulation without leakage and earthing.
338 Supplying & erecting fan hook box of 10 mm M.S. round bar 383.00 Ea. 108.07
bounded to the RCC bars up to 50mm length each side and
pierced through a 16 Gauge M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling with necessary finishing.
339 Providing 2.5mm.thick laminated acrylic sheet to cover the fan 383.00 Ea. 18.18
hook or Fan box.
340 Supplying & erecting approved make low noise decorative 3.00 Ea. 1366.53
exhaust fan having square frame ABS body with inbuilt lowers &
square frame. 250mm with 1350 RPM Cat.II
341 Supplying & erecting single phase approved make industrial 40.00 Ea. 2054.34
exhaust fan suitable for medium duty ring mounted low noise
operation suitable for medium duty having following dia size and
maximum speed in RPM [A] 305 mm dia 900 RPM Cat.II
342 Supplying and erecting approved make Octagonal pole made from 32.00 Ea. 8192.11
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759,
suitable suspend local wind speed with integral Junction box
consist of terminal plate of min 6mm Hylam sheet, standard
profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be erected
With Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr. Long
mm Top X 135 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm long
J-Bolt.Approx Pole weight 59 kg
343 Supplying & erecting approved make SMC press moulded 10.00 Ea. 515.10
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN rail
for mounting mob & hinged doors as per requirement having
locking arrangements with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable clamps& earth
bolt of following size of box. (B) 250mm x 200mm x 100mm
Supplying and erecting Street light pole bracket comprising main 18.00 Ea 491.87
B Class GI pipe of 4.2 cm/require outside dia. complete with
suitable B Class G.I. sleeve tubing of approx. 45cms.length and
suitable for 76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of 0.5 mtr.
Length with 110 deg.with vertical plane and suitable welded
stiffener reducer and nipple with check nut complete painted
with one coat.of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms. [A] Single
Arm bracket 0.5 Mtr
Item Rate In
Description of Item Quantity Unit Amount
No figures
345 Supplying and erecting Street light pole bracket comprising main 14.00 Ea 622.16
B Class GI pipe of 4.2 cm/require outside dia. complete with
suitable B Class G.I. sleeve tubing of approx. 45cms.length and
suitable for 76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of 0.5 mtr.
Length with 110 deg.with vertical plane and suitable welded
stiffener reducer and nipple with check nut complete painted
with one coat.of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms. [B]
Double Arm
346 Supplying & Bracket
erecting0.5 Mtrgrade following size section pillar
fabricated from joint less M.S. Sheet with angle iron legs made
from jointless M.S. Angle with cable clamps to be buried in ground
to have appropriate erection to work uniform until erected with
cement concrete foundation and 45 cm high bricks work finishing
with plaster etc. hinged double door internally supported on both
side, with internal and outside looking arrangement with look
and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one
is welded and other with nut and bolt for erecting Bakelite sheet.
Painting the Section Pillar inside and out side with three tank
powder coated paint. section pillar roof should be without joint
with water leakage proof & tested as per IP 55 test & followed by
IS 2147 of 1962 (B) 75 X 60 X 45 cm section pillar fabricated from
16 Gauge MS Sheet with angle iron legs 45 cm long made from
X 35 X 5 mm thick MS angle.
347 Supplying and erecting HYLAM sheet on existing angle iron 1.00 sq.mtr 1541.26
frame.for following thickness (D) 8mm
348 Supplying and erecting nuwood 12 mm thick on existing angle 1.00 Sq.Mtr 291.89
iron frame.
349 Providing and erecting Inverter based approved make Cassette 16.00 Ea. 80731.32
type split air-conditioning unit consisting of condensing unit with
fan motor, hermetically sealed scroll/rotary compressor with
accessories etc. duly connected separately erected evaporating
unit and blower motor with its accessories by Eco friendly Green
gas charging & Internal copper wiring & Remote control ( 3 star
and above of current year) with necessary core cutting. (B) for
ton capacity
350 Supplying and erecting insulated pair of soft copper tubing open 154.00 RMT. 965.56
or concealed including power and control cable,necessary PVC
drain pipes for Split AC machine up to 4 TR capacity
351 Supplying and erecting approved make Single phase power 16.00 Ea. 3232.00
conditioners suitable for input voltage 180V / 280V, output
voltage 220V (+ / - 10%) AC 50 ‘Hz with electronic relays &
component of housed in sheet metal cabinet ‘with epoxy powder
switch, 5/15 A universal socket with range off (D) 4 KVA
352 Providing & erecting water cooler having storage capacity 150 3.00 Ea. 55893.40
Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚
C. The outlet temp. of the water should drop by 15˚C within a
hour, The water cooler should be comprising of hermetically
sealed compressor, fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats, relay etc.complete
with necessary inlet & outlet connection. The body of water
cooler will be made from Stainless Steel.
Item Rate In
Description of Item Quantity Unit Amount
No figures
353 Supplying & erecting reverse osmosis (RO) water purification 3.00 Ea. 77891.20
system with M.S. powder coated pedestal frame, prefilter housing
carbon filter suitable buster DC pump, auto low & high pressure
switches with following size of LPH capacity & erected as directed
[D] 100 LPH with 1 phase / 3 phase Raw water pump of 500LPH
@ 2.5kg/cm2 - (1N0 - Kirloskar /CRI/Lubi), Dual media filter
10"x54" - (1 No), Micron cartridge filter 20" x 2.5" ( 1No), High
pressure pump 500LPH @ 10kg/cm2 - (1No - Shimge /CRI /Lubi),
RO Membrane housing with RO membrane of 40*40 - (1No), RO
pressure tube 4" x 1E - ( 1No), 0 - 1200LPH Rotameter -(2 Nos),
with Recovery Rate 50%.
354 Supplying and erecting approved make panel mounting type 4.00 Ea. 1275.63
Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts
range erected on existing panel board with all connection, wiring
etc .with manufacturers calibration certificate.
355 Supplying and erecting approved make panel mounting type 4.00 Ea. 1558.43
Digital Ammeter having 3 digits LED display, external CT
operated, calibrated for 0 to 1000 Amps suitable to operate on
500 Volt AC , erected on existing panel board with all connection,
wiring etc .with manufacturers calibration certificate.
3 phase AC Supply 500 V on existing panel board with necessary
connections.
357 Providing & erecting L.T. Current Transformer with bar primary 12.00 Ea. 274.72
50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box
duly secured with insulating materials connected to the meter
358 Supplying and erecting approved make suitable panel indicator 12.00 Ea. 43.43
LED type lamp, lens cover, complete erected with necessary
connections.
Supplying and erecting, commissioning and testing of Diesel
Generating set confirming to IS: 4722:1968 & BS:5514 having
continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply
comprising of a totally enclosed air/water cooled diesel engine
with multi-cylinders developing suitable BHP not less than
following capacity at 1500 RPM with 10% overload for one hour
in 24 hours with standard accessories like fly wheel, lubricating
oil cooler, "A" class governor, heavy duty fuel wheel and
lubricating oil filter, oil bath air filler, lubricating oil pressure
gauge, end exhaust manifold, standard set of tools with adjustable
spanners, screw drivers, cylinder head to cover, joint cylinder
head to exhaust, element lube oil filter, 12 / 24 volts electric
starting equipment complete with standard heavy duty battery,
dynamo, cut-outs, ammeter, necessary wiring, pressure gauge,
starter etc and heavy duty Residential type exhaust silencer and
vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of
required length, standard wall/floor mounted fuel with level
indicator and piping and drip proof alternator, self excited, self
regulated, screen protected, with excitation system, capable of
delivering the rated system output at 415 volts, 3 phase, 0.8 PF,
50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722-
with voltage regulation +/- 5% of rated voltage from no load to
full load. Both the engine and alternator fitted on a common
fabricated steel base plate with antivibration mounting engine
and alternator both connected to each other by flexible flange
coupling and with floor/wall mounted control panel box
MCCB / MCB of adequate capacity,
Item Rate In
Description of Item Quantity Unit Amount
No figures
359 indicator lamps duly wired with HRC fuses. The alternator & 1.00 Each 1029194.04
control panel shall be connected with provided suitable capacity
armoured cable and complete with Acoustic enclosure (canopy)
made out of 16 SWG CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick conforming to IS:8183 /
PU Foam of 40 Density - at least 40 mm. The resin bonded
rockwool covered from inside the canopy by perforated sheet
with 3/4 mm holes, sound level not more than 75 dB at a distance
of 1 mtr, as per PVCT norms. Erection, commissioning and
satisfactory testing as per requirement with first filling of fuel, oil,
etc. with guarantee / Warrantee of complete system for Two
years. & with obtaining all necessary certificate from Electrical
Inspector. The Capacity and Ratings of DG sets are as below.(M)
Continuous rating of 125 KVA ,BHP not less than 154 BHP
360 Supplying & erecting Amplifier having following specification: 1.00 Ea 11298.87
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery)
with automatic changeover from AC to Battery operation, duly
protected by wrong Battery Polarity connections. [[Approved by
Competent Authority i.e. not Below the rank of Executive
Engineer ]
361 Supplying & erecting Booster Amplifier having power output of 1.00 Ea. 9672.77
25OW (RMS,), suitable to obtain combined power output of two,
with 6 mike inputs & suitable to be used independently as a
250watt amplifier in combination with mike & mixer. The booster
Amplifier shall be without mike &Aux. input channels, The system
shall be suitable to operate on 24OV. A.C. & 24 Volts D.C. Battery.
[[Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
362 Supplying & erecting recess wall mounting speaker with 5W rated 66.00 Ea. 591.86
input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz
frequency response with 6 inch dia. cone type 8 ohms speakers
duly fitted in ABS plastic cabinet of colour match with wall or
ceiling of following size. [[Approved by Competent Authority i.e.
not Below the rank of Executive Engineer ] (b)Square shaped
x 260mm size speaker
363 Supplying microphones stands with sturdy mechanism, treble 2.00 Ea 445.41
free movement & positioning of microphones, free from rust with
superior quality of chrome plating with following size.
[[Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ] (c)Fixed height 91 cms. & extendable up to
62 cms. with round base of dia. 23 cms.
364 Supplying, installing and testing approved make microphone for 2.00 Ea. 1284.72
All purpose, with frequency response of 100 - 11000 Hz, having
sensitivity 2.2mv / Pa & impedance 500 Ohms (LO- Z) supplied
with quick detachable holder, 6 mtr twin core cable & 3 pin XLR
connector. [[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
Item Rate In
Description of Item Quantity Unit Amount
No figures
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting
torque Lift 3 phase 440 V A. C. Permanent Magnet Synchronous
motor of proper rating with high efficiency shall be used.[2] Micro
processor based / PLC, ACVVVF, vector control drive with
encoder feedback closed loop system shall be used for lift car and
hall call demand response, UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal relay and safety
controls. [3] Car with M S platform with bracings of adequate size
and to sustain the impact load cabin + passenger with safety
factor of fire for steel and side panels of Stainless steel of sheet of
grade 304 duty. Car ceiling will be S.S. finishes with aesthetic
appearance with LED ceiling lights. Car flooring shall be of s/s
chaker plate design sugeested of engineer in charge. of engineer
in charge. Car doors shall be of stainless steel grade 304, hairline
finish with centre opening / telescopic automatic doors. Car panel
will also be S.S. 304 finished with emergency stop device,
mechanical door safety device, facility of auto/ attended mode. All
car panel buttons and all floor switches must be with brail
language as per lift act. [4] All landing doors must be fire rated for
2 hour shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of 304 with key holes
and infrared curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car along
with alarm switch shall be provided. Also, Emergency Light & Fan
should start immediately without any Time Delay as soon as
power fails.
[6] Digital scrolling indicator system for up-down arrow along
with floor position indicator shall be provided inside the car and
at all floors.
[7] Full height infra red curtain with multiple cross / crossing
light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly
of passenger capacity with Manual Rescue Operation ( Manual
Cranking Facility).
[9] Audio visual indication in the lift car showing over loading
shall be provided such that doors kept open till excess load is
removed. [10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer
shall be provided.
[12] Voice annunciator with suitable music shall be provided in
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor calibration
as per actual site parameters and submission of calibration
certificate submission, door key holes in the floor doors, fireman
switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room
and monkey ladder for lift pit should be provided by the lift
agency, along with the other steel structure works, foundations
for the machine etc…
[16] In the hoist way fascia plate shall be provided without any
extra cost, where ever required as / if directed by engineer in
Item Rate In
Description of Item Quantity Unit Amount
No figures
[17] Permanent wiring with necessary safety devices like RCCB in
all circuit, Over Voltage Under Voltage protection and THD
eliminator in circuit for lift machine room and lift well with
proper numbers of light points, with fixtures, exhaust fan and plug
points shall be provided by the agency. Only 3 phase Power
Supply shall be made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules shall be arranged
by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift
shaft and machine room related to erection of lift shall be made
by lift agency without any extra cost. (granite/marble fixing
around all landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents
and liaison services for obtaining all necessary permission from
lift inspector and other authorities. [20] acrylic transparent
licence/display A4 size holder in lift car [20A] As per statutory
requirement of Govt. Of Gujarat lift & escalator act 2000, lift
agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection
during/after lift erection and provide report by third party
authorized by concern licensing authority 5.agency has to
provide third party insurance upto completion of free
maintenance period and submit the document for the same.
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly visible when
view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of
hairline finish steel grade of 304 should be provided at
appropriate height on the Rear & Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage controlled Stabilizer
suitable for your controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for lift is in
scope of work which rating is sugested by CEICED Department
(electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM
1. Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial Communication mode
including Regenerative power efficient operation,on site
programming facility, Anti nuisance, Pte-opening, BMS/RMS with
necessary online real time monitoring system having necessary
connectivity for remote monitoring & other suitable supporting
hardware & software devices to fulfil the purpose. 2. Floor
Indication LCD Display with call registration & brail mark with
arrival gong and hall lantern & TFT Screen in the car with MP3
Voice Announcer. 3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for car and all Doors,
All landing doors must have fire rating up to 2 hours and car door
must have multi-level crisscross beam door protection. 4. To & fro
communication system & wiring (i.e. car , control room & guard
room ) and Each elevator are equipped with remote monitoring
system.agency has to provide mobile app and user id and
password for monitoring
365 10 Passengers, Ground plus 2 upper floor with Rated Speed of 1.00 Ea. 1474779.78
1.0 m/sec., (C) With General PLUS ADDITIONAL SPECIAL
FEATURES attached herewith. Prem. Cat.
Item Rate In
Description of Item Quantity Unit Amount
No figures
Supply, Installation, Testing & Commissioning of following size of
Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material : Anodized
Aluminum alloy Frame With Twin Wall Profile, Front Cover : High
Transmission Low-Iron Tempered Glass (AR Coated), High
efficency and positive power tolerance Pmax: 0/+5, Module
Efficiency should be approx. 19.5%-22%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep.
temp. co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to
be used. Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty and 25 year
Linear Power Warranty includes all mechanical and electrical
parameters of the Solar panel. Modules must be complied to the
DCR(Domestic content requirements). The Ration of AC to DC is
5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max
efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating
Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Integrated protection of
Inverter are Anti-islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current
Protection, Output Short Circuit Protection, Output Over Voltage
Protection, PV array string fault Protection. Protection Degree:
IP65, User Interface LCD & APP, Datalogger & Communication:
GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated,
Insulation Resistor Detection Integrated, Residual Current
Monitoring Unit Integrated, Output Over Current Protection
Integrated, Output Short Circuit Protection Integrated, Output
Over Voltage Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi,
Module Mounting Structure: The mounting (Rectangular pipe /
square pipe / circular pipe) with requisite cross bars, nuts and
bolts, etc. shall be Hot deep galvanized with minimum 80micron
coating. The Rectangular / square /circular hollow pipe section
used for the structure should have a minimum thickness of
mm. other than above, the material thickness should be minimum
2.5 mm. A certificate of a structural engineer certifying the
strength and stability of the mounting structure to withstand the
weight and wind speed of 150 km/hour throughout the life span
of 25 years of the system, shall be submitted by the vendors. Hot
Dipped Galvanized steel coils. suitable arrangement for base plate
for foundation , solar panel mounting, the structure should be
suitable for carry the load of solar panel,wiring, sprinkler system
etc. with necessary foundation work/wall mount, j bolt, anchor
fastner etc. the nut bolt used for installtion of stucture should be
(SS 304) quality.The ground clearance of the bottom most edge of
solar panel shall not be less than 300 mm to 1200 mm or as per
site’s technical/feasibility requirement. a. Column –The minimum
section (thickness) should be 60MM*40MM b. Rafter - The
minimum section (thickness) should be 60MM*40MM c. Purlin -
The minimum section (thickness) should be 40MM * 40MM
Balane of System with necessary Swichgears (Suitabel size and
protection of ACDB & DCDB), inter connecting wiring, earthing
system as per the CEIG drawing approval, lightining arrester
Item Rate In
Description of Item Quantity Unit Amount
No figures
366 (Excluding GEDA Application fees, Solar connectivity Charges, 75.00 PER KW 40658.56
Meter connectivity Charges, Meter testing Charges.) (F) Grid Tied
Solar Power System: 101 - 250 kW (3 - phase)
Total Rs.
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and words) of the
estimated rate mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for
1 which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix
4 design the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate
mentioned in all the tender.
Deputy Executive Engineer Executive Engineer
Vapi ( R & B ) Sub Division Valsad ( R & B ) Division
Vapi Valsad
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.0 GRs - SBD with Index (2 side)_Final.pdf
4 Building-Specification Booklet (2 side).pdf
BOQ.pdf
PQ.pdf
SBD.pdf
SPECIFICATION.pdf
ALL IN SERVICE MAINTANANCE.pdf
4.0 SBD Specification.pdf
GENERAL SPECIFICATIONS FOR LIFT WORK.pdf
Lift-contract on stamp.pdf
MOU Electrical Work.pdf
NOMINETED ELECTRICAL SUB –CONTRACTORS.pdf
SPECIAL CONDITIONS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .