Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.5 L+₹5.0 L (933.6%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹5.5 L
EMD Value
₹13,848
Closing Date
19 Feb 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE
O/o AE, KUNNAMANGALAM GP, PINCODE 673571
REPAIR WORKS OF DRINKING WATER
2025_LSGD_737269_1
AE/LIDEW/KGM/2024-25
Open Tender
Civil Works - Others
Item Rate
270 days
KUNNAMANGALAM
8 documents required · 8 mandatory
₹1,225
Yes
₹13,848
Yes
9 Apr 2025
12 Feb 2025
20 Feb 2025
12 Feb 2025
19 Feb 2025
12 Feb 2025
Amount
appendix -1 Palorakunnu WSS
OD414403/2024-2025:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 mm dia
OD414511/2024-2025:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 50 mm dia 10Kgf/cm2(Modified 50.18.9.5.1 Without Trenching and Refilling)
OD415061/2024-2025:Providing and fixing ASTM uPVC SCH 40 pipes includes jointing of pipes with one step ASTM uPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 40 mm dia(Modified 50.18.9.6.1 without trenching and refilling)
appendix -2 Kuttambara WSS
OD415118/2024-2025:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 mm dia
OD415129/2024-2025:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 50 mm dia 10Kgf/cm2(Modified 50.18.9.5.1 Without Trenching and Refilling)
OD415128/2024-2025:Providing and fixing ASTM uPVC SCH 40 pipes includes jointing of pipes with one step ASTM uPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 40 mm dia(Modified 50.18.9.6.1 without trenching and refilling)
appendix -3 Vellaram kunnu DWSS
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
OD410224/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD410229/2024-2025:Filling with Quarry muck filling up low low laying and water logged areas with local materials / quarry muck spreading in layers , levelling the top at site and consolidation by ramming , etc. comp0lete for improving the CBR value of subgrade.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
14.66.1:Finish walls with Acryllic Smooth exterior paint of required shade:Old work ( Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
appendix -4 Mankuni meethal wss
OD417295/2024-2025:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 mm dia
OD417264/2024-2025:Providing and fixing ball valve (uPVC, 12.5kg/cm2) of approved quality, High or low pressure,:40 mm nominal bore(Modified 18.18.3)
OD417265/2024-2025:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2(Modified 50.18.9.3.2 Without Trenching and Refilling)
OD417266/2024-2025:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2(Modified 50.18.9.5.1 Without Trenching and Refilling)
OD417267/2024-2025:Providing and fixing ASTM uPVC SCH 40 pipes includes jointing of pipes with one step ASTM uPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 40 mm dia(Modified 50.18.9.6.1 without trenching and refilling)
OD417268/2024-2025:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 50 mm dia 10Kgf/cm2(Modified 50.18.9.5.1 Without Trenching and Refilling)
15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
appendix -5 Karadukunnu WSS
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD416945/2024-2025:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 mm dia
OD415764/2024-2025:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 50 mm dia 10Kgf/cm2(Modified 50.18.9.5.1 Without Trenching and Refilling)
OD415791/2024-2025:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2(Modified 50.18.9.5.1 Without Trenching and Refilling)
OD417059/2024-2025:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2(Modified 50.18.9.3.2 Without Trenching and Refilling)
15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD417177/2024-2025:Providing and fixing ball valve (uPVC, 12.5kg/cm2) of approved quality, High or low pressure,:40 mm nominal bore(Modified 18.18.3)
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
BIJU M T (BID ID -2116637)
Bidder Name
MOIDEEN KOYA V
BIJU M T
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1182782.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .