Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹20.7 LAdmitted-Finance | -17.99% | ₹20.7 L | L1 | Admitted-Finance |
| 2 | L2₹20.8 LAdmitted-Finance | -17.70% | ₹20.8 L | L2 | Admitted-Finance |
| 3 | L3₹22.1 LAdmitted-Finance | -12.67% | ₹22.1 L | L3 | Admitted-Finance |
| 4 | L4₹23.2 LAdmitted-Finance | -8.17% | ₹23.2 L | L4 | Admitted-Finance |
| 5 | L5₹23.5 LAdmitted-Finance | -7.00% | ₹23.5 L | L5 | Admitted-Finance |
Tender Value
₹25.3 L
EMD Value
₹50,620
Closing Date
26 Feb 2026, 6:00 pmClosed
XEN PHED Sangod
XEN PHED Sangod
Repairing and maintenance of 4.4 MLD WTP and replacement of GI pipe cable and electric feeder panel at UWSS Sangod Distt Kota
2026_PHCJA_540933_1
NIT 55/2025-26 Div Sangod
Open Tender
Civil Works - Water Works
90 days
Sangod
as per TD
5 documents required · 5 mandatory
₹500
EE PHED Div. Sangod
₹50,620
Yes
27 Feb 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
26 Feb 2026
21 Feb 2026
21 Feb 2026 - 21 Feb 2026
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Class PN 1.0
200 mm dia
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Manually Operated CI Sluice valve of Class PN-1.0
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.
Manually operated class PN 1.0
350 mm dia
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
Providing and placing of new graded gravel as (i) Size of Gravel vary from 50 mm at the bottom to 2. to 5 mm at the top as detailed: (a) Passing 80 mm screen but held on 10 mm- 150 mm layer (b) Passing 25 mm screen but held on 10 mm- 50 mm layer (c) Passing 10 mm screen but held on 5 mm- 50 mm layer Passing (d) 5 mm screen but held on 2 mm- 50 mm layer (ii) The filter gravel shall be as spherical as possible, hard, clean and uniform in quality and also shall not contain such impurities as dirt and clay as per IS: 8419 (Part-I) for filter gravel specifications. The work also includes washing the gravel with required concentration of HCL acid and finally with water and placing the same in filter beds as per direction of Engineer- In- Charge and technical specification complete in all respect. The gravel shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) amended up to date. (For RGF)
Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.45 to 0.70 mm. (iii) Uniformity Coefficient not be more than 1.70 nor less than 1.30. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 5.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). Filter media (fine sand and coarse sand) should be processed through disintegrator and dust separator in automatic plant including screening of sand to desired specification and washing and cleaning of sand with water by aqua wash technology at quarry site. (For RGF)
Providing, installation, testing and commissioning of vacuum Feed Gas Chlorinator system with all accessories and making connection with existing pipeline required including supply & installation of ejector unit, Vacuum chlorination unit, trunnion roller support, auxiliary container valve, flexible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM 'Y' type strainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity including safety equipment complete in all respect as per specification and the direction of the Engineer.
2 kg/hr capacity
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:
New work (Two or more coats applied @ 3.84 kg/10 sqm).
Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:
New work (two or more coats) over and including scrapping and priming coat with cement primer.
Applying priming coat :
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Lettering with black Japan paint of approved brand and manufacture.
67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure"A" attached with this BSR .
LED Street Light fixture with Minimum lumen output 2450 lm
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 Foradditional technical parameters of product / work refer Annexure 'A' attached with this BSR
P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.
P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.
size 600 mm X 600 mm
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).
For fixed portion
Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.)
With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835.
Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge
Anodized (AC 15 ) aluminium
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tendernotice_2.pdf
PDF • 7.74 MB
BOQ_964264.xls
BOQ • 0.34 MB
TDnit55.pdf
Tender Documents • 7.72 MB
Download all tender documents and submit your bid