Loading…
Loading…
Tender Value
₹7.2 L
EMD Value
₹7,200
Closing Date
6 Jul 2026, 6:00 pmClosed
Executive Engineer, Electrical (R&B) Division, Valsad
Providing Solar Rooftop System on Collector bunglow at Ta. Navsari, dist. Navsari.
317463
TENDER NOTICE NO. 05 OF 2026-27
Open
Electrical Works
Works
Valsad
8 documents required · 8 mandatory
₹900
Executive Engineer, Electrical (Rand B) Division, Valsad
₹7,200
24 Jun 2026
24 Jun 2026
24 Jun 2026
6 Jul 2026
24 Jun 2026
NAME OF Providing Solar Rooftop System on Collector bunglow at Ta. Navsari,
WORK dist. Navsari
Sr. no Qnty. DESCRIPTION Rate in Rate in Unit Amount
1 2 Providing & erecting 240 V MCB double pole switch for 362.59 Rupees Three Ea.
motor & inductive load (C Curve) having 10 KA breaking Hundred Sixty
capacity & confirms to IS : 8828 in existing box having Two And Paise
following capacity. (B) 40 Amp., Cat.III Fifty Nine Only
2 2 Providing & erecting Sheets steel powder coated enclosure 176.75 Rupees One Ea.
suitable for incorporating One/Two nos. MCB. Hundred Seventy
3 195 Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI 112.11 Rupees One Mtr.
armoured cable Aluminium conductor for 1.1 kV. to be laid Hundred Twelve
on wall with necessary clamps or in existing trench / pipe of And Paise
following size of cables. (B) 2 core 6 Sq. mm. Eleven Only
4 65 Making trench in soft soil of suitable width of 90 cm deep for 55.55 Rupees Fifty Mtr.
laying cable or locating the fault all over the run and back Five And Paise
filling the same and making the surface as normal ground. Fifty Five Only
5 65 Providing & laying approved make Double walled corrugated 62.62 Rupees Sixty Mtr.
pipes (DWC) of polyethylene(conforming to IS 14930 II )with Two And Paise
necessary connecting accessories of same material at required Sixty Two Only
depth in existing trench for laying of cable. below ground /
road surface for enclosing cable. (A) 50 mm outer dia
6 4 Providing and, fixing heavy duty flange type brass cable gland 38.38 Rupees Thirty Ea.
with rubber ring for PVC insulated armoured cable complete Eight And Paise
with out going tails, insulating tape etc for following size of Thirty Eight
cables. (B) 2 to 4 core 6 Sq. mm Only
7 Supply, Installation, Testing & Commissioning of following size of Rupees Nil
Grid Tied Solar Power Plant with Solar Panels (ALMM approved):
Frame Material : Anodized Aluminum alloy Frame With Twin Wall
Profile, Front Cover : High Transmission Low-Iron Tempered Glass
(AR Coated), High efficency and positive power tolerance Pmax:
0/+5, Module Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with Waterproof IP67 &
MC4 Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep. temp.
co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to
be used. Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty. Modules must
be complied to the DCR(Domestic content requirements). The
Ration of AC to DC is 5:6 for the Installation capacity which are
given in AC KW. Solar Inverter: MPPT Range: MPPT Range: 80-
1000 V , Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz,
Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi:
<3%, Operating Tempreture Range: -25~60°C, Integrated protection
of Inverter are Anti-islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection,
8 Integrated, Input Reverse Polarity Protection Integrated, Rupees Nil
Insulation Resistor Detection Integrated, Residual Current
Monitoring Unit Integrated, Output Over Current Protection
Integrated, Output Short Circuit Protection Integrated, Output
Over Voltage Protection Integrated, Protection Degree: IP65,
User Interface LCD & APP,Datalogger & Communication:
GPRS / Wi-Fi, Module Mounting Structure: The mounting
(Rectangular pipe / square pipe / circular pipe) with requisite
cross bars, nuts and bolts, etc. shall be Hot deep galvanized
with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have
a minimum thickness of 2.0 mm. other than above, the material
thickness should be minimum 2.5 mm. A certificate of a
structural engineer certifying the strength and stability of the
mounting structure to withstand the weight and wind speed of
150 km/hour , shall be submitted by the vendors. Hot Dipped
Galvanized steel coils. suitable arrangement for base plate for
foundation , solar panel mounting, the structure should be
suitable for carry the load of solar panel,wiring, sprinkler
system etc. with necessary foundation work/wall mount, j bolt,
anchor fastner etc. the nut bolt used for installtion of stucture
should be (SS 304) quality.The ground clearance of the bottom
most edge of solar panel shall not be less than 300 mm to
mm or as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be
b. Rafter - The minimum section (thickness) should be
c. Purlin - The minimum section (thickness) should be 40MM
* 40MM Balane of System with necessary Swichgears
9 lightining arrester system as per the CEIG drawing approval, Rupees Nil
all liasoning work with various gov. dipartment like state nodal
agency,DISCOM & CEIG is included in agency scope
(Excluding All charges namely GEDA Application fees, Solar
connectivity Charges, Meter connectivity Charges, Meter
testing Charges and system stability/strenthning charges.)
10 15 (B) Grid Tied Solar Power System: 7 - 10 kW (3 - phase) 44,081.45 Rupees Forty Per
Four Thousand KW
Paise Forty Five
11 15 Providing & erecting Automatic solar panel cleaning system 1,926.07 Rupees One Per
for solar power projects which includes necessary plumbing Thousand Nine KW
work (UPVC pipes and accessories) from source of water to Hundred Twenty
project site (up to 30 meters),Suitable size of sub mercible/ Six And Paise
open well motor, necessary wiring for motor and sprinkler
system with safety, timer circuit for automatically on/off the
sprinkler system, necessary size oand number of nozzles/JET
(minimum 1 Nozzle/Jet per module). (B) 5KW-10KW
Cleaning System
Deputy Executive Engineer,
Electrical R & B sub-Division,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule B Collector Bunglow.pdf
ELEGIBILITY CRITERIA.pdf
Supplying Insatalling Solar.pdf
TENDER NOTICE NO. 05 OF 2026-27.pdf
4.0 FINAL _ SBD (Electrical Work) _ 2024 _ 120 pg (1).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .